CCCarlotta Cacciò

Carlotta Cacciò

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Carlotta Cacciò has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Clinical Outcomes at 2 Years and Early Radiographic Changes Following Transcrestal Sinus Floor Elevation in Sites with Residual Bone Height Below or Above 4 mm: A Retrospective Comparative Cohort Study

    by Francesco Mattia Ceruso, Francesco Pernice, Marco Gargari, Carola Di Frischia, Alessandro Mastroianni, Carlotta Cacció, Marco Tallarico, Fabrizio Zaccheo, Erta Xhanari

    Background/Objectives: Maxillary sinus floor elevation is a well-established procedure for enabling implant placement in the posterior maxilla when residual bone height is insufficient. Minimally invasive transcrestal techniques, including the use of the Crestal Approach Sinus (CAS) kit, have been developed to reduce surgical morbidity while maintaining predictable clinical outcomes. The aim of this retrospective comparative study was to evaluate the clinical and radiographic outcomes of transcrestal sinus floor elevation performed using the CAS kit in patients presenting with residual bone height below or above 4 mm. Methods: Forty-five partially edentulous patients who received single implant-supported rehabilitations in the posterior maxilla between September 2021 and October 2024 were included. Patients were allocated to a test group (residual bone height < 4 mm; n = 20) and a control group (residual bone height ≥ 4 mm; n = 25). All procedures were performed using a standardized CAS-kit protocol with hydraulic membrane elevation and xenogeneic bone grafting. The primary outcomes were implant and prosthetic survival rates and the occurrence of biological or technical complications. Secondary outcomes included the radiographic evaluation of residual bone height, final bone height, vertical bone gain, and bone height above the implant apex at implant placement, prosthetic delivery (9 months) and at the 2 years follow-up. Results: No implant or prosthetic failures and no biological or technical complications were recorded, resulting in 100% implant and prosthetic survival rates. Residual bone height was significantly lower in the test group (2.8 ± 0.8 mm) than in the control group (5.3 ± 1.0 mm) (p < 0.001). Despite significantly greater vertical bone gain in the test group (10.9 ± 1.6 mm vs. 8.2 ± 0.6 mm; p < 0.001), comparable final bone heights were observed immediately after augmentation (13.7 ± 1.7 mm vs. 13.5 ± 1.5 mm; p = 0.742) and at prosthetic delivery (12.6 ± 1.6 mm vs. 12.9 ± 1.6 mm; p = 0.556). Bone height above the implant apex was also similar between the groups at both time points. A modest but statistically significant reduction in augmented bone height was observed during healing in both groups. Conclusions: Within the limitations of this retrospective study, transcrestal sinus floor elevation using the hydraulic CAS-kit technique showed favorable clinical and radiographic outcomes in both groups, including sites with residual bone height below 4 mm. These preliminary findings suggest that the crestal approach may represent a treatment option in carefully selected patients with limited residual bone height. However, larger prospective controlled studies with standardized radiographic assessments and longer follow-up periods are needed to confirm these findings.

  • Open Access

    In Vitro Micro-CT Assessment of a Novel Implant–Abutment Connection Under Static and Cyclic Loading

    by Marco Tallarico, Dario Melodia, Lukasz Zadrozny, Carlotta Cacciò, Silvio Mario Meloni, Aurea Immacolata Lumbau, Santo Catapano, Riccardo Baldari, Rafał Molak, Jakub Jaroszewicz, et al.

