Serhii Bilyk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Serhii Bilyk has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Artem Bilyk
Kyiv National University of Construction and Architecture
7 shared publications - Ol-R Shugaylo
Державне підприємство «Державний науково-технічний центр з ядерної та радіаційної безпеки», м. Київ, Україна
6 shared publications - Vitalii Tonkacheiev
Kyiv National University of Construction and Architecture
4 shared publications - Dmytro Bitiukov
Kyiv National University of Construction and Architecture
3 shared publications - Oleksandr Glitin3 shared publications
- Hennadii Tonkacheiev
Kyiv National University of Construction and Architecture
2 shared publications
Latest Publications
- Open Access
- 28 May 2026
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 116
A protective shelter sheet steel structural behaviour numerical simulation when hit by a fragment from an impacting UAV
It has been determined that, under the conditions of the war of the russian federation against Ukraine, the problem of selecting cost-effective and efficient solutions for the design of protective shelters is highly relevant. A review of the literature has shown that previous studies focused on the behaviour of protective structures subjected to small-arms bullet impacts, while the impact of fragments from strike UAVs has not been considered. It is noted that steel plate protective structures are advantageous due to the high speed of construction. From practical experience in the design of protective shelters, it is known that, due to the limited availability of armored steel plate sizes, plate structures must be designed as multilayer systems. It is proposed to use single-layer plate structures of greater thickness made of low-alloy steel with lower strength. Numerical modeling of fragment penetration from a strike UAV into steel structures of protective shelters under the conditions of Ukraine was carried out. The size, velocity, and material parameters of the fragment were adopted in accordance with the strike UAV used by the adversary. A dynamic analysis was performed using the finite element method with the ANSYS software package. To model the material behaviour of steel, the Johnson–Cook model was adopted—an empirical material model used to describe the behaviour of metals under large deformations, high strain rates, and elevated temperatures. Two numerical simulations were conducted for different thicknesses of steel plates for both armored steel and low-alloy steel. The sufficient thickness required to prevent fragment penetration was determined for steel plates made of armored and low-alloy steel. It was established that, instead of multilayer armored steel plate structures, single-layer structures made of low-alloy steel can be used in protective shelters, providing several-fold reductions in material cost. The results of this study make it possible to apply more economical and less labor-intensive structural solutions in the design of protective shelters, with a reduced number of welded assembly connections.
- 28 May 2026
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 116
Open AccessA protective shelter sheet steel structural behaviour numerical simulation when hit by a fragment from an impacting UAV
It has been determined that, under the conditions of the war of the russian federation against Ukraine, the problem of selecting cost-effective and efficient solutions for the design of protective shelters is highly relevant. A review of the literature has shown that previous studies focused on the behaviour of protective structures subjected to small-arms bullet impacts, while the impact of fragments from strike UAVs has not been considered. It is noted that steel plate protective structures are advantageous due to the high speed of construction. From practical experience in the design of protective shelters, it is known that, due to the limited availability of armored steel plate sizes, plate structures must be designed as multilayer systems. It is proposed to use single-layer plate structures of greater thickness made of low-alloy steel with lower strength. Numerical modeling of fragment penetration from a strike UAV into steel structures of protective shelters under the conditions of Ukraine was carried out. The size, velocity, and material parameters of the fragment were adopted in accordance with the strike UAV used by the adversary. A dynamic analysis was performed using the finite element method with the ANSYS software package. To model the material behaviour of steel, the Johnson–Cook model was adopted—an empirical material model used to describe the behaviour of metals under large deformations, high strain rates, and elevated temperatures. Two numerical simulations were conducted for different thicknesses of steel plates for both armored steel and low-alloy steel. The sufficient thickness required to prevent fragment penetration was determined for steel plates made of armored and low-alloy steel. It was established that, instead of multilayer armored steel plate structures, single-layer structures made of low-alloy steel can be used in protective shelters, providing several-fold reductions in material cost. The results of this study make it possible to apply more economical and less labor-intensive structural solutions in the design of protective shelters, with a reduced number of welded assembly connections.
