Yan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yan Li has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
David Huang
The Center for Ophthalmic Optics and Lasers, Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA
10 shared publicationsElias Pavlatos
Oregon Hlth & Sci Univ, Casey Eye Inst, Dept Ophthalmol, Ctr Ophthalm Opt & Lasers, Portland, OR USA
5 shared publicationsWinston Chamberlain
Oregon Hlth & Sci Univ, Casey Eye Inst, Dept Ophthalmol, Ctr Ophthalm Opt & Lasers, Portland, OR USA
4 shared publications- David Huang
Casey Eye Institute, Department of Ophthalmology, Oregon Health & Science University, Portland, OR, USA
2 shared publications Jack L. Weiss
From the Center for Ophthalmic Optics and Lasers (Li, Chamberlain, Tan, Huang), Casey Eye Institute, and Department of Ophthalmology, Oregon Health and Science University, Portland, Oregon, the Brass Eye Center (Brass), Latham, New York, and the Gordon Weiss Schanzlin Vision Institute (Weiss), San Diego, California, USA
2 shared publicationsOu Tan
From the Center for Ophthalmic Optics and Lasers (Li, Chamberlain, Tan, Huang), Casey Eye Institute, and Department of Ophthalmology, Oregon Health and Science University, Portland, Oregon, the Brass Eye Center (Brass), Latham, New York, and the Gordon Weiss Schanzlin Vision Institute (Weiss), San Diego, California, USA
2 shared publications
Latest Publications
- 3 November 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (12) , 4917-4928
Convolutional neural network-based differentiation of intraocular inflammatory cells with ultrahigh-resolution OCT
The differential diagnosis of uveitis is broad and often challenging. A key indicator of intraocular inflammation is the presence of cells in the aqueous or vitreous humor. We developed a lightweight convolutional neural network (CNN) model capable of classifying intraocular inflammatory cell types using ultrahigh-resolution optical coherence tomography (OCT). The model was trained and optimized using OCT images of known cell types—mononuclear cells and granulocytes—and achieved an accuracy of 88.4 ± 0.6%, with an area under the receiver operating characteristic (ROC) curve of 94.3 ± 0.4%. The inflammatory cell compositions predicted by the model were consistent with clinical diagnoses in uveitis patients. This approach offers a promising tool for the diagnosis and monitoring of intraocular inflammation in uveitis.
- 3 November 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (12) , 4917-4928
Convolutional neural network-based differentiation of intraocular inflammatory cells with ultrahigh-resolution OCT
The differential diagnosis of uveitis is broad and often challenging. A key indicator of intraocular inflammation is the presence of cells in the aqueous or vitreous humor. We developed a lightweight convolutional neural network (CNN) model capable of classifying intraocular inflammatory cell types using ultrahigh-resolution optical coherence tomography (OCT). The model was trained and optimized using OCT images of known cell types—mononuclear cells and granulocytes—and achieved an accuracy of 88.4 ± 0.6%, with an area under the receiver operating characteristic (ROC) curve of 94.3 ± 0.4%. The inflammatory cell compositions predicted by the model were consistent with clinical diagnoses in uveitis patients. This approach offers a promising tool for the diagnosis and monitoring of intraocular inflammation in uveitis.
- Open Access
- 3 March 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 14 (3) , 17
Artificial Intelligence–Driven Detection of LASIK Using Corneal Optical Coherence Tomography Maps
To train and validate a convolutional neural network (CNN) to detect the history of laser-assisted in situ keratomileusis (LASIK) surgeries using corneal optical coherence tomography (OCT) maps. Five corneal OCT maps (pachymetry, epithelial thickness, posterior mean curvature, anterior axial power, and anterior stroma reflectance) were utilized as the input of a lightweight CNN model. OCT scans of healthy volunteers and patients who had undergone myopic or hyperopic LASIK were included. Repeated fivefold cross-validation was used to train and evaluate the proposed CNN. In addition, a separate group of post-LASIK participants, who were not included in the cross-validation, was used for out-of-sample testing to assess the CNN model performance. In the cross-validation, the proposed CNN model achieved an overall balanced accuracy of 90.2% ± 3.6% with 93.5% ± 5.2% sensitivity and 97.8% ± 1.7% area under the receiver operating characteristic curve (AUC) in detecting myopic LASIK and 90.2% ± 5.8% sensitivity and 98.2% ± 1.9% AUC in identifying the hyperopic LASIK. In the out-of-sample test, all eyes were classified correctively. The lightweight CNN model with corneal OCT maps provides a useful tool for detecting LASIK history. Artificial intelligence-assisted OCT may offer better management for patients with LASIK history who need cataract surgeries.
