Yufan Lian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yufan Lian has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Bowen Zheng
Department of Ultrasound, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
2 shared publications - Jie Ren
Department of Medical Ultrasound, Laboratory of Novel Optoacoustic (Ultrasonic) Imaging, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou 510630, China
2 shared publications - Jinfen Wang
Department of Ultrasound, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
1 shared publication - Lei Tan
Department of Medical Ultrasonics The Third Affiliated Hospital of Sun Yat‐sen University, Guangdong Province Key Laboratory of Hepatology Research Guangzhou Guangdong China
1 shared publication Shi‐Cheng Xu
Department of Medical Ultrasonics The Third Affiliated Hospital of Sun Yat‐sen University, Guangdong Province Key Laboratory of Hepatology Research Guangzhou Guangdong China
1 shared publication- Tao Wu
Department of Medical Ultrasonics The Third Affiliated Hospital of Sun Yat‐sen University, Guangdong Province Key Laboratory of Hepatology Research Guangzhou Guangdong China
1 shared publication
Latest Publications
- Open Access
- 1 September 2024
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 43 (5) , 376-383
In vitro heat insulation efficacy of 5% dextrose versus 0.9% saline during radiofrequency ablation
Purpose: This study compared the efficacy of heat insulation between 5% dextrose and 0.9% saline in radiofrequency ablation (RFA). Accordingly, temperature variations and maximum temperatures were assessed at identical distances and heat field distributions.Methods: Cubes of porcine liver tissue, measuring 10 mm across, were selected to precisely align the ablation boundary with the tissue boundary. An 18-gauge electrode with a 7-mm tip was inserted into each cube (10 per group) in a stainless-steel cup containing 40 mL of 5% dextrose or 0.9% saline. Fixed ablation was performed for 3 minutes using continuous mode at 30 W, simulating the typical thermal environment during thyroid RFA. Real-time temperature measurements were recorded by sensors positioned 0, 1, 3, and 5 mm from the cube’s edge. A comparative analysis was conducted to assess the maximum temperature, temperature variation, and duration of temperatures exceeding 42℃.Results: In both groups, the temperature curve declined with increasing distance from the edge of the ablated tissue. However, 0.9% saline exhibited higher maximum temperatures at 1, 3, and 5 mm compared to 5% dextrose (1 mm: 44.55°C±5.25°C vs. 34.68°C±3.07°C; 3 mm: 39.64°C±2.53°C vs. 29.22°C±2.21°C; 5 mm: 38.86°C±2.14°C vs. 28.74°C±2.51°C; all P<0.001). Considering a nerve injury threshold of 42°C, the 0.9% saline also displayed a greater proportion of samples reaching this temperature and a longer duration of temperatures exceeding it (P<0.05).Conclusion: The heat insulation efficacy of 5% dextrose at 1-5 mm exceeds that of 0.9% saline at identical distances and in a common thermal environment during thyroid RFA.
- 1 September 2024
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 43 (5) , 376-383
Open AccessIn vitro heat insulation efficacy of 5% dextrose versus 0.9% saline during radiofrequency ablation
Purpose: This study compared the efficacy of heat insulation between 5% dextrose and 0.9% saline in radiofrequency ablation (RFA). Accordingly, temperature variations and maximum temperatures were assessed at identical distances and heat field distributions.Methods: Cubes of porcine liver tissue, measuring 10 mm across, were selected to precisely align the ablation boundary with the tissue boundary. An 18-gauge electrode with a 7-mm tip was inserted into each cube (10 per group) in a stainless-steel cup containing 40 mL of 5% dextrose or 0.9% saline. Fixed ablation was performed for 3 minutes using continuous mode at 30 W, simulating the typical thermal environment during thyroid RFA. Real-time temperature measurements were recorded by sensors positioned 0, 1, 3, and 5 mm from the cube’s edge. A comparative analysis was conducted to assess the maximum temperature, temperature variation, and duration of temperatures exceeding 42℃.Results: In both groups, the temperature curve declined with increasing distance from the edge of the ablated tissue. However, 0.9% saline exhibited higher maximum temperatures at 1, 3, and 5 mm compared to 5% dextrose (1 mm: 44.55°C±5.25°C vs. 34.68°C±3.07°C; 3 mm: 39.64°C±2.53°C vs. 29.22°C±2.21°C; 5 mm: 38.86°C±2.14°C vs. 28.74°C±2.51°C; all P<0.001). Considering a nerve injury threshold of 42°C, the 0.9% saline also displayed a greater proportion of samples reaching this temperature and a longer duration of temperatures exceeding it (P<0.05).Conclusion: The heat insulation efficacy of 5% dextrose at 1-5 mm exceeds that of 0.9% saline at identical distances and in a common thermal environment during thyroid RFA.
- 8 July 2021
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 50 (2) , 236-242
Acute transient swelling of the thyroid following fine‐needle aspiration: A case series
Acute transient swelling (ATS) of the thyroid is a rare complication following fine‐needle aspiration (FNA) of thyroid nodules. We present 31 cases with 35 nodules encountered at our institute and reported in the literature, to provide further information. The incidence rate in our institute was 0.46%. Of these nodules, 74.3% (26/35) were solid, 65.7% (23/35) exhibited hypervascularity, and 77.2% (27/35) were benign or follicular neoplasms. Although most cases (87.1%, 27/31) occurred within 2 h after FNA, four patients experienced delayed ATS after 7 h to 2 days. Therefore, awareness of this complication, especially its delayed occurrence, should be raised.
- 8 July 2021
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 50 (2) , 236-242
Acute transient swelling of the thyroid following fine‐needle aspiration: A case series
Acute transient swelling (ATS) of the thyroid is a rare complication following fine‐needle aspiration (FNA) of thyroid nodules. We present 31 cases with 35 nodules encountered at our institute and reported in the literature, to provide further information. The incidence rate in our institute was 0.46%. Of these nodules, 74.3% (26/35) were solid, 65.7% (23/35) exhibited hypervascularity, and 77.2% (27/35) were benign or follicular neoplasms. Although most cases (87.1%, 27/31) occurred within 2 h after FNA, four patients experienced delayed ATS after 7 h to 2 days. Therefore, awareness of this complication, especially its delayed occurrence, should be raised.