    The implant–abutment connection (IAC) is a critical determinant of the mechanical and biological performance of dental implants. Connection design and insertion torque may influence fatigue resistance, micromovement, and microgap formation, thereby affecting long-term implant success. This in vitro study evaluated a novel conical implant–abutment connection under controlled mechanical loading conditions. Methods: A sequential in vitro protocol was applied. Mechanical testing was conducted according to ISO 14801:2016 and included static and cyclic loading tests of the KS implant system inserted at two different torque values (35 Ncm and 70 Ncm). High-resolution micro-computed tomography (micro-CT) was performed after mechanical loading to evaluate implant–abutment interface integrity, microstructural alterations, and microgap behavior. Results: Static and cyclic loading tests revealed no observable differences between implants inserted at 35 Ncm and 70 Ncm, with all specimens completing the loading protocols without mechanical failure. Micro-CT analysis showed no evidence of microfractures, permanent deformation, or clinically relevant alterations at the implant–abutment interface. A stable and well-sealed connection was observed for both torque values following mechanical loading. Conclusions: Within the limitations of this in vitro study, the investigated conical implant–abutment connection demonstrated stable mechanical performance and preserved interface integrity after static and cyclic loading, regardless of whether implants were placed at 35 Ncm or 70 Ncm. These findings indicate that, under the present experimental conditions, both torque levels were associated with comparable structural integrity and mechanical stability of the investigated implant–abutment connection. This study should be interpreted as a preliminary experimental investigation, designed to provide descriptive and mechanistic insights rather than statistically powered comparative conclusions. Further long-term clinical trials are required to confirm these preliminary results.

  • Open Access

    Factors Affecting the Implant Supracrestal Complex: A Consensus Paper from the Global Consensus Meeting Organized by the Osstem Implant Community

    by Marco Tallarico, Francesco Grande, Gianluca Fortunato, Carlotta Cacciò, Soo-Young Lee, Young-Jin Cho, Kwan-Tae Noh, Chikahiro Ohkubo, Felipe Aguirre, Recep Uzgur, et al.

    Aim: To develop clear, evidence-based, and standardized guidelines for the design, selection, and clinical use of implant abutments and prosthetic components in order to optimize the biological, mechanical, and esthetic performance of the implant supracrestal complex. Methods: A panel of 10 expert clinicians and researchers in prosthodontics participated in the Osstem Global Consensus Meeting. For the present consensus meeting, a scoping review was performed in advance and discussed among the participants. A comprehensive search of the literature was performed up to June 2025. Two reviewers (M.T. and F.G.) independently conducted screening, data extraction, and quality assessment using the Newcastle–Ottawa Scale. The evidence was synthesized and discussed by the panel of expert clinicians during the consensus meeting. After that, guidelines were developed using a 14-question questionnaire to formulate consensus-based clinical recommendations. The participants answered structured questions and discussed discrepancies to achieve a consensus. Results: The panel of expert clinicians reached a consensus on several prosthetic key points. Concave abutment profiles and emergence angles <30° promoted peri-implant tissue stability, while convex designs and wider angles increased risks of bone loss and peri-implantitis. Titanium remains the reference abutment material in posterior sites, while zirconia provides superior esthetics anteriorly, and hybrid abutments balance strength and esthetics. Conclusions: Prosthetic design and abutment material selection critically affect peri-implant tissue stability and esthetic outcomes. The evidence supports screw-retained designs, platform switching, and the “one abutment–one time” approach for predictable long-term success.


  • Open Access

    Accuracy and Precision of a Novel Digital Impression Workflow with Artificial Intelligence Based Integrated Tool for All-on-X Rehabilitations: A Multicenter Prospective Cohort Study

    by Marco Tallarico, Mohamed Fathy El Ashry, Carlotta Cacciò, Mohammad Qaddomi, Ahmed Ashraf, Mayar Omar, Dalia Ghalwash, Francesco Mattia Ceruso, Silvio Mario Meloni, David Chong

