MPMilena Pisano

Milena Pisano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Milena Pisano has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Role of Digital Workflow in Creating a New, Esthetic and Functional Smile in a Periodontally Compromised Patient: A Case Report

    by Carlotta Cacciò, Marco Tallarico, Aurea Immacolata Lumbau, Francesco Mattia Ceruso, Milena Pisano

    Background and Clinical Significance: Prosthetic rehabilitation in the aesthetic zone of periodontally compromised patients presents a complex clinical challenge, requiring a careful coordination of aesthetic, functional, and biological demands. This case highlights the benefits of digital dentistry, interdisciplinary collaboration, and regular maintenance in achieving long-term success in complex rehabilitations of periodontally compromised patients. Case Presentation: This case report describes the digital minimally invasive rehabilitation of a 39-year-old male patient with Stage III periodontitis, occlusal discrepancies, tooth mobility, and an interincisal diastema. A fully digital workflow—including intraoral scanning, aesthetic previewing, and mandibular motion analysis—was employed to guide diagnosis, treatment planning, and prosthetic execution. Conservative tooth preparations using a biologically oriented approach (BOPT) were combined with customised provisional restorations to support soft tissue conditioning and functional control throughout the provisional phases. Mandibular motion tracking facilitated the design of a personalised anterior guidance to improve occlusion and correct the deep bite. The interincisal diastema was initially maintained then closed during the advanced phase of treatment based on aesthetic simulations and patient preference. One unplanned endodontic treatment was required during the provisional phase, but no other complications occurred. Conclusions: At the four-year follow-up, the patient demonstrated stable periodontal and occlusal conditions, improved clinical indices, and high satisfaction with the aesthetic outcome.


  • Open Access

    A Quality Study on Patients’ Perceptions After Digitally Driven Smile Creation Including Aligners and Minimally Invasive Prosthetic Restorations

    by Marco Tallarico, Aurea Immacolata Lumbau, Mariapia Sorrenti, Roberta Lione, Carlotta Cacciò, Marco Annucci, Silvio Mario Meloni, Milena Pisano

    Background: Aesthetic dentistry increasingly demands minimally invasive, predictable, and patient-centered solutions. Digital technologies and AI-driven planning tools are now integral to interdisciplinary treatments. Aim: To evaluate, by means of a 16-item questionnaire, patients’ perceptions of smile aesthetics and oral function before and after receiving clear aligner therapy followed by minimally invasive ceramic veneers, using digital planning and Smile Creator software. Materials and Methods: Five adult patients underwent digital smile design, clear aligner therapy, and feldspathic veneer placement. Pre- and post-treatment perceptions of smile aesthetics and function were assessed using a structured questionnaire. AI-based simulation tools (2D and 4 K TruSmile video previews) were incorporated. Paired t-tests were used to compare outcomes before and after treatment. Results: Mean pre-treatment scores were 4.8 for smile aesthetics and 6.6 for function. Post-treatment scores significantly improved to 9.8 (p = 0.001) and 9.4 (p = 0.002), respectively. Patients rated AI-generated smile previews more favorably than 2D designs and acknowledged the value of digital tools in understanding and accepting treatment. Conclusions: The integration of digital and AI-based tools in aesthetic dentistry enhances patient communication, improves predictability, and enables minimally invasive treatment. Patient satisfaction was high, underscoring the effectiveness of the combined orthodontic and prosthetic approach.


  • Open Access

    A Quality Study on Patients’ Perception of Aesthetics and Function After Digitally Driven Smile Creation with a Combined Approach Including Aligners and Minimally Invasive Prosthetic Restorations

    by Marco Tallarico, Aurea Maria Immacolata Lumbau, Mariapia Sorrenti, Roberta Lione, Carlotta Cacciò, Marco Annucci, Silvio Mario Meloni, Milena Pisano

    Background: Aesthetic dentistry increasingly demands minimally invasive, predictable, and patient-centered solutions. Digital technologies and AI-driven planning tools are now integral to interdisciplinary treatments. Aim: To evaluate patients’ perception of smile aesthetics and oral function before and after receiving clear aligner therapy followed by minimally invasive ceramic veneers, using digital planning and pre-visualization tools. Materials and Methods: five adult patients underwent digital smile design, clear aligner therapy, and feldspathic veneer placement. Pre- and post-treatment perception of smile aesthetics and function were assessed using a structured questionnaire. AI-based simulation tools (2D and 4K TruSmile video previews) were incorporated. Paired t-tests were used to compare outcomes before and after treatment. Results: Mean pre-treatment scores were 4.8 for smile aesthetics and 6.6 for function. Post-treatment scores significantly improved to 9.8 (p = 0.001) and 9.4 (p = 0.002), respectively. Patients rated AI-generated smile previews more favorably than 2D designs and acknowledged the value of digital tools in understanding and accepting treatment. Conclusions : The integration of digital and AI-based tools in aesthetic dentistry enhances patient communication, improves predictability, and enables minimally invasive treatment. Patient satisfaction was high, underscoring the effectiveness of the combined orthodontic and prosthetic approach.