- Open Access
- 27 February 2026
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 1 (7 (139)) , 26-37
Effect of concentrated impulse loading (impact) on massive, glulam, and cross-laminated timber beams
In this study, massive, glulam, and cross-laminated timber beams of rectangular cross-section were examined under a concentrated impulse loading (impact). The task addressed was to determine and compare the deformation and dynamic characteristics of beams made of different types of timber under short-term impact. During experimental studies, dependences of displacements over time were established; oscillation oscillograms were constructed; spectral analysis was performed, and the frequencies of free oscillations (fMT,exp = 75 Hz, fGLT,exp = 73 Hz, fCLT,exp = 67 Hz) and logarithmic damping decrements (βMT,mean = 0.222, βGLT,mean = 0.100, βCLT,mean = 0.092) were determined for each type of beam. It was found that a cross-laminated timber beam is characterized by the lowest deformation resistance and the lowest oscillation damping rate. Glue-laminated timber (glulam), in comparison with solid timber, demonstrates a smaller maximum displacement and a lower oscillation damping rate. The results are attributed to the peculiarities of internal structure of the materials, the orientation of the fibers, the presence of adhesive layers, and the nature of the interlayer interaction, which significantly affect the stiffness, damping properties, and distribution of impact energy. A distinctive feature of the findings is the experimentally confirmed comparison of the dynamic response of beams made of different wooden based materials under the same loading conditions, which made it possible to reasonably assess their effectiveness under the action of impulse influences and solve the research problem. This study's results could be used in the design of timber load-bearing elements of buildings and structures subjected to dynamic or impact loads, as well as to refine calculation models, determine dynamic coefficients, and assess the effectiveness of using solid, glued, and cross-glued wood
- 27 February 2026
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 1 (7 (139)) , 26-37
Open AccessEffect of concentrated impulse loading (impact) on massive, glulam, and cross-laminated timber beams
In this study, massive, glulam, and cross-laminated timber beams of rectangular cross-section were examined under a concentrated impulse loading (impact). The task addressed was to determine and compare the deformation and dynamic characteristics of beams made of different types of timber under short-term impact. During experimental studies, dependences of displacements over time were established; oscillation oscillograms were constructed; spectral analysis was performed, and the frequencies of free oscillations (fMT,exp = 75 Hz, fGLT,exp = 73 Hz, fCLT,exp = 67 Hz) and logarithmic damping decrements (βMT,mean = 0.222, βGLT,mean = 0.100, βCLT,mean = 0.092) were determined for each type of beam. It was found that a cross-laminated timber beam is characterized by the lowest deformation resistance and the lowest oscillation damping rate. Glue-laminated timber (glulam), in comparison with solid timber, demonstrates a smaller maximum displacement and a lower oscillation damping rate. The results are attributed to the peculiarities of internal structure of the materials, the orientation of the fibers, the presence of adhesive layers, and the nature of the interlayer interaction, which significantly affect the stiffness, damping properties, and distribution of impact energy. A distinctive feature of the findings is the experimentally confirmed comparison of the dynamic response of beams made of different wooden based materials under the same loading conditions, which made it possible to reasonably assess their effectiveness under the action of impulse influences and solve the research problem. This study's results could be used in the design of timber load-bearing elements of buildings and structures subjected to dynamic or impact loads, as well as to refine calculation models, determine dynamic coefficients, and assess the effectiveness of using solid, glued, and cross-glued wood
- Open Access
- 25 April 2025
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 114,p. 155-164
Rational topology of steel i-beams with various gradients of changing wall height and shelf width at specified sections along the length of the beam
A methodological approach has been developed for determining the rational topology of steel I-beams with variable stiffness under uniformly distributed loading along the beam length. It has been shown that for such beams, with varying web height and flange width, the maximum stress does not occur in the section where the maximum bending moment acts. The problem of finding the optimal cross-sectional height is solved using the Lagrange multipliers method in conjunction with the Kuhn–Tucker conditions. For steel I-beams with variable web height and flange width, the sufficient condition for structural optimality is confirmed: the area of the web is equal to the total area of the two flanges. However, under linear reduction of web height and flange width in the direction of decreasing bending moments, new critical cross-sections arise along the beam length in which the normal stresses in the flanges exceed those in the section with the maximum bending moment. This indicates that beams with variable stiffness may have multiple governing sections. An improved physical–mathematical model of the stress–strain state of I-beams in bending is proposed. A steel I-beam with the proposed new topology has the ability to adapt to its stress–strain state by introducing reverse variation of flange width: in selected sections, the beam height decreases or remains constant, while the flange width and accordingly the flange cross-sectional area increases relative to the section where the maximum bending moment acts. This improved design approach allows for achieving stress levels in all current cross-sections that do not exceed the yield strength of steel along the entire length of the I-beam. The numerical studies conducted demonstrate the possibility of finding new rational design solutions for variable cross-section steel I-beams. The existence of an admissible set of rational solutions based on the obtained results has also been confirmed. Thus, the problem of determining the rational topology of steel I-beams with linearly varying flange width and web height represents a design task with appropriately formulated and adequate design condition.
