Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Benedict Rothammer has a total of 50 co-authors. Here are the top co-authors by number of shared publications:

  • Sandro Wartzack

    Engineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058 Erlangen, Germany

    7 shared publications
  • Max Marian

    Institute of Machine Design and Tribology (IMKT), Leibniz University Hannover, An der Universität 1, 30823 Garbsen, Germany

    5 shared publications
  • Marcel Bartz

    Department of Mechanical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Engineering Design, Martensstraße 9, 91058 Erlangen, Germany

    4 shared publications
  • Stephan Tremmel

    Engineering Design and CAD, University of Bayreuth, Universitätsstraße 30, 95447 Bayreuth, Germany

    4 shared publications
  • Ivan Křupka

    Department of Tribology Faculty of Mechanical Engineering Brno University of Technology Brno Czech Republic

    3 shared publications
  • Martin Vrbka

    Department of Tribology Faculty of Mechanical Engineering Brno University of Technology Brno Czech Republic

    3 shared publications

Latest Publications

  • Open Access

    Applications of Machine Learning in Early Stage Rolling Bearing Simulations—A Systematic Literature Review

    by Felix Pfister, Sandro Wartzack, Benedict Rothammer

    Rolling bearing simulations are often too computationally expensive for early design decisions, because many simulations are required in a large design of experiments. Therefore, the aim of this systematic literature review is to provide an overview of how machine learning (ML) is used to integrate engineering knowledge in advance when simulations are the primary data source for supervised learning. In the 11 included studies, ML is mainly applied as regression models trained on simulation data to replace repeated solver calls. The applications can be classified into three domains—contact mechanics, lubrication, and dynamics—mostly linked to their domain specific outputs. In most cases, ML models replace the simulation once the model is trained and validated, followed by optimization, which is often performed on the surrogate using evolutionary algorithms. Surrogates have the potential to enable design-space exploration, sensitivity analysis, and uncertainty propagation, but this capability is not yet fully exploited in current practice. The purpose of this review article is to provide a summary of methodological building blocks and practical guidelines to assist researchers and engineers in selecting appropriate ML workflows for simulation-based analysis of rolling bearings in the areas of tribology, dynamics, service life, load capacity, and system-level investigations.


  • Open Access

    Frictional Behaviour and Surface Topography Evolution of DLC‐Coated Biomedical Alloys

    by David Nečas, Adam Gelnar, Benedict Rothammer, Max Marian, Matúš Ranuša, Sandro Wartzack, Martin Vrbka, Ivan Křupka, Martin Hartl

    Advanced engineering coatings offer a promising solution to enhance the longevity and performance of medical biomaterials in orthopaedic implants. This study hypothesises that diamond‐like carbon (DLC) coatings exhibit distinct frictional performance based on substrate and counterface material. Three different DLC coatings were tested using a pin‐on‐plate test in four material combinations. Virgin and DLC‐coated CoCrMo and Ti6Al4V pins were tested under sliding against UHMWPE and glass plates with simulated body fluid lubrication. Results revealed that coating composition significantly impacts frictional performance, with silicon‐ and oxygen‐doped coatings showing great potential to minimise friction. Surprisingly, reducing contact pressure had either a neutral or somewhat negative effect. Future investigations will focus on long‐term testing and lubrication analyses of these material combinations.


  • Open Access

    Subject-specific tribo-contact conditions in total knee replacements: a simulation framework across scales

    by Benedict Rothammer, Alexander Wolf, Andreas Winkler, Felix Schulte-Hubbert, Marcel Bartz, Sandro Wartzack, Jörg Miehling, Max Marian

