Joakim Jönsson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joakim Jönsson has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Edouard Berrocal
Lund University
4 shared publications - Haoqian Wang
Tsinghua University, Shenzhen, China
2 shared publications - Kanghyun Kim
Department of Biomedical Engineering, Duke University, Durham, NC, United States of America
2 shared publications - Kevin C. Zhou
Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, USA
2 shared publications - Lucas Kreiss
Department of Biomedical Engineering, Duke University, Durham, NC, USA
2 shared publications Paul McKee
Department of Biomedical Engineering, Duke University, Durham, NC, United States
2 shared publications
Latest Publications
- Open Access
- 8 July 2022
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 16, 908770
Transient Motion Classification Through Turbid Volumes via Parallelized Single-Photon Detection and Deep Contrastive Embedding
Fast noninvasive probing of spatially varying decorrelating events, such as cerebral blood flow beneath the human skull, is an essential task in various scientific and clinical settings. One of the primary optical techniques used is diffuse correlation spectroscopy (DCS), whose classical implementation uses a single or few single-photon detectors, resulting in poor spatial localization accuracy and relatively low temporal resolution. Here, we propose a technique termed ClassifyingRapid decorrelationEvents viaParallelized single photon dEtection (CREPE), a new form of DCS that can probe and classify different decorrelating movements hidden underneath turbid volume with high sensitivity using parallelized speckle detection from a 32 × 32 pixel SPAD array. We evaluate our setup by classifying different spatiotemporal-decorrelating patterns hidden beneath a 5 mm tissue-like phantom made with rapidly decorrelating dynamic scattering media. Twelve multi-mode fibers are used to collect scattered light from different positions on the surface of the tissue phantom. To validate our setup, we generate perturbed decorrelation patterns by both a digital micromirror device (DMD) modulated at multi-kilo-hertz rates, as well as a vessel phantom containing flowing fluid. Along with a deep contrastive learning algorithm that outperforms classic unsupervised learning methods, we demonstrate our approach can accurately detect and classify different transient decorrelation events (happening in 0.1–0.4 s) underneath turbid scattering media, without any data labeling. This has the potential to be applied to non-invasively monitor deep tissue motion patterns, for example identifying normal or abnormal cerebral blood flow events, at multi-Hertz rates within a compact and static detection probe.
- 8 July 2022
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 16, 908770
Open AccessTransient Motion Classification Through Turbid Volumes via Parallelized Single-Photon Detection and Deep Contrastive Embedding
Fast noninvasive probing of spatially varying decorrelating events, such as cerebral blood flow beneath the human skull, is an essential task in various scientific and clinical settings. One of the primary optical techniques used is diffuse correlation spectroscopy (DCS), whose classical implementation uses a single or few single-photon detectors, resulting in poor spatial localization accuracy and relatively low temporal resolution. Here, we propose a technique termed ClassifyingRapid decorrelationEvents viaParallelized single photon dEtection (CREPE), a new form of DCS that can probe and classify different decorrelating movements hidden underneath turbid volume with high sensitivity using parallelized speckle detection from a 32 × 32 pixel SPAD array. We evaluate our setup by classifying different spatiotemporal-decorrelating patterns hidden beneath a 5 mm tissue-like phantom made with rapidly decorrelating dynamic scattering media. Twelve multi-mode fibers are used to collect scattered light from different positions on the surface of the tissue phantom. To validate our setup, we generate perturbed decorrelation patterns by both a digital micromirror device (DMD) modulated at multi-kilo-hertz rates, as well as a vessel phantom containing flowing fluid. Along with a deep contrastive learning algorithm that outperforms classic unsupervised learning methods, we demonstrate our approach can accurately detect and classify different transient decorrelation events (happening in 0.1–0.4 s) underneath turbid scattering media, without any data labeling. This has the potential to be applied to non-invasively monitor deep tissue motion patterns, for example identifying normal or abnormal cerebral blood flow events, at multi-Hertz rates within a compact and static detection probe.