- 3 March 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 14 (3) , 17
Open AccessArtificial Intelligence–Driven Detection of LASIK Using Corneal Optical Coherence Tomography Maps
To train and validate a convolutional neural network (CNN) to detect the history of laser-assisted in situ keratomileusis (LASIK) surgeries using corneal optical coherence tomography (OCT) maps. Five corneal OCT maps (pachymetry, epithelial thickness, posterior mean curvature, anterior axial power, and anterior stroma reflectance) were utilized as the input of a lightweight CNN model. OCT scans of healthy volunteers and patients who had undergone myopic or hyperopic LASIK were included. Repeated fivefold cross-validation was used to train and evaluate the proposed CNN. In addition, a separate group of post-LASIK participants, who were not included in the cross-validation, was used for out-of-sample testing to assess the CNN model performance. In the cross-validation, the proposed CNN model achieved an overall balanced accuracy of 90.2% ± 3.6% with 93.5% ± 5.2% sensitivity and 97.8% ± 1.7% area under the receiver operating characteristic curve (AUC) in detecting myopic LASIK and 90.2% ± 5.8% sensitivity and 98.2% ± 1.9% AUC in identifying the hyperopic LASIK. In the out-of-sample test, all eyes were classified correctively. The lightweight CNN model with corneal OCT maps provides a useful tool for detecting LASIK history. Artificial intelligence-assisted OCT may offer better management for patients with LASIK history who need cataract surgeries.
- 1 August 2022
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 38 (8) , 502-510
Detection of Corneal Ectasia Using OCT Maps of Pachymetry and Posterior Surface Mean Curvature
To quantify the abnormal corneal thinning and posterior surface steepening that is observed in keratoconus with an Ectasia Index. Optical coherence tomography (OCT) was used to image the corneas of normal individuals and patients with varying stages of keratoconus (manifest, subclinical, and forme fruste). Maps of corneal pachymetry and posterior surface mean curvature were generated, and an Ectasia Index was calculated by multiplying Gaussian fits obtained from the two types of maps. Repeated five-fold cross-validation was used to evaluate the ability of the Ectasia Index to differentiate between normal and keratoconic eyes. The classification performance of the Ectasia Index was compared to minimum pachymetry and maximum posterior mean curvature. Thirty-two eyes from 16 normal individuals, 89 eyes from 63 patients with manifest keratoconus, 16 eyes from 15 patients with subclinical keratoconus, and 26 eyes from 26 patients with forme fruste keratoconus were included in the study. During cross-validation, 100% of the eyes with manifest (89 of 89) and subclinical (16 of 16) keratoconus were correctly classified by the Ectasia Index. The average classification accuracy for the forme fruste keratoconus group was 63 ± 21% (16.4 of 26). The specificity for the normal group was 91 ± 10% (29.1 of 32). The Ectasia Index had a higher sensitivity for keratoconus detection and similar specificity in comparison to minimum pachymetry and maximum posterior mean curvature. The Ectasia Index could be a valuable additional metric for clinicians to consider when screening for keratoconus. [J Refract Surg. 2022;38(8):502–510.]
