HSHabib Samady

Habib Samady

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Habib Samady has a total of 517 co-authors. Here are the top co-authors by number of shared publications:

  • Parham Eshtehardi

    Division of Cardiology, Department of Medicine, Emory University School of Medicine, Atlanta, Georgia

    21 shared publications
  • Don P. Giddens

    The Wallace H. Coulter Department of Biomedical Engineering Georgia Institute of Technology and Emory University Atlanta Georgia USA

    14 shared publications
  • Olivia Y. Hung

    Andreas Gruentzig Cardiovascular Center, Division of Cardiology, Department of Medicine, Emory University School of Medicine, Atlanta, GA (J.-S.K., O.Y.H., P.E., R.R., M.R., S.K., S.G., H.H., N.S., G.M.B., C.L., P.K.M., A.A.Q., H.S.).

    14 shared publications
  • Bill D. Gogas

    The Andreas Gruentzig Cardiovascular Center, Division of Cardiology, Department of Medicine Emory University School of Medicine Atlanta GA USA

    13 shared publications
  • Alessandro Veneziani

    Department of Mathematics and Computer Science, Emory University, Atlanta, USA

    11 shared publications
  • Arnav Kumar

    Division of Cardiology, Department of Medicine, Emory University School of Medicine, Atlanta, USA

    11 shared publications

Latest Publications

  • Association of Low-Attenuation Noncalcified Plaque Shape and Degree of Intraplaque Embeddedness Using Atherosclerotic Imaging–enabled Quantitative CT with Acute Coronary Syndrome

    by Shant Malkasian, Nick S. Nurmohamed, Hyuk-Jae Chang, Andrew D. Choi, Hugo Marques, Sabee Molloi, Alexander van Rosendael, Benjamin J.W. Chow, Daniele Andreini, Edoardo Conte, et al.

    Adverse low-attenuation noncalcified plaque morphology using atherosclerotic imaging-enabled quantitative CT (ie, lobular, bean, or spherical low-attenuation noncalcified plaque shape or low-attenuation noncalcified plaque with ≥ 180° of embeddedness) was independently associated with acute coronary syndrome.


  • Open Access

    Invasive Evaluation of Coronary Artery Disease in Severe Aortic Stenosis—A Narrative Review

    by Harsh V. Thakkar, Habib Samady, Brian Ko, Adam J. Brown

    The coexistence of severe aortic stenosis (AS) and coronary artery disease (CAD) is common and presents important diagnostic and therapeutic challenges, particularly in patients being considered for transcatheter aortic valve replacement. Accurate assessment of coronary lesion significance in this setting is difficult because severe AS alters coronary haemodynamics, myocardial oxygen demand, microvascular function, and the balance between resting and hyperaemic flow. These changes may influence the interpretation of conventional physiological indices and complicate decisions regarding revascularisation. This narrative review summarises the pathophysiological interaction between severe AS and CAD and examines the contemporary evidence supporting invasive and non-invasive approaches to coronary assessment. We review the limitations and potential utility of fractional flow reserve, and non-hyperaemic pressure ratios, highlighting the frequent discordance observed between indices and the uncertainty regarding optimal thresholds in severe AS. Importantly, identification of physiologically significant lesions should be distinguished from evidence that revascularisation of these lesions improves clinical outcomes, as prospective outcome data remain limited. While recent trials support physiology-guided revascularisation in patients undergoing TAVR, outcome data remain linked primarily to conventional FFR thresholds rather than proposed AS-specific cutoffs. We also discuss emerging non-wire-based approaches, including quantitative flow ratio and computed tomography-derived fractional flow reserve, which may offer complementary value in selected patients. In addition, we examine the practical implications of coronary physiology for clinical decision-making before and after valve intervention, including the timing of percutaneous coronary intervention and the need to distinguish lesion-level diagnostic performance from evidence of clinical benefit. Current data suggest that no single modality is universally applicable and that assessment should be individualised according to lesion characteristics, clinical context, and procedural strategy. Proposed severe AS-specific thresholds for FFR and NHPR are derived from small predominantly observational studies, have not been prospectively validated against clinical outcomes and should be hypothesis-generating. A hybrid approach integrating angiographic, physiological, and computed tomography-based information may be most useful. Further prospective studies are needed to define optimal thresholds, validate management algorithms, and clarify whether physiology-guided strategies improve outcomes in severe AS.


  • Pericoronary Adipose Tissue Attenuation in Patients with Future Acute Coronary Syndromes: The ICONIC Study

    by Alan C. Kwan, Evangelos Tzolos, Eyal Klein, Donghee Han, Andrew Lin, Keiichiro Kuronuma, Billy Chen, Guadalupe Flores Tomasino, Heidi Gransar, Piotr J. Slomka, et al.