    Background: Digital workflows have significantly improved accuracy and predictability in implant prosthodontics; however, full-arch rehabilitations in completely edentulous patients remain challenging due to the need for precise implant position transfer and passive fit of prosthetic frameworks. Although artificial intelligence (AI)–assisted digital workflows have shown promising results in vitro, prospective clinical evidence remains limited. This study aimed to clinically evaluate the accuracy of a novel AI-integrated digital impression workflow (SmartX) for all-on-X full-arch implant-supported rehabilitations. Methods: This prospective observational case series included 10 completely edentulous patients rehabilitated with all-on-X implant-supported full-arch prostheses. Digital impressions were obtained using extended SmartFlag scan bodies combined with an AI-assisted SmartX workflow and an intraoral scanner. Clinical accuracy was evaluated using visual and tactile inspection, the one-screw (Sheffield) test, and a screw resistance test, all recorded as dichotomous outcomes (acceptable passive fit: yes/no). Secondary outcomes included implant and prosthesis survival rates and the incidence of biological or technical complications. Patients were followed for a minimum of 6 months. Results: A total of 54 implants were placed (mean: 5.4 implants per patient), with no dropouts during follow-up. All cases demonstrated acceptable passive fit according to all accuracy assessments (100% positive outcomes). Progressive screw tightening revealed a consistent angular displacement of approximately 60° in all cases. Implant and prosthesis survival rates were 100%, and no biological or technical complications were observed during the follow-up period. Conclusions: Within the limitations of this prospective clinical study, the SmartX AI-assisted digital workflow combined with extended scan bodies demonstrated high clinical accuracy for full-arch implant-supported rehabilitations. This approach appears to be a reliable and clinically feasible option for digital full-arch prosthodontics. Further studies with larger sample sizes and longer follow-up periods are required to confirm these findings.

  • Open Access

    Factors Affecting the Implant Supracrestal Complex: A Scoping Review as Part of a Global Consensus Meeting Organised by the Osstem Implant Community

    by Marco Tallarico, Francesco Grande, Gianluca Fortunato, Carlotta Cacciò, Soo-Young Lee, Young-Jin Cho, Kwan-Tae Noh, Chikahiro Ohkubo, Felipe Aguirre, Recep Uzgur, et al.

    Aim: To map current evidence and identify key factors influencing peri-implant tissue stability related to abutment configuration, design, materials, and prosthetic protocols in implant-supported fixed prostheses. Methods: A comprehensive search of PubMed and Scopus was performed up to June 2025, supplemented by manual searches. Human studies in English with ≥1 year of follow-up were included. Two reviewers independently conducted screening, data extraction, and quality assessment using the Newcastle–Ottawa Scale. The review was carried out at the Universities of Sassari and Ferrara in collaboration with the Osstem Global Consensus Meeting. Results: From 974 records, 46 studies were included: 33 randomized clinical trials, 9 cohort, 2 case-control, and 2 cross-sectional studies. Thirty-nine were rated as good quality and five as fair. Concave abutment profiles and emergence angles < 30° promoted peri-implant tissue stability, while convex designs and wider angles increased risks of bone loss and peri-implantitis. Titanium remains the reference abutment material in posterior sites, zirconia provides superior aesthetics anteriorly, and hybrid abutments balance strength and esthetics. Conclusions: Prosthetic design and abutment material selection critically affect peri-implant tissue stability and esthetic outcomes. Evidence supports screw-retained designs, platform switching, and the “one abutment–one time” approach for predictable long-term success.

  • Open Access

    Effectiveness of an AI-Assisted Digital Workflow for Complete-Arch Implant Impressions: An In Vitro Comparative Study

    by Marco Tallarico, Mohammad Qaddomi, Elena De Rosa, Carlotta Cacciò, Silvio Mario Meloni, Ieva Gendviliene, Wael Att, Rim Bourgi, Aurea Maria Lumbau, Gabriele Cervino