- 1 August 2022
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 38 (8) , 502-510
Detection of Corneal Ectasia Using OCT Maps of Pachymetry and Posterior Surface Mean Curvature
To quantify the abnormal corneal thinning and posterior surface steepening that is observed in keratoconus with an Ectasia Index. Optical coherence tomography (OCT) was used to image the corneas of normal individuals and patients with varying stages of keratoconus (manifest, subclinical, and forme fruste). Maps of corneal pachymetry and posterior surface mean curvature were generated, and an Ectasia Index was calculated by multiplying Gaussian fits obtained from the two types of maps. Repeated five-fold cross-validation was used to evaluate the ability of the Ectasia Index to differentiate between normal and keratoconic eyes. The classification performance of the Ectasia Index was compared to minimum pachymetry and maximum posterior mean curvature. Thirty-two eyes from 16 normal individuals, 89 eyes from 63 patients with manifest keratoconus, 16 eyes from 15 patients with subclinical keratoconus, and 26 eyes from 26 patients with forme fruste keratoconus were included in the study. During cross-validation, 100% of the eyes with manifest (89 of 89) and subclinical (16 of 16) keratoconus were correctly classified by the Ectasia Index. The average classification accuracy for the forme fruste keratoconus group was 63 ± 21% (16.4 of 26). The specificity for the normal group was 91 ± 10% (29.1 of 32). The Ectasia Index had a higher sensitivity for keratoconus detection and similar specificity in comparison to minimum pachymetry and maximum posterior mean curvature. The Ectasia Index could be a valuable additional metric for clinicians to consider when screening for keratoconus. [J Refract Surg. 2022;38(8):502–510.]
- 26 May 2022
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (11) , 1285-1291
Measuring corneal astigmatism using OCT in keratoconus
Purpose: To measure net corneal astigmatism using optical coherence tomography (OCT) (Avanti) in individuals with keratoconus and compare the repeatability and accuracy with those obtained using Scheimpflug imaging (Pentacam HR). Setting: Casey Eye Institute, Portland, Oregon. Design: Prospective cross-sectional observational study. Methods: Net corneal astigmatism was calculated in keratoconic and normal eyes using OCT and Scheimpflug imaging with 4 settings—pupil or vertex centration settings with a 3 or 4 mm circular analytical zone. Corneal elevation maps were obtained from OCT images and fitted with the Zernike polynomials to obtain net corneal astigmatism. Manifest refraction astigmatism was used to evaluate the accuracy of net corneal astigmatism measurements. The coefficient of repeatability from 2 repeated measures was calculated. Results: 46 eyes with manifest or subclinical keratoconus and 52 normal control eyes were analyzed. For OCT measurements in keratoconus, better accuracy was achieved with pupil centration and 3 mm analytical zone; however, better repeatability was achieved with vertex centration and 4 mm analytical zone (coefficient of repeatability = 0.53 diopters, the Fligner-Killeen test with Bonferroni adjustment P < .0017). Agreement with manifest refraction was significantly better with OCT compared with that using Pentacam HR (generalized mixed-effect model with Bonferroni adjustment P < .00625). No statistically significant difference was found between instruments or settings in control eyes. Conclusions: OCT was able to measure net corneal astigmatism with better accuracy and precision in keratoconic eyes than the Pentacam HR. Measurements may be more accurate using pupil centration and a smaller analytical zone in patients with keratoconus.
- 26 May 2022
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (11) , 1285-1291
Measuring corneal astigmatism using OCT in keratoconus
Purpose: To measure net corneal astigmatism using optical coherence tomography (OCT) (Avanti) in individuals with keratoconus and compare the repeatability and accuracy with those obtained using Scheimpflug imaging (Pentacam HR). Setting: Casey Eye Institute, Portland, Oregon. Design: Prospective cross-sectional observational study. Methods: Net corneal astigmatism was calculated in keratoconic and normal eyes using OCT and Scheimpflug imaging with 4 settings—pupil or vertex centration settings with a 3 or 4 mm circular analytical zone. Corneal elevation maps were obtained from OCT images and fitted with the Zernike polynomials to obtain net corneal astigmatism. Manifest refraction astigmatism was used to evaluate the accuracy of net corneal astigmatism measurements. The coefficient of repeatability from 2 repeated measures was calculated. Results: 46 eyes with manifest or subclinical keratoconus and 52 normal control eyes were analyzed. For OCT measurements in keratoconus, better accuracy was achieved with pupil centration and 3 mm analytical zone; however, better repeatability was achieved with vertex centration and 4 mm analytical zone (coefficient of repeatability = 0.53 diopters, the Fligner-Killeen test with Bonferroni adjustment P < .0017). Agreement with manifest refraction was significantly better with OCT compared with that using Pentacam HR (generalized mixed-effect model with Bonferroni adjustment P < .00625). No statistically significant difference was found between instruments or settings in control eyes. Conclusions: OCT was able to measure net corneal astigmatism with better accuracy and precision in keratoconic eyes than the Pentacam HR. Measurements may be more accurate using pupil centration and a smaller analytical zone in patients with keratoconus.
