Eye motion correction algorithm for OCT-based corneal topography
Authors:
- Elias PavlatosEPElias Pavlatos
- David HuangDHDavid Huang
- Yan LiYLYan Li
- 1 December 2020
- journal article
- research article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (12) , 7343-7356
Abstract
With its sequential image acquisition, OCT-based corneal topography is often susceptible to measurement errors due to eye motion. We have developed a novel algorithm to detect eye motion and minimize its impact on OCT topography maps. We applied the eye motion correction algorithm to corneal topographic scans acquired using a 70 kHz spectral-domain OCT device. OCT corneal topographic measurements were compared to those from a rotating Scheimpflug camera topographer. The motion correction algorithm provided a 2-4 fold improvement in the repeatability of OCT topography and its agreement with the standard Scheimpflug topographer. The repeatability of OCT Zernike-based corneal mean power, cardinal astigmatism, and oblique astigmatism after motion detection was 0.14 D, 0.28 D, and 0.24 D, respectively. The average differences between the two devices were 0.19 D for simulated keratometry-based corneal mean power, 0.23 D for cardinal astigmatism, and 0.25 D for oblique astigmatism. Our eye motion detection method can be applied to any OCT device, and it therefore represents a powerful tool for improving OCT topography.Keywords
Funding Information
- National Institutes of Health (P30EY010572, R01EY028755, R01EY029023, T32EY023211)
- Optovue, Inc.
- Research to Prevent Blindness
This publication has 45 references indexed in Scilit:
- Corneal Epithelial Thickness Mapping by Fourier-Domain Optical Coherence Tomography in Normal and Keratoconic EyesOphthalmology, 2012
- Distributed scanning volumetric SDOCT for motion corrected corneal biometryBiomedical Optics Express, 2012
- Precision of sustained fixation in trained and untrained observersJournal of Vision, 2012
- Motion correction in optical coherence tomography volumes on a per A-scan basis using orthogonal scan patternsBiomedical Optics Express, 2012
- Corneal topography from spectral optical coherence tomography (sOCT)Biomedical Optics Express, 2011
- Corneal topography with high-speed swept source OCT in clinical examinationBiomedical Optics Express, 2011
- Eye movements: The past 25yearsVision Research, 2011
- Corneal imaging with slit‐scanning and Scheimpflug imaging techniquesClinical and Experimental Optometry, 2011
- Corneal power measurement with Fourier-domain optical coherence tomographyJournal of Cataract & Refractive Surgery, 2010
- Corneal Pachymetry Mapping with High-speed Optical Coherence TomographyOphthalmology, 2006