Edmond Olguin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Edmond Olguin has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Stephanie M. Leon
Department of Radiology University of Florida Gainesville Florida USA
2 shared publications A Gonzales
14 Universidad Tecnológica del Peru—Lima, Peru
1 shared publicationA Necas
TAE Technologies, Foothill Ranch, CA 92610, United States of America
1 shared publicationA Shankar
Department of Radiology, University of Florida, Gainesville, FL 32610, United States of America
1 shared publicationB Hamrick
Environmental Health and Safety, University of California, Irvine Health, Orange, CA 92868, United States of America
1 shared publicationB Li
Department of Radiation Oncology, University of California, San Francisco, CA 94115, United States of America
1 shared publication
Latest Publications
- Open Access
- 23 April 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (5) , e70597
Deep learning “super resolution” versus iterative reconstruction: Phantom‐based image quality assessment
Background: Deep learning reconstruction (DLR) algorithms have begun replacing iterative reconstruction (IR) in CT. Besides the potential to reduce noise, the application of artificial intelligence can also allow for “super resolution,” allowing traditional CT systems to produce images with improved spatial resolution by training against higher‐resolution images. This study aims to characterize the image quality produced by a DLR “super resolution” algorithm. Purpose: This study compares Canon's Precise IQ Engine (PIQE) Cardiac, a DLR algorithm, with the AIDR Enhanced 3D iterative reconstruction (IR) algorithm using quantitative phantom‐based image quality measurements. Materials and methods: Scans of the American College of Radiology (ACR) Gammex 464 image quality phantom with and without a torso‐sized elliptical ring were acquired using CTDI vol of 2.6, 15.7, and 32.9 mGy. Each experimental condition was scanned 20 times. Reconstructions used AIDR with a cardiac kernel and PIQE Cardiac with both 512 × 512 and 1024 × 1024 matrices. The task‐based modulation transfer function (MTF task ) was calculated for Teflon, acrylic, polyethylene, and air inserts. Contrast‐to‐noise ratio (CNR) and low‐contrast object specific CNR (CNR LO ) were calculated for the 25‐mm and 6‐mm low‐contrast disks in module 2 of the phantom. NPS and noise magnitude were calculated from the module's background. Results: Both versions of PIQE showed improvement in MTF task over AIDR for most frequencies, with PIQE 1024 outperforming PIQE 512. Larger differences were noted at higher contrast levels and with the smaller phantom. NPS curves for PIQE 512 and PIQE 1024 were nearly identical at all doses. AIDR showed a noise magnitude at least 44% higher than PIQE for all scenarios. The NPS shapes differed between AIDR and PIQE, producing noticeably different noise textures that were dose‐ and phantom size‐dependent. CNR LO values were similar between PIQE 512 and PIQE 1024 and were higher than those of AIDR for most scenarios; however, AIDR outperformed PIQE for the 6‐mm objects at the medium and high doses. Use of PIQE on the 25‐mm disk permits dose reductions in the small phantom without loss of CNR LO . Conclusion: PIQE provides substantial image quality improvements over AIDR in phantom‐based quantitative measurements. The potential for dose reduction is also noted. PIQE 1024 can be used to improve the spatial resolution over PIQE 512, with no apparent trade‐offs in image quality.