- 1 June 2021
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 47 (6) , 759-766
Keratoconus detection using OCT corneal and epithelial thickness map parameters and patterns
Purpose: To detect keratoconus using optical coherence tomography (OCT) corneal map parameters and patterns. Setting: Casey Eye Institute, Oregon Health and Science University, Portland, Oregon. Design: Cross-sectional observational study. Methods: A spectral-domain OCT was used to acquire corneal and epithelial thickness maps in normal, manifest keratoconic, subclinical keratoconic, and forme fruste keratoconic (FFK) eyes. A 2-step decision tree was designed. An eye will be classified as keratoconus if both decision tree conditions are met. First, at least 1 of the 4 quantitative corneal thickness (minimum, minimum–maximum, and superonasal–inferotemporal) and epithelial thickness (standard deviation) map parameters exceed cutoff values. Second, presence of both concentric thinning pattern on the epithelial thickness map and coincident thinning patterns on corneal and epithelial thickness maps by visual inspection. Results: The study comprised 54 eyes from 29 normal participants, 91 manifest keratoconic eyes from 65 patients, 12 subclinical keratoconic eyes from 11 patients, and 19 FFK eyes from 19 patients. The decision tree correctly classified all normal eyes (100% specificity) and had good sensitivities for detecting manifest keratoconus (97.8%), subclinical keratoconus (100.0%), and FFK (73.7%). Conclusions: The 2-step decision tree provided a useful tool to detect keratoconus, including cases at early disease stages (subclinical keratoconus and FFK). OCT corneal and epithelial thickness map parameters and patterns can be used in conjunction with topography to improve keratoconus screening.
- 1 June 2021
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 47 (6) , 759-766
Keratoconus detection using OCT corneal and epithelial thickness map parameters and patterns
Purpose: To detect keratoconus using optical coherence tomography (OCT) corneal map parameters and patterns. Setting: Casey Eye Institute, Oregon Health and Science University, Portland, Oregon. Design: Cross-sectional observational study. Methods: A spectral-domain OCT was used to acquire corneal and epithelial thickness maps in normal, manifest keratoconic, subclinical keratoconic, and forme fruste keratoconic (FFK) eyes. A 2-step decision tree was designed. An eye will be classified as keratoconus if both decision tree conditions are met. First, at least 1 of the 4 quantitative corneal thickness (minimum, minimum–maximum, and superonasal–inferotemporal) and epithelial thickness (standard deviation) map parameters exceed cutoff values. Second, presence of both concentric thinning pattern on the epithelial thickness map and coincident thinning patterns on corneal and epithelial thickness maps by visual inspection. Results: The study comprised 54 eyes from 29 normal participants, 91 manifest keratoconic eyes from 65 patients, 12 subclinical keratoconic eyes from 11 patients, and 19 FFK eyes from 19 patients. The decision tree correctly classified all normal eyes (100% specificity) and had good sensitivities for detecting manifest keratoconus (97.8%), subclinical keratoconus (100.0%), and FFK (73.7%). Conclusions: The 2-step decision tree provided a useful tool to detect keratoconus, including cases at early disease stages (subclinical keratoconus and FFK). OCT corneal and epithelial thickness map parameters and patterns can be used in conjunction with topography to improve keratoconus screening.
- 1 December 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (12) , 7343-7356
Eye motion correction algorithm for OCT-based corneal topography
With its sequential image acquisition, OCT-based corneal topography is often susceptible to measurement errors due to eye motion. We have developed a novel algorithm to detect eye motion and minimize its impact on OCT topography maps. We applied the eye motion correction algorithm to corneal topographic scans acquired using a 70 kHz spectral-domain OCT device. OCT corneal topographic measurements were compared to those from a rotating Scheimpflug camera topographer. The motion correction algorithm provided a 2-4 fold improvement in the repeatability of OCT topography and its agreement with the standard Scheimpflug topographer. The repeatability of OCT Zernike-based corneal mean power, cardinal astigmatism, and oblique astigmatism after motion detection was 0.14 D, 0.28 D, and 0.24 D, respectively. The average differences between the two devices were 0.19 D for simulated keratometry-based corneal mean power, 0.23 D for cardinal astigmatism, and 0.25 D for oblique astigmatism. Our eye motion detection method can be applied to any OCT device, and it therefore represents a powerful tool for improving OCT topography.
