XLXiaosheng Liu

Xiaosheng Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiaosheng Liu has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Research on S-Parameter Extraction and Equivalent Circuit Modeling of Multi-Port Busbars Based on Transmission Line Theory and Vector Fitting Method

    by Zijun Li, Yuting Han, Wenze Wang, Jinliang Ma, Xiaosheng Liu

    Multi-port busbars in renewable energy systems present significant challenges for power line communication (PLC) due to their complex high-frequency characteristics. This paper addresses the research gap by developing a comprehensive modeling approach integrating transmission line theory, electromagnetic simulation, and experimental verification. The methodology establishes a 3D model using CST Studio Suite for S-parameter extraction in the 200 kHz-12 MHz band. It also proposes a novel vector fitting method to derive an accurate π -type equivalent circuit. Experimental results demonstrate excellent agreement with simulations, with transmission coefficient deviations within 0.1 dB-0.8 dB. The proposed model provides reliable component-level characterization for PLC system optimization in smart grid applications.

  • Open Access

    Physical-Layer Secret Key Generation in Power Line Communication Networks

    by Jiarui Zhang, Xiaosheng Liu, Ying Cui, Dianguo Xu

    Due to the inherent broadcast nature, power line communication (PLC) is vulnerable to eavesdropping. Traditionally, the secret keys are generated/distributed by pre-shared keys, adaptive tone mapping, or asymmetric encryption algorithm. All of these methods face problems such as high computational complexity, high cost, or less security. To solve the problem, a physical layer security (PLS)-based secret key generation (SKG) scheme aiming at the typical in-home broadband PLC network is proposed in this paper. However, the slowly time-varying characteristic and the serious noise interference in PLC channels will degrade the performance of the PLS-based SKG scheme. To break through the limitation of the randomness of PLC channels, two-way random signals are introduced. To make the SKG system more resistant to noise, the channel frequency response-based adaptive quantization (CFR-AQ) algorithm is designed, in which the amplitude threshold and the quantization level are adaptive to the noise power and the target key disagreement rate (KDR) to maximize the key generation rate (KGR). The performance is analyzed in two scenarios: single eavesdropper and multiple eavesdroppers. The simulation results demonstrate that the proposed scheme has a good overall performance in terms of KDR, KGR, and security with a lower complexity in the presence of single or multiple non-collusive eavesdroppers, and it can be regarded as an alternative solution to generate secret keys in PLC networks.


  • Open Access

    GAN model using field fuzz mutation for in-vehicle CAN bus intrusion detection

    by Zhongwei Li, Wenqi Jiang, Xiaosheng Liu, Kai Tan, Xianji Jin, Ming Yang

    Controller area network (CAN) are widely used in smart vehicles to realize information interactions between electronic control units and other devices in vehicles. Owing to an increase in external communication interfaces, the cybersecurity of in-vehicle CAN bus networks is threatened. In-vehicle CAN intrusion detection systems with high detection rates and low false-negative rates have become important security protection measures for automotive networks. The boundary of the current machine learning-based in-vehicle CAN bus intrusion detection algorithm to determine the anomalous behavior triggered by CAN messages is unclear, and a validity check is required after the intrusion detection algorithm is designed. To solve the low coverage rate problem in the process of validating intrusion detection algorithms, an in-vehicle CAN fuzz-testing message generation model, the field-associative mutation generation adversarial network (FAMGAN), is proposed. To improve the defects of high randomness in generating messages in traditional fuzz-testing algorithms, FAMGAN adopts field division based on a conditional random field and the field association method based on the Apriori algorithm. Experiments were conducted on a real car using a code-built intrusion detection algorithm. The results demonstrate that FAMGAN can efficiently generate anomalous CAN messages and evaluate the performance of an in-vehicle CAN intrusion detection algorithm.


  • Simultaneous Wireless Power and Data Transfer: A Comprehensive Review

    by Yousu Yao, Pengfei Sun, Xiaosheng Liu, Yijie Wang, Dianguo Xu

    Simultaneous wireless power and data transfer (SWPDT) is widely investigated because of the increasing requirement for real-time communication between the primary and secondary sides in wireless power transfer systems. This article classifies SWPDT systems into four categories according to the type and number of data channels and data carrier generation method. They are power carrier-based SWPDT system, high-frequency data carrier-based SWPDT system, multiple inductive channels SWPDT system, and inductive–capacitive hybrid channels SWPDT system, respectively. Four key issues, including cross-talk minimization, improvement of signal-to-noise ratio, modulation method for high data rate and low bit error rate, and special design to achieve full-duplex communication and improve misalignment tolerance, are discussed. The advantages, disadvantages, and applications of the four types of SWPDT systems are summarized. Finally, conclusions and outlook of the SWPDT system are given.


