Kirsten J. Dehning
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kirsten J. Dehning has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Stefan Zimmermann
Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover
4 shared publications - Moritz Hitzemann
Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany
3 shared publications M. Hitzemann
Institute of Electrical Engineering and Measurement Technology Department of Sensors and Measurement Technology Leibniz University Hannover Appelstr. 9A 30167 Hannover Germany
2 shared publicationsS. Zimmermann
Institute of Electrical Engineering and Measurement Technology Department of Sensors and Measurement Technology Leibniz University Hannover Appelstr. 9A 30167 Hannover Germany
2 shared publications- Sven Fisahn
Bundeswehr Research Institute for Protective Technologies and CBRN Protection, Munster, Germany
2 shared publications A. Gossmann
Institute of Electrical Engineering and Measurement Technology Department of Sensors and Measurement Technology Leibniz University Hannover Appelstr. 9A 30167 Hannover Germany
1 shared publication
Latest Publications
- Open Access
- 7 June 2024
- Published by MDPI AG in Electronics
- Vol. 13 (12) , 2247
Continuous Recording of Resonator Characteristics Using Single-Sideband Modulation
Electrical resonators are usually characterized by their resonance frequency, attenuation and quality factor. External quantities can affect these parameters, resulting in a characteristic change in the resonator, which can be used as a sensor effect. This work presents a new concept and electronic device for the continuous recording of resonator characteristics using single-sideband modulation. A test signal consisting of a center frequency and two sidebands is generated and the center frequency is set close to the resonator’s resonance frequency while the two sidebands are adjusted symmetrically around the center frequency. By exiting the resonator with the test signal and demodulating the resulting output into individual frequency components, a continuous measurement of the attenuation is possible. The center frequency is adjusted so that both sidebands have equal attenuation, resulting in a center frequency that corresponds to the resonance frequency of the resonator. If the resonator does not show a symmetrical frequency response, the sideband attenuation ratio can be adjusted accordingly. Continuous recording of the resonator characteristics at a sampling rate of 100 Sps was verified using a digitally tunable RLC series resonator with resonance frequencies between 250 MHz and 450 MHz, resulting in a maximum error below 1.5%.
- 7 June 2024
- Published by MDPI AG in Electronics
- Vol. 13 (12) , 2247
Open AccessContinuous Recording of Resonator Characteristics Using Single-Sideband Modulation
Electrical resonators are usually characterized by their resonance frequency, attenuation and quality factor. External quantities can affect these parameters, resulting in a characteristic change in the resonator, which can be used as a sensor effect. This work presents a new concept and electronic device for the continuous recording of resonator characteristics using single-sideband modulation. A test signal consisting of a center frequency and two sidebands is generated and the center frequency is set close to the resonator’s resonance frequency while the two sidebands are adjusted symmetrically around the center frequency. By exiting the resonator with the test signal and demodulating the resulting output into individual frequency components, a continuous measurement of the attenuation is possible. The center frequency is adjusted so that both sidebands have equal attenuation, resulting in a center frequency that corresponds to the resonance frequency of the resonator. If the resonator does not show a symmetrical frequency response, the sideband attenuation ratio can be adjusted accordingly. Continuous recording of the resonator characteristics at a sampling rate of 100 Sps was verified using a digitally tunable RLC series resonator with resonance frequencies between 250 MHz and 450 MHz, resulting in a maximum error below 1.5%.
- Open Access
Split-Ring Resonator Based Sensor for the Detection of Amino Acids in Liquids
Amino acids belong to the most important compounds for life. They are structural components of proteins and required for growth and maintenance of cells. Essential amino acids cannot be produced by the organism and must be ingested through the nutrition. Therefore, the detection of amino acids is of great interest when analyzing cell culture media and nutrition. In this work, we present a split-ring resonator as a simple but sensitive detector for amino acids. Split-ring resonators are RLC resonant circuits with a split capacitance and thus a resonance frequency that depends on the electromagnetic properties of a liquid sample at the split capacitance. Here, the split capacitance is an interdigital structure for highest sensitivity and covered with a fluidic channel for flow through experiments. First measurements with a vector network analyzer show detection limits in the range from 105 µM for glutamic acid to 1564 µM for isoleucine, depending on the electromagnetic properties of the tested amino acids. With an envelope detector for continuous recording of the resonance frequency, the split-ring resonator can be used in ion chromatography. At a flow rate of 0.5 mL/min, it reaches limits of detection of 485 µM for aspartic acid and 956 µM for lysine.
Open AccessSplit-Ring Resonator Based Sensor for the Detection of Amino Acids in Liquids
Amino acids belong to the most important compounds for life. They are structural components of proteins and required for growth and maintenance of cells. Essential amino acids cannot be produced by the organism and must be ingested through the nutrition. Therefore, the detection of amino acids is of great interest when analyzing cell culture media and nutrition. In this work, we present a split-ring resonator as a simple but sensitive detector for amino acids. Split-ring resonators are RLC resonant circuits with a split capacitance and thus a resonance frequency that depends on the electromagnetic properties of a liquid sample at the split capacitance. Here, the split capacitance is an interdigital structure for highest sensitivity and covered with a fluidic channel for flow through experiments. First measurements with a vector network analyzer show detection limits in the range from 105 µM for glutamic acid to 1564 µM for isoleucine, depending on the electromagnetic properties of the tested amino acids. With an envelope detector for continuous recording of the resonance frequency, the split-ring resonator can be used in ion chromatography. At a flow rate of 0.5 mL/min, it reaches limits of detection of 485 µM for aspartic acid and 956 µM for lysine.
