Liulin Deng
Research Subjects
Liulin Deng has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Daniel DeBord
MOBILion Systems, Inc.
5 shared publications- Daniel DeBord
MOBILion Systems, Inc. 4 Hillman Drive, Suite 130, Chadds Ford, PA 19317, United States
4 shared publications - Leonard C. Rorrer
MOBILion Systems, Inc. 4 Hillman Drive, Suite 130, Chadds Ford, PA 19317, United States
3 shared publications Bennett Kalafut
MOBILion Systems, Inc.
2 shared publications- Isabel Uribe
MOBILion Systems, Inc. 4 Hillman Drive, Suite 130, Chadds Ford, PA 19317, United States
2 shared publications - Jian Song
Cedars-Sinai Medical Center
2 shared publications
Latest Publications
- 9 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (44) , 30080-30090
xTracer: Integrating Chromatogram and Mobilogram Correlations for Untargeted Peptide Identification in SLIM-Based PAMAF Data
Parallel accumulation with mobility-aligned fragmentation (PAMAF) achieves near-complete ion utilization and high spectral specificity by fragmenting all mobility-separated precursors without quadrupole isolation. Leveraging the ultrahigh mobility resolution of SLIM, this quadrupole-free strategy maximizes ion utilization efficiency and offers a promising approach in mass spectrometry-based proteomics, particularly for low-abundance peptides or low-input samples. However, the unique data structure of PAMAF, where precursor−fragment relationships are encoded along the mobility dimension, is not ideally suited to many existing peptide identification tools. Here, we present xTracer, an untargeted peptide identification algorithm developed specifically for PAMAF data. xTracer integrates correlations across both chromatographic and mobility dimensions to associate precursor and fragment ions, reconstruct pseudo-spectra, and enable database searching using well-established DDA search engines. Applied to datasets with varying sample loads and acquisition throughputs, xTracer consistently achieved robust and reproducible peptide identifications, outperforming both single-domain correlation strategies and diaTracer, which was developed for diaPASEF data. Overall, xTracer provides a versatile and high-efficiency computational framework for reconstructing pseudo-spectra from quadrupole-free, mobility-aligned fragmentation data, enhancing the analytical power of high-resolution ion mobility-based proteomics.
- 9 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (44) , 30080-30090
xTracer: Integrating Chromatogram and Mobilogram Correlations for Untargeted Peptide Identification in SLIM-Based PAMAF Data
Parallel accumulation with mobility-aligned fragmentation (PAMAF) achieves near-complete ion utilization and high spectral specificity by fragmenting all mobility-separated precursors without quadrupole isolation. Leveraging the ultrahigh mobility resolution of SLIM, this quadrupole-free strategy maximizes ion utilization efficiency and offers a promising approach in mass spectrometry-based proteomics, particularly for low-abundance peptides or low-input samples. However, the unique data structure of PAMAF, where precursor−fragment relationships are encoded along the mobility dimension, is not ideally suited to many existing peptide identification tools. Here, we present xTracer, an untargeted peptide identification algorithm developed specifically for PAMAF data. xTracer integrates correlations across both chromatographic and mobility dimensions to associate precursor and fragment ions, reconstruct pseudo-spectra, and enable database searching using well-established DDA search engines. Applied to datasets with varying sample loads and acquisition throughputs, xTracer consistently achieved robust and reproducible peptide identifications, outperforming both single-domain correlation strategies and diaTracer, which was developed for diaPASEF data. Overall, xTracer provides a versatile and high-efficiency computational framework for reconstructing pseudo-spectra from quadrupole-free, mobility-aligned fragmentation data, enhancing the analytical power of high-resolution ion mobility-based proteomics.
