Fabien Jaulmes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Fabien Jaulmes has a total of 341 co-authors. Here are the top co-authors by number of shared publications:
- Michael Komm
Institute of Plasma Physics of the CAS
9 shared publications - Andrea Casolari
Ústav fyziky plazmatu Akademie věd České republiky
5 shared publications - David Tskhakaya
Institute of Plasma Physics of the Czech Academy of Sciences, U Slovanky 2525/1a, 18200 Prague, Czech Republic
5 shared publications - Klara Bogar
Institute of Plasma Physics of the Czech Academy of Sciences, Za Slovankou 1782/3, 18200 Prague, Czech Republic
5 shared publications - Lukas Kripner
Institute of Plasma Physics of the Czech Academy of Sciences
5 shared publications - Martin Hron
Czech Academy of Sciences - Institute of Plasma Physics Prague, CZECH REPUBLIC
5 shared publications
Latest Publications
- Open Access
- 4 November 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
First transport study of Li and Sn for COMPASS Upgrade tokamak
One of the principal research objectives of the COMPASS Upgrade (COMPASS-U) tokamak under construction in Prague is the investigation of reliable long-term plasma power exhaust solutions for future fusion reactors. Owing to its unique operational parameters, including magnetic field of 5 T, plasma current of 2 MA, divertor plasma densities exceeding 10 21 m -3 , and a tungsten first wall, COMPASS-U is expected to generate divertor surface-normal heat fluxes of several tens of MW/m 2 , relevant to future DEMO-class reactors, in 1–10 s discharges. Prototype liquid metal (LM) divertor tiles based on lithium (Li), tin (Sn), and their alloys will be experimentally tested. To support these experiments and enable extrapolation to larger devices, transport of sputtered and vaporized LMs was simulated using the ERO2.0 code. LM erosion was evaluated with HeatLMD, LM transport inside the separatrix with Aurora, and the stationary plasma background was obtained from narrow-grid SOLPS-ITER simulations complemented by METIS. For two COMPASS-U operational scenarios, the high-performance case #5400 and the ITER-like case #24300, the upper limits of acceptable confined-plasma contamination by LMs in the fully toroidal lower outer LM divertor case were assessed. The corresponding volume-averaged impurity concentrations were estimated as 14; 21 % (meaning 14 % and 21 % for scenarios #5400 and #24300, respectively) for Li, and 10 −5 ; 10 −4 % for Sn. The associated radiation losses from the confined plasma were estimated as 5; 9 % of the input power for Li, while remaining negligible for Sn. These estimates do not include the effects of edge-localized modes (ELMs), which will be investigated in future work. They also neglect Sn spitting, which may increase the risk of plasma disruptions unless Sn droplet transport is sufficiently suppressed by divertor design, and the possibility of runaway Li self-sputtering under conditions of thermally enhanced erosion yield exceeding unity combined with strong redeposition.
- 4 November 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
Open AccessFirst transport study of Li and Sn for COMPASS Upgrade tokamak
One of the principal research objectives of the COMPASS Upgrade (COMPASS-U) tokamak under construction in Prague is the investigation of reliable long-term plasma power exhaust solutions for future fusion reactors. Owing to its unique operational parameters, including magnetic field of 5 T, plasma current of 2 MA, divertor plasma densities exceeding 10 21 m -3 , and a tungsten first wall, COMPASS-U is expected to generate divertor surface-normal heat fluxes of several tens of MW/m 2 , relevant to future DEMO-class reactors, in 1–10 s discharges. Prototype liquid metal (LM) divertor tiles based on lithium (Li), tin (Sn), and their alloys will be experimentally tested. To support these experiments and enable extrapolation to larger devices, transport of sputtered and vaporized LMs was simulated using the ERO2.0 code. LM erosion was evaluated with HeatLMD, LM transport inside the separatrix with Aurora, and the stationary plasma background was obtained from narrow-grid SOLPS-ITER simulations complemented by METIS. For two COMPASS-U operational scenarios, the high-performance case #5400 and the ITER-like case #24300, the upper limits of acceptable confined-plasma contamination by LMs in the fully toroidal lower outer LM divertor case were assessed. The corresponding volume-averaged impurity concentrations were estimated as 14; 21 % (meaning 14 % and 21 % for scenarios #5400 and #24300, respectively) for Li, and 10 −5 ; 10 −4 % for Sn. The associated radiation losses from the confined plasma were estimated as 5; 9 % of the input power for Li, while remaining negligible for Sn. These estimates do not include the effects of edge-localized modes (ELMs), which will be investigated in future work. They also neglect Sn spitting, which may increase the risk of plasma disruptions unless Sn droplet transport is sufficiently suppressed by divertor design, and the possibility of runaway Li self-sputtering under conditions of thermally enhanced erosion yield exceeding unity combined with strong redeposition.