- Open Access
Transient motion classification through turbid volumes via parallelized single-photon detection and deep contrastive embedding
Fast noninvasive probing of spatially varying decorrelating events, such as cerebral blood flow beneath the human skull, is an essential task in various scientific and clinical settings. One of the primary optical techniques used is diffuse correlation spectroscopy (DCS), whose classical implementation uses a single or few single-photon detectors, resulting in poor spatial localization accuracy and relatively low temporal resolution. Here, we propose a technique termed Classifying Rapid decorrelation Events via Parallelized single photon dEtection (CREPE)}, a new form of DCS that can probe and classify different decorrelating movements hidden underneath turbid volume with high sensitivity using parallelized speckle detection from a $32\times32$ pixel SPAD array. We evaluate our setup by classifying different spatiotemporal-decorrelating patterns hidden beneath a 5mm tissue-like phantom made with rapidly decorrelating dynamic scattering media. Twelve multi-mode fibers are used to collect scattered light from different positions on the surface of the tissue phantom. To validate our setup, we generate perturbed decorrelation patterns by both a digital micromirror device (DMD) modulated at multi-kilo-hertz rates, as well as a vessel phantom containing flowing fluid. Along with a deep contrastive learning algorithm that outperforms classic unsupervised learning methods, we demonstrate our approach can accurately detect and classify different transient decorrelation events (happening in 0.1-0.4s) underneath turbid scattering media, without any data labeling. This has the potential to be applied to noninvasively monitor deep tissue motion patterns, for example identifying normal or abnormal cerebral blood flow events, at multi-Hertz rates within a compact and static detection probe.Open AccessTransient motion classification through turbid volumes via parallelized single-photon detection and deep contrastive embedding
Fast noninvasive probing of spatially varying decorrelating events, such as cerebral blood flow beneath the human skull, is an essential task in various scientific and clinical settings. One of the primary optical techniques used is diffuse correlation spectroscopy (DCS), whose classical implementation uses a single or few single-photon detectors, resulting in poor spatial localization accuracy and relatively low temporal resolution. Here, we propose a technique termed Classifying Rapid decorrelation Events via Parallelized single photon dEtection (CREPE)}, a new form of DCS that can probe and classify different decorrelating movements hidden underneath turbid volume with high sensitivity using parallelized speckle detection from a $32\times32$ pixel SPAD array. We evaluate our setup by classifying different spatiotemporal-decorrelating patterns hidden beneath a 5mm tissue-like phantom made with rapidly decorrelating dynamic scattering media. Twelve multi-mode fibers are used to collect scattered light from different positions on the surface of the tissue phantom. To validate our setup, we generate perturbed decorrelation patterns by both a digital micromirror device (DMD) modulated at multi-kilo-hertz rates, as well as a vessel phantom containing flowing fluid. Along with a deep contrastive learning algorithm that outperforms classic unsupervised learning methods, we demonstrate our approach can accurately detect and classify different transient decorrelation events (happening in 0.1-0.4s) underneath turbid scattering media, without any data labeling. This has the potential to be applied to noninvasively monitor deep tissue motion patterns, for example identifying normal or abnormal cerebral blood flow events, at multi-Hertz rates within a compact and static detection probe. - 4 January 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (2) , 1261-1279
Multi-scattering software part II: experimental validation for the light intensity distribution
This article, Part II of an article series on GPU-accelerated Monte Carlo simulation of photon transport through turbid media, focuses on the validation of the online software Multi-Scattering. While Part I detailed the implementation of the computational model, simulated and experimental results are now compared for the distribution of the scattered light intensity. The scattering phantoms prepared here are aqueous dispersions of polystyrene microspheres of diameter D = 0.5, 2 and 5 μm and at various concentrations, resulting in optical depth ranging from OD = 1 to 17.5. The Lorenz-Mie scattering phase functions used in the simulations have been verified experimentally at low particle concentrations by analyzing the angular light intensity distribution at the Fourier plane of a collecting lens. The validation approach herein accounts for the specific light collection and image formation by the camera. The front and side surfaces of the medium are imaged and the corresponding light intensity distributions are compared qualitatively and quantitatively. It is concluded that the model enables reliable simulations over the tested parameters, offering predictive simulations of transmitted intensities with a mean relative error ≤~19% over the full range. The online software is available at: https://multi-scattering.com/
- 4 January 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (2) , 1261-1279
Multi-scattering software part II: experimental validation for the light intensity distribution
This article, Part II of an article series on GPU-accelerated Monte Carlo simulation of photon transport through turbid media, focuses on the validation of the online software Multi-Scattering. While Part I detailed the implementation of the computational model, simulated and experimental results are now compared for the distribution of the scattered light intensity. The scattering phantoms prepared here are aqueous dispersions of polystyrene microspheres of diameter D = 0.5, 2 and 5 μm and at various concentrations, resulting in optical depth ranging from OD = 1 to 17.5. The Lorenz-Mie scattering phase functions used in the simulations have been verified experimentally at low particle concentrations by analyzing the angular light intensity distribution at the Fourier plane of a collecting lens. The validation approach herein accounts for the specific light collection and image formation by the camera. The front and side surfaces of the medium are imaged and the corresponding light intensity distributions are compared qualitatively and quantitatively. It is concluded that the model enables reliable simulations over the tested parameters, offering predictive simulations of transmitted intensities with a mean relative error ≤~19% over the full range. The online software is available at: https://multi-scattering.com/
- 1 December 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (25) , 37612-37638
Multi-Scattering software: part I: online accelerated Monte Carlo simulation of light transport through scattering media
In this article we present and describe an online freely accessible software called Multi-Scattering for the modeling of light propagation in scattering and absorbing media. Part II of this article series focuses on the validation of the model by rigorously comparing the simulated results with experimental data. The model is based on the use of the Monte Carlo method, where billions of photon packets are being tracked through simulated cubic volumes. Simulations are accelerated by the use of general-purpose computing on graphics processing units, reducing the computation time by a factor up to 200x in comparison with a single central processing unit thread. By using four graphic cards on a single computer, the simulation speed increases by a factor of 800x. For an anisotropy factor g = 0.86, this enables the transport path of one billion photons to be computed in 10 seconds for optical depth OD = 10 and in 20 minutes for OD = 500. Another feature of Multi-Scattering is the integration and implementation of the Lorenz-Mie theory in the software to generate the scattering phase functions from spherical particles. The simulations are run from a computer server at Lund University, allowing researchers to log in and use it freely without any prior need for programming skills or specific software/hardware installations. There are countless types of scattering media in which this model can be used to predict light transport, including medical tissues, blood samples, clouds, smoke, fog, turbid liquids, spray systems, etc. An example of simulation results is given here for photon propagation through a piece of human head. The software also includes features for modeling image formation by inserting a virtual collecting lens and a detection matrix which simulate a camera objective and a sensor array respectively. The user interface for setting-up simulations and for displaying the corresponding results is found at: https://multi-scattering.com/.