  • Open Access

    Create a New Smile with a Functional and Esthetic Digital Workflow

    by Carlotta Cacciò, Marco Tallarico, Aurea Maria Immacolata Lumbau, Francesco Mattia Ceruso, Milena Pisano

    Prosthetic rehabilitation in the aesthetic zone of periodontally compromised patients presents a complex clinical challenge, requiring careful coordination of aesthetic, functional, and biological demands. This case report describes the digital, minimally invasive rehabilitation of a 39-year-old male patient with Stage III periodontitis, occlusal discrepancies, tooth mobility, and an interincisal diastema. A fully digital workflow—including intraoral scanning, aesthetic previewing, and mandibular motion analysis—was employed to guide diagnosis, treatment planning, and prosthetic execution. Conservative tooth preparations using a biologically oriented approach (BOPT) were combined with customized provisional restorations to support soft tissue conditioning and functional control throughout the provisional phases. Mandibular motion tracking facilitated the design of a personalized anterior guidance to improve occlusion and correct the deep bite. The interincisal diastema was initially maintained, then closed during the advanced phase of treatment based on aesthetic simulations and patient preference. One unplanned endodontic treatment was required during the provisional phase, but no other complications occurred. At the four-year follow-up, the patient demonstrated stable periodontal and occlusal conditions, improved clinical indices, and high satisfaction with the aesthetic outcome. This case highlights the benefits of digital dentistry, interdisciplinary collaboration, and regular maintenance in achieving long-term success in complex rehabilitations of periodontally compromised patients.

  • Open Access

    The Use of Vacuum Plasma Surface Treatment to Improve Bone Healing and Regeneration in Socket Preservation and GBR: A Case Series with Histological Analysis

    by Marco Tallarico, Michele Troia, Milena Pisano, Silvio Mario Meloni, Dario Melodia, Claudia Della Via, Dolaji Henin, Francesco Mattia Ceruso, Carlotta Cacciò, Aurea Immacolata Lumbau

    Purpose: To evaluate the clinical and histological outcomes of patients that receive implant-supported crowns after vacuum plasma surface treatment (VPST) of biomaterials used in socket preservation (SP) and guided bone regeneration (GBR). Materials and methods: This study was designed as a case series. Patients in need of tooth extraction and socket preservation or guided bone regeneration were enrolled. The socket preservation technique was performed after tooth extraction using a heterologous collagen bone graft and a collagen xenomatrix, both activated with vacuum plasma. Meanwhile, a two-stage horizontal ridge augmentation was performed using a customized titanium mesh and a mix of autologous (untreated) and heterologous (treated) bone grafts, along with a treated collagen membrane. ACTILINK Reborn with Universal Vortex Holder (Plasmapp Co., Ltd., Daejeon, Republic of Korea) was used to treat all biomaterials. The outcome measures were implant and prosthesis failures, complications, and histological examination. Soft and hard tissue samples were collected at the time of implant placement only in patients treated with SP. Results: A total of six patients were treated—three with socket preservation and delayed implant placement, and three with staged GBR. No implant or prosthesis failed. One customized titanium mesh broke after plasma treatment, requiring replacement with a pericardium membrane. No other complications occurred. Histological analysis at three months post-surgery revealed well-vascularized newly formed bone at different stages of maturation with integrated bone graft particles, while the soft tissue appeared to be physiologically structured. Conclusion: VPST may enhance the hydrophilicity of biomaterials, supporting favorable healing outcomes in SP and GBR. Further randomized controlled trials with appropriate sample size calculations are needed to confirm these preliminary results.


  • Open Access

    Crestal Hydraulic Sinus Lift with Simultaneous Implant Insertion: A Retrospective Case Series

    by Francesco Mattia Ceruso, Aurea Immacolata Lumbau, Francesco Pernice, Alessandro Mastroianni, Michele Miranda, Silvio Mario Meloni, Marco Gargari, Marco Tallarico, Milena Pisano