- Open Access
xTracer: Integrating chromatogram and mobiligram correlations for untargeted peptide identification in SLIM-based PAMAF data
Parallel Accumulation with Mobility-Aligned Fragmentation (PAMAF) achieves near-complete ion utilization and high spectral specificity by fragmenting all mobility-separated precursors without quadrupole isolation. Leveraging the ultrahigh mobility resolution of SLIM, this quadrupole-free strategy maximizes ion utilization efficiency and offers a promising approach in mass spectrometry–based proteomics, particularly for low-abundance peptides or low-input samples. However, the unique data structure of PAMAF where precursor–fragment relationships are encoded along the mobility dimension renders it incompatible with existing peptide identification tools. Here, we present xTracer, the first untargeted peptide identification algorithm developed specifically for PAMAF data. xTracer integrates correlations across both chromatographic and mobility dimensions to associate precursor and fragment ions, reconstruct pseudo-spectra, and enable database searching using well-established DDA search engines. Applied to datasets with varying sample loads and acquisition throughputs, xTracer consistently achieved robust and reproducible peptide identifications, outperforming single-domain correlation strategies. Overall, xTracer provides a versatile and high-efficiency computational framework for reconstructing pseudo-spectra from quadrupole-free, mobility-aligned fragmentation data, enhancing the analytical power of high-resolution ion mobility (HRIM)–based proteomics.
Open AccessxTracer: Integrating chromatogram and mobiligram correlations for untargeted peptide identification in SLIM-based PAMAF data
Parallel Accumulation with Mobility-Aligned Fragmentation (PAMAF) achieves near-complete ion utilization and high spectral specificity by fragmenting all mobility-separated precursors without quadrupole isolation. Leveraging the ultrahigh mobility resolution of SLIM, this quadrupole-free strategy maximizes ion utilization efficiency and offers a promising approach in mass spectrometry–based proteomics, particularly for low-abundance peptides or low-input samples. However, the unique data structure of PAMAF where precursor–fragment relationships are encoded along the mobility dimension renders it incompatible with existing peptide identification tools. Here, we present xTracer, the first untargeted peptide identification algorithm developed specifically for PAMAF data. xTracer integrates correlations across both chromatographic and mobility dimensions to associate precursor and fragment ions, reconstruct pseudo-spectra, and enable database searching using well-established DDA search engines. Applied to datasets with varying sample loads and acquisition throughputs, xTracer consistently achieved robust and reproducible peptide identifications, outperforming single-domain correlation strategies. Overall, xTracer provides a versatile and high-efficiency computational framework for reconstructing pseudo-spectra from quadrupole-free, mobility-aligned fragmentation data, enhancing the analytical power of high-resolution ion mobility (HRIM)–based proteomics.
- Open Access
A Parallel Accumulation-Mobility Aligned Fragmentation Strategy Utilizing High-Resolution Ion Mobility for High Performance Proteomics Analysis
Here we present a novel data independent acquisition (DIA) mass spectrometry (MS) operating mode termed parallel accumulation-mobility aligned fragmentation (PAMAF) that offers enhanced speed and sensitivity of ion fragmentation analysis for nontargeted discovery workflows such as bottom-up proteomics. This mode of operation leverages high-resolution ion mobility (HRIM) separation capabilities of the structures for lossless ion manipulation (SLIM) technology to achieve HRIM-based precursor isolation in place of traditional quadrupole filtering approaches. This PAMAF mode of operation increases the number of features that can be identified per MS1/MS2 acquisition cycle by employing mobility-based time alignment to associate fragment ions with their corresponding precursor ions. By using a high-speed, lossless separation technique for precursor isolation instead of the comparatively slow and wasteful quadrupole filtering method, we can avoid ion losses up to 99% while simultaneously increasing the rate at which precursor ions are sequentially fragmented and detected. Additionally, by storing ions in a trapping region while the previous packet of ions is being analyzed, the PAMAF mode achieves ∼100% ion utilization efficiency. Benchmarking results of LC-PAMAF-MS analysis of a whole cell protein digest showed approximately 6x more protein group identifications compared to a standard data-dependent acquisition (DDA) analysis without HRIM on the same QTOF instrument, and to over 100x improvement for low-load workflows. Quantitative evaluations demonstrated that PAMAF mode could quantify low abundance peptides, including those undetectable by DDA. Additionally, since precursor isolation in PAMAF mode is size-based rather than m/z -based, many coeluting isobars and isomers can be resolved prior to fragmentation to eliminate chimeric spectra that compromise identification accuracy. In this work we also explored the benefits of combining HRIM and quadrupole isolation to achieve improved specificity. This approach, known as DIA-PAMAF mode, further reduces the frequency of chimeric fragmentation spectra, and enabled the detection of over 8,000 protein groups from a HeLa digest analysis. PAMAF mode brings a powerful new technique to the field of proteomics that has the potential to improve the sensitivity and selectivity of mass spectrometry-based proteomics.