- Open Access
- 4 April 2022
- Published by MDPI AG in Electronics
- Vol. 11 (7) , 1139
Fast Readout of Split-Ring Resonators Made Simple and Low-Cost for Application in HPLC
Split-ring resonators (SRR) are simple electrical circuits that show a significant shift in resonance frequency even with the smallest changes in split capacitance, and thus in permittivity, electric conductivity, and dielectric losses of the split capacitor’s dielectric. Usually, the resonance frequency is derived from the frequency response, but recording the frequency spectrum takes a certain amount of time. Here, we present a new capillary split-ring resonator CaSRR with fast readout for liquid chromatography (LC), which is capable of accurately detecting very fast changes in split capacity. The proposed method is based on the detection of the transmitted signal at a single frequency that is analyzed by demodulation. The demodulated signal changes its amplitude depending on the shift of the resonance frequency. Our simple low-cost electronics enables an average sampling rate of 42 Hz with 128 averages of the demodulated signal and has a frequency stability of 840 mHz. Thus, a minimum change in permittivity of Δεr,min = 11.26 × 10−3 can be detected. Finally, a chromatogram of one sugar (glucose) and one sugar alcohol (xylitol) is recorded using the SRR and is compared to a standard refractive index detector.
- 4 April 2022
- Published by MDPI AG in Electronics
- Vol. 11 (7) , 1139
Open AccessFast Readout of Split-Ring Resonators Made Simple and Low-Cost for Application in HPLC
Split-ring resonators (SRR) are simple electrical circuits that show a significant shift in resonance frequency even with the smallest changes in split capacitance, and thus in permittivity, electric conductivity, and dielectric losses of the split capacitor’s dielectric. Usually, the resonance frequency is derived from the frequency response, but recording the frequency spectrum takes a certain amount of time. Here, we present a new capillary split-ring resonator CaSRR with fast readout for liquid chromatography (LC), which is capable of accurately detecting very fast changes in split capacity. The proposed method is based on the detection of the transmitted signal at a single frequency that is analyzed by demodulation. The demodulated signal changes its amplitude depending on the shift of the resonance frequency. Our simple low-cost electronics enables an average sampling rate of 42 Hz with 128 averages of the demodulated signal and has a frequency stability of 840 mHz. Thus, a minimum change in permittivity of Δεr,min = 11.26 × 10−3 can be detected. Finally, a chromatogram of one sugar (glucose) and one sugar alcohol (xylitol) is recorded using the SRR and is compared to a standard refractive index detector.
- Open Access
- 1 January 2022
- Published by AMA Service GmbH
- p. 132-135
P20 - Split-Ring Resonator for measuring low amounts of glutamic acid in pure water
- 1 January 2022
- Published by AMA Service GmbH
- p. 132-135
Open AccessP20 - Split-Ring Resonator for measuring low amounts of glutamic acid in pure water
- Open Access
- 10 December 2020
- Published by Copernicus GmbH in Advances in Radio Science
- Vol. 18 (K.) , 89-95
Respiration parameter determination with non-obstructive methods
Measuring respiratory parameters like the breathing frequency or the tidal volume is essential in intensive care to ensure an optimal and lung protecting ventilation. A common practice in artificial ventilation of sensitive patients like infants or neonates is the use of uncuffed endotracheal tubes in combination with continuous positive airway pressure (CPAP). This comes with the disadvantage of an unknown leakage making it difficult to detect spontaneous breathing or to measure the tidal volume reliable. A novel non-obstructive method to determine respiratory parameters as well as dynamic changes of thoracic parameters has recently been presented and uses a pair of coupled UHF (ultra high frequency) antennae. In this paper, a respective setup is investigated numerically using finite difference time domain method and experimentally using an artificial lung phantom. Both approaches show that the investigated method seems capable of allowing a contactless triggering to synchronize natural and artificial breathing. The results are compared to derive a better understanding of influencing factors and opportunities for an optimisation.
- 10 December 2020
- Published by Copernicus GmbH in Advances in Radio Science
- Vol. 18 (K.) , 89-95
Open AccessRespiration parameter determination with non-obstructive methods
Measuring respiratory parameters like the breathing frequency or the tidal volume is essential in intensive care to ensure an optimal and lung protecting ventilation. A common practice in artificial ventilation of sensitive patients like infants or neonates is the use of uncuffed endotracheal tubes in combination with continuous positive airway pressure (CPAP). This comes with the disadvantage of an unknown leakage making it difficult to detect spontaneous breathing or to measure the tidal volume reliable. A novel non-obstructive method to determine respiratory parameters as well as dynamic changes of thoracic parameters has recently been presented and uses a pair of coupled UHF (ultra high frequency) antennae. In this paper, a respective setup is investigated numerically using finite difference time domain method and experimentally using an artificial lung phantom. Both approaches show that the investigated method seems capable of allowing a contactless triggering to synchronize natural and artificial breathing. The results are compared to derive a better understanding of influencing factors and opportunities for an optimisation.
- 1 January 2019
- Published by AMA Service GmbH
- p. 167-171
P2.02 - Split-ring resonator: A new detector in liquid chromatography
- 1 January 2019
- Published by AMA Service GmbH
- p. 167-171
P2.02 - Split-ring resonator: A new detector in liquid chromatography