- 25 April 2025
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 114,p. 155-164
Open AccessRational topology of steel i-beams with various gradients of changing wall height and shelf width at specified sections along the length of the beam
A methodological approach has been developed for determining the rational topology of steel I-beams with variable stiffness under uniformly distributed loading along the beam length. It has been shown that for such beams, with varying web height and flange width, the maximum stress does not occur in the section where the maximum bending moment acts. The problem of finding the optimal cross-sectional height is solved using the Lagrange multipliers method in conjunction with the Kuhn–Tucker conditions. For steel I-beams with variable web height and flange width, the sufficient condition for structural optimality is confirmed: the area of the web is equal to the total area of the two flanges. However, under linear reduction of web height and flange width in the direction of decreasing bending moments, new critical cross-sections arise along the beam length in which the normal stresses in the flanges exceed those in the section with the maximum bending moment. This indicates that beams with variable stiffness may have multiple governing sections. An improved physical–mathematical model of the stress–strain state of I-beams in bending is proposed. A steel I-beam with the proposed new topology has the ability to adapt to its stress–strain state by introducing reverse variation of flange width: in selected sections, the beam height decreases or remains constant, while the flange width and accordingly the flange cross-sectional area increases relative to the section where the maximum bending moment acts. This improved design approach allows for achieving stress levels in all current cross-sections that do not exceed the yield strength of steel along the entire length of the I-beam. The numerical studies conducted demonstrate the possibility of finding new rational design solutions for variable cross-section steel I-beams. The existence of an admissible set of rational solutions based on the obtained results has also been confirmed. Thus, the problem of determining the rational topology of steel I-beams with linearly varying flange width and web height represents a design task with appropriately formulated and adequate design condition.
- Open Access
- 25 April 2025
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 114,p. 101-110
Comparison of experimentally obtained and theoretically determined in the Dlubal RFEM 5 software physical and mechanical properties of massive, glued laminated and cross-laminated timber beams
The article presents the results of research and verification of experimentally obtained physical and mechanical characteristics of beams made of massive, glued laminated (glulam) and cross-laminated timber (CLT). The purpose of the study is to compare the real and theoretical deflections of the beams, determined with the Dlubal RFEM 5 finite element analysis software. Previously, experimental studies were conducted to determine the modified deformation modulus (deformation modulus with consideration of influence of shear modulus) for each type of timber beams. The modeling was performed in three stages: using 1D member finite elements, 3D Solid finite elements and a 3D Solid model of the CLT beam considering the orientation of the lamellae fibers in each layer. For each type of timber beam, characteristics were determined for the corresponding material models: isotropic linear-elastic material model for 1D finite elements and orthotropic linear-elastic 3D material model for 3D finite elements. Theoretically calculated deflections were compared with experimentally obtained values, which made it possible to evaluate the accuracy of each model. The results showed high accuracy of modeling for massive and glulam timber beams with an error of up to 2%. For CLT beams, an underestimation of the theoretical deflections for models from 1D and 3D finite elements and an overestimation of theoretical deflections for models from 3D finite elements, taking into account the orientation of the fibers of the lamellae, was noted. The research confirms the expediency of using both simplified and detailed models in the analysis of deformations of timber structures. To increase the accuracy of the calculations, it is recommended to further refine the characteristics of the studied materials, in particular, the dependence between the deformation modulus and the shear modulus, as well as considering complex loading conditions, types of supports, and long-term effects in future studies. It is also advisable to carry out additional experiments to clarify the parameters of strength and stiffness characteristic of various configurations of cross-glued beams.