- 1 December 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (12) , 7343-7356
Eye motion correction algorithm for OCT-based corneal topography
With its sequential image acquisition, OCT-based corneal topography is often susceptible to measurement errors due to eye motion. We have developed a novel algorithm to detect eye motion and minimize its impact on OCT topography maps. We applied the eye motion correction algorithm to corneal topographic scans acquired using a 70 kHz spectral-domain OCT device. OCT corneal topographic measurements were compared to those from a rotating Scheimpflug camera topographer. The motion correction algorithm provided a 2-4 fold improvement in the repeatability of OCT topography and its agreement with the standard Scheimpflug topographer. The repeatability of OCT Zernike-based corneal mean power, cardinal astigmatism, and oblique astigmatism after motion detection was 0.14 D, 0.28 D, and 0.24 D, respectively. The average differences between the two devices were 0.19 D for simulated keratometry-based corneal mean power, 0.23 D for cardinal astigmatism, and 0.25 D for oblique astigmatism. Our eye motion detection method can be applied to any OCT device, and it therefore represents a powerful tool for improving OCT topography.
- 1 November 2020
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 36 (11) , 757-765
A Coincident Thinning Index for Keratoconus Identification Using OCT Pachymetry and Epithelial Thickness Maps
PURPOSE: To develop a coincident thinning (CTN) index to differentiate between keratoconic and healthy corneas using optical coherence tomography (OCT) measurements of pachymetry and epithelial thickness. METHODS: Pattern deviation maps of pachymetry and epithelial thickness were generated using Fourier-domain OCT images of the cornea. The co-localized thinning of the two maps was quantified using a novel CTN index, which was calculated from Gaussian fits of the regions of maximum relative thinning. The CTN index was validated using k-fold cross-validation, and its classification performance was compared to minimum pachymetry and maximum keratometry. RESULTS: A total of 82 normal eyes and 133 eyes within three groups of keratoconus severity were evaluated. The pattern deviation maps for the keratoconic eyes showed relative thinning that was larger in magnitude and more strongly correlated with the Gaussian function compared to normal eyes (all P < .01). The distance between the pachymetric and epithelial maximum relative thinning locations was significantly smaller for the keratoconic eyes than for the normal eyes (all P < .02). The CTN index was significantly larger for all three keratoconus groups compared to normal eyes (all P < .0001). The CTN index demonstrated a sensitivity of 100% in detecting manifest keratoconus, 100% for subclinical keratoconus, and 56% for forme fruste keratoconus. The overall classification accuracy was better for the CTN index (93%) than for minimum pachymetry (86%) and maximum keratometry (86%). CONCLUSIONS: The CTN index is a highly sensitive measure of coincident pachymetric and epithelial thinning. It provides valuable information for detecting and monitoring early to moderate keratoconus. [ J Refract Surg . 2020;36(11):757–765.]