- 21 October 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 234
Optimizing fuelling pellet injection geometry for COMPASS Upgrade using HPI2
- 21 October 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 234
Optimizing fuelling pellet injection geometry for COMPASS Upgrade using HPI2
- Open Access
- 18 May 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (7)
Numerical modelling and optimization of vacuum field during plasma initiation in view of the operation of the COMPASS Upgrade tokamak
The COMPASS Upgrade tokamak will have dimensions R0 = 0.894 m and a ∼ 0.27 m with high-field (Bt ∼ 5 T), high-current (Ip ∼ 2 MA), high-triangularity (δ ∼ 0.4–0.6) capabilities. This contribution aims at establishing open loop circuits currents scenarios for complete plasma initiation (breakdown and burn-through) and initial current ramp-up in both low field (2.5 T) and high field (5 T) conditions. A complete electro-magnetic model of the future device was derived and linearized through the FIESTA code : in particular the Passive Stabilizing Plates have been consistently included. The optimization algorithm aims at providing the currents necessary to generate the proper vacuum field and maintain the plasma in its initial position against the inner limiter. It relies on the YFactory optimization tool. We present for the first time a fully optimized plasma initiation strategy that provides the feed-forward currents of all the coils from breakdown to the ∼ 150 kA mark, without any active feedback. The optimization takes into account a certain number of control points for the field and flux values which allows to guide the null size and shape, as well as ensures initial radial and vertical stability. The breakdown strategy is discussed with respect to the null geometry and the maximum loop voltage requested during the breakdown. The outputs of the optimization are tested via the DYON code for a reasonable range of neutral prefill densities. The duration of burn-through is analysed and an optimum breakdown configuration is identified that minimizes burn-through time, current consumption and stresses. The optimization is further refined in order to minimize the stress in the sliding joint of the Toroidal Field coil which is evaluated by ANSYS APDL model. The combined approach provides an operational space for COMPASS-U startup that is consistent with both electromagnetic and structural constraints.
- 18 May 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (7)
Open AccessNumerical modelling and optimization of vacuum field during plasma initiation in view of the operation of the COMPASS Upgrade tokamak
The COMPASS Upgrade tokamak will have dimensions R0 = 0.894 m and a ∼ 0.27 m with high-field (Bt ∼ 5 T), high-current (Ip ∼ 2 MA), high-triangularity (δ ∼ 0.4–0.6) capabilities. This contribution aims at establishing open loop circuits currents scenarios for complete plasma initiation (breakdown and burn-through) and initial current ramp-up in both low field (2.5 T) and high field (5 T) conditions. A complete electro-magnetic model of the future device was derived and linearized through the FIESTA code : in particular the Passive Stabilizing Plates have been consistently included. The optimization algorithm aims at providing the currents necessary to generate the proper vacuum field and maintain the plasma in its initial position against the inner limiter. It relies on the YFactory optimization tool. We present for the first time a fully optimized plasma initiation strategy that provides the feed-forward currents of all the coils from breakdown to the ∼ 150 kA mark, without any active feedback. The optimization takes into account a certain number of control points for the field and flux values which allows to guide the null size and shape, as well as ensures initial radial and vertical stability. The breakdown strategy is discussed with respect to the null geometry and the maximum loop voltage requested during the breakdown. The outputs of the optimization are tested via the DYON code for a reasonable range of neutral prefill densities. The duration of burn-through is analysed and an optimum breakdown configuration is identified that minimizes burn-through time, current consumption and stresses. The optimization is further refined in order to minimize the stress in the sliding joint of the Toroidal Field coil which is evaluated by ANSYS APDL model. The combined approach provides an operational space for COMPASS-U startup that is consistent with both electromagnetic and structural constraints.