- 25 April 2025
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 114,p. 101-110
Open AccessComparison of experimentally obtained and theoretically determined in the Dlubal RFEM 5 software physical and mechanical properties of massive, glued laminated and cross-laminated timber beams
The article presents the results of research and verification of experimentally obtained physical and mechanical characteristics of beams made of massive, glued laminated (glulam) and cross-laminated timber (CLT). The purpose of the study is to compare the real and theoretical deflections of the beams, determined with the Dlubal RFEM 5 finite element analysis software. Previously, experimental studies were conducted to determine the modified deformation modulus (deformation modulus with consideration of influence of shear modulus) for each type of timber beams. The modeling was performed in three stages: using 1D member finite elements, 3D Solid finite elements and a 3D Solid model of the CLT beam considering the orientation of the lamellae fibers in each layer. For each type of timber beam, characteristics were determined for the corresponding material models: isotropic linear-elastic material model for 1D finite elements and orthotropic linear-elastic 3D material model for 3D finite elements. Theoretically calculated deflections were compared with experimentally obtained values, which made it possible to evaluate the accuracy of each model. The results showed high accuracy of modeling for massive and glulam timber beams with an error of up to 2%. For CLT beams, an underestimation of the theoretical deflections for models from 1D and 3D finite elements and an overestimation of theoretical deflections for models from 3D finite elements, taking into account the orientation of the fibers of the lamellae, was noted. The research confirms the expediency of using both simplified and detailed models in the analysis of deformations of timber structures. To increase the accuracy of the calculations, it is recommended to further refine the characteristics of the studied materials, in particular, the dependence between the deformation modulus and the shear modulus, as well as considering complex loading conditions, types of supports, and long-term effects in future studies. It is also advisable to carry out additional experiments to clarify the parameters of strength and stiffness characteristic of various configurations of cross-glued beams.
- Open Access
- 28 February 2025
- Published by Kyiv National University of Construction and Architecture in Spatial development
- No. 11
DETERMINATION AND ANALYSIS OF PHYSICAL AND MECHANICAL PROPERTIES OF SOLID, GLUED LAMINATED AND CROSS-LAMINATED TIMBER BEAMS
The article presents comprehensive experimental studies of the deformative characteristics of three types of wood structural materials: solid, glulam and cross-laminated timber. The main objective of the study was to assess the mechanical properties, efficiency and behavior of these materials. The experimental approach included an analysis of the relationships between force and deflection, calculated modified deformation moduli (deformation moduli taking into account shear moduli), and constructed experimental graphs of deformations and deformation moduli of the studied specimens. Transition coefficients between the studied wood types were determined. This analysis provided a clear understanding of the mechanical responses of each type of material under load. The results obtained indicate a reduced deformation resistance of cross-laminated timber compared to solid and glulam timber along the fibers. Glulam showed comparable results to solid timber. Each material demonstrates unique advantages, which emphasizes their suitability for specific structural applications based on loads and operational requirements. Further research is recommended to assess the behavior of these materials under different environmental conditions, the effect of varying the number of layers of glulam and cross‑laminated timber. Such research will provide a deeper understanding of the durability and performance of wood-based materials in various construction contexts and expand their applications in innovative architectural and engineering solutions.
- 28 February 2025
- Published by Kyiv National University of Construction and Architecture in Spatial development
- No. 11
Open AccessDETERMINATION AND ANALYSIS OF PHYSICAL AND MECHANICAL PROPERTIES OF SOLID, GLUED LAMINATED AND CROSS-LAMINATED TIMBER BEAMS
The article presents comprehensive experimental studies of the deformative characteristics of three types of wood structural materials: solid, glulam and cross-laminated timber. The main objective of the study was to assess the mechanical properties, efficiency and behavior of these materials. The experimental approach included an analysis of the relationships between force and deflection, calculated modified deformation moduli (deformation moduli taking into account shear moduli), and constructed experimental graphs of deformations and deformation moduli of the studied specimens. Transition coefficients between the studied wood types were determined. This analysis provided a clear understanding of the mechanical responses of each type of material under load. The results obtained indicate a reduced deformation resistance of cross-laminated timber compared to solid and glulam timber along the fibers. Glulam showed comparable results to solid timber. Each material demonstrates unique advantages, which emphasizes their suitability for specific structural applications based on loads and operational requirements. Further research is recommended to assess the behavior of these materials under different environmental conditions, the effect of varying the number of layers of glulam and cross‑laminated timber. Such research will provide a deeper understanding of the durability and performance of wood-based materials in various construction contexts and expand their applications in innovative architectural and engineering solutions.