- 1 November 2020
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 36 (11) , 757-765
A Coincident Thinning Index for Keratoconus Identification Using OCT Pachymetry and Epithelial Thickness Maps
PURPOSE: To develop a coincident thinning (CTN) index to differentiate between keratoconic and healthy corneas using optical coherence tomography (OCT) measurements of pachymetry and epithelial thickness. METHODS: Pattern deviation maps of pachymetry and epithelial thickness were generated using Fourier-domain OCT images of the cornea. The co-localized thinning of the two maps was quantified using a novel CTN index, which was calculated from Gaussian fits of the regions of maximum relative thinning. The CTN index was validated using k-fold cross-validation, and its classification performance was compared to minimum pachymetry and maximum keratometry. RESULTS: A total of 82 normal eyes and 133 eyes within three groups of keratoconus severity were evaluated. The pattern deviation maps for the keratoconic eyes showed relative thinning that was larger in magnitude and more strongly correlated with the Gaussian function compared to normal eyes (all P < .01). The distance between the pachymetric and epithelial maximum relative thinning locations was significantly smaller for the keratoconic eyes than for the normal eyes (all P < .02). The CTN index was significantly larger for all three keratoconus groups compared to normal eyes (all P < .0001). The CTN index demonstrated a sensitivity of 100% in detecting manifest keratoconus, 100% for subclinical keratoconus, and 56% for forme fruste keratoconus. The overall classification accuracy was better for the CTN index (93%) than for minimum pachymetry (86%) and maximum keratometry (86%). CONCLUSIONS: The CTN index is a highly sensitive measure of coincident pachymetric and epithelial thinning. It provides valuable information for detecting and monitoring early to moderate keratoconus. [ J Refract Surg . 2020;36(11):757–765.]
- 25 December 2019
- Published by Wolters Kluwer Health in Cornea
- Vol. 39 (5) , 598-604
Application of Corneal Optical Coherence Tomography Angiography for Assessment of Vessel Depth in Corneal Neovascularization
Purpose: To map and measure the depths of corneal neovascularization (NV) using 3-dimensional optical coherence tomography angiography (OCTA) at 2 different wavelengths. Methods: Corneal NV of varying severity, distribution, and underlying etiology was examined. Average NV depth and vessel density were measured using 840-nm spectral-domain OCTA and 1050-nm swept-source OCTA. The OCTA results were compared with clinical slit-lamp estimation of NV depth. Results: Twelve eyes with corneal NV from 12 patients were imaged with OCTA. Clinically “superficial,” “midstromal,” and “deep” cases had an average vessel depth of 23%, 39%, and 66% on 1050-nm OCTA, respectively. Average vessel depth on OCTA followed a statistically significant ordinal trend according to the clinical classification of vessel depth (Jonckheere–Terpstra test, P < 0.001). In 8 cases where both 840-nm OCTA and 1050-nm OCTA were acquired, there was excellent agreement in the mean vessel depth between the 2 systems (concordance correlation coefficient = 0.94, P < 0.001). The average vessel density measured by 840-nm OCTA was higher (average 1.6-fold) than that measured by 1050-nm OCTA. Conclusions: Corneal OCTA was able to map corneal NV in 3 dimensions and measure vessel depth and density. The depth of corneal NV varied between different pathologies in a manner consistent with previous pathologic studies. The measured vessel density appeared to be affected by the interscan time, which affects blood flow velocity sensitivity, and the wavelength, which affects the ability to penetrate through opacity. These findings suggest possible clinical applications of OCTA for the diagnosis of corneal pathology and quantitative monitoring of therapeutic response in patients with corneal NV.
- 25 December 2019
- Published by Wolters Kluwer Health in Cornea
- Vol. 39 (5) , 598-604
Application of Corneal Optical Coherence Tomography Angiography for Assessment of Vessel Depth in Corneal Neovascularization
Purpose: To map and measure the depths of corneal neovascularization (NV) using 3-dimensional optical coherence tomography angiography (OCTA) at 2 different wavelengths. Methods: Corneal NV of varying severity, distribution, and underlying etiology was examined. Average NV depth and vessel density were measured using 840-nm spectral-domain OCTA and 1050-nm swept-source OCTA. The OCTA results were compared with clinical slit-lamp estimation of NV depth. Results: Twelve eyes with corneal NV from 12 patients were imaged with OCTA. Clinically “superficial,” “midstromal,” and “deep” cases had an average vessel depth of 23%, 39%, and 66% on 1050-nm OCTA, respectively. Average vessel depth on OCTA followed a statistically significant ordinal trend according to the clinical classification of vessel depth (Jonckheere–Terpstra test, P < 0.001). In 8 cases where both 840-nm OCTA and 1050-nm OCTA were acquired, there was excellent agreement in the mean vessel depth between the 2 systems (concordance correlation coefficient = 0.94, P < 0.001). The average vessel density measured by 840-nm OCTA was higher (average 1.6-fold) than that measured by 1050-nm OCTA. Conclusions: Corneal OCTA was able to map corneal NV in 3 dimensions and measure vessel depth and density. The depth of corneal NV varied between different pathologies in a manner consistent with previous pathologic studies. The measured vessel density appeared to be affected by the interscan time, which affects blood flow velocity sensitivity, and the wavelength, which affects the ability to penetrate through opacity. These findings suggest possible clinical applications of OCTA for the diagnosis of corneal pathology and quantitative monitoring of therapeutic response in patients with corneal NV.