Open AccessA Parallel Accumulation-Mobility Aligned Fragmentation Strategy Utilizing High-Resolution Ion Mobility for High Performance Proteomics Analysis
Here we present a novel data independent acquisition (DIA) mass spectrometry (MS) operating mode termed parallel accumulation-mobility aligned fragmentation (PAMAF) that offers enhanced speed and sensitivity of ion fragmentation analysis for nontargeted discovery workflows such as bottom-up proteomics. This mode of operation leverages high-resolution ion mobility (HRIM) separation capabilities of the structures for lossless ion manipulation (SLIM) technology to achieve HRIM-based precursor isolation in place of traditional quadrupole filtering approaches. This PAMAF mode of operation increases the number of features that can be identified per MS1/MS2 acquisition cycle by employing mobility-based time alignment to associate fragment ions with their corresponding precursor ions. By using a high-speed, lossless separation technique for precursor isolation instead of the comparatively slow and wasteful quadrupole filtering method, we can avoid ion losses up to 99% while simultaneously increasing the rate at which precursor ions are sequentially fragmented and detected. Additionally, by storing ions in a trapping region while the previous packet of ions is being analyzed, the PAMAF mode achieves ∼100% ion utilization efficiency. Benchmarking results of LC-PAMAF-MS analysis of a whole cell protein digest showed approximately 6x more protein group identifications compared to a standard data-dependent acquisition (DDA) analysis without HRIM on the same QTOF instrument, and to over 100x improvement for low-load workflows. Quantitative evaluations demonstrated that PAMAF mode could quantify low abundance peptides, including those undetectable by DDA. Additionally, since precursor isolation in PAMAF mode is size-based rather than m/z -based, many coeluting isobars and isomers can be resolved prior to fragmentation to eliminate chimeric spectra that compromise identification accuracy. In this work we also explored the benefits of combining HRIM and quadrupole isolation to achieve improved specificity. This approach, known as DIA-PAMAF mode, further reduces the frequency of chimeric fragmentation spectra, and enabled the detection of over 8,000 protein groups from a HeLa digest analysis. PAMAF mode brings a powerful new technique to the field of proteomics that has the potential to improve the sensitivity and selectivity of mass spectrometry-based proteomics.
- Open Access
- 5 December 2025
- Published by Wiley in Proteomics
- Vol. 26 (4) , 36-48
High‐Resolution Ion Mobility as an Alternative to Quadrupole‐Based Precursor Isolation for Reducing Chimeric Fragmentation Spectra in Bottom‐Up Proteomics
To assess the potential for high resolution ion mobility (HRIM) as an alternative means of precursor isolation for mass spectrometry fragmentation analysis we performed a meta‐analysis of predicted tryptic peptide features from the human proteome to measure the rate of chimeric spectrum generation relative to traditional quadrupole‐based isolation. Results indicate that for proteomic mixtures, HRIM separation with a peak capacity of 100 produces chimeric spectra at a rate commensurate with a ∼5 Th quadrupole isolation window, while providing the additional benefit of generating non‐chimeric spectra for many isobaric and isomeric peptides unresolvable with a quadrupole filter. This behavior was verified experimentally using a HRIM‐QTOF mass spectrometry system. The ability to combine HRIM and MS isolation resulted in >10× increase in precursor isolation specificity as compared to either of the techniques independently.