- Open Access
- 28 April 2026
- Published by Elsevier in SSRN Electronic Journal
Optimizing fuelling pellet injection geometry for COMPASS Upgrade using HPI2
COMPASS Upgrade (COMPASS-U) [1] is a high-magnetic field (5 T) tokamak, currently being built at the Institute of Plasma Physics in Prague. The HUN-REN Centre for Energy Research plans to develop a pellet injector for COMPASS-U. This work aims to optimize the pellet injector parameters - pellet velocity, size, injection direction, and investigates the pellet-plasma interaction, using various plasma scenarios of the Compass Upgrade tokamak with the HPI2 code [2]. HPI2 is a widely used pellet injection simulation code that can handle 3D geometries and related secondary phenomena, like inhomogeneous pellet ablation.The dependence of material deposition and penetration depth on pellet size and velocity were examined, and for the desired material deposition, pellets with a radius of 0.75 mm should be injected into the plasma. Higher injection velocity is advantageous, but based on technical considerations, simulations were run using an injection velocity of 500 m/s.The properties of different injection directions were explored, in several scenarios, from early L-mode to the high-performance H-mode scenario, based on which the optimal injection geometry of the pellet injector was defined. While LFS injection is the easiest to realize technically, it results in the least efficient fuelling, as expected, as drift phenomena quickly accelerates the pellet cloud out from the plasma. The internal, HFS injection is the most efficient, where the drift direction points inward the plasma; due to accessibility constraints, pellets cannot be delivered here. A good compromise is the vertical (VHFS) injection, from an existing port. Relaxation of the plasma profiles after the injection were also investigated to characterise the pacing requirements of the injection.[1]: M. Komm et al, COMPASS Upgrade: a high-field tokamak for ITER- and DEMO-relevant research (2024) Nucl. Fusion 64 076028[2]: F. Koechl et al, Modelling of Pellet Particle Ablation and Deposition: The Hydrogen Pellet Injection code HPI2 (2014), EFDA–JET–PR(12)57, Nuclear Fusion
- 28 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessOptimizing fuelling pellet injection geometry for COMPASS Upgrade using HPI2
COMPASS Upgrade (COMPASS-U) [1] is a high-magnetic field (5 T) tokamak, currently being built at the Institute of Plasma Physics in Prague. The HUN-REN Centre for Energy Research plans to develop a pellet injector for COMPASS-U. This work aims to optimize the pellet injector parameters - pellet velocity, size, injection direction, and investigates the pellet-plasma interaction, using various plasma scenarios of the Compass Upgrade tokamak with the HPI2 code [2]. HPI2 is a widely used pellet injection simulation code that can handle 3D geometries and related secondary phenomena, like inhomogeneous pellet ablation.The dependence of material deposition and penetration depth on pellet size and velocity were examined, and for the desired material deposition, pellets with a radius of 0.75 mm should be injected into the plasma. Higher injection velocity is advantageous, but based on technical considerations, simulations were run using an injection velocity of 500 m/s.The properties of different injection directions were explored, in several scenarios, from early L-mode to the high-performance H-mode scenario, based on which the optimal injection geometry of the pellet injector was defined. While LFS injection is the easiest to realize technically, it results in the least efficient fuelling, as expected, as drift phenomena quickly accelerates the pellet cloud out from the plasma. The internal, HFS injection is the most efficient, where the drift direction points inward the plasma; due to accessibility constraints, pellets cannot be delivered here. A good compromise is the vertical (VHFS) injection, from an existing port. Relaxation of the plasma profiles after the injection were also investigated to characterise the pacing requirements of the injection.[1]: M. Komm et al, COMPASS Upgrade: a high-field tokamak for ITER- and DEMO-relevant research (2024) Nucl. Fusion 64 076028[2]: F. Koechl et al, Modelling of Pellet Particle Ablation and Deposition: The Hydrogen Pellet Injection code HPI2 (2014), EFDA–JET–PR(12)57, Nuclear Fusion