- 1 February 2016
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 42 (2) , 284-295
Subclinical keratoconus detection by pattern analysis of corneal and epithelial thickness maps with optical coherence tomography
To screen for subclinical keratoconus by analyzing corneal, epithelial, and stromal thickness map patterns with Fourier-domain optical coherence tomography (OCT). Four centers in the United States. Cross-sectional observational study. Eyes of normal subjects, subclinical keratoconus eyes, and the topographically normal eye of a unilateral keratoconus patient were studied. Corneas were scanned using a 26,000 Hz Fourier-domain OCT system (RTVue). Normal subjects were divided into training and evaluation groups. Corneal, epithelial, and stromal thickness maps and derived diagnostic indices, including pattern standard deviation (PSD) variables and pachymetric map-based keratoconus risk scores, were calculated from the OCT data. Area under the receiver operating characteristic curve (AUC) analysis was used to evaluate the diagnostic accuracy of the indices. The study comprised 150 eyes of 83 normal subjects, 50 subclinical keratoconus eyes of 32 patients, and 1 topographically normal eye of a unilateral keratoconus patient. Subclinical keratoconus was characterized by inferotemporal thinning of the cornea, epithelium, and stroma. The PSD values for corneal (P < .001), epithelial (P < .001), and stromal (P = .049) thickness maps were all significantly higher in subclinical keratoconic eyes than in the normal group. The diagnostic accuracy was significantly higher for PSD variables (pachymetric PSD, AUC = 0.941; epithelial PSD, AUC = 0.985; stromal PSD, AUC = 0.924) than for the pachymetric map-based keratoconus risk score (AUC = 0.735). High-resolution Fourier-domain OCT could map corneal, epithelial, and stromal thicknesses. Corneal and sublayer thickness changes in subclinical keratoconus could be detected with high accuracy using PSD variables. These new diagnostic variables might be useful in the detection of early keratoconus. Oregon Health and Science University (OHSU) and Drs. Li, Tan, and Huang have a significant financial interest in Optovue, Inc. These potential conflicts have been reviewed and managed by OHSU. Dr. Brass receives research grants from Optovue, Inc. Drs. Chamberlain and Weiss have no financial or proprietary interest in any material or method mentioned.
- 1 February 2016
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 42 (2) , 284-295
Subclinical keratoconus detection by pattern analysis of corneal and epithelial thickness maps with optical coherence tomography
To screen for subclinical keratoconus by analyzing corneal, epithelial, and stromal thickness map patterns with Fourier-domain optical coherence tomography (OCT). Four centers in the United States. Cross-sectional observational study. Eyes of normal subjects, subclinical keratoconus eyes, and the topographically normal eye of a unilateral keratoconus patient were studied. Corneas were scanned using a 26,000 Hz Fourier-domain OCT system (RTVue). Normal subjects were divided into training and evaluation groups. Corneal, epithelial, and stromal thickness maps and derived diagnostic indices, including pattern standard deviation (PSD) variables and pachymetric map-based keratoconus risk scores, were calculated from the OCT data. Area under the receiver operating characteristic curve (AUC) analysis was used to evaluate the diagnostic accuracy of the indices. The study comprised 150 eyes of 83 normal subjects, 50 subclinical keratoconus eyes of 32 patients, and 1 topographically normal eye of a unilateral keratoconus patient. Subclinical keratoconus was characterized by inferotemporal thinning of the cornea, epithelium, and stroma. The PSD values for corneal (P < .001), epithelial (P < .001), and stromal (P = .049) thickness maps were all significantly higher in subclinical keratoconic eyes than in the normal group. The diagnostic accuracy was significantly higher for PSD variables (pachymetric PSD, AUC = 0.941; epithelial PSD, AUC = 0.985; stromal PSD, AUC = 0.924) than for the pachymetric map-based keratoconus risk score (AUC = 0.735). High-resolution Fourier-domain OCT could map corneal, epithelial, and stromal thicknesses. Corneal and sublayer thickness changes in subclinical keratoconus could be detected with high accuracy using PSD variables. These new diagnostic variables might be useful in the detection of early keratoconus. Oregon Health and Science University (OHSU) and Drs. Li, Tan, and Huang have a significant financial interest in Optovue, Inc. These potential conflicts have been reviewed and managed by OHSU. Dr. Brass receives research grants from Optovue, Inc. Drs. Chamberlain and Weiss have no financial or proprietary interest in any material or method mentioned.