- 5 December 2025
- Published by Wiley in Proteomics
- Vol. 26 (4) , 36-48
Open AccessHigh‐Resolution Ion Mobility as an Alternative to Quadrupole‐Based Precursor Isolation for Reducing Chimeric Fragmentation Spectra in Bottom‐Up Proteomics
To assess the potential for high resolution ion mobility (HRIM) as an alternative means of precursor isolation for mass spectrometry fragmentation analysis we performed a meta‐analysis of predicted tryptic peptide features from the human proteome to measure the rate of chimeric spectrum generation relative to traditional quadrupole‐based isolation. Results indicate that for proteomic mixtures, HRIM separation with a peak capacity of 100 produces chimeric spectra at a rate commensurate with a ∼5 Th quadrupole isolation window, while providing the additional benefit of generating non‐chimeric spectra for many isobaric and isomeric peptides unresolvable with a quadrupole filter. This behavior was verified experimentally using a HRIM‐QTOF mass spectrometry system. The ability to combine HRIM and MS isolation resulted in >10× increase in precursor isolation specificity as compared to either of the techniques independently.
- 19 October 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (11) , 2578-2585
Iterative SLIM (itSLIM) for Ultrahigh Resolution Targeted Ion Mobility Analysis
We present a novel approach for achieving ultrahigh-resolution ion mobility (UHRIM) separations using a structures for lossless ion manipulation (SLIM) ion mobility-mass spectrometry (IM-MS) system. By incorporating a rounded-turn ion path design, ions can be transmitted and separated bidirectionally, enabling an iterative workflow in which mobility-separated ions are returned to the entrance of the serpentine path while preserving their separation order and position. This "iterative SLIM" (itSLIM) process can be repeated multiple times with little to no target ion loss to increase the effective path length of the mobility separation. As IM resolution scales with the square root of the separation path length, this method enhances IM resolution without increasing the form factor of the mobility device. It is particularly beneficial for targeted mobility analysis and confident identification where high specificity is required. UHRIM separation was achieved with a two-peak resolution of 2.48 for 18:1 Δ9-cis- and Δ9-trans-phosphatidylethanolamine (PE) lipid isomers at a path length of 120 m. By combining itSLIM separation over a 90-m path with MS/MS fragmentation analysis, a liquid chromatography (LC)-free workflow capable of definitive identification of the isomeric small molecule drugs norcodeine and norhydrocodone was achieved. The UHRIM separation simplifies the resulting MS/MS spectra and improves identification accuracy. Such capabilities are anticipated to enhance the throughput by reducing or eliminating LC run times and robustness of screening workflows. Iterative SLIM provides a powerful strategy for enhancing IM resolution, offering broad utility for high-performance analytical separations.
- 19 October 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (11) , 2578-2585
Iterative SLIM (itSLIM) for Ultrahigh Resolution Targeted Ion Mobility Analysis
We present a novel approach for achieving ultrahigh-resolution ion mobility (UHRIM) separations using a structures for lossless ion manipulation (SLIM) ion mobility-mass spectrometry (IM-MS) system. By incorporating a rounded-turn ion path design, ions can be transmitted and separated bidirectionally, enabling an iterative workflow in which mobility-separated ions are returned to the entrance of the serpentine path while preserving their separation order and position. This "iterative SLIM" (itSLIM) process can be repeated multiple times with little to no target ion loss to increase the effective path length of the mobility separation. As IM resolution scales with the square root of the separation path length, this method enhances IM resolution without increasing the form factor of the mobility device. It is particularly beneficial for targeted mobility analysis and confident identification where high specificity is required. UHRIM separation was achieved with a two-peak resolution of 2.48 for 18:1 Δ9-cis- and Δ9-trans-phosphatidylethanolamine (PE) lipid isomers at a path length of 120 m. By combining itSLIM separation over a 90-m path with MS/MS fragmentation analysis, a liquid chromatography (LC)-free workflow capable of definitive identification of the isomeric small molecule drugs norcodeine and norhydrocodone was achieved. The UHRIM separation simplifies the resulting MS/MS spectra and improves identification accuracy. Such capabilities are anticipated to enhance the throughput by reducing or eliminating LC run times and robustness of screening workflows. Iterative SLIM provides a powerful strategy for enhancing IM resolution, offering broad utility for high-performance analytical separations.