- 23 December 2024
- Published by Kyiv National University of Construction and Architecture in Building constructions. Theory and Practice
- No. 15
An effective method for strengthening steel beams and purlins using an elastic support in the span
The article is devoted to the development of theoretical approaches to strengthening bending elements, such as beams and girders, through the installation of an elastic support at the midpoint of the span where the maximum bendingmoment occurs, as well as the development of a practical calculation method for such reinforcement. The need for strengthening may arise under various conditions, including prolonged operation beyond the design lifespan, increased service loads on existing structures, wear and tear of structures, or damage caused by episodic additional loads (e.g.,earthquakes, explosions). The purpose of the study is to provide a practical method for reinforcing girders and beams using an elastic support at the span to increase the load-bearing capacity of structures under increased loads (e.g., installation of solar power stations or other additional equipment on roofs) or in cases of damage caused by explosions or other episodic loads that reduce the cross-sectional geometric characteristics and require rapid strengthening. The article proposes a calculation methodology for this type of reinforcement that addresses shortcomings in existing scientific and technical literature and facilitates the broader implementation of the method to enhance the reliability of structures.The article presents an effective method for reinforcing girders and beams in response to increased loading. Using an elastic support (brace) at the span enhances the load-bearing capacity of structures.The method involves installing a brace under the element to be strengthened, secured with additional bolts to create an elastic support that reduces the applied load. This solution eliminates the need for welding or disrupting the structural integrity. Atechnological gap is provided to create pre-stressing, which is closed during bolt tightening. The main advantages include minimal intervention, pre-stressing creation, and increased structural reliability. The article contains a calculation methodology for this reinforcement method, promoting its practical application to improve the efficiency and reliability of structures.The proposed reinforcement method is demonstrated on steel structures but can be extended, if necessary, to structures made of other materials, such as wood or reinforced concrete.
- 23 December 2024
- Published by Kyiv National University of Construction and Architecture in Building constructions. Theory and Practice
- No. 15
An effective method for strengthening steel beams and purlins using an elastic support in the span
The article is devoted to the development of theoretical approaches to strengthening bending elements, such as beams and girders, through the installation of an elastic support at the midpoint of the span where the maximum bendingmoment occurs, as well as the development of a practical calculation method for such reinforcement. The need for strengthening may arise under various conditions, including prolonged operation beyond the design lifespan, increased service loads on existing structures, wear and tear of structures, or damage caused by episodic additional loads (e.g.,earthquakes, explosions). The purpose of the study is to provide a practical method for reinforcing girders and beams using an elastic support at the span to increase the load-bearing capacity of structures under increased loads (e.g., installation of solar power stations or other additional equipment on roofs) or in cases of damage caused by explosions or other episodic loads that reduce the cross-sectional geometric characteristics and require rapid strengthening. The article proposes a calculation methodology for this type of reinforcement that addresses shortcomings in existing scientific and technical literature and facilitates the broader implementation of the method to enhance the reliability of structures.The article presents an effective method for reinforcing girders and beams in response to increased loading. Using an elastic support (brace) at the span enhances the load-bearing capacity of structures.The method involves installing a brace under the element to be strengthened, secured with additional bolts to create an elastic support that reduces the applied load. This solution eliminates the need for welding or disrupting the structural integrity. Atechnological gap is provided to create pre-stressing, which is closed during bolt tightening. The main advantages include minimal intervention, pre-stressing creation, and increased structural reliability. The article contains a calculation methodology for this reinforcement method, promoting its practical application to improve the efficiency and reliability of structures.The proposed reinforcement method is demonstrated on steel structures but can be extended, if necessary, to structures made of other materials, such as wood or reinforced concrete.
- Open Access
- 29 November 2024
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 113,p. 45-55
Development of general principles of fatigue strength assessment steel structures of nuclear power plants units considering special operation conditions
The fatigue strength of the steel structures of nuclear power plants determines the possible period of their safe operation in terms of fatigue damage accumulation. These structures are locatedin special operation conditions, including elevated temperatures of environmental conditions, episodic temperature loads with a significant temperature gradient, etc. Reliable assessment of the fatigue strength of steel structures is of particular relevance because most units at Ukrainian nuclear power plants have already exhausted their design life and are at the stage of long-term operation. At the same time, in terms of fatigue strength assessment, state building codes are focused on traditional steel structures subjected to standard loads and impacts and do not take into account these special operating conditions. Nuclear and radiation safety regulations do not contain technical requirements for calculating the fatigue strength of steel structures and establish only general regulatory requirements. The article develops and formulates general principles of fatigue strength assessment of steel structures of nuclear power plants, taking into account the special operation conditions, as well as the degree of their responsibility for ensuring nuclear and radiation safety.