- Open Access
- 23 February 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (3) , 036043
Multi-machine validation of plasma initiation modelling and prospects for future devices: Predicting plasma initiation using only hardware design and control room input data
This paper reports on the generic prediction capability of full electromagnetic plasma initiation modelling with DYON, which was carried out for the first time in fusion research by the joint modelling of the International Tokamak Physics Activity—Integrating Operation Scenario group. The following devices were included in the experiment database: VEST (spherical torus, copper coils, Stainless steel wall, R / a = 0.3 m/0.2 m, V v = 3.7 m 3 ), MAST-U (spherical torus, copper coils, C wall, R / a = 0.7 m/0.5 m, V v = 55 m 3 ), EAST (conventional tokamak, superconducting coils, metallic wall, R / a = 1.85 m/0.5 m, V v = 38 m 3 ), DIII-D (conventional tokamak, copper coils, C wall, R / a = 1.67 m/0.65 m, V v = 35 m 3 ), and KSTAR (conventional tokamak, superconducting coils, C wall, R / a = 1.8 m/0.5 m, V v = 55 m 3 ). Despite the different hardware features of the devices, the required operating spaces of the loop voltage induction and prefill gas pressure for inductive plasma initiation in each device were successfully reproduced by the predictive simulations with DYON using only the individual hardware design and the control room input data for each discharge. This successful validation across multiple machines demonstrates that the full electromagnetic DYON modelling can capture the essential physics of inductive plasma initiation. The simulation settings commonly employed for all modelling and the modifications necessary to account for the discrepancies between individual devices are reported. Predictions for ITER based on the multi-machine validation indicate that a wide range of prefill gas pressures exists for the Townsend breakdown and the plasma burn-through (0.01–1.5 mPa).
- 23 February 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (3) , 036043
Open AccessMulti-machine validation of plasma initiation modelling and prospects for future devices: Predicting plasma initiation using only hardware design and control room input data
This paper reports on the generic prediction capability of full electromagnetic plasma initiation modelling with DYON, which was carried out for the first time in fusion research by the joint modelling of the International Tokamak Physics Activity—Integrating Operation Scenario group. The following devices were included in the experiment database: VEST (spherical torus, copper coils, Stainless steel wall, R / a = 0.3 m/0.2 m, V v = 3.7 m 3 ), MAST-U (spherical torus, copper coils, C wall, R / a = 0.7 m/0.5 m, V v = 55 m 3 ), EAST (conventional tokamak, superconducting coils, metallic wall, R / a = 1.85 m/0.5 m, V v = 38 m 3 ), DIII-D (conventional tokamak, copper coils, C wall, R / a = 1.67 m/0.65 m, V v = 35 m 3 ), and KSTAR (conventional tokamak, superconducting coils, C wall, R / a = 1.8 m/0.5 m, V v = 55 m 3 ). Despite the different hardware features of the devices, the required operating spaces of the loop voltage induction and prefill gas pressure for inductive plasma initiation in each device were successfully reproduced by the predictive simulations with DYON using only the individual hardware design and the control room input data for each discharge. This successful validation across multiple machines demonstrates that the full electromagnetic DYON modelling can capture the essential physics of inductive plasma initiation. The simulation settings commonly employed for all modelling and the modifications necessary to account for the discrepancies between individual devices are reported. Predictions for ITER based on the multi-machine validation indicate that a wide range of prefill gas pressures exists for the Townsend breakdown and the plasma burn-through (0.01–1.5 mPa).