- 11 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (24) , 12613-12622
Enhancing Sensitivity in Low-Load Proteomics Orbitrap Workflows via SLIM Integration
A Structures for Lossless Ion Manipulation-Orbitrap Exploris 480 (SLIM-OE) ion mobility mass spectrometry (IM-MS) platform was developed, integrating SLIM IM separation with Orbitrap MS analysis. A "staggered IMS" mode was designed to acquire IM-m/z two-dimensional heatmap data via direct infusion for method development, and an LC compatible SLIM-enabled data-independent acquisition (SLIM-DIA) workflow was implemented for low sample load proteomics analysis. The study evaluated IM separation across a broad m/z range of ions and demonstrated up to a 190× sensitivity enhancement in both IM-MS and IM-MS/MS modes of operation relative to operation in MS and MS/MS modes, respectively. The increased sensitivity improved protein coverage for the Qual/Quant QC Mix proteins. Compared to standard DIA, SLIM-DIA achieved a 2.3× increase in protein group identification from 2 ng of HeLa on the modified instrument, while maintaining quantitative capabilities. This research highlights the potential of the SLIM-OE IM-MS system to enhance proteomics analysis, providing a foundation for future high-performance SLIM-Orbitrap instrumentation development.
- 11 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (24) , 12613-12622
Enhancing Sensitivity in Low-Load Proteomics Orbitrap Workflows via SLIM Integration
A Structures for Lossless Ion Manipulation-Orbitrap Exploris 480 (SLIM-OE) ion mobility mass spectrometry (IM-MS) platform was developed, integrating SLIM IM separation with Orbitrap MS analysis. A "staggered IMS" mode was designed to acquire IM-m/z two-dimensional heatmap data via direct infusion for method development, and an LC compatible SLIM-enabled data-independent acquisition (SLIM-DIA) workflow was implemented for low sample load proteomics analysis. The study evaluated IM separation across a broad m/z range of ions and demonstrated up to a 190× sensitivity enhancement in both IM-MS and IM-MS/MS modes of operation relative to operation in MS and MS/MS modes, respectively. The increased sensitivity improved protein coverage for the Qual/Quant QC Mix proteins. Compared to standard DIA, SLIM-DIA achieved a 2.3× increase in protein group identification from 2 ng of HeLa on the modified instrument, while maintaining quantitative capabilities. This research highlights the potential of the SLIM-OE IM-MS system to enhance proteomics analysis, providing a foundation for future high-performance SLIM-Orbitrap instrumentation development.
- 11 December 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (51) , 20179-20188
Rounded Turn SLIM Design for High-Resolution Ion Mobility Mass Spectrometry Analysis of Small Molecules
Various rounded turn designs in Structures for Lossless Ion Manipulation (SLIM) were explored via ion trajectory simulations. The optimized design was integrated into a SLIM ion mobility (IM) system coupled with a time-of-flight (TOF) mass spectrometer (MS) for further experimental investigation. The SLIM-TOF IM-MS system was assessed for IM resolution and ion transmission efficiency across a wide m/z range using various RF frequencies and buffer gas combinations. High ion transmission efficiency and high resolution ion mobility (HRIM) separation were achieved for Agilent tune mix ions through a ∼12.8 m serpentine separation path in both nitrogen and helium. In helium, ion transmission for low m/z ions was enhanced at higher RF trapping frequency, enabling the detection of ions with m/z below 50 and all 17 amino acids from a standard mixture. Lossless ion transmission was observed for glycine (m/z 76) in both passthrough and HRIM modes. HRIM resolution was benchmarked using L-isoleucine, L-leucine, and various other isobaric and isomeric metabolites with m/z values of 60-89. This work demonstrates a rounded turn SLIM design that enables HRIM measurements for small molecule analytes, with a particular focus on metabolomics, where IM offers a means to enhance the speed, robustness, and specificity of analytical workflows.