- 29 November 2024
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 113,p. 45-55
Open AccessDevelopment of general principles of fatigue strength assessment steel structures of nuclear power plants units considering special operation conditions
The fatigue strength of the steel structures of nuclear power plants determines the possible period of their safe operation in terms of fatigue damage accumulation. These structures are locatedin special operation conditions, including elevated temperatures of environmental conditions, episodic temperature loads with a significant temperature gradient, etc. Reliable assessment of the fatigue strength of steel structures is of particular relevance because most units at Ukrainian nuclear power plants have already exhausted their design life and are at the stage of long-term operation. At the same time, in terms of fatigue strength assessment, state building codes are focused on traditional steel structures subjected to standard loads and impacts and do not take into account these special operating conditions. Nuclear and radiation safety regulations do not contain technical requirements for calculating the fatigue strength of steel structures and establish only general regulatory requirements. The article develops and formulates general principles of fatigue strength assessment of steel structures of nuclear power plants, taking into account the special operation conditions, as well as the degree of their responsibility for ensuring nuclear and radiation safety.
- Open Access
- 28 June 2024
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 3 (1 (129)) , 69-79
Revealing the influence of wind vortex shedding on the stressed-strained state of steel tower structures with solid cross-section
This work investigated the effect of vortex shedding during the action of wind on tower structures with a solid cross-section. Failure to take into account this influence, together with the manifestation of the phenomena of physical wear of structures during long-term operation, can lead to building accidents. The object of the research are tower structures with a solid cross-section, which are widely used in modern infrastructure ‒ advertising pylons with a transparent advertising structure with a height of about 12, 22, 25 m, and a flagpole with a height of 48 m. The most frequent manifestations of oscillations according to the first natural frequency and shape have been considered, which occur even with moderate winds and when a large number of oscillation cycles occur. In this work, the number of oscillating cycles per year was determined and estimated based on the archive of meteorological observations. It was found that the number of oscillating cycles due to the action of wind excitation for the example of the structures under study is from 2.6 to 14.4 million per year, which requires the mandatory limitation of stresses in the parts of structures during the design to enable their durability. The magnitude of forces from vortex shedding for the studied structures ranges from 2.9 to 43.5 % of the forces caused by the influence of the frontal wind, depending on the height of the structure. Thus, it was found that the influence of vortex shedding is very insignificant for structures up to 12–15 m high and increases for structures 20 m and higher. Rational forms of the cross-sections of structures were established to reduce the influence of vortex shedding ‒ these are cross-sections of a circular and a cross-section close to it. In a general formulation, these are sections for which peak stresses relative to forces in one plane fall into the neutral zone for stresses from forces in another plane. Recommendations have been also given on the simultaneous consideration of forces from the action of frontal wind on the structure and vortex shedding since both manifestations of wind action on tower structures cannot be separated
- 28 June 2024
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 3 (1 (129)) , 69-79
Open AccessRevealing the influence of wind vortex shedding on the stressed-strained state of steel tower structures with solid cross-section
This work investigated the effect of vortex shedding during the action of wind on tower structures with a solid cross-section. Failure to take into account this influence, together with the manifestation of the phenomena of physical wear of structures during long-term operation, can lead to building accidents. The object of the research are tower structures with a solid cross-section, which are widely used in modern infrastructure ‒ advertising pylons with a transparent advertising structure with a height of about 12, 22, 25 m, and a flagpole with a height of 48 m. The most frequent manifestations of oscillations according to the first natural frequency and shape have been considered, which occur even with moderate winds and when a large number of oscillation cycles occur. In this work, the number of oscillating