- 23 April 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (5) , e70597
Open AccessDeep learning “super resolution” versus iterative reconstruction: Phantom‐based image quality assessment
Background: Deep learning reconstruction (DLR) algorithms have begun replacing iterative reconstruction (IR) in CT. Besides the potential to reduce noise, the application of artificial intelligence can also allow for “super resolution,” allowing traditional CT systems to produce images with improved spatial resolution by training against higher‐resolution images. This study aims to characterize the image quality produced by a DLR “super resolution” algorithm. Purpose: This study compares Canon's Precise IQ Engine (PIQE) Cardiac, a DLR algorithm, with the AIDR Enhanced 3D iterative reconstruction (IR) algorithm using quantitative phantom‐based image quality measurements. Materials and methods: Scans of the American College of Radiology (ACR) Gammex 464 image quality phantom with and without a torso‐sized elliptical ring were acquired using CTDI vol of 2.6, 15.7, and 32.9 mGy. Each experimental condition was scanned 20 times. Reconstructions used AIDR with a cardiac kernel and PIQE Cardiac with both 512 × 512 and 1024 × 1024 matrices. The task‐based modulation transfer function (MTF task ) was calculated for Teflon, acrylic, polyethylene, and air inserts. Contrast‐to‐noise ratio (CNR) and low‐contrast object specific CNR (CNR LO ) were calculated for the 25‐mm and 6‐mm low‐contrast disks in module 2 of the phantom. NPS and noise magnitude were calculated from the module's background. Results: Both versions of PIQE showed improvement in MTF task over AIDR for most frequencies, with PIQE 1024 outperforming PIQE 512. Larger differences were noted at higher contrast levels and with the smaller phantom. NPS curves for PIQE 512 and PIQE 1024 were nearly identical at all doses. AIDR showed a noise magnitude at least 44% higher than PIQE for all scenarios. The NPS shapes differed between AIDR and PIQE, producing noticeably different noise textures that were dose‐ and phantom size‐dependent. CNR LO values were similar between PIQE 512 and PIQE 1024 and were higher than those of AIDR for most scenarios; however, AIDR outperformed PIQE for the 6‐mm objects at the medium and high doses. Use of PIQE on the 25‐mm disk permits dose reductions in the small phantom without loss of CNR LO . Conclusion: PIQE provides substantial image quality improvements over AIDR in phantom‐based quantitative measurements. The potential for dose reduction is also noted. PIQE 1024 can be used to improve the spatial resolution over PIQE 512, with no apparent trade‐offs in image quality.
- 5 September 2022
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (6) , 065004
Low-dose radiotherapy to the lungs using an interventional radiology C-arm fluoroscope: Monte Carlo treatment planning and dose measurements in a postmortem subject
Objective. The goal of this study was to use Monte Carlo (MC) simulations and measurements to investigate the dosimetric suitability of an interventional radiology (IR) c-arm fluoroscope to deliver low-dose radiotherapy to the lungs. Approach. A previously-validated MC model of an IR fluoroscope was used to calculate the dose distributions in a COVID-19-infected patient, 20 non-infected patients of varying sizes, and a postmortem subject. Dose distributions for PA, AP/PA, 3-field and 4-field treatments irradiating 95% of the lungs to a 0.5 Gy dose were calculated. An algorithm was created to calculate skin entrance dose as a function of patient thickness for treatment planning purposes. Treatments were experimentally validated in a postmortem subject by using implanted dosimeters to capture organ doses. Main results. Mean doses to the left/right lungs for the COVID-19 CT data were 1.2/1.3 Gy, 0.8/0.9 Gy, 0.8/0.8 Gy and 0.6/0.6 Gy for the PA, AP/PA, 3-field, and 4-field configurations, respectively. Skin dose toxicity was the highest probability for the PA and lowest for the 4-field configuration. Dose to the heart slightly exceeded the ICRP tolerance; all other organ doses were below published tolerances. The AP/PA configuration provided the best fit for entrance skin dose as a function of patient thickness (R 2 = 0.8). The average dose difference between simulation and measurement in the postmortem subject was 5%. Significance. An IR fluoroscope should be capable of delivering low-dose radiotherapy to the lungs with tolerable collateral dose to nearby organs.
- 5 September 2022
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (6) , 065004
Low-dose radiotherapy to the lungs using an interventional radiology C-arm fluoroscope: Monte Carlo treatment planning and dose measurements in a postmortem subject
Objective. The goal of this study was to use Monte Carlo (MC) simulations and measurements to investigate the dosimetric suitability of an interventional radiology (IR) c-arm fluoroscope to deliver low-dose radiotherapy to the lungs. Approach. A previously-validated MC model of an IR fluoroscope was used to calculate the dose distributions in a COVID-19-infected patient, 20 non-infected patients of varying sizes, and a postmortem subject. Dose distributions for PA, AP/PA, 3-field and 4-field treatments irradiating 95% of the lungs to a 0.5 Gy dose were calculated. An algorithm was created to calculate skin entrance dose as a function of patient thickness for treatment planning purposes. Treatments were experimentally validated in a postmortem subject by using implanted dosimeters to capture organ doses. Main results. Mean doses to the left/right lungs for the COVID-19 CT data were 1.2/1.3 Gy, 0.8/0.9 Gy, 0.8/0.8 Gy and 0.6/0.6 Gy for the PA, AP/PA, 3-field, and 4-field configurations, respectively. Skin dose toxicity was the highest probability for the PA and lowest for the 4-field configuration. Dose to the heart slightly exceeded the ICRP tolerance; all other organ doses were below published tolerances. The AP/PA configuration provided the best fit for entrance skin dose as a function of patient thickness (R 2 = 0.8). The average dose difference between simulation and measurement in the postmortem subject was 5%. Significance. An IR fluoroscope should be capable of delivering low-dose radiotherapy to the lungs with tolerable collateral dose to nearby organs.