- 11 December 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (51) , 20179-20188
Rounded Turn SLIM Design for High-Resolution Ion Mobility Mass Spectrometry Analysis of Small Molecules
Various rounded turn designs in Structures for Lossless Ion Manipulation (SLIM) were explored via ion trajectory simulations. The optimized design was integrated into a SLIM ion mobility (IM) system coupled with a time-of-flight (TOF) mass spectrometer (MS) for further experimental investigation. The SLIM-TOF IM-MS system was assessed for IM resolution and ion transmission efficiency across a wide m/z range using various RF frequencies and buffer gas combinations. High ion transmission efficiency and high resolution ion mobility (HRIM) separation were achieved for Agilent tune mix ions through a ∼12.8 m serpentine separation path in both nitrogen and helium. In helium, ion transmission for low m/z ions was enhanced at higher RF trapping frequency, enabling the detection of ions with m/z below 50 and all 17 amino acids from a standard mixture. Lossless ion transmission was observed for glycine (m/z 76) in both passthrough and HRIM modes. HRIM resolution was benchmarked using L-isoleucine, L-leucine, and various other isobaric and isomeric metabolites with m/z values of 60-89. This work demonstrates a rounded turn SLIM design that enables HRIM measurements for small molecule analytes, with a particular focus on metabolomics, where IM offers a means to enhance the speed, robustness, and specificity of analytical workflows.
- Open Access
Abandoning the Quadrupole for Mass Spectrometry Fragmentation Analysis: Towards 1,000 Hz Speeds with 100% Ion Utilization Using High Resolution Ion Mobility Precursor Isolation
In today’s fast-evolving landscape of omics research, tandem mass spectrometry has become a cornerstone for uncovering the complexities of biological systems. Yet, despite its essential role, the technology remains bound by the inherent limitations of quadrupole filters, which throw away up to 99% of the useful ion signal and caps the speed at which fragmentation data can be generated. These deficiencies often force compromises in data depth and accuracy, hindering breakthroughs that tie genomics, proteomics, and metabolomics together. A new technology is poised to break through these performance barriers, unlocking unprecedented capabilities in precision, sensitivity and throughput. This step-change in how mass spectrometry fragmentation analysis is performed will reshape the future of scientific discovery, pushing the boundaries of what’s possible. The solution is high resolution ion mobility (HRIM), which offers a means to quickly and efficiently isolate ions prior to fragmentation and detection by a high resolution mass spectrometer (HRMS) while also resolving challenging isomeric and isobaric compounds that lead to chimeric MS/MS spectra. HRIM isolates ions in time as a result of a high speed separation rather than acting as a filter that discards ion signal like the pervasive quadrupole mass analyzer, allowing higher sensitivity analysis to be achieved. Also, since HRIM eliminates the need to hop or sweep electronics control parameters, as is the case with a quadrupole, fragmentation spectral generation can occur at a much faster rate, upwards of 500 Hz. This whitepaper describes an IM/MS methodology first contemplated over twenty years ago and today being positioned as the fastest method for high resolution fragmentation analysis. Revisiting this concept using the latest generation ion mobility technology based on structures for lossless ion manipulation (SLIM), which is the only HRIM technology that delivers similar resolution and range of analysis as a quadrupole, realizes the full potential of this approach to deliver benefits in both speed and sensitivity for high performance MS/MS measurements. This new way of achieving ion fragmentation in complex samples is set to revolutionize the mass spectrometry space, starting in the growing field of proteomics where all researchers are seeking faster methods to achieve more comprehensive proteomic coverage. Due to the advantages of HRIM physics, we predict this will set the bar for high throughput -omics within the coming years and will eventually be as ubiquitous as the quadrupole is today.