cycles per year was determined and estimated based on the archive of meteorological observations. It was found that the number of oscillating cycles due to the action of wind excitation for the example of the structures under study is from 2.6 to 14.4 million per year, which requires the mandatory limitation of stresses in the parts of structures during the design to enable their durability. The magnitude of forces from vortex shedding for the studied structures ranges from 2.9 to 43.5 % of the forces caused by the influence of the frontal wind, depending on the height of the structure. Thus, it was found that the influence of vortex shedding is very insignificant for structures up to 12–15 m high and increases for structures 20 m and higher. Rational forms of the cross-sections of structures were established to reduce the influence of vortex shedding ‒ these are cross-sections of a circular and a cross-section close to it. In a general formulation, these are sections for which peak stresses relative to forces in one plane fall into the neutral zone for stresses from forces in another plane. Recommendations have been also given on the simultaneous consideration of forces from the action of frontal wind on the structure and vortex shedding since both manifestations of wind action on tower structures cannot be separated
- Open Access
- 17 April 2024
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 112,p. 229-238
Aluminum dome structures' stability study
The large spans dome structures made of aluminum alloys work is considered. The dome elements material choice is due to the lower weight compared to steel elements, the material corrosion resistance and the lower thermal expansion coefficient. An existing scientific research analysis related to the structures made of aluminum or aluminum alloys stability loss problem was carried out. A two-rod three-hinged model — the von Mises truss (MT) — was used as the research model. The normal stresses on relative deformations dependences graphs for a low-pitched truss with rod inclination angles of 80 and 85 degrees from the vertical for aluminum alloy 5083 with different tubular profiles thicknesses were obtained. The research was carried out in accordance with the provisions described in DSTU-NB EN 1999. An analytical expressions system was derived for determining the aluminum alloy elasticity modulus on strain diagrams. Analytical dependences describing the aluminum MT trusses' operation for all alloys with known mechanical and deformation properties have been obtained. The relative concentrated force in the truss's ridge node on the relative vertical deformations dependences graphs are plotted, taking into account the geometric and physical nonlinear material operation. The conducted research practical significance is that the obtained dependencies allow modeling the MT trusses with aluminum-based rods operation, taking into account various truss geometries. When modeling trusses, an inclined load and the presence of elastic supports in the ridge node were taken into account. Dependencies make it possible to predict the aluminum ribbed-ring domes stability loss, which are modeled by MT trusses. Розглядаються робота купольних конструкцій великих прольотів зі сплавів алюмінію. Вибір матеріалу елементів куполу обумовлений меншою вагою у порівнянні зі сталевими елементами, корозійною стійкістю матеріалу, меншим коефіцієнтом теплового розширення.Проведено аналіз існуючих наукових досліджень пов’язаних із проблемою втрати стійкості конструкцій, що виготовлено з алюмінію або алюмінієвих сплавів. Досліджена проблема втрати стійкості конструкцій ребристо-кільцевих куполів виконаних з алюмінієвих сплавів. У якості моделі дослідження використано двострижневу тришарнірну модель — ферму фон-Мізеса (ФМ). Отримано графіки залежностей нормальних напружень від відносних деформацій для положистої ферми з кутами нахилу стрижнів — 80 та 85 градусів від вертикалі для сплаву алюмінію 5083, різних за товщиною трубчастих профілів. Дослідження виконувались відповідно до положень, що описані в ДСТУ-Н Б EN 1999. Виведено систему аналітичних виразів для визначення модуля пружності алюмінієвого сплаву на діаграмах розтяту. Отримано аналітичні залежності, що описують роботу ферм ФМ з алюмінію для всіх сплавів, для яких відомі механічні та деформаційні властивості. Побудовано графіки залежностей відносної зосередженої сили в гребеневому вузлу ферми від відносних вертикальних деформацій з урахуванням геометричної та фізичної нелінійної роботи матеріалу. Практична значимість проведених досліджень полягає в тому, що отримані залежності дозволяють моделювати роботу ферм ФМ зі стрижнями на основі алюмінію із урахуванням різноманітної геометрії ферми. При моделювання ферм враховується наявність похилого навантаження та присутність пружних опор в гребеневому вузлу. Залежності дозволяють прогнозувати втрату стійкості алюмінієвих ребристо–кільцевих куполів, які моделюються фермами ФМ.
