  • Open Access

    A Parallel Accumulation-Mobility Aligned Fragmentation Strategy Utilizing High-Resolution Ion Mobility for High Performance Proteomics Analysis

    by Leonard C. Rorrer, Liulin Deng, Lauren Royer, Isabel Uribe, Benjamin C. Orsburn, Oliver Bernhardt, Tejas Gandhi, Lukas Reiter, Daniel DeBord


  • Open Access

    xTracer: Integrating chromatogram and mobiligram correlations for untargeted peptide identification in SLIM-based PAMAF data

    by Jian Song, Liulin Deng, Lauren Royer, Bennett Kalafut, Daniel DeBord, Jesse G. Meyer

    Parallel Accumulation with Mobility-Aligned Fragmentation (PAMAF) achieves near-complete ion utilization and high spectral specificity by fragmenting all mobility-separated precursors without quadrupole isolation. Leveraging the ultrahigh mobility resolution of SLIM, this quadrupole-free strategy maximizes ion utilization efficiency and offers a promising approach in mass spectrometry–based proteomics, particularly for low-abundance peptides or low-input samples. However, the unique data structure of PAMAF where precursor–fragment relationships are encoded along the mobility dimension renders it incompatible with existing peptide identification tools. Here, we present xTracer, the first untargeted peptide identification algorithm developed specifically for PAMAF data. xTracer integrates correlations across both chromatographic and mobility dimensions to associate precursor and fragment ions, reconstruct pseudo-spectra, and enable database searching using well-established DDA search engines. Applied to datasets with varying sample loads and acquisition throughputs, xTracer consistently achieved robust and reproducible peptide identifications, outperforming single-domain correlation strategies. Overall, xTracer provides a versatile and high-efficiency computational framework for reconstructing pseudo-spectra from quadrupole-free, mobility-aligned fragmentation data, enhancing the analytical power of high-resolution ion mobility (HRIM)–based proteomics.

  • Open Access

    A Parallel Accumulation-Mobility Aligned Fragmentation Strategy Utilizing High-Resolution Ion Mobility for High Performance Proteomics Analysis

    by Leonard C. Rorrer, Liulin Deng, Lauren Royer, Isabel Uribe, Benjamin C. Orsburn, Oliver Bernhardt, Tejas Gandhi, Lukas Reiter, Daniel DeBord

    Here we present a novel data independent acquisition (DIA) mass spectrometry (MS) operating mode termed parallel accumulation-mobility aligned fragmentation (PAMAF) that offers enhanced speed and sensitivity of ion fragmentation analysis for nontargeted discovery workflows such as bottom-up proteomics. This mode of operation leverages high-resolution ion mobility (HRIM) separation capabilities of the structures for lossless ion manipulation (SLIM) technology to achieve HRIM-based precursor isolation in place of traditional quadrupole filtering approaches. This PAMAF mode of operation increases the number of features that can be identified per MS1/MS2 acquisition cycle by employing mobility-based time alignment to associate fragment ions with their corresponding precursor ions. By using a high-speed, lossless separation technique for precursor isolation instead of the comparatively slow and wasteful quadrupole filtering method, we can avoid ion losses up to 99% while simultaneously increasing the rate at which precursor ions are sequentially fragmented and detected. Additionally, by storing ions in a trapping region while the previous packet of ions is being analyzed, the PAMAF mode achieves ∼100% ion utilization efficiency. Benchmarking results of LC-PAMAF-MS analysis of a whole cell protein digest showed approximately 6x more protein group identifications compared to a standard data-dependent acquisition (DDA) analysis without HRIM on the same QTOF instrument, and to over 100x improvement for low-load workflows. Quantitative evaluations demonstrated that PAMAF mode could quantify low abundance peptides, including those undetectable by DDA. Additionally, since precursor isolation in PAMAF mode is size-based rather than m/z -based, many coeluting isobars and isomers can be resolved prior to fragmentation to eliminate chimeric spectra that compromise identification accuracy. In this work we also explored the benefits of combining HRIM and quadrupole isolation to achieve improved specificity. This approach, known as DIA-PAMAF mode, further reduces the frequency of chimeric fragmentation spectra, and enabled the detection of over 8,000 protein groups from a HeLa digest analysis. PAMAF mode brings a powerful new technique to the field of proteomics that has the potential to improve the sensitivity and selectivity of mass spectrometry-based proteomics.

  • Open Access

    High‐Resolution Ion Mobility as an Alternative to Quadrupole‐Based Precursor Isolation for Reducing Chimeric Fragmentation Spectra in Bottom‐Up Proteomics

    by Isabel R. Uribe, Liulin Deng, Leonard Rorrer, Lauren Royer, Miriam Fico, Daniel DeBord

    To assess the potential for high resolution ion mobility (HRIM) as an alternative means of precursor isolation for mass spectrometry fragmentation analysis we performed a meta‐analysis of predicted tryptic peptide features from the human proteome to measure the rate of chimeric spectrum generation relative to traditional quadrupole‐based isolation. Results indicate that for proteomic mixtures, HRIM separation with a peak capacity of 100 produces chimeric spectra at a rate commensurate with a ∼5 Th quadrupole isolation window, while providing the additional benefit of generating non‐chimeric spectra for many isobaric and isomeric peptides unresolvable with a quadrupole filter. This behavior was verified experimentally using a HRIM‐QTOF mass spectrometry system. The ability to combine HRIM and MS isolation resulted in >10× increase in precursor isolation specificity as compared to either of the techniques independently.