Open AccessAbandoning the Quadrupole for Mass Spectrometry Fragmentation Analysis: Towards 1,000 Hz Speeds with 100% Ion Utilization Using High Resolution Ion Mobility Precursor Isolation
In today’s fast-evolving landscape of omics research, tandem mass spectrometry has become a cornerstone for uncovering the complexities of biological systems. Yet, despite its essential role, the technology remains bound by the inherent limitations of quadrupole filters, which throw away up to 99% of the useful ion signal and caps the speed at which fragmentation data can be generated. These deficiencies often force compromises in data depth and accuracy, hindering breakthroughs that tie genomics, proteomics, and metabolomics together. A new technology is poised to break through these performance barriers, unlocking unprecedented capabilities in precision, sensitivity and throughput. This step-change in how mass spectrometry fragmentation analysis is performed will reshape the future of scientific discovery, pushing the boundaries of what’s possible. The solution is high resolution ion mobility (HRIM), which offers a means to quickly and efficiently isolate ions prior to fragmentation and detection by a high resolution mass spectrometer (HRMS) while also resolving challenging isomeric and isobaric compounds that lead to chimeric MS/MS spectra. HRIM isolates ions in time as a result of a high speed separation rather than acting as a filter that discards ion signal like the pervasive quadrupole mass analyzer, allowing higher sensitivity analysis to be achieved. Also, since HRIM eliminates the need to hop or sweep electronics control parameters, as is the case with a quadrupole, fragmentation spectral generation can occur at a much faster rate, upwards of 500 Hz. This whitepaper describes an IM/MS methodology first contemplated over twenty years ago and today being positioned as the fastest method for high resolution fragmentation analysis. Revisiting this concept using the latest generation ion mobility technology based on structures for lossless ion manipulation (SLIM), which is the only HRIM technology that delivers similar resolution and range of analysis as a quadrupole, realizes the full potential of this approach to deliver benefits in both speed and sensitivity for high performance MS/MS measurements. This new way of achieving ion fragmentation in complex samples is set to revolutionize the mass spectrometry space, starting in the growing field of proteomics where all researchers are seeking faster methods to achieve more comprehensive proteomic coverage. Due to the advantages of HRIM physics, we predict this will set the bar for high throughput -omics within the coming years and will eventually be as ubiquitous as the quadrupole is today.
- Open Access
- 2 April 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (14) , 5727-5734
Masked Multiplexed Separations to Enhance Duty Cycle for Structures for Lossless Ion Manipulations
The experimental paradigm of one ion packet release per spectrum severely hinders throughput in broadband ion mobility spectrometry (IMS) systems (e.g., drift tube and traveling wave systems). Ion trapping marginally mitigates this problem, but the duty cycle deficit is amplified when moving to high resolution, long pathlength systems. As a consequence, new multiplexing strategies that maximize throughput while preserving peak fidelity are essential for high-resolution IMS separations [e.g., structures for lossless ion manipulations (SLIMs) and multi-pass technologies]. Currently, broadly applicable deconvolution strategies for Hadamard-based ion multiplexing are limited to a narrow range of modulation sequences and do not fully maximize the ion signal generated during separation across an extended path length. Compared to prior Hadamard deconvolution errors that rely upon peak picking or discrete error classification, the masked deconvolution matrix technique exploits the knowledge that Hadamard transform artifacts are reflected about the central, primary signal [i.e., the true arrival time distribution (ATD)]. By randomly inducing mathematical artifacts, it is possible to identify spectral artifacts simply by their high degree of variability relative to the core ATD. It is important to note that the deweighting approach using the masked deconvolution matrix does not make any assumptions about the underlying transform and is applicable to any multiplexing strategy employing binary sequences. In addition to demonstrating a 100-fold increase in the total number of ions detected, the effective deconvolution of data from 5, 6, 7, and 8-bit pseudo-random sequences expands the utility and efficiency of the SLIM platform.
- 2 April 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (14) , 5727-5734
Open AccessMasked Multiplexed Separations to Enhance Duty Cycle for Structures for Lossless Ion Manipulations
The experimental paradigm of one ion packet release per spectrum severely hinders throughput in broadband ion mobility spectrometry (IMS) systems (e.g., drift tube and traveling wave systems). Ion trapping marginally mitigates this problem, but the duty cycle deficit is amplified when moving to high resolution, long pathlength systems. As a consequence, new multiplexing strategies that maximize throughput while preserving peak fidelity are essential for high-resolution IMS separations [e.g., structures for lossless ion manipulations (SLIMs) and multi-pass technologies]. Currently, broadly applicable deconvolution strategies for Hadamard-based ion multiplexing are limited to a narrow range of modulation sequences and do not fully maximize the ion signal generated during separation across an extended path length. Compared to prior Hadamard deconvolution errors that rely upon peak picking or discrete error classification, the masked deconvolution matrix technique exploits the knowledge that Hadamard transform artifacts are reflected about the central, primary signal [i.e., the true arrival time distribution (ATD)]. By randomly inducing mathematical artifacts, it is possible to identify spectral artifacts simply by their high degree of variability relative to the core ATD. It is important to note that the deweighting approach using the masked deconvolution matrix does not make any assumptions about the underlying transform and is applicable to any multiplexing strategy employing binary sequences. In addition to demonstrating a 100-fold increase in the total number of ions detected, the effective deconvolution of data from 5, 6, 7, and 8-bit pseudo-random sequences expands the utility and efficiency of the SLIM platform.
