    Deep learning “super resolution” versus iterative reconstruction: Phantom‐based image quality assessment

    by Stephanie M. Leon, Daniella Fabri, Colin J. Schaeffer, Edmond A. Olguin

    Background: Deep learning reconstruction (DLR) algorithms have begun replacing iterative reconstruction (IR) in CT. Besides the potential to reduce noise, the application of artificial intelligence can also allow for “super resolution,” allowing traditional CT systems to produce images with improved spatial resolution by training against higher‐resolution images. This study aims to characterize the image quality produced by a DLR “super resolution” algorithm. Purpose: This study compares Canon's Precise IQ Engine (PIQE) Cardiac, a DLR algorithm, with the AIDR Enhanced 3D iterative reconstruction (IR) algorithm using quantitative phantom‐based image quality measurements. Materials and methods: Scans of the American College of Radiology (ACR) Gammex 464 image quality phantom with and without a torso‐sized elliptical ring were acquired using CTDI vol of 2.6, 15.7, and 32.9 mGy. Each experimental condition was scanned 20 times. Reconstructions used AIDR with a cardiac kernel and PIQE Cardiac with both 512 × 512 and 1024 × 1024 matrices. The task‐based modulation transfer function (MTF task ) was calculated for Teflon, acrylic, polyethylene, and air inserts. Contrast‐to‐noise ratio (CNR) and low‐contrast object specific CNR (CNR LO ) were calculated for the 25‐mm and 6‐mm low‐contrast disks in module 2 of the phantom. NPS and noise magnitude were calculated from the module's background. Results: Both versions of PIQE showed improvement in MTF task over AIDR for most frequencies, with PIQE 1024 outperforming PIQE 512. Larger differences were noted at higher contrast levels and with the smaller phantom. NPS curves for PIQE 512 and PIQE 1024 were nearly identical at all doses. AIDR showed a noise magnitude at least 44% higher than PIQE for all scenarios. The NPS shapes differed between AIDR and PIQE, producing noticeably different noise textures that were dose‐ and phantom size‐dependent. CNR LO values were similar between PIQE 512 and PIQE 1024 and were higher than those of AIDR for most scenarios; however, AIDR outperformed PIQE for the 6‐mm objects at the medium and high doses. Use of PIQE on the 25‐mm disk permits dose reductions in the small phantom without loss of CNR LO . Conclusion: PIQE provides substantial image quality improvements over AIDR in phantom‐based quantitative measurements. The potential for dose reduction is also noted. PIQE 1024 can be used to improve the spatial resolution over PIQE 512, with no apparent trade‐offs in image quality.


  • Open Access

    AAPM Task Group No. 249.B—Essentials and guidelines for clinical medical physics residency training programs

    by Jonathon A. Nye, Joseph P. Dugas, William D. Erwin, David P. Gierga, Darryl G. Kaurin, Stephanie M. Leon, Ho‐Ling Anthony Liu, Zheng Feng Lu, Alphonso W. Magri, Lynn N. Rill, et al.

    The establishment of guidelines and curriculum standards for medical physics residency training is a critical component of setting expectations and competencies for the profession. Since the last publication of these standards, residency training has become integrated into the eligibility criteria for most medical physics certification bodies. The rapid growth of medical physics requires periodic review of the curriculum to remove outdated approaches, update established knowledge, and add emerging technologies. The goal of this document is to provide a reference standard for residency training program directors, training mentors, and residents to guide creation and/or optimization of their program's curriculum. The document is intentionally forward‐looking to capture emerging technological advances including hybrid diagnostic and therapeutic delivery systems and applications of image processing. This document is an update of the current residency training curriculum.Version history of residency training guidelinesPublication TitleDate2013 Essentials and Guidelines for Clinical Medical Physics Residency Training Programs—AAPM Report No. 2492006 Essentials and Guidelines for Hospital‐Based Medical Physics Residency Training Programs—Report No. 901992 Essentials and Guidelines for Hospital‐Based Medical Physics Residency Training Programs—Report No. 36The Work Group on Periodic Review of Medical Physics Residency Training (WGMPRT) would like to acknowledge the authors of past versions of this document as they form the basis for this update. It is the sincere hope of the WGMPRT that this report will continue to be used by the medical physics community to guide training in the profession.