    Fundamental knowledge about in vivo kinematics and contact conditions at the articulating interfaces of total knee replacements are essential for predicting and optimizing their behavior and durability. However, the prevailing motions and contact stresses in total knee replacements cannot be precisely determined using conventional in vivo measurement methods. In silico modeling, in turn, allows for a prediction of the loads, velocities, deformations, stress, and lubrication conditions across the scales during gait. Within the scope of this paper, we therefore combine musculoskeletal modeling with tribo-contact modeling. In the first step, we compute contact forces and sliding velocities by means of inverse dynamics approach and force-dependent kinematic solver based upon experimental gait data, revealing contact forces during healthy/physiological gait of young subjects. In a second step, the derived data are employed as input data for an elastohydrodynamic model based upon the finite element method full-system approach taking into account elastic deformation, the synovial fluid’s hydrodynamics as well as mixed lubrication to predict and discuss the subject-specific pressure and lubrication conditions.


  • Open Access

    Wear Mechanism of Superhard Tetrahedral Amorphous Carbon (ta‐C) Coatings for Biomedical Applications

    by Benedict Rothammer, Michael Schwendner, Marcel Bartz, Sandro Wartzack, Thomas Böhm, Sebastian Krauß, Benoit Merle, Stefan Schroeder, Maximilian Uhler, Jan Philippe Kretzer, et al.

    Tetrahedral amorphous carbon (ta‐C) coatings have the potential to protect biomedical implants from wear and increase their service life. This study elucidates the biocompatibility, mechanical properties, adhesion, and wear resistance of ta‐C coatings fabricated by physical vapor deposition on cobalt‐chromium‐molybdenum (CoCr) and titanium (Ti64) alloys as well as ultrahigh molecular weight polyethylene (UHMWPE). Satisfactory cytocompatibility is verified using contact angle and surface tension measurements as well as indirect and direct cell testing. Scratch testing demonstrates excellent adhesion to the substrates and as confirmed by nanoindentation, the coatings represent an up to 13‐fold and 182‐fold increase in hardness on the hard and soft materials. In metal pin‐on‐UHMWPE disk sliding experiments under simulated body fluid lubrication, the wear rates of the disk are reduced by 48% (against CoCr) and 73% (against Ti64) while the pin wear rates are reduced by factors of 20 (CoCr) and 116 (Ti64) compared to uncoated pairings. From optical and laser scanning microscopy, Raman measurements, and particle analyses, it is shown that the underlying substrates remain well protected. Nonetheless, focused ion beam scanning electron microscopy revealed coating process‐related and thermally driven subductions as well as tribologically induced near‐surface fatigue, which can potentially constitute critical wear mechanisms.


  • Open Access

    Design of Amorphous Carbon Coatings Using Gaussian Processes and Advanced Data Visualization

    by Christopher Sauer, Benedict Rothammer, Nicolai Pottin, Marcel Bartz, Benjamin Schleich, Sandro Wartzack

    In recent years, an increasing number of machine learning applications in tribology and coating design have been reported. Motivated by this, this contribution highlights the use of Gaussian processes for the prediction of the resulting coating characteristics to enhance the design of amorphous carbon coatings. In this regard, by using Gaussian process regression (GPR) models, a visualization of the process map of available coating design is created. The training of the GPR models is based on the experimental results of a centrally composed full factorial 23 experimental design for the deposition of a-C:H coatings on medical UHMWPE. In addition, different supervised machine learning (ML) models, such as Polynomial Regression (PR), Support Vector Machines (SVM) and Neural Networks (NN) are trained. All models are then used to predict the resulting indentation hardness of a complete statistical experimental design using the Box–Behnken design. The results are finally compared, with the GPR being of superior performance. The performance of the overall approach, in terms of quality and quantity of predictions as well as in terms of usage in visualization, is demonstrated using an initial dataset of 10 characterized amorphous carbon coatings on UHMWPE.