    Pericoronary adipose tissue attenuation, a marker of coronary inflammation, shows minimal quantitative differences between patients with and without future incident acute coronary syndromes in a matched case-control multicenter cohort of patients who underwent coronary CT angiography but is independently associated with future incident acute coronary syndromes in adjusted survival analyses.


  • Rapid Plaque Progression Is Independently Associated With Hyperglycemia and Low HDL Cholesterol in Patients With Stable Coronary Artery Disease: A PARADIGM Study

    by Danilo Neglia, Chiara Caselli, Erica Maffei, Filippo Cademartiri, Antonella Meloni, Eduardo Bossone, Luca Saba, Sang-Eun Lee, Ji Min Sung, Daniele Andreini, et al.

    BACKGROUND: We assessed whether combinations of cardiometabolic risk factors independently predict coronary plaque progression (PP) and major adverse cardiovascular events in patients with stable coronary artery disease. METHODS: Patients with known or suspected stable coronary artery disease (60.9±9.3 years, 55.4% male) undergoing serial coronary computed tomography angiographies (≥2 years apart), with clinical characterization and follow-up (N=1200), were analyzed from the PARADIGM study (Progression of Atherosclerotic Plaque Determined by Computed Tomographic Angiography Imaging). Plaque volumes measured in coronary segments (≥2 mm in diameter) were summed to provide whole heart plaque volume (mm 3 ) and percent atheroma volume (plaque volume/vessel volume×100; %) per patient at baseline and follow-up. Rapid PP was defined as a percent atheroma volume increase of ≥1.0%/y. Major adverse cardiovascular events included nonfatal myocardial infarction, death, and unplanned coronary revascularization. RESULTS: In an interscan period of 3.2 years (interquartile range, 1.9), rapid PP occurred in 341 patients (28%). At multivariable analysis, the combination of cardiometabolic risk factors defined as metabolic syndrome predicted rapid PP (odds ratio, 1.51 [95% CI, 1.12–2.03]; P =0.007) together with older age, smoking habits, and baseline percent atheroma volume. Among single cardiometabolic variables, high fasting plasma glucose (diabetes or fasting plasma glucose >100 mg/dL) and low HDL-C (high-density lipoprotein cholesterol; P 130/85 mm Hg) was an independent predictor of events (hazard ratio, 1.79 [95% CI, 1.10–2.90]; P =0.018) together with family history, baseline percent atheroma volume, and rapid PP. CONCLUSIONS: In patients with stable coronary artery disease, the combination of hyperglycemia with low HDL-C is associated with rapid PP independently of other risk factors, baseline plaque burden, and treatment. The combination of hyperglycemia with high systemic blood pressure independently predicts the worse outcome beyond PP. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02803411.


  • Open Access

    Clinical Outcomes Following Optical Coherence Tomographic versus Intravascular Ultrasound-Guided Percutaneous Coronary Intervention: A Meta-Analysis of Randomized Controlled Trials

    by Sheriff N. Dodoo, Sammudeen Ibrahim, Abdul-Fatawu Osman, Rayan Salih, Vikas Kilaru, Dennis Kwaku Ampadu, Afia S. Dodoo, Ugochukwu Egolum, Nima Ghasemzadeh, Ronnie Ramadan, et al.

    Background Optical coherence tomography (OCT) and intravascular ultrasound (IVUS) are adjunctive intracoronary imaging modalities used for optimizing the implantation of coronary stents. However, the impact of the choice of OCT versus IVUS on clinical outcomes and periprocedural complications is unclear. Objective To perform a meta-analysis of all vetted randomized controlled trials comparing OCT-guided versus IVUS-guided percutaneous coronary intervention. Methods We queried MEDLINE, Cochrane Library, Scopus, and clinicalTrials.gov databases from their commencement to February 2024 for all randomized controlled trials that compared OCT-guided versus IVUS-guided percutaneous coronary interventions. The primary endpoint was major adverse periprocedural events (MAPE), a composite of stent thrombosis (ST), distal embolization (DE), and distal edge dissection (DED). The secondary endpoints included stent thrombosis, distal embolization, distal edge dissection, Major-adverse-cardiac events (MACE)-[a composite of cardiac death, Target vessel myocardial infarction (TVMI), and target vessel revascularization (TVR)], all-cause mortality, cardiac death, TVMI, TVR, and nonfatal stroke. The odds ratio (OR) with a 95% confidence interval (CI) was analyzed using a random-effect model. Results Seven randomized controlled trials were included in the analysis, and 4446 patients were enrolled. OCT was associated with lower MAPE (OR: 0.65, CI:0.47-0.91, p= 0.01) compared to IVUS. ST, DE, and DED were similar between OCT and IVUS. There were no significant differences in MACE (OR: 0.86, CI:0.64-1.16, p= 0.32), all-cause mortality (OR: 0.83, CI:0.42-1.66, p= 0.60), Cardiac death (OR: 0.62, CI:0.20-1.89, p= 0.40), TVMI (OR: 0.69, CI:0.33-1.46, p= 0.33), TVR, (OR: 1.09, CI:0.70-1.71, p= 0.70), and non-fatal stroke (OR: 1.82, CI:0.67-4.95, p= 0.24) one year following the index procedure. Conclusion Optical coherence tomographic-guided PCI was associated with lower major adverse peri-procedural events (MAPE), including stent thrombosis, distal embolization, and distal edge dissection, compared to intravascular ultrasound-guided PCI. However, there was no difference in overall major adverse cardiac events, target vessel myocardial infarction, target vessel revascularization, and nonfatal stroke.