  • Open Access

    Shielding resources for four common radiopharmaceuticals utilized for imaging and therapy: Tc‐99m, F‐18, I‐131, and Lu‐177

    by Michael Oumano, Richard Wendt, James Botti, Nathan Busse, David Hintenlang, Stephanie Leon, Kevin Little, Melissa Martin, Richard Massoth, Kenneth Matthews, et al.

    Introduction: The use of radioactive materials in the United States has been tightly regulated by the Nuclear Regulatory Commission and other entities for many decades. In 2015, however, the Joint Commission began to require hospital‐based nuclear medicine departments to conduct shielding designs and evaluations for radioactive material areas, mirroring established x‐ray practices. NCRP Report No. 147 guides diagnostic medical x‐ray shielding, but obviously cannot be used alone for nuclear medicine applications. The rising demand for theranostic nuclear medicine shielding evaluations particularly necessitates updated focused guidance, the aim of this report.Methods: Monte Carlo simulations were conducted using GATE software to analyze the effects of various barriers on the transmission of radioactive emissions. The simulations used point sources of Tc‐99m, F‐18, I‐131, and Lu‐177 and evaluated dose deposition to blocks of tissue using Dose Actors. Different ceiling heights (ranging from 10–16 feet) were also tested for scattering effects. The Archer equation was employed to fit transmission curves and estimate required barrier thicknesses.Results: Broad beam transmission factors and Archer fitting parameters are reported for various materials including lead, gypsum, concrete (light weight and normal weight), glass, and steel. A sample shielding calculation is provided for a wall separating Lu‐177 dotatate patients from an adjacent office to maintain public dose limits. Relevant occupancy factors are also provided.Conclusions: While Lu‐177 has a relatively low exposure rate constant, shielding may be necessary for high‐volume therapies like Lu‐177 DOTATATE and Lu‐177 vipivotide tetraxetan PSMA. Shielding involves accounting for broad radiation beams and requires thorough characterization of radiation buildup. When shielding to the typical height of 7 feet, scatter from ceilings and floors is negligible for transmission above 10%, but severely limits the ability to shield for transmission below 1%.


  • Low-dose radiotherapy to the lungs using an interventional radiology C-arm fluoroscope: Monte Carlo treatment planning and dose measurements in a postmortem subject

    by S Leon, O Paucar, N Correa, M Glassell, A Gonzales, E Olguin, A Shankar, V Moskvin, B Schwarz, M Alva-Sanchez, et al.

    Objective. The goal of this study was to use Monte Carlo (MC) simulations and measurements to investigate the dosimetric suitability of an interventional radiology (IR) c-arm fluoroscope to deliver low-dose radiotherapy to the lungs. Approach. A previously-validated MC model of an IR fluoroscope was used to calculate the dose distributions in a COVID-19-infected patient, 20 non-infected patients of varying sizes, and a postmortem subject. Dose distributions for PA, AP/PA, 3-field and 4-field treatments irradiating 95% of the lungs to a 0.5 Gy dose were calculated. An algorithm was created to calculate skin entrance dose as a function of patient thickness for treatment planning purposes. Treatments were experimentally validated in a postmortem subject by using implanted dosimeters to capture organ doses. Main results. Mean doses to the left/right lungs for the COVID-19 CT data were 1.2/1.3 Gy, 0.8/0.9 Gy, 0.8/0.8 Gy and 0.6/0.6 Gy for the PA, AP/PA, 3-field, and 4-field configurations, respectively. Skin dose toxicity was the highest probability for the PA and lowest for the 4-field configuration. Dose to the heart slightly exceeded the ICRP tolerance; all other organ doses were below published tolerances. The AP/PA configuration provided the best fit for entrance skin dose as a function of patient thickness (R 2 = 0.8). The average dose difference between simulation and measurement in the postmortem subject was 5%. Significance. An IR fluoroscope should be capable of delivering low-dose radiotherapy to the lungs with tolerable collateral dose to nearby organs.