- Open Access
- 20 January 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (2)
Study of ideal and resistive MHD stability of COMPASS Upgrade scenarios
Assessing magnetohydrodynamic (MHD) stability of the envisaged scenarios for the operation of a new tokamak is of primary importance for machine performance and safety. COMPASS Upgrade (COMPASS-U) is a compact tokamak which is being built at the Institute of Plasma Physics in Prague; COMPASS-U will explore various plasma scenarios, characterized by different magnetic fields, plasma currents and plasma shapes. Systematic stability calculations with MARS-F code [Liu et al., Phys. Plasmas 7, 3681 (2000)] were performed on the main representative scenarios for COMPASS-U operation and the most unstable modes were identified. The considered scenarios were found to be unstable to internal kink modes, which implies the presence of sawtooth activity. On the other hand, the nominal β (ratio of the volume-averaged plasma pressure to the magnetic pressure) of the scenarios is below the no-wall limit for stability to external kink modes. The main scenarios, characterized by 3 < q95 < 4, are stable with respect to tearing modes for nominal β because of the stabilizing Glasser-Greene-Johnson effect, while scenarios with q95 < 3 are expected to be unstable for finite β. The stabilization produced by an ideal wall placed close to the plasma suggests that the finite-β destabilization is caused by coupling to pressure-driven external modes. A preliminary assessment of stability with respect to pressure-driven modes was attempted. Stability with respect to neoclassical tearing modes (NTMs) was assessed by using generalized Rutherford equation; stabilization of NTMs by electron cyclotron heating (ECH) and current drive (ECCD) was evaluated.
- 20 January 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (2)
Open AccessStudy of ideal and resistive MHD stability of COMPASS Upgrade scenarios
Assessing magnetohydrodynamic (MHD) stability of the envisaged scenarios for the operation of a new tokamak is of primary importance for machine performance and safety. COMPASS Upgrade (COMPASS-U) is a compact tokamak which is being built at the Institute of Plasma Physics in Prague; COMPASS-U will explore various plasma scenarios, characterized by different magnetic fields, plasma currents and plasma shapes. Systematic stability calculations with MARS-F code [Liu et al., Phys. Plasmas 7, 3681 (2000)] were performed on the main representative scenarios for COMPASS-U operation and the most unstable modes were identified. The considered scenarios were found to be unstable to internal kink modes, which implies the presence of sawtooth activity. On the other hand, the nominal β (ratio of the volume-averaged plasma pressure to the magnetic pressure) of the scenarios is below the no-wall limit for stability to external kink modes. The main scenarios, characterized by 3 < q95 < 4, are stable with respect to tearing modes for nominal β because of the stabilizing Glasser-Greene-Johnson effect, while scenarios with q95 < 3 are expected to be unstable for finite β. The stabilization produced by an ideal wall placed close to the plasma suggests that the finite-β destabilization is caused by coupling to pressure-driven external modes. A preliminary assessment of stability with respect to pressure-driven modes was attempted. Stability with respect to neoclassical tearing modes (NTMs) was assessed by using generalized Rutherford equation; stabilization of NTMs by electron cyclotron heating (ECH) and current drive (ECCD) was evaluated.
