BZBowen Zheng

Bowen Zheng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bowen Zheng has a total of 31 co-authors. Here are the top co-authors by number of shared publications:

  • Jie Ren

    Department of Medical Ultrasound, Laboratory of Novel Optoacoustic (Ultrasonic) Imaging, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou 510630, China

    4 shared publications
  • Tao Wu

    Department of Radiology, Mayo Clinic, Rochester, Minnesota

    2 shared publications
  • Yufan Lian

    Department of Ultrasound, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China

    2 shared publications
  • Chen Qiu

    Department of Medical Ultrasonics Third Affiliated Hospital of Sun Yat‐sen University, Guangdong Province Key Laboratory of Hepatology Research Guangzhou China

    1 shared publication
  • Ge Tong

    Department of Medical Ultrasonics Third Affiliated Hospital of Sun Yat‐sen University, Guangdong Province Key Laboratory of Hepatology Research Guangzhou China

    1 shared publication
  • Hong‐Jun Zhang

    Department of Medical Ultrasonics Third Affiliated Hospital of Sun Yat‐sen University, Guangdong Province Key Laboratory of Hepatology Research Guangzhou China

    1 shared publication

Latest Publications

  • Open Access

    Accelerated Topology Optimization of Phononic Crystals via Deep Learning Surrogate Modeling and Simulated Annealing

    by Bowen Zheng, I-Ling Chang

    Phononic crystal (PnC) topology optimization for wide and low-frequency bandgaps is computationally demanding due to repeated finite element method (FEM) eigenvalue analyses. In this work, a surrogate-assisted optimization framework combining a convolutional neural network (CNN) with simulated annealing (SA) is developed to accelerate two-dimensional PnC design. The CNN surrogate directly predicts dispersion relations from discretized unit-cell configurations, enabling efficient bandgap evaluation without repeated FEM calculations during optimization.Using this framework, multiple PnC structures are independently optimized, each targeting a specific bandgap order. The surrogate-assisted optimization achieves optimized topologies consistent with FEM-based SA results while reducing the computational time per optimization run from several thousand minutes to approximately one minute. The surrogate model further demonstrates good generalization capability across different filling ratios and structural configurations. Overall, the proposed CNN–SA framework provides an efficient and scalable approach for inverse design of phononic crystals.

  • Open Access

    In vitro heat insulation efficacy of 5% dextrose versus 0.9% saline during radiofrequency ablation

    by Yanping Ma, Jinfen Wang, Tao Wu, Bowen Zheng, Tinghui Yin, Yufan Lian, Jie Ren

    Purpose: This study compared the efficacy of heat insulation between 5% dextrose and 0.9% saline in radiofrequency ablation (RFA). Accordingly, temperature variations and maximum temperatures were assessed at identical distances and heat field distributions.Methods: Cubes of porcine liver tissue, measuring 10 mm across, were selected to precisely align the ablation boundary with the tissue boundary. An 18-gauge electrode with a 7-mm tip was inserted into each cube (10 per group) in a stainless-steel cup containing 40 mL of 5% dextrose or 0.9% saline. Fixed ablation was performed for 3 minutes using continuous mode at 30 W, simulating the typical thermal environment during thyroid RFA. Real-time temperature measurements were recorded by sensors positioned 0, 1, 3, and 5 mm from the cube’s edge. A comparative analysis was conducted to assess the maximum temperature, temperature variation, and duration of temperatures exceeding 42℃.Results: In both groups, the temperature curve declined with increasing distance from the edge of the ablated tissue. However, 0.9% saline exhibited higher maximum temperatures at 1, 3, and 5 mm compared to 5% dextrose (1 mm: 44.55°C±5.25°C vs. 34.68°C±3.07°C; 3 mm: 39.64°C±2.53°C vs. 29.22°C±2.21°C; 5 mm: 38.86°C±2.14°C vs. 28.74°C±2.51°C; all P<0.001). Considering a nerve injury threshold of 42°C, the 0.9% saline also displayed a greater proportion of samples reaching this temperature and a longer duration of temperatures exceeding it (P<0.05).Conclusion: The heat insulation efficacy of 5% dextrose at 1-5 mm exceeds that of 0.9% saline at identical distances and in a common thermal environment during thyroid RFA.