  • Comparison of CT image quality between the AIDR 3D and FIRST iterative reconstruction algorithms: an assessment based on phantom measurements and clinical images

    by Stephanie M Leon, Edmond Olguin, Colin J Schaeffer, Catherine Olguin, Nupur Verma, Tan-Lucien H Mohammed, Joseph R Grajo, Manuel M Arreola

    Modern CT iterative reconstruction algorithms are transitioning from a statistical-based to model-based approach. However, increasing complexity does not ensure improved image quality for all indications, and thorough characterization of new algorithms is important to understand their potential clinical impacts. This study performs both quantitative and qualitative analyses of image quality to compare Canon’s statistical-based Adaptive Iterative Dose Reduction 3D (AIDR 3D) algorithm to its model-based algorithm, Forward-projected model-based Iterative Reconstruction SoluTion(FIRST). A phantom was used to measure the task-specific modulation transfer function (MTF Task ), the noise power spectrum (NPS), and the low-contrast object-specific CNR (CNR LO ) for each algorithm using three dose levels and the convolution algorithm (kernel) appropriate for abdomen, lung, and brain imaging. Additionally, MTF Task was measured at four contrast levels, and CNR LO was measured for two object sizes. Lastly, three radiologists participated in a preference study to compare clinical image quality for three study types: non-contrast abdomen, pulmonary embolism (PE), and lung screening. Nine questions related to the appearance of anatomical features or image quality characteristics were scored for twenty exams of each type. The behavior of both algorithms depended strongly on the kernel selected. Phantom measurements suggest that FIRST should be beneficial over AIDR 3D for abdomen imaging, but do not suggest a clear overall benefit to FIRST for lung or brain imaging; metrics suggest performance may be equivalent to or slightly favor AIDR 3D, depending on the size of the object being imaged and whether spatial resolution or low-contrast resolution is more important for the task at hand. Overall, radiologists strongly preferred AIDR 3D for lung screening, slightly preferred AIDR 3D for non-contrast abdomen, and had no preference for PE. FIRST was superior for the reduction of metal artifacts. Radiologist preference may be influenced by changes to noise texture.


  • Accuracy and reproducibility of effective atomic number and electron density measurements from sequential dual energy CT

    by Colin J. Schaeffer, Stephanie M. Leon, Catherine A. Olguin, Manuel M. Arreola

    Purpose: This study assesses the accuracy of effective atomic number (Zeff) and electron density measurements acquired from dual energy CT and characterizes the response to clinically relevant variables representative of challenges in patient imaging, including: phantom size, material position within the phantom, variation over time, off‐center positioning, and large cone beam angle.Methods: The Gammex Multi‐Energy CT head and body phantoms were used to measure Zeff and electron density from 35 rod inserts that mimic tissues and varying concentrations of iodine and calcium. Scans were performed on a Canon Aquilion ONE Genesis CT scanner over a period of 6 months using default dual energy protocols appropriate for each phantom size. Theoretical Zeff and electron density values were calculated using data provided by the phantom manufacturer and compared to the measurements. Sources of variance were separated and quantified to identify the influences of random photon statistics, ROI placement, and variation over time. A subset of measurements were repeated with the phantom shifted in the vertical and horizontal directions, and over all slices in the volumetric scan.Results: All measurements showed strong correlation (r > 0.98) with their corresponding theoretical values; however, the system did demonstrate a bias of −0.58 atomic units in the body phantom and 0.28 atomic units in the head phantom for Zeff measurements. The mean absolute percent error (MAPE) was 6.3% for the body phantom and 3.2% for the head phantom. Electron density measurements of the body and head phantoms gave MAPE values of 4.6% and 1.0%, respectively. Zeff and electron density measurements significantly varied within the solid water background, showing a positional dependence within the phantom that dominated the total standard deviation in measurements. Zeff values dropped by 0.2 atomic units when the phantom was off‐center; electron density measurements were less affected by phantom position. Along the z‐axis, the accuracy drops off markedly at more than 50‐60 mm from the central slice.Conclusion: The Canon dual energy system offers an accurate way of measuring the Zeff and electron density of clinically relevant materials. Accuracy could be improved further by calibration to remove bias, careful attention to centering within the FOV, and avoiding measurements at the edges of the cone beam.