- 17 April 2024
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 112,p. 229-238
Open AccessAluminum dome structures' stability study
The large spans dome structures made of aluminum alloys work is considered. The dome elements material choice is due to the lower weight compared to steel elements, the material corrosion resistance and the lower thermal expansion coefficient. An existing scientific research analysis related to the structures made of aluminum or aluminum alloys stability loss problem was carried out. A two-rod three-hinged model — the von Mises truss (MT) — was used as the research model. The normal stresses on relative deformations dependences graphs for a low-pitched truss with rod inclination angles of 80 and 85 degrees from the vertical for aluminum alloy 5083 with different tubular profiles thicknesses were obtained. The research was carried out in accordance with the provisions described in DSTU-NB EN 1999. An analytical expressions system was derived for determining the aluminum alloy elasticity modulus on strain diagrams. Analytical dependences describing the aluminum MT trusses' operation for all alloys with known mechanical and deformation properties have been obtained. The relative concentrated force in the truss's ridge node on the relative vertical deformations dependences graphs are plotted, taking into account the geometric and physical nonlinear material operation. The conducted research practical significance is that the obtained dependencies allow modeling the MT trusses with aluminum-based rods operation, taking into account various truss geometries. When modeling trusses, an inclined load and the presence of elastic supports in the ridge node were taken into account. Dependencies make it possible to predict the aluminum ribbed-ring domes stability loss, which are modeled by MT trusses. Розглядаються робота купольних конструкцій великих прольотів зі сплавів алюмінію. Вибір матеріалу елементів куполу обумовлений меншою вагою у порівнянні зі сталевими елементами, корозійною стійкістю матеріалу, меншим коефіцієнтом теплового розширення.Проведено аналіз існуючих наукових досліджень пов’язаних із проблемою втрати стійкості конструкцій, що виготовлено з алюмінію або алюмінієвих сплавів. Досліджена проблема втрати стійкості конструкцій ребристо-кільцевих куполів виконаних з алюмінієвих сплавів. У якості моделі дослідження використано двострижневу тришарнірну модель — ферму фон-Мізеса (ФМ). Отримано графіки залежностей нормальних напружень від відносних деформацій для положистої ферми з кутами нахилу стрижнів — 80 та 85 градусів від вертикалі для сплаву алюмінію 5083, різних за товщиною трубчастих профілів. Дослідження виконувались відповідно до положень, що описані в ДСТУ-Н Б EN 1999. Виведено систему аналітичних виразів для визначення модуля пружності алюмінієвого сплаву на діаграмах розтяту. Отримано аналітичні залежності, що описують роботу ферм ФМ з алюмінію для всіх сплавів, для яких відомі механічні та деформаційні властивості. Побудовано графіки залежностей відносної зосередженої сили в гребеневому вузлу ферми від відносних вертикальних деформацій з урахуванням геометричної та фізичної нелінійної роботи матеріалу. Практична значимість проведених досліджень полягає в тому, що отримані залежності дозволяють моделювати роботу ферм ФМ зі стрижнями на основі алюмінію із урахуванням різноманітної геометрії ферми. При моделювання ферм враховується наявність похилого навантаження та присутність пружних опор в гребеневому вузлу. Залежності дозволяють прогнозувати втрату стійкості алюмінієвих ребристо–кільцевих куполів, які моделюються фермами ФМ.
- Open Access
- 24 November 2023
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 111,p. 113-124
Safety assessment of the steel structures of nuclear power plants units considering special operation conditions
Special operation conditions of steel structures nuclear power plants units (elevated temperature of the surrounding environment, the need to consider the simultaneous action of several episodic impacts etc.) require using of special approaches to their safety assessment. Among the wide variety of steel structures at nuclear power plantsunits, the supporting structures of equipment and pipelines play an essential role in ensuring its safety. At the same time, state building codes oriented towards traditional steel structures that are subjected to standard loads and impacts, and do not consider mensioned special operating conditions. Regulatory acts on nuclear and radiation safety in this aspect contain general regulatory requirements, which is due to the modern concept of the development of the regulatory-legal framework of Ukraine for ensuring the safety of nuclear plants. Therefore, the existing regulatory and methodological support does not sufficiently cover the aspects of safety assessment of supporting structures, taking into account the special operation conditions. The article proposes approaches to assessing the safety of equipment and pipelines supporting structures nuclear power plants units, which consider both the special operation conditions and the degree of responsibility for ensuring safety during and after seismic hazards.
- 24 November 2023
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 111,p. 113-124
Open AccessSafety assessment of the steel structures of nuclear power plants units considering special operation conditions
Special operation conditions of steel structures nuclear power plants units (elevated temperature of the surrounding environment, the need to consider the simultaneous action of several episodic impacts etc.) require using of special approaches to their safety assessment. Among the wide variety of steel structures at nuclear power plantsunits, the supporting structures of equipment and pipelines play an essential role in ensuring its safety. At the same time, state building codes oriented towards traditional steel structures that are subjected to standard loads and impacts, and do not consider mensioned special operating conditions. Regulatory acts on nuclear and radiation safety in this aspect contain general regulatory requirements, which is due to the modern concept of the development of the regulatory-legal framework of Ukraine for ensuring the safety of nuclear plants. Therefore, the existing regulatory and methodological support does not sufficiently cover the aspects of safety assessment of supporting structures, taking into account the special operation conditions. The article proposes approaches to assessing the safety of equipment and pipelines supporting structures nuclear power plants units, which consider both the special operation conditions and the degree of responsibility for ensuring safety during and after seismic hazards.