- Open Access
- 10 June 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (6) , 065030
Physics drivers for the plasma-facing component design of the COMPASS-U tokamak
The main drivers for the metallic plasma-facing component (PFC) design of the COMPASS Upgrade (COMPASS-U) tokamak (B T ⩽5 T, I P ⩽ 2 MA, R geo = 0.9 m, a geo = 0.27 m, t flattop ⩽ 3 s) derived from physics considerations are presented in this paper. Requirements on the plasma-wall gaps are given based on previous experimental observations in other devices. Gaps at the inner/outer midplane are set to minimum values 20 and 40 mm, respectively, to allow all magnetic equilibria in the lower and upper single-null configurations to fit in the PFC outline, to allow an efficient flow in the scrape-off layer towards the divertor and to minimize the impurity flux from the wall. The closed tungsten divertor was designed with a similar shape to ITER’s divertor since COMPASS-U has a similar aspect ratio and uses an ITER-like equilibrium for its baseline scenario. Steady-state thermal loads are calculated at the outer strike-point, where they are expected to be the highest, in attached conditions using a 0D energy balance (⩾150 MW m−2) and in detached conditions using BIT1 kinetic calculations (∼70 MW m−2). Transient thermal loads range from 1.2 MJ m−2 for ELMs (maximum parallel peak energy fluence at targets) to 0.6–1.2 GW m−2 in ∼0.5 ms for high-energy vertical displacement events (maximum perpendicular heat flux density). Electromagnetic loads are calculated during disruptions using an in-house parametric model, accounting for current quench (CQ) and halo current contributions and validated by simulations using the CarMa0NL code, which is able to describe the nonlinear evolution of axisymmetric plasmas in the presence of 3D volumetric structures. The CQ rate is expected to be at least δI P/δt = 3 MA ms−1, and the halo current magnitude is set to 75% of the pre-disruptive maximum plasma current, according to the ITPA disruption database, yielding I halo = 1.5 MA. Maximum total force acts on the bottom divertor baffle with a value of ∼60 kN and the corresponding total torque is ∼4 kN m.
- 10 June 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (6) , 065030
Open AccessPhysics drivers for the plasma-facing component design of the COMPASS-U tokamak
The main drivers for the metallic plasma-facing component (PFC) design of the COMPASS Upgrade (COMPASS-U) tokamak (B T ⩽5 T, I P ⩽ 2 MA, R geo = 0.9 m, a geo = 0.27 m, t flattop ⩽ 3 s) derived from physics considerations are presented in this paper. Requirements on the plasma-wall gaps are given based on previous experimental observations in other devices. Gaps at the inner/outer midplane are set to minimum values 20 and 40 mm, respectively, to allow all magnetic equilibria in the lower and upper single-null configurations to fit in the PFC outline, to allow an efficient flow in the scrape-off layer towards the divertor and to minimize the impurity flux from the wall. The closed tungsten divertor was designed with a similar shape to ITER’s divertor since COMPASS-U has a similar aspect ratio and uses an ITER-like equilibrium for its baseline scenario. Steady-state thermal loads are calculated at the outer strike-point, where they are expected to be the highest, in attached conditions using a 0D energy balance (⩾150 MW m−2) and in detached conditions using BIT1 kinetic calculations (∼70 MW m−2). Transient thermal loads range from 1.2 MJ m−2 for ELMs (maximum parallel peak energy fluence at targets) to 0.6–1.2 GW m−2 in ∼0.5 ms for high-energy vertical displacement events (maximum perpendicular heat flux density). Electromagnetic loads are calculated during disruptions using an in-house parametric model, accounting for current quench (CQ) and halo current contributions and validated by simulations using the CarMa0NL code, which is able to describe the nonlinear evolution of axisymmetric plasmas in the presence of 3D volumetric structures. The CQ rate is expected to be at least δI P/δt = 3 MA ms−1, and the halo current magnitude is set to 75% of the pre-disruptive maximum plasma current, according to the ITPA disruption database, yielding I halo = 1.5 MA. Maximum total force acts on the bottom divertor baffle with a value of ∼60 kN and the corresponding total torque is ∼4 kN m.