- 1 December 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (25) , 37612-37638
Multi-Scattering software: part I: online accelerated Monte Carlo simulation of light transport through scattering media
In this article we present and describe an online freely accessible software called Multi-Scattering for the modeling of light propagation in scattering and absorbing media. Part II of this article series focuses on the validation of the model by rigorously comparing the simulated results with experimental data. The model is based on the use of the Monte Carlo method, where billions of photon packets are being tracked through simulated cubic volumes. Simulations are accelerated by the use of general-purpose computing on graphics processing units, reducing the computation time by a factor up to 200x in comparison with a single central processing unit thread. By using four graphic cards on a single computer, the simulation speed increases by a factor of 800x. For an anisotropy factor g = 0.86, this enables the transport path of one billion photons to be computed in 10 seconds for optical depth OD = 10 and in 20 minutes for OD = 500. Another feature of Multi-Scattering is the integration and implementation of the Lorenz-Mie theory in the software to generate the scattering phase functions from spherical particles. The simulations are run from a computer server at Lund University, allowing researchers to log in and use it freely without any prior need for programming skills or specific software/hardware installations. There are countless types of scattering media in which this model can be used to predict light transport, including medical tissues, blood samples, clouds, smoke, fog, turbid liquids, spray systems, etc. An example of simulation results is given here for photon propagation through a piece of human head. The software also includes features for modeling image formation by inserting a virtual collecting lens and a detection matrix which simulate a camera objective and a sensor array respectively. The user interface for setting-up simulations and for displaying the corresponding results is found at: https://multi-scattering.com/.
- Open Access
- 28 November 2018
- Published by Springer Nature in Journal of Radiation Oncology
- Vol. 7 (4) , 357-366
Inter-fraction movements of the prostate and pelvic lymph nodes during IGRT
Objectivities The aim of this study was to evaluate inter-fraction movements of lymph node regions that are commonly included in the pelvic clinical target volume (CTV) for high-risk prostate cancer patients. We also aimed to evaluate if the movements affect the planning target volumes. Methods Ten prostate cancer patients were included. The patients underwent six MRI scans, from treatment planning to near end of treatment. The CTV movements were analyzed with deformable registration technique with the CTV divided into sections. The validity of the deformable registration was assessed by comparing the results for individual lymph nodes that were possible to identify in all scans. Results Using repetitive MRI, measurements showed that areas inside the CTV (lymph nodes) in some extreme cases were as mobile as the prostate and not fixed to the bones. The lymph node volumes closest to the prostate did not tend to follow the prostate motion. The more cranial lymph node volumes moved less, but still independently, and they were not necessarily fixed to the pelvic bones. In 95% of the cases, the lymph node motion in the R-L direction was 2–4 mm, in the A-P direction 2–7 mm, and in the C-C direction 2–5 mm depending on the CTV section. Conclusion Lymph nodes and prostate were most mobile in the A-P direction, followed by the C-C and R-L directions. This movement should be taken into account when deciding the margins for the planning target volumes (PTV).
- 28 November 2018
- Published by Springer Nature in Journal of Radiation Oncology
- Vol. 7 (4) , 357-366
Open AccessInter-fraction movements of the prostate and pelvic lymph nodes during IGRT
Objectivities The aim of this study was to evaluate inter-fraction movements of lymph node regions that are commonly included in the pelvic clinical target volume (CTV) for high-risk prostate cancer patients. We also aimed to evaluate if the movements affect the planning target volumes. Methods Ten prostate cancer patients were included. The patients underwent six MRI scans, from treatment planning to near end of treatment. The CTV movements were analyzed with deformable registration technique with the CTV divided into sections. The validity of the deformable registration was assessed by comparing the results for individual lymph nodes that were possible to identify in all scans. Results Using repetitive MRI, measurements showed that areas inside the CTV (lymph nodes) in some extreme cases were as mobile as the prostate and not fixed to the bones. The lymph node volumes closest to the prostate did not tend to follow the prostate motion. The more cranial lymph node volumes moved less, but still independently, and they were not necessarily fixed to the pelvic bones. In 95% of the cases, the lymph node motion in the R-L direction was 2–4 mm, in the A-P direction 2–7 mm, and in the C-C direction 2–5 mm depending on the CTV section. Conclusion Lymph nodes and prostate were most mobile in the A-P direction, followed by the C-C and R-L directions. This movement should be taken into account when deciding the margins for the planning target volumes (PTV).