  • Open Access

    The helically-acquired CTDIvol as an alternative to traditional methodology

    by Stephanie M. Leon, Robert J. Kobistek, Edmond A. Olguin, Zhongwei Zhang, Izabella L. Barreto, Bryan C. Schwarz

    Purpose Most clinical computed tomography (CT) protocols use helical scanning; however, the traditional method for CTDIvol measurement replaces the helical protocol with an axial scan, which is not easily accomplished on many scanners and may lead to unmatched collimation settings and bowtie filters. This study assesses whether CTDIvol can be accurately measured with a helical scan and determines the impact of pitch, collimation width, and excess scan length. Methods CTDIvol was measured for 95 helical protocols on 31 CT scanners from all major manufacturers. CTDIvol was measured axially, then again helically, with the scan range set to the active area of the pencil chamber seen on the localizer image. CTDIvol measurements using each method were compared to each other and to the scanner-displayed CTDIvol. To test the impact of scan length, the study was repeated on four scanners, with the scan range set to the phantom borders seen on the localizer. Results It was not possible to match the collimation width between the axial and helical modes for 12 of the 95 protocols tested. For helical and axial protocols with matched collimation, the difference between the two methods averaged below 1 mGy with a correlation of R-2 = 0.99. The difference between the methods was not statistically significant (P = 0.81). The traditional method produced four measurements that differed from the displayed CTDIvol by >20%; no helical measurements did. The accuracy of the helical CTDIvol was independent of protocol pitch (R-2 = 0.0) or collimation (R-2 = 0.0). Extending the scan range to the phantom borders increased the measured CTDIvol by 2.1%-9.7%. Conclusion There was excellent agreement between the two measurement methods and to the displayed CTDIvol, without protocol or vendor dependence. The helical CTDIvol measurement can be accomplished more easily than the axial method on many scanners and is reasonable to use for QC purposes.


  • Open Access

    Assessment of volumetric absorbed dose for mobile fluoroscopic 3D image acquisition

    by Stephanie Leon

    Mobile fluoroscopy (c‐arm) units offering 3D image reconstruction are becoming more common in surgical settings. Although these images are “CT‐like” and sometimes replace the postoperative CT, the acquisition is technically very different from a traditional CT acquisition. Dose assessment is complicated by a large beam width, automatic exposure rate control, and a rotation of less than 360°. The purpose of this work was to explore the impact of these factors on the volumetric dose calculation and to provide practical recommendations for clinical physicists assessing dose from these units using commonly available equipment. CTDIW was calculated using the IAEA method for dosimetry of wide beams and compared to scans of the 32‐cm CTDI phantom using the full beam width and a 20‐mm collimated beam width. The impact of the partial rotation on the CTDIW calculation was assessed by acquiring measurements at four and twelve positions on the phantom periphery. For the system tested, the CTDIW was calculated to be 16.1 mGy using the IAEA method with default clinical protocol. Results showed that measuring CTDIW with the full beam width or a collimated beam width alone resulted in CTDI values of 19.0 mGy and 19.5 mGy, respectively. Using four peripheral measurements instead of 12 resulted in a difference of 4% for a collimated beam and 6% for an open beam. Variations in positioning on the order of a few centimeters resulted in a variation of only 4% with an open beam. The excellent reproducibility of the measurements using the full beam width suggests that this simple method is adequate for year‐to‐year comparisons. In contrast, the IAEA method is difficult to employ, particularly with 180° acquisitions. Use of peripheral measurements in excess of the usual four is time‐consuming and not necessary for most applications obtained with the geometry specific to this system.