  • Open Access

    Amorphous Carbon Coatings for Total Knee Replacements—Part I: Deposition, Cytocompatibility, Chemical and Mechanical Properties

    by Benedict Rothammer, Kevin Neusser, Max Marian, Marcel Bartz, Sebastian Krauß, Thomas Böhm, Simon Thiele, Benoit Merle, Rainer Detsch, Sandro Wartzack

    Diamond-like carbon (DLC) coatings have the potential to reduce implant wear and thus to contribute to avoiding premature failure and increase service life of total knee replacements (TKAs). This two-part study addresses the development of such coatings for ultrahigh molecular weight polyethylene (UHMWPE) tibial inlays as well as cobalt–chromium–molybdenum (CoCr) and titanium (Ti64) alloy femoral components. While a detailed characterization of the tribological behavior is the subject of part II, part I focusses on the deposition of pure (a-C:H) and tungsten-doped hydrogen-containing amorphous carbon coatings (a-C:H:W) and the detailed characterization of their chemical, cytological, mechanical and adhesion behavior. The coatings are fabricated by physical vapor deposition (PVD) and display typical DLC morphology and composition, as verified by focused ion beam scanning electron microscopy and Raman spectroscopy. Their roughness is higher than that of the plain substrates. Initial screening with contact angle and surface tension as well as in vitro testing by indirect and direct application indicate favorable cytocompatibility. The DLC coatings feature excellent mechanical properties with a substantial enhancement of indentation hardness and elastic modulus ratios. The adhesion of the coatings as determined in modified scratch tests can be considered as sufficient for the use in TKAs.


  • Open Access

    Amorphous Carbon Coatings for Total Knee Replacements—Part II: Tribological Behavior

    by Benedict Rothammer, Max Marian, Kevin Neusser, Marcel Bartz, Thomas Böhm, Sebastian Krauß, Stefan Schroeder, Maximilian Uhler, Simon Thiele, Benoit Merle, et al.

    Diamond-like carbon coatings may decrease implant wear, therefore, they are helping to reduce aseptic loosening and increase service life of total knee arthroplasties (TKAs). This two-part study addresses the development of such coatings for ultrahigh molecular weight polyethylene (UHMWPE) tibial inlays as well as cobalt-chromium-molybdenum (CoCr) and titanium (Ti64) alloy femoral components. While the deposition of a pure (a-C:H) and tungsten-doped hydrogen-containing amorphous carbon coating (a-C:H:W) as well as the detailed characterization of mechanical and adhesion properties were the subject of Part I, the tribological behavior is studied in Part II. Pin-on-disk tests are performed under artificial synovial fluid lubrication. Numerical elastohydrodynamic lubrication modeling is used to show the representability of contact conditions for TKAs and to assess the influence of coatings on lubrication conditions. The wear behavior is characterized by means of light and laser scanning microscopy, Raman spectroscopy, scanning electron microscopy and particle analyses. Although the coating leads to an increase in friction due to the considerably higher roughness, especially the UHMWPE wear is significantly reduced up to a factor of 49% (CoCr) and 77% (Ti64). Thereby, the coating shows continuous wear and no sudden failure or spallation of larger wear particles. This demonstrated the great potential of amorphous carbon coatings for knee replacements.


  • Towards the understanding of lubrication mechanisms in total knee replacements – Part I: Experimental investigations

    by David Nečas, Martin Vrbka, Max Marian, Benedict Rothammer, Stephan Tremmel, Sandro Wartzack, Adéla Galandáková, Jiří Gallo, Markus A. Wimmer, Ivan Křupka, et al.


  • Towards the understanding of lubrication mechanisms in total knee replacements – Part II: Numerical modeling

    by Max Marian, Christian Orgeldinger, Benedict Rothammer, David Nečas, Martin Vrbka, Ivan Křupka, Martin Hartl, Markus A. Wimmer, Stephan Tremmel, Sandro Wartzack


  • Rheological behavior of an artificial synovial fluid – influence of temperature, shear rate and pressure

    by Benedict Rothammer, Max Marian, Florian Rummel, Stefan Schroeder, Maximilian Uhler, J. Philippe Kretzer, Stephan Tremmel, Sandro Wartzack