- Open Access
- 3 February 2015
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 56 (3) , 1430-1436
Aqueous Cell Differentiation in Anterior Uveitis Using Fourier-Domain Optical Coherence Tomography
Purpose: The differential diagnosis of a patient presenting with anterior uveitis is broad and can present a diagnostic challenge. In this study, we evaluate the characteristic findings of inflammatory cells on optical coherence tomography (OCT) both in vitro and in vivo. Methods: Blood from two healthy volunteers was prepared using standardized methods for cell sorting with a flow cytometer (FASCAria; BD Biosciences). Neutrophils, lymphocytes, monocytes, and red blood cells were placed in suspension and scanned with a 26 kHz Fourier-domain OCT system (RTVue; Optovue, Inc.) with 5 µm axial resolution. Custom software algorithms were used to identify cells based on their reflectance distribution. These algorithms were then applied to OCT images obtained from uveitis patients with active anterior chamber inflammation. Results: On OCT images the cells appeared as hyper-reflective spots. In vitro, cell reflectance was statistically significantly different between all of the cell types (neutrophils, monocytes, lymphocytes and red blood cells P < 0.001 Mann-Whitney test). The relationship between underlying disease and cell type imaged on OCT was highly statistically significant with HLA-B27 associated uveitis patients having a predominantly polymorphonuclear pattern on OCT and sarcoidosis and inflammatory bowel disease patients having a predominantly mononuclear pattern on OCT (P < 0.001, Fisher's exact test). Conclusions: These in vitro and in vivo data demonstrate the potential of OCT to evaluate cells in the anterior chamber of patients non-invasively. OCT may be a useful adjunct to guide the diagnosis and treatment of ocular inflammatory conditions.
- 3 February 2015
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 56 (3) , 1430-1436
Open AccessAqueous Cell Differentiation in Anterior Uveitis Using Fourier-Domain Optical Coherence Tomography
Purpose: The differential diagnosis of a patient presenting with anterior uveitis is broad and can present a diagnostic challenge. In this study, we evaluate the characteristic findings of inflammatory cells on optical coherence tomography (OCT) both in vitro and in vivo. Methods: Blood from two healthy volunteers was prepared using standardized methods for cell sorting with a flow cytometer (FASCAria; BD Biosciences). Neutrophils, lymphocytes, monocytes, and red blood cells were placed in suspension and scanned with a 26 kHz Fourier-domain OCT system (RTVue; Optovue, Inc.) with 5 µm axial resolution. Custom software algorithms were used to identify cells based on their reflectance distribution. These algorithms were then applied to OCT images obtained from uveitis patients with active anterior chamber inflammation. Results: On OCT images the cells appeared as hyper-reflective spots. In vitro, cell reflectance was statistically significantly different between all of the cell types (neutrophils, monocytes, lymphocytes and red blood cells P < 0.001 Mann-Whitney test). The relationship between underlying disease and cell type imaged on OCT was highly statistically significant with HLA-B27 associated uveitis patients having a predominantly polymorphonuclear pattern on OCT and sarcoidosis and inflammatory bowel disease patients having a predominantly mononuclear pattern on OCT (P < 0.001, Fisher's exact test). Conclusions: These in vitro and in vivo data demonstrate the potential of OCT to evaluate cells in the anterior chamber of patients non-invasively. OCT may be a useful adjunct to guide the diagnosis and treatment of ocular inflammatory conditions.