- 24 November 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (23) , 235015
Specific absorbed fractions and radionuclide S-values for tumors of varying size and composition
Accurate estimates of tumor absorbed dose are essential for the evaluation of treatment efficacy in radiopharmaceutical cancer therapy. Although tumor dosimetry via the MIRD schema has been previously investigated, prior studies have been limited to the consideration of soft-tissue tumors. In the present study, specific absorbed fractions (SAFs) for monoenergetic photons, electrons, and alpha particles in tumors of varying compositions were computed using Monte Carlo simulations in MCNPX after which self-irradiation S-values for 22 radionuclides (along with 14 additional alpha-emitter progeny) were generated for tumors of both varying size and tissue composition. The tumors were modeled as spheres with radii ranging from 0.10 cm to 6.0 cm and with compositions varying from 100% soft tissue (ST) to 100% mineral bone (MB). The energies of the photons and electrons were varied on a logarithm energy grid from 10 keV to 10 MeV. The energies of alpha particles were varied along a linear energy grid from 0.5 MeV to 12 MeV. In all cases, a homogenous activity distribution was assumed throughout the tumor volume. Furthermore, to assess the effect of tumor shape, several ellipsoidal tumors of different compositions were modeled and absorbed fractions were computed for monoenergetic electrons and photons. S-values were then generated using detailed decay data from the 2008 MIRD Monograph on Radionuclide Data and Decay Schemes. Our study results demonstrate that a soft-tissue model yields relative errors of 25% and 71% in the absorbed fraction assigned to uniform sources of 1.5 MeV electrons and 100 keV photons, respectively, localized within a 1 cm diameter tumor of MB. The data further show that absorbed fractions for moderate ellipsoids can be well approximated by a spherical shape of equal mass within a relative error of < 8%. S-values for 22 radionuclides (and their daughter progeny) were computed with results demonstrating how relative errors in SAFs could propagate to relative errors in tumor dose estimates as high as 86%. A comprehensive data set of radionuclide S-values by tumor size and tissue composition is provided for application of the MIRD schema for tumor dosimetry in radiopharmaceutical therapy.
- 24 November 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (23) , 235015
Specific absorbed fractions and radionuclide S-values for tumors of varying size and composition
Accurate estimates of tumor absorbed dose are essential for the evaluation of treatment efficacy in radiopharmaceutical cancer therapy. Although tumor dosimetry via the MIRD schema has been previously investigated, prior studies have been limited to the consideration of soft-tissue tumors. In the present study, specific absorbed fractions (SAFs) for monoenergetic photons, electrons, and alpha particles in tumors of varying compositions were computed using Monte Carlo simulations in MCNPX after which self-irradiation S-values for 22 radionuclides (along with 14 additional alpha-emitter progeny) were generated for tumors of both varying size and tissue composition. The tumors were modeled as spheres with radii ranging from 0.10 cm to 6.0 cm and with compositions varying from 100% soft tissue (ST) to 100% mineral bone (MB). The energies of the photons and electrons were varied on a logarithm energy grid from 10 keV to 10 MeV. The energies of alpha particles were varied along a linear energy grid from 0.5 MeV to 12 MeV. In all cases, a homogenous activity distribution was assumed throughout the tumor volume. Furthermore, to assess the effect of tumor shape, several ellipsoidal tumors of different compositions were modeled and absorbed fractions were computed for monoenergetic electrons and photons. S-values were then generated using detailed decay data from the 2008 MIRD Monograph on Radionuclide Data and Decay Schemes. Our study results demonstrate that a soft-tissue model yields relative errors of 25% and 71% in the absorbed fraction assigned to uniform sources of 1.5 MeV electrons and 100 keV photons, respectively, localized within a 1 cm diameter tumor of MB. The data further show that absorbed fractions for moderate ellipsoids can be well approximated by a spherical shape of equal mass within a relative error of < 8%. S-values for 22 radionuclides (and their daughter progeny) were computed with results demonstrating how relative errors in SAFs could propagate to relative errors in tumor dose estimates as high as 86%. A comprehensive data set of radionuclide S-values by tumor size and tissue composition is provided for application of the MIRD schema for tumor dosimetry in radiopharmaceutical therapy.