  • Open Access

    Novel high-resolution ion mobility mass spectrometry for site-specific quantification of the sirtuin-5 regulated kidney succinylome

    by Birgit Schilling, Leonard Rorrer, Lauren Royer, Anne Silva-Barbosa, Katherine Pfister, Eric Goetzman, Sunder Sims-Lucas, Daniel DeBord, Joanna Bons

    Protein post-translational modifications (PTMs) dynamically regulate essential biological and cellular processes. Lysine succinylation changes the amino acid charge, potentially affecting protein structures and functions, and dysregulation of protein succinylation may lead to metabolic disorders. Proteome-wide succinylation quantification using proteomic tools remains challenging, especially due to the low abundance of succinylated peptides and the frequent presence of isomeric PTM forms. Ion mobility spectrometry workflows that can differentiate peptidoforms with different PTM distributions represent a powerful strategy to alleviate these challenges. Recently, a new Parallel Accumulation with Mobility Aligned Fragmentation (PAMAF™) operating mode for high-resolution ion mobility-mass spectrometry (HRIM-MS) analysis based on the structures for lossless ion manipulation (SLIM) technology was introduced. Here, we first assessed the performance of PAMAF mode for protein succinylation analysis using synthetic succinylated peptides, demonstrating residue-level differentiation of co-eluting isomers and isobars and precise PTM site localization. We leveraged this novel approach to investigate succinylome remodeling in kidney tissues from wild-type and Sirtuin-5 (Sirt5) knock-out mice, a NAD + -dependent lysine de-succinylase. PAMAF acquisitions yielded ∼1,000 confidently identified and accurately quantified succinylated peptides and sites from mouse kidney. Sirt5 regulated succinylation of mitochondrial proteins involved in metabolic processes, including fatty acid oxidation, the tricarboxylic acid cycle, and propionate metabolism.


  • Open Access

    High-resolution ion mobility as an alternative to quadrupole-based precursor isolation for reducing chimeric fragmentation spectra in bottom-up proteomics

    by Isabel Uribe, Liulin Deng, Leonard Rorrer Iii, Lauren Royer, Miriam Fico, Daniel DeBord

    To assess the potential for high resolution ion mobility (HRIM) as an alternative means of precursor isolation for mass spectrometry fragmentation analysis we performed a meta-analysis of predicted tryptic peptide features from the human proteome to measure the rate of chimeric spectrum generation relative to traditional quadrupole-based isolation. Results indicate that for proteomic mixtures, HRIM separation with a peak capacity of 100 produces chimeric spectra at a rate commensurate with a ~5 Th quadrupole isolation window, while providing the additional benefit of generating non-chimeric spectra for many isobaric and isomeric peptides unresolvable with a quadrupole filter. This behavior was verified experimentally using a HRIM-QTOF mass spectrometry system. The ability to combine HRIM and MS isolation resulted in >10x increase in precursor isolation specificity as compared to either of the techniques independently.


  • Open Access

    Abandoning the Quadrupole for Mass Spectrometry Fragmentation Analysis: Towards 1,000 Hz Speeds with 100% Ion Utilization Using High Resolution Ion Mobility Precursor Isolation

    by Daniel DeBord, Leonard C. Rorrer, Liulin Deng, Frederick G. Strathmann

    In today’s fast-evolving landscape of omics research, tandem mass spectrometry has become a cornerstone for uncovering the complexities of biological systems. Yet, despite its essential role, the technology remains bound by the inherent limitations of quadrupole filters, which throw away up to 99% of the useful ion signal and caps the speed at which fragmentation data can be generated. These deficiencies often force compromises in data depth and accuracy, hindering breakthroughs that tie genomics, proteomics, and metabolomics together. A new technology is poised to break through these performance barriers, unlocking unprecedented capabilities in precision, sensitivity and throughput. This step-change in how mass spectrometry fragmentation analysis is performed will reshape the future of scientific discovery, pushing the boundaries of what’s possible. The solution is high resolution ion mobility (HRIM), which offers a means to quickly and efficiently isolate ions prior to fragmentation and detection by a high resolution mass spectrometer (HRMS) while also resolving challenging isomeric and isobaric compounds that lead to chimeric MS/MS spectra. HRIM isolates ions in time as a result of a high speed separation rather than acting as a filter that discards ion signal like the pervasive quadrupole mass analyzer, allowing higher sensitivity analysis to be achieved. Also, since HRIM eliminates the need to hop or sweep electronics control parameters, as is the case with a quadrupole, fragmentation spectral generation can occur at a much faster rate, upwards of 500 Hz. This whitepaper describes an IM/MS methodology first contemplated over twenty years ago and today being positioned as the fastest method for high resolution fragmentation analysis. Revisiting this concept using the latest generation ion mobility technology based on structures for lossless ion manipulation (SLIM), which is the only HRIM technology that delivers similar resolution and range of analysis as a quadrupole, realizes the full potential of this approach to deliver benefits in both speed and sensitivity for high performance MS/MS measurements. This new way of achieving ion fragmentation in complex samples is set to revolutionize the mass spectrometry space, starting in the growing field of proteomics where all researchers are seeking faster methods to achieve more comprehensive proteomic coverage. Due to the advantages of HRIM physics, we predict this will set the bar for high throughput -omics within the coming years and will eventually be as ubiquitous as the quadrupole is today.