  • A Novel Misalignment Tolerant Magnetic Coupler for Electric Vehicle Wireless Charging

    by Yousu Yao, Shenghan Gao, Jianwei Mai, Xiaosheng Liu, Xiangjun Zhang, Dianguo Xu

    The lateral misalignment for static electric vehicle (EV) wireless charging could be much larger than 100 mm if the parking assistance systems are unavailable. This article proposes a split flat solenoid coupler (SFSC) to significantly extend the lateral misalignment and reduce the copper and ferrite usage. To obtain a good balance among coupling, misalignment tolerance, and cost, an optimization method for SFSC is proposed where the size limitations and ferrite tile specifications are considered. The optimized SFSC is compared with two magnetic couplers recommended in SAE J2954 in terms of coupling coefficient and misalignment tolerance. To eliminate the impact of coil size and make the comparison fair, the quantified misalignment tolerance is introduced. The proposed SFSC provides much better misalignment tolerance than the recommended couplers. A 1000-W prototype is built to show the advantages of the proposed coupler. The output current keeps unchanged when the lateral misalignment is as high as 400 mm. A highest power transfer efficiency, from dc input to dc output, of 89.12% is achieved when the output power is 1000 W.


  • Open Access

    Vibration Suppression and Over-Quadrant Error Mitigation Methods for a Ball-Screw Driven Servo System With Dual-Position Feedback

    by Ming Yang, Qinan Ni, Xiaosheng Liu, Dianguo Xu

    For high-precision control in a ball-screw driven servo system, the full-closed loop position control structure with position measurements from both the drive side and the load side are usually required. However, compared with semi-closed loop position control, if only the load side position feedback is being used, then the inherent elastic link is included in the position loop, and the mechanical vibration will be easily induced. For this situation, the stability of the servo system will be affected. Moreover, in the ball-screw driven servo system, the backlash and friction in the mechanical transmission chain will introduce a typical contour error–over-quadrant error, which cannot be eliminated by adopting full-closed loop control. In order to maintain stability and high precision positioning performance, both vibration suppression and over-quadrant error mitigation methods are proposed in this paper. First, the model of full-closed loop position control system is established, on this basis, the reasons that why the full-closed loop control is more easily to induce the position vibration than the semi-closed loop control is analyzed. Then, a dual-position feedback control method, by introducing the drive side position information with a filter to the position loop feedback channel, is proposed, which combines the advantages of semi-closed loop control and full-closed loop, and features high gain margin and high control precision. Furthermore, based on the analysis of the mechanism of over-quadrant error, an adaptive backlash error compensation method which can reduce the over-quadrant error is proposed. Finally, simulation and experimental results in both single axis and dual axis are provided to demonstrate the feasibility and effectiveness of the proposed methods.


  • Design and Optimization of an Electric Vehicle Wireless Charging System Using Interleaved Boost Converter and Flat Solenoid Coupler

    by Yousu Yao, Shenghan Gao, Yijie Wang, Xiaosheng Liu, Xiangjun Zhang, Dian Guo Xu

    Simple but effective output voltage/current control schemes are essential for electric vehicle wireless charging systems (EVWCSs). This paper proposes an EVWCS using interleaved Boost converter (IBC) and flat solenoid coupler (FSC). The closed-loop control between the primary and secondary is realized by adjusting the duty cycle of the IBC. The currents and losses in the primary are reduced in the proposed system because the DC bus voltage in the primary is increased by using the IBC. The input current ripple is diminished owing to the interleaved structure. This paper also proposes a parameter optimization method to obtain the optimal FSC. Without loss of generality, the total area of the transmitter (Tx) and receiver (Rx) is assumed to be constant, and the Tx is assumed to be larger than the Rx. A scale-down prototype whose output power is 500 W was built in the laboratory to verify the theoretical analysis. The output voltage of the prototype kept constant when the misalignment was 200 mm in the winding direction or 100 mm in the magnetic direction. A highest system efficiency, from DC input to DC output, of 90.1% was achieved when the power transfer distance was 170 mm.


  • Real-time online optimal control of current-fed dual active bridges based on machine learning

    by Ming Han, Xiaosheng Liu, Honghong Pu, Liang Zhao, Kaixuan Wang, Dianguo Xu


  • A Networking Method for Power Line Communication Based on Stereo Mesh Network

    by Jiarui Zhang, Xiaosheng Liu, Pengfei Chen, Honghong Pu, Dianguo Xu

    In view of the deficiency of existing power line communication (PLC) networking algorithms, a novel networking method based on stereo mesh network is proposed. Consisting of the non-overlapping clustering network and the mesh network, the stereo mesh network is compatible with the redundancy of links and the lower complexity. On this basis the dynamic impact factor-α (DF-α) ant colony algorithm (ACA) combined with the improved genetic algorithm (GA) is used to search the optimal route. To dynamically meet the quality of service (QoS) requirements of PLC, an optimization object function is given. The simulation results show that by the algorithm, routes of PLC networks can be dynamically optimized to guarantee the QoS with more reliable performance and less network overhead.