    Background: The accuracy and consistency of complete-arch digital impressions are fundamental for long-term success of implant-supported rehabilitations. Recently, artificial intelligence (AI)-assisted tools, such as SmartX (Medit Link v3.4.2, MEDIT Corp., Seoul, South of Korea), have been introduced to enhance scan body recognition and data alignment during intraoral scanning. Objective: This in vitro study aimed to evaluate the impact of SmartX on impression accuracy, consistency, operator confidence, and technique sensitivity in complete-arch implant workflows. Methods: Seventy-two digital impressions were recorded on edentulous mandibular models with four dummy implants, using six experimental subgroups based on scan body design (double- or single-wing), scanning technique (occlusal or combined straight/zigzag), and presence/absence of SmartX tool. Each group was scanned by both an expert and a novice operator (n = 6 scans per subgroup). Root mean square (RMS) deviation and scanning time were assessed. Data were tested for normality (Shapiro–Wilk). Parametric tests (t-test, repeated measures ANOVA with Greenhouse–Geisser correction) or non-parametric equivalents (Mann–Whitney U, Friedman) were applied as appropriate. Post hoc comparisons used Tukey HSD or Dunn–Bonferroni tests (α = 0.05). Results: SmartX significantly improved consistency and operator confidence, especially among novices, although it did not yield statistically significant differences in scan accuracy (p > 0.05). The tool mitigated early scanning errors and reduced dependence on operator technique. SmartX also enabled successful library alignment with minimal data; however, scanning time was generally longer with its use, particularly for beginners. Conclusions: While SmartX did not directly enhance trueness, it substantially improved scan reliability and user experience in complete-arch workflows. Its ability to minimize technique sensitivity and improve reproducibility makes it a valuable aid in both training and clinical settings. Further clinical validation is warranted to support its integration into routine practice.


  • Open Access

    A Second Chance: Managing Late Implant Failure from Peri-Implantitis with Computer-Guided Bone Regeneration—A Clinical Case Report

    by Marco Tallarico, Silvio Mario Meloni, Carlotta Cacciò, Francesco Mattia Ceruso, Aurea Immacolata Lumbau

    Background and Clinical Significance: The retreatment of failed dental implants remains a challenging clinical scenario, particularly when complicated by peri-implantitis and as sociated bone loss. Successful management requires a comprehensive and predictable approach that addresses both hard and soft tissue deficiencies. Case Presentation: This case report illustrates a fully digital, prosthetically driven workflow for the rehabilitation of a posterior mandibular site following implant failure. A 44-year-old female patient underwent removal of a failing implant and adjacent tooth due to advanced peri-implantitis and periodontitis. After healing, a digital workflow—including intraoral scanning, cone-beam computed tomography (CBCT), and virtual planning—was employed to design and fabricate a customized CAD/CAM titanium mesh for vertical guided bone regeneration. The grafting procedure utilized a composite mixture of autogenous bone and anorganic bovine bone (A-Oss). After nine months of healing, two implants with a hydrophilic surface (SOI) were placed using a fully guided surgical protocol (OneGuide system). Subsequent soft tissue grafting and final prosthetic rehabilitation with monolithic zirconia restorations resulted in stable functional and aesthetic outcomes. Conclusions: This case highlights how the integration of modern digital technologies with advanced regenerative procedures and innovative implant surfaces can enhance the predictability and long-term success of implant retreatment in compromised posterior sites.


  • Open Access

    The Role of Digital Workflow in Creating a New, Esthetic and Functional Smile in a Periodontally Compromised Patient: A Case Report

    by Carlotta Cacciò, Marco Tallarico, Aurea Immacolata Lumbau, Francesco Mattia Ceruso, Milena Pisano

    Background and Clinical Significance: Prosthetic rehabilitation in the aesthetic zone of periodontally compromised patients presents a complex clinical challenge, requiring a careful coordination of aesthetic, functional, and biological demands. This case highlights the benefits of digital dentistry, interdisciplinary collaboration, and regular maintenance in achieving long-term success in complex rehabilitations of periodontally compromised patients. Case Presentation: This case report describes the digital minimally invasive rehabilitation of a 39-year-old male patient with Stage III periodontitis, occlusal discrepancies, tooth mobility, and an interincisal diastema. A fully digital workflow—including intraoral scanning, aesthetic previewing, and mandibular motion analysis—was employed to guide diagnosis, treatment planning, and prosthetic execution. Conservative tooth preparations using a biologically oriented approach (BOPT) were combined with customised provisional restorations to support soft tissue conditioning and functional control throughout the provisional phases. Mandibular motion tracking facilitated the design of a personalised anterior guidance to improve occlusion and correct the deep bite. The interincisal diastema was initially maintained then closed during the advanced phase of treatment based on aesthetic simulations and patient preference. One unplanned endodontic treatment was required during the provisional phase, but no other complications occurred. Conclusions: At the four-year follow-up, the patient demonstrated stable periodontal and occlusal conditions, improved clinical indices, and high satisfaction with the aesthetic outcome.