  • Open Access

    Implementation of Intact Protein MS on Commercial SLIM Instrumentation using nano-, micro-, and high- flow ionization sources and applications to disease associated proteoforms and intact antibodies

    by Md Amin Hossain, Tom Doherty, Jennifer Krone, Daniel DeBord, Luis Viskatis, Jared R. Auclair, Thais Pedrete, Fanny Liu, Christian Bleiholder, Jeff Agar

    This study addresses three unmet needs: 1) development of widely accessible native mass spectrometry (MS) methods and 2) native top-down mass spectrometry (TDMS) methods for high flow sources on an Agilent Q-TOF mass spectrometer, and 3) confirming suitability of structures for lossless ion manipulation (SLIM) ion mobility (IM) MS methods for analysis of native intact proteins. To decrease the cost and training barrier to performing MS, TDMS, and IM-MS analysis of native proteins, we have developed methods for nanospray, microspray, and heated high flow electrospray ionization sources. SLIM offers the highest full-scan IM resolution available, but commercial instrumentation has not previously been applied to native MS. Our optimized methods extend the upper m/z limit beyond the manufacturer’s default IM mode upper mass limit of 4000 m/z to 7000 m/z, which allows for intact protein and native MS analysis of a variety of proteins, including native MS of intact IgG antibodies. Using the robust and facile Agilent Jet Spray (AJS) source, we demonstrate the application of native protein MS to amyotrophic lateral sclerosis (ALS)-associated Cu/Zn-superoxide dismutase proteoforms, characterizing a novel conformer and quaternary structural changes.

  • Investigating Performance of the SLIM-Based High Resolution Ion Mobility Platform for Separation of Isomeric Phosphatidylcholine Species

    by Komal Kedia, Rachel Harris, Kim Ekroos, Kelly W Moser, Daniel DeBord, Paolo Tiberi, Laura Goracci, Nanyan Rena Zhang, Weixun Wang, Daniel S. Spellman, et al.

    Lipids are structurally diverse molecules that play a pivotal role in a plethora of biological processes. However, deciphering the biological roles of the specific lipids is challenging due to the existence of numerous isomers. This high chemical complexity of the lipidome is one of the major challenges in lipidomics research, as the traditional liquid chromatography-mass spectrometry (LC-MS) based approaches are often not powerful enough to resolve these isomeric and isobaric nuances within complex samples. Thus, lipids are uniquely suited to the benefits provided by multidimensional liquid chromatography-ion mobility-mass spectrometry (LC-IM-MS) analysis. However, many forms of lipid isomerism, including double-bond positional isomers and regioisomers, are structurally similar such that their collision cross section (CCS) differences are unresolvable via conventional IM approaches. Here we evaluate the performance of a high resolution ion mobility (HRIM) system based on structures for lossless ion manipulation (SLIM) technology interfaced to a high resolution quadrupole time-of-flight (QTOF) analyzer to address the noted lipidomic isomerism challenge. SLIM implements the traveling wave ion mobility technique along an ∼13 m ion path, providing longer path lengths to enable improved separation of isomeric features. We demonstrate the power of HRIM-MS to dissect isomeric PC standards differing only in double bond (DB) and stereospecific number (SN) positions. The partial separation of protonated DB isomers is significantly enhanced when they are analyzed as metal adducts. For sodium adducts, we achieve close to baseline separation of three different PC 18:1/18:1 isomers with different cis-double bond locations. Similarly, PC 18:1/18:1 (cis-9) can be resolved from the corresponding PC 18:1/18:1 (trans-9) form. The separation capacity is further enhanced when using silver ion doping, enabling the baseline separation of regioisomers that cannot be resolved when measured as sodium adducts. The sensitivity and reproducibility of the approach were assessed, and the performance for more complex mixtures was benchmarked by identifying PC isomers in total brain and liver lipid extracts.


  • High-defined quantitative snapshots of the ganglioside lipidome using high resolution ion mobility SLIM assisted shotgun lipidomics

    by Kelly L. Wormwood Moser, Gregory Van Aken, Daniel DeBord, Nathan Galen Hatcher, Laura Maxon, Melissa Sherman, Lihang Yao, Kim Ekroos