  • Open Access

    Optical Coherence Tomography–Based Functional Stenosis Assessment: FUSION—A Prospective Multicenter Trial

    by Allen Jeremias, Akiko Maehara, Mitsuaki Matsumura, Richard A. Shlofmitz, Aziz Maksoud, Takashi Akasaka, Hiram G. Bezerra, William F. Fearon, Habib Samady, Bruce Samuels, et al.

    BACKGROUND: Intravascular imaging and intracoronary physiology may both be used to guide and optimize percutaneous coronary intervention; however, they are rarely used together. The virtual flow reserve (VFR) is an optical coherence tomography (OCT)–based model of fractional flow reserve (FFR) facilitating the assessment of the physiological significance of coronary lesions. We aimed to validate the VFR assessment of intermediate coronary artery stenoses. METHODS: FUSION (Validation of OCT-Based Functional Diagnosis of Coronary Stenosis) was a multicenter, prospective, observational study comparing OCT-derived VFR to invasive FFR. VFR was mathematically derived from a lumped parameter flow model based on 3-dimensional lumen morphology. Patients undergoing coronary angiography with intermediate angiographic stenosis (40%–90%) requiring physiological assessment were enrolled. Investigational sites were blinded to the VFR analysis, and all OCT and FFR data were reviewed by an independent core laboratory. The coprimary end points were the sensitivity and specificity of VFR against FFR as the reference standard, each of which was tested against prespecified performance goals. RESULTS: After core laboratory review, 266 vessels in 224 patients from 25 US centers were included in the analysis. The mean angiographic diameter stenosis was 65.5%±14.9%, and the mean FFR was 0.83±0.11. Overall accuracy, sensitivity, and specificity of VFR versus FFR using a binary cutoff point of 0.80 were 82.0%, 80.4%, and 82.9%, respectively. The 97.5% lower confidence bound met the prespecified performance goal for sensitivity (71.6% versus 70%; P =0.01) and specificity (76.6% versus 75%; P =0.01). The area under the curve was 0.88 (95% CI, 0.84–0.92; P <0.0001). CONCLUSIONS: OCT-derived VFR demonstrates high sensitivity and specificity for predicting invasive FFR. Integrating high-resolution intravascular imaging with imaging-derived physiology may provide synergistic benefits as an adjunct to percutaneous coronary intervention. REGISTRATION: URL: https://clinicaltrials.gov ; Unique identifier: NCT04356027.


  • Open Access

    Differential predictability for high-risk plaque characteristics between fractional flow reserve and instantaneous wave-free ratio

    by Joo Myung Lee, Doosup Shin, Seung Hun Lee, Ki Hong Choi, Sung Mok Kim, Eun Ju Chun, Kwan Yong Lee, Doyeon Hwang, Sung Gyun Ahn, Adam J. Brown, et al.