  • Open Access

    Development and preclinical evaluation of multifunctional hydrogel for precise thermal protection during thermal ablation

    by Bowen Zheng, Peng Zhang, Qijun Lv, Tao Wu, Yadong Liu, Junjie Tang, Yanping Ma, Lili Cheng, Langtao Xu, Yizhen Wang, et al.

    Image-guided thermal ablation (TA), which is less invasive, has been widely applied for treating various kinds of tumors. However, TA still poses the potential risk of thermal damage to sensitive tissue nearby. Therefore, an adjunctive thermoprotective hydrodissection technique with constant injection of 5% glucose (5% Glu) has currently been adopted for clinical application, but this may be hazardous to humans. In this study, a multifunctional hyaluronic acid-based hydrogel (HA-Dc) was developed for hydrodissection. Compared with 5% Glu (the most clinically used solution) and the previously reported F127 hydrogel, the HA-Dc hydrogel was studied in vitro in a porcine liver model and in vivo in a rabbit model and showed good injectability and better tissue retention, stability, and thermoprotective properties throughout the TA procedure. Furthermore, in the preclinical evaluation in a Macaca fascicularis (M. fascicularis) model, HA-Dc showed excellent performance in terms of stricter neuroprotection compared with 5% Glu. In addition, the HA-Dc hydrogel with good biocompatibility and controllable degradation behavior in vivo could be a promising platform for thermal protection during clinical TA procedures.


  • Acute transient swelling of the thyroid following fine‐needle aspiration: A case series

    by Bo‐Wen Zheng, Tao Wu, Shi‐Cheng Xu, Ting‐Hui Yin, Lei Tan, Yu‐Fan Lian, Jie Ren

    Acute transient swelling (ATS) of the thyroid is a rare complication following fine‐needle aspiration (FNA) of thyroid nodules. We present 31 cases with 35 nodules encountered at our institute and reported in the literature, to provide further information. The incidence rate in our institute was 0.46%. Of these nodules, 74.3% (26/35) were solid, 65.7% (23/35) exhibited hypervascularity, and 77.2% (27/35) were benign or follicular neoplasms. Although most cases (87.1%, 27/31) occurred within 2 h after FNA, four patients experienced delayed ATS after 7 h to 2 days. Therefore, awareness of this complication, especially its delayed occurrence, should be raised.


  • Contrast‐Enhanced Ultrasound for Biliary Ischemia

    by Bo‐Wen Zheng, Tao Wu, Jin‐Xiu Ju, Li‐Li Wu, Hong‐Jun Zhang, Yu‐Fan Lian, Ge Tong, Qiao‐Jia Li, Chen Qiu, Hui‐Chao Zhou, et al.

    Objectives: Biliary perfusion is considered to contribute to biliary diseases, but routine imaging methods are insufficient to show it. This research investigated the ability of contrast‐enhanced ultrasound (CEUS) for biliary perfusion in a biliary ischemia model.Methods: This research consisted of 2 parts. First, to determine whether CEUS enhancement of the tiny biliary wall represents biliary perfusion, a vascular tracer was used as a reference to evaluate the consistency with the enhancement of the biliary wall on CEUS and the staining by the vascular tracer under the conditions of occluded and recovered biliary perfusion. In the second part, the ability of CEUS for biliary ischemia was further evaluated with microvascular density measurement as a reference. The enhancement patterns were assigned CEUS scores, in which higher scores meant more decreased enhancement, and the diagnostic ability of CEUS was assessed by a receiver operating characteristic curve analysis.Results: The biliary wall was unstained by the vascular tracer and nonenhanced on CEUS when biliary perfusion was interrupted and was stained blue and enhanced after recovery. The biliary wall in the ischemia surgery group showed lower microvascular density measurements (P < .001), decreased enhancement levels (P < .001), and higher CEUS scores (P < .001). When a CEUS score of 3 or higher (obvious decrease of the biliary wall to hypoenhancement or nonenhancement in the arterial phase or rapid wash‐out to nonenhancement in the portal venous phase) was applied, CEUS had sensitivity of 87.8%, specificity of 98.3%, accuracy of 93.8%, and an area under the receiver operating characteristic curve of 0.98.Conclusions: Contrast enhancement of the biliary wall on CEUS represents biliary perfusion and has reasonably good diagnostic performance for biliary ischemia in an experimental animal setting.