Respiration parameter determination with non-obstructive methods
Open Access
- 10 December 2020
- journal article
- research article
- Published by Copernicus GmbH in Advances in Radio Science
- Vol. 18 (K.) , 89-95
Abstract
Measuring respiratory parameters like the breathing frequency or the tidal volume is essential in intensive care to ensure an optimal and lung protecting ventilation. A common practice in artificial ventilation of sensitive patients like infants or neonates is the use of uncuffed endotracheal tubes in combination with continuous positive airway pressure (CPAP). This comes with the disadvantage of an unknown leakage making it difficult to detect spontaneous breathing or to measure the tidal volume reliable. A novel non-obstructive method to determine respiratory parameters as well as dynamic changes of thoracic parameters has recently been presented and uses a pair of coupled UHF (ultra high frequency) antennae. In this paper, a respective setup is investigated numerically using finite difference time domain method and experimentally using an artificial lung phantom. Both approaches show that the investigated method seems capable of allowing a contactless triggering to synchronize natural and artificial breathing. The results are compared to derive a better understanding of influencing factors and opportunities for an optimisation.Keywords
This publication has 13 references indexed in Scilit:
- A novel non-invasive, non-conductive method for measuring respirationJournal of Sensors and Sensor Systems, 2020
- Unobtrusive Vital Sign Monitoring in Automotive Environments—A ReviewSensors, 2018
- IEEE Standard Definitions of Terms for Antennas2015
- Effect of endotracheal tube leakage on respiratory function monitoring: Comparison of three neonatal ventilatorsJournal of Pediatric Intensive Care, 2015
- Noncontact Monitoring of Cardiorespiratory Activity by Electromagnetic CouplingIEEE Transactions on Biomedical Engineering, 2013
- A Wearable Capacitive Sensor for Monitoring Human Respiratory RateJapanese Journal of Applied Physics, 2013
- Non-contact heartbeat and respiration detector using capacitive sensor with Colpitts oscillatorElectronics Letters, 2008
- On radiating-zone boundaries of short, λ2, and λ dipolesIEEE Antennas and Propagation Magazine, 2004
- Taschenbuch der Hochfrequenztechnik1992
- The Impedance Concept and Its Application to Problems of Reflection, Refraction, Shielding and Power AbsorptionBell System Technical Journal, 1938