    Objectives: This retrospective study aimed to evaluate the increase in vertical bone height following sinus lift procedures using the CAS (Crestal Approach Sinus) kit technique in combination with tissue-level implants. Additionally, the quantity of bone between the implant apex and the Schneiderian membrane was assessed to determine the effectiveness and safety of this minimally invasive approach. Methods: The study included 15 patients (20 implants) who underwent sinus lift procedures with the CAS kit technique and tissue-level implants in the posterior maxilla between September 2021 and October 2024. Inclusion criteria required a minimum residual bone height (RBH) of 2 mm. Cone-beam computed tomography (CBCT) scans were used for initial screening, and panoramic radiography evaluated outcomes at implant placement and nine months postoperatively. Primary outcomes included implant and prosthetic survival rates, as well as biological and technical complications. Secondary outcomes were vertical bone height and the amount of bone above the implant tip. Statistical analyses were conducted using the Wilcoxon signed-rank test with a significance level of 0.05. Results: All implants achieved successful osseointegration, with no implant or prosthetic failures and no biological or technical complications reported. The mean RBH at implant placement was 4.2 ± 1.4 mm, which increased to an overall membrane elevation of 13.8 ± 1.8 mm. At the 9-month follow-up, the overall membrane elevation was slightly reduced to 13.0 ± 1.6 mm (p = 0.000), with a mean bone gain of 9.6 ± 2.4 mm. The amount of bone above the implant tip was 3.4 ± 1.7 mm at placement, decreasing to 3.0 ± 1.2 mm at follow-up (p = 0.007). Conclusions: The CAS kit technique combined with tissue-level implants demonstrated significant vertical bone gain and high implant survival rates without complications. This minimally invasive approach proved effective and safe for sinus augmentation in patients with limited residual bone height. The findings support the CAS kit’s potential as a preferred technique for maxillary sinus elevation. Further research with larger cohorts and long-term follow-up is needed to validate these results.


  • Open Access

    Histological Analysis of Biological Width and Collagen Fibers Orientation Around Screw-Less, Morse Taper, Hemispherical Base Abutments 8 and 16 Weeks After Implant Uncovering: An Observational Clinical Trial

    by Fabrizio Zaccheo, Giulia Petroni, Marco Tallarico, Cherana Gioga, Raffaella Carletti, Cira Rosaria Tiziana Di Gioia, Vincenzo Petrozza, Silvio Mario Meloni, Dario Melodia, Milena Pisano, et al.

    Objectives: This study aimed to histologically evaluate, in humans, the orientation of collagen fibers around screw-less, Morse taper, hemispherical base abutments. Methods: This study was designed as an observational, case–control, clinical trial to evaluate the histological orientation of collagen fibers around implants. Biopsies of the peri-implant tissue were performed 8 (group A, control) or 16 (group B, test) weeks of implant uncovering, and histologically analyzed under optical microscope using Hematoxylin and Eosin, Masson, and Picro Sirius histochemical staining and a scanning electron microscope. Results: Eight patients were enrolled in this study and 16 biopsies were performed. All the biopsies were correctly analyzed. The histological examination of cross-sectional portions of the tissue taken 8 weeks after implant uncovering showed the almost complete absence of epithelial lining, while the connective tissue bundles in the superficial portion showed a lower circular pattern. The histochemical cross-section examination of the tissue taken 16 weeks after implant uncovering showed the partial presence of non-keratinizing epithelial lining at the implant site and the collagen bundles showed a greater organization, with a circumferential course around the abutment. At 8 weeks, the final histological analysis showed an average height of 1.01 mm for the keratinized epithelium, 0.83 mm for the non-keratinized epithelium, and 1.39 mm for the connective tissue. While, at 16 weeks, the values were 1.20 mm, 0.48 mm, and 1.11 mm, respectively. No statistically significant differences were found between the groups (p > 0.05). Conclusions: Histologically, there were not any differences in the height and profile of the gingiva between 8 and 16 weeks of healing after prosthesis delivery. Greater organization of the collagen fibers with a circumferential course around the abutment was found in the test group (16 weeks) compared with the control group (8 weeks).


  • Open Access

    Accuracy and Precision of Digital Impression with Reverse Scan Body Prototypes and All-on-4 Protocol: An In Vitro Research

    by Marco Tallarico, Mohammad Qaddomi, Elena De Rosa, Carlotta Cacciò, Yeo Jin Jung, Silvio Mario Meloni, Francesco Mattia Ceruso, Aurea Immacolata Lumbau, Milena Pisano