- Open Access
- 18 March 2021
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 32 (4) , 1126-1137
Resolving Power and Collision Cross Section Measurement Accuracy of a Prototype High-Resolution Ion Mobility Platform Incorporating Structures for Lossless Ion Manipulation
A production prototype structures for lossless ion manipulation ion mobility (SLIM IM) platform interfaced to a commercial high-resolution mass spectrometer (MS) is described. The SLIM IM implements the traveling wave ion mobility technique across a ∼13m path length for high-resolution IM (HRIM) separations. The resolving power (CCS/ΔCCS) of the SLIM IM stage was benchmarked across various parameters (traveling wave speeds, amplitudes, and waveforms), and results indicated that resolving powers in excess of 200 can be accessed for a broad range of masses. For several cases, resolving powers greater than 300 were achieved, notably under wave conditions where ions transition from a nonselective “surfing” motion to a mobility-selective ion drift, that corresponded to ion speeds approximately 30–70% of the traveling wave speed. The separation capabilities were evaluated on a series of isomeric and isobaric compounds that cannot be resolved by MS alone, including reversed-sequence peptides (SDGRG and GRGDS), triglyceride double-bond positional isomers (TG 3, 6, 9 and TG 6, 9, 12), trisaccharides (melezitose, raffinose, isomaltotriose, and maltotriose), and ganglioside lipids (GD1b and GD1a). The SLIM IM platform resolved the corresponding isomeric mixtures, which were unresolvable using the standard resolution of a drift-tube instrument (∼50). In general, the SLIM IM-MS platform is capable of resolving peaks separated by as little as ∼0.6% without the need to target a specific separation window or drift time. Low CCS measurement biases 200), demonstrating that this instrument is well-suited for broadband HRIM separations important in global untargeted applications.
- 18 March 2021
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 32 (4) , 1126-1137
Open AccessResolving Power and Collision Cross Section Measurement Accuracy of a Prototype High-Resolution Ion Mobility Platform Incorporating Structures for Lossless Ion Manipulation
A production prototype structures for lossless ion manipulation ion mobility (SLIM IM) platform interfaced to a commercial high-resolution mass spectrometer (MS) is described. The SLIM IM implements the traveling wave ion mobility technique across a ∼13m path length for high-resolution IM (HRIM) separations. The resolving power (CCS/ΔCCS) of the SLIM IM stage was benchmarked across various parameters (traveling wave speeds, amplitudes, and waveforms), and results indicated that resolving powers in excess of 200 can be accessed for a broad range of masses. For several cases, resolving powers greater than 300 were achieved, notably under wave conditions where ions transition from a nonselective “surfing” motion to a mobility-selective ion drift, that corresponded to ion speeds approximately 30–70% of the traveling wave speed. The separation capabilities were evaluated on a series of isomeric and isobaric compounds that cannot be resolved by MS alone, including reversed-sequence peptides (SDGRG and GRGDS), triglyceride double-bond positional isomers (TG 3, 6, 9 and TG 6, 9, 12), trisaccharides (melezitose, raffinose, isomaltotriose, and maltotriose), and ganglioside lipids (GD1b and GD1a). The SLIM IM platform resolved the corresponding isomeric mixtures, which were unresolvable using the standard resolution of a drift-tube instrument (∼50). In general, the SLIM IM-MS platform is capable of resolving peaks separated by as little as ∼0.6% without the need to target a specific separation window or drift time. Low CCS measurement biases 200), demonstrating that this instrument is well-suited for broadband HRIM separations important in global untargeted applications.