    To evaluate the differential associations of high-risk plaque characteristics (HRPC) with resting or hyperemic physiologic indexes (instantaneous wave-free ratio [iFR] or fractional flow reserve [FFR]), a total of 214 vessels from 127 patients with stable angina or acute coronary syndrome who underwent coronary computed tomography angiography (CCTA) and invasive physiologic assessment were investigated. HPRC were classified into quantitative (minimal luminal area < 4 mm2 or plaque burden ≥ 70%) and qualitative features (low attenuation plaque, positive remodeling, napkin ring sign, or spotty calcification). Vessels with FFR ≤ 0.80 or iFR ≤ 0.89 had significantly higher proportions of HRPC than those with FFR > 0.80 or iFR > 0.89, respectively. FFR was independently associated with both quantitative and qualitative HRPC, but iFR was only associated with quantitative HRPC. Both FFR and iFR were significantly associated with the presence of ≥ 3 HRPC, and FFR demonstrated higher discrimination ability than iFR (AUC 0.703 vs. 0.648, P = 0.045), which was predominantly driven by greater discriminating ability of FFR for quantitative HRPC (AUC 0.832 vs. 0.744, P = 0.005). In conclusion, both FFR and iFR were significantly associated with CCTA-derived HRPC. Compared with iFR, however, FFR was independently associated with the presence of qualitative HRPC and showed a higher predictive ability for the presence of ≥ 3 HRPC.


  • Stent underexpansion is associated with high wall shear stress: a biomechanical analysis of the shear stent study

    by Sonali Kumar, David Molony, Sameer Khawaja, Kaylyn Crawford, Elizabeth W. Thompson, Olivia Hung, Imran Shah, Jessica Navas-Simbana, Arlen Ho, Arnav Kumar, et al.

    Coronary stent underexpansion is associated with restenosis and stent thrombosis. In clinical studies of atherosclerosis, high wall shear stress (WSS) has been associated with activation of prothrombotic pathways, upregulation of matrix metalloproteinases, and future myocardial infarction. We hypothesized that stent underexpansion is predictive of high WSS. WSS distribution was investigated in patients enrolled in the prospective randomized controlled study of angulated coronary arteries randomized to undergo percutaneous coronary intervention with R-ZES or X-EES. WSS was calculated from 3D reconstructions of arteries from intravascular ultrasound (IVUS) and angiography using computational fluid dynamics. A logistic regression model investigated the relationship between WSS and underexpansion and the relationship between underexpansion and stent platform. Mean age was 63±11, 78% were male, 35% had diabetes, mean pre-stent angulation was 36.7°±14.7°. Underexpansion was assessed in 83 patients (6,181 IVUS frames). Frames with stent underexpansion were significantly more likely to exhibit high WSS (> 2.5 Pa) compared to those without underexpansion with an OR of 2.197 (95% CI = [1.233–3.913], p = 0.008). There was no significant association between underexpansion and low WSS (< 1.0 Pa) and no significant differences in underexpansion between R-ZES and X-EES. In the Shear Stent randomized controlled study, underexpanded IVUS frames were more than twice as likely to be associated with high WSS than frames without underexpansion.


  • Open Access

    Combining IVUS + OCT Data, Biomechanical Models and Machine Learning Method for Accurate Coronary Plaque Morphology Quantification and Cap Thickness and Stress/Strain Index Predictions

    by Rui Lv, Liang Wang, Akiko Maehara, Mitsuaki Matsumura, Xiaoya Guo, Habib Samady, Don P. Giddens, Jie Zheng, Gary S. Mintz, Dalin Tang

    Assessment and prediction of vulnerable plaque progression and rupture risk are of utmost importance for diagnosis, management and treatment of cardiovascular diseases and possible prevention of acute cardiovascular events such as heart attack and stroke. However, accurate assessment of plaque vulnerability assessment and prediction of its future changes require accurate plaque cap thickness, tissue component and structure quantifications and mechanical stress/strain calculations. Multi-modality intravascular ultrasound (IVUS), optical coherence tomography (OCT) and angiography image data with follow-up were acquired from ten patients to obtain accurate and reliable plaque morphology for model construction. Three-dimensional thin-slice finite element models were constructed for 228 matched IVUS + OCT slices to obtain plaque stress/strain data for analysis. Quantitative plaque cap thickness and stress/strain indices were introduced as substitute quantitative plaque vulnerability indices (PVIs) and a machine learning method (random forest) was employed to predict PVI changes with actual patient IVUS + OCT follow-up data as the gold standard. Our prediction results showed that optimal prediction accuracies for changes in cap-PVI (C-PVI), mean cap stress PVI (meanS-PVI) and mean cap strain PVI (meanSn-PVI) were 90.3% (AUC = 0.877), 85.6% (AUC = 0.867) and 83.3% (AUC = 0.809), respectively. The improvements in prediction accuracy by the best combination predictor over the best single predictor were 6.6% for C-PVI, 10.0% for mean S-PVI and 8.0% for mean Sn-PVI. Our results demonstrated the potential using multi-modality IVUS + OCT image to accurately and efficiently predict plaque cap thickness and stress/strain index changes. Combining mechanical and morphological predictors may lead to better prediction accuracies.