    Background/Objectives: Digital workflows for implant-supported full-arch restorations remain challenging. This study evaluated the accuracy and precision of digital impressions using reverse scan body (RSB) prototypes and intraoral scanners (IOSs) for rehabilitating fully edentulous patients following the All-on-4 protocol. Secondary objectives included comparing accuracy between expert clinicians and beginners, as well as desktop scanners and various RSB designs. Methods: An in vitro study was conducted using a fully edentulous mandible model with four Osstem TSIII implants. A final-year dental student and an expert clinician captured digital impressions using IOSs and desktop scanners. Four groups were analyzed: (A) original scan bodies with the IOS, (B) short RSBs with the IOS, (C) RSBs with desktop scanners (short sandblasted, long sandblasted, long coated), and (D) a control group using original scan bodies with a desktop scanner. Root mean square (RMS) values measured dimensional differences, with statistical analysis performed using the Wilcoxon signed-rank test and one-way ANOVA (α = 0.05). Results: A total of 42 scans were analyzed. No significant difference was found between expert and student for original scan bodies using the IOS (p = 0.220), while RSB prototypes showed significant differences (p = 0.008). No significant accuracy differences were noted between original scan bodies and RSBs with the IOS, but IOSs outperformed desktop scanners. Among RSBs scanned with desktop scanners, no significant differences were observed between designs. Conclusions: RSB prototypes are a viable alternative to original scan bodies for fully digital workflows in All-on-4 rehabilitations, with IOSs offering superior accuracy. However, proper training is crucial for optimizing RSB accuracy. Variations in height and coating did not impact overall accuracy.


  • Open Access

    The Use of Vacuum Plasma Surface Treatment to Improve the Hydrophilicity and Wettability of Bone Graft Substitutes and Resorbable Membranes: An In Vitro Study

    by Marco Tallarico, Silvio Mario Meloni, Michele Troia, Carlotta Cacciò, Aurea Immacolata Lumbau, Ieva Gendviliene, Francesco Mattia Ceruso, Milena Pisano

    Background/Objectives: We wished to evaluate in vitro whether vacuum plasma surface treatment of bone graft substitutes and resorbable membranes could improve the hydrophilicity and wettability of the tested materials. Methods: A total of 28 sterilized samples were considered for this research and divided into three groups. Six samples were used for the SEM-EDS analysis. The other 22 samples were randomly assigned into the test (plasma-treated, n = 11) and control (no treatment, n = 11) groups. Vacuum plasma surface treatment was performed in the test group before the SEM-EDS analysis using the ACTILINK reborn with a material holder (Plasmapp Co., Ltd., Daejeon, Republic of Korea). Plasmatreat (Plasmatreat, Steinhagen, Germany) inks were used to evaluate the differences in the hydrophilicity between the test and control groups. The outcome measures were the absorption time, wettability grade, and grade of decontamination after different time cycles. Results: After the vacuum plasma surface treatment, the absorption time of the inks statistically decreased in all of the subgroups (p < 0.05), while the wettability grade increased. The SEM-EDS analyses showed an increased reduction rate of carbon impurities after up to three vacuum plasma surface treatment cycles. Furthermore, the SEM-EDS analysis did not reveal any areas of damage caused by the multiple treatments. Conclusions: Within the limitations of this in vitro study, the vacuum plasma surface treatment increased the hydrophilicity and wettability of the tested biomaterials. Particle bone graft and bone blocks should be treated using longer time programs. Further well-conducted randomized clinical trials with sample size calculations are needed to confirm these preliminary results.


  • Open Access

    Mechanical Behaviors of a New Polymer-Based Restorative Material for Immediate Loading: An In Vitro Comparative Study

    by Milena Pisano, Łukasz Zadrożny, Anna Di Marzio, Ignazio Kurti, Silvio Mario Meloni, Aurea Immacolata Lumbau, Francesco Mollica, Mario Cesare Pozzan, Santo Catapano, Rafał Maksymilian Molak, et al.

    The aim of the present in vitro comparative study is to validate a novel composite polymer, named “ONLY”, developed to overcome the mechanical drawbacks of conventional, metal-reinforced poly(methyl methacrylate) (PMMA) interim restoration. Ten interim restorations were designed and fabricated (five in the composite “ONLY” group, and five in the metal-reinforced PMMA group). All the samples were screwed into the prototype models, simulating a complete edentulous mandible rehabilitated with six straight implants. Outcome measures were break point (load, N) and displacement (mm) through a static compression test, and material behavior through a dynamic cyclic test method (fatigue test). A total of 20 samples were tested (10 for static and 10 for dynamic). In each group, five samples (test and control) were used. All the specimens completed the mechanical tests, as planned. There was no statistically significant difference between groups for any test. In the test group, the break point was 1953.19 ± 543.73 N, while it was 2031.10 ± 716.68 N in the control group (p = 0.775). The displacement was 1.89 ± 0.34 mm in the test group and 1.98 ± 0.75 mm in the control group (p = 0.763). Using the dynamic cyclic test method, in the control group the mean load was 2504.60 ± 972.15 N, while in the test group the mean load was 3382.00 ± 578.50 N. The difference between groups was 877.40 ± 579.30 N (p value = 0.121). Within the limitations of this in vitro study, the novel composite polymer can be used to immediately load dental implants. Further clinical research is needed to confirm these preliminary results.