  • Open Access

    A Quality Study on Patients’ Perceptions After Digitally Driven Smile Creation Including Aligners and Minimally Invasive Prosthetic Restorations

    by Marco Tallarico, Aurea Immacolata Lumbau, Mariapia Sorrenti, Roberta Lione, Carlotta Cacciò, Marco Annucci, Silvio Mario Meloni, Milena Pisano

    Background: Aesthetic dentistry increasingly demands minimally invasive, predictable, and patient-centered solutions. Digital technologies and AI-driven planning tools are now integral to interdisciplinary treatments. Aim: To evaluate, by means of a 16-item questionnaire, patients’ perceptions of smile aesthetics and oral function before and after receiving clear aligner therapy followed by minimally invasive ceramic veneers, using digital planning and Smile Creator software. Materials and Methods: Five adult patients underwent digital smile design, clear aligner therapy, and feldspathic veneer placement. Pre- and post-treatment perceptions of smile aesthetics and function were assessed using a structured questionnaire. AI-based simulation tools (2D and 4 K TruSmile video previews) were incorporated. Paired t-tests were used to compare outcomes before and after treatment. Results: Mean pre-treatment scores were 4.8 for smile aesthetics and 6.6 for function. Post-treatment scores significantly improved to 9.8 (p = 0.001) and 9.4 (p = 0.002), respectively. Patients rated AI-generated smile previews more favorably than 2D designs and acknowledged the value of digital tools in understanding and accepting treatment. Conclusions: The integration of digital and AI-based tools in aesthetic dentistry enhances patient communication, improves predictability, and enables minimally invasive treatment. Patient satisfaction was high, underscoring the effectiveness of the combined orthodontic and prosthetic approach.


  • Open Access

    A Quality Study on Patients’ Perception of Aesthetics and Function After Digitally Driven Smile Creation with a Combined Approach Including Aligners and Minimally Invasive Prosthetic Restorations

    by Marco Tallarico, Aurea Maria Immacolata Lumbau, Mariapia Sorrenti, Roberta Lione, Carlotta Cacciò, Marco Annucci, Silvio Mario Meloni, Milena Pisano

    Background: Aesthetic dentistry increasingly demands minimally invasive, predictable, and patient-centered solutions. Digital technologies and AI-driven planning tools are now integral to interdisciplinary treatments. Aim: To evaluate patients’ perception of smile aesthetics and oral function before and after receiving clear aligner therapy followed by minimally invasive ceramic veneers, using digital planning and pre-visualization tools. Materials and Methods: five adult patients underwent digital smile design, clear aligner therapy, and feldspathic veneer placement. Pre- and post-treatment perception of smile aesthetics and function were assessed using a structured questionnaire. AI-based simulation tools (2D and 4K TruSmile video previews) were incorporated. Paired t-tests were used to compare outcomes before and after treatment. Results: Mean pre-treatment scores were 4.8 for smile aesthetics and 6.6 for function. Post-treatment scores significantly improved to 9.8 (p = 0.001) and 9.4 (p = 0.002), respectively. Patients rated AI-generated smile previews more favorably than 2D designs and acknowledged the value of digital tools in understanding and accepting treatment. Conclusions : The integration of digital and AI-based tools in aesthetic dentistry enhances patient communication, improves predictability, and enables minimally invasive treatment. Patient satisfaction was high, underscoring the effectiveness of the combined orthodontic and prosthetic approach.