- Open Access
- 24 January 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (2) , 025030
Feasibility of electron cyclotron resonance heating for high-field and high-density tokamak COMPASS Upgrade
Electron cyclotron resonance heating is one of the additional heating systems that is going to be installed at the future high-field tokamak COMPASS Upgrade in Prague. Experimental scenarios cover a wide range of operational parameters, thus the designed heating system has to be exceptionally versatile. The simulations of wave propagation in plasma have been performed using the TORBEAM code. The obtained results yield important information about density limitations and other constraints of ECRH at COMPASS Upgrade, which are necessary for the subsequent design phase. A brief description of intended experimental scenarios is provided together with simulations of the influence of ECRH on COMPASS Upgrade plasma. Efforts should be made to prevent high-density discharges in H-mode plasma. If the high densities can be prevented, the 105/140 GHz frequency heating system provides sufficient heating in most experimental scenarios. The utilization of 170 GHz would be beneficial for intermediate magnetic field scenarios as well. In the future, the potential upgrade towards the 200+ GHz systems would help to tackle the problems with natural H-mode density.
- 24 January 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (2) , 025030
Open AccessFeasibility of electron cyclotron resonance heating for high-field and high-density tokamak COMPASS Upgrade
Electron cyclotron resonance heating is one of the additional heating systems that is going to be installed at the future high-field tokamak COMPASS Upgrade in Prague. Experimental scenarios cover a wide range of operational parameters, thus the designed heating system has to be exceptionally versatile. The simulations of wave propagation in plasma have been performed using the TORBEAM code. The obtained results yield important information about density limitations and other constraints of ECRH at COMPASS Upgrade, which are necessary for the subsequent design phase. A brief description of intended experimental scenarios is provided together with simulations of the influence of ECRH on COMPASS Upgrade plasma. Efforts should be made to prevent high-density discharges in H-mode plasma. If the high densities can be prevented, the 105/140 GHz frequency heating system provides sufficient heating in most experimental scenarios. The utilization of 170 GHz would be beneficial for intermediate magnetic field scenarios as well. In the future, the potential upgrade towards the 200+ GHz systems would help to tackle the problems with natural H-mode density.
- Open Access
- 15 November 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (1) , 016014
Scaling of HeatLMD-simulated impurity outflux from COMPASS-U liquid metal divertor
The liquid metal divertor (LMD) concept offers a promising solution to manage extreme heat loads in plasma devices. This study presents predictive simulations using the HeatLMD model for the COMPASS-U tokamak with a full toroidal liquid metal divertor, expected to achieve reactor-relevant divertor heat flux densities. We derive the scaling of the Li|Sn outflux over 7 assumed independent parameters, transferable to other tokamaks. Its transport to LCFS (via ERO2.0) and its radiation (via Aurora and FACIT) predicts acceptably low lithium concentration and negligible plasma cooling. However, for tin, the medium power scenario requires backside cooling beyond the capability of the ITER-like water-cooled divertor, though a temporary heat absorber can approximate this for a 1 s plasma pulse. For incident divertor power exceeding 2 MW and strike point T e < 10 eV, HeatLMD predicts significant tin plasma radiative disruption.
- 15 November 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (1) , 016014
Open AccessScaling of HeatLMD-simulated impurity outflux from COMPASS-U liquid metal divertor
The liquid metal divertor (LMD) concept offers a promising solution to manage extreme heat loads in plasma devices. This study presents predictive simulations using the HeatLMD model for the COMPASS-U tokamak with a full toroidal liquid metal divertor, expected to achieve reactor-relevant divertor heat flux densities. We derive the scaling of the Li|Sn outflux over 7 assumed independent parameters, transferable to other tokamaks. Its transport to LCFS (via ERO2.0) and its radiation (via Aurora and FACIT) predicts acceptably low lithium concentration and negligible plasma cooling. However, for tin, the medium power scenario requires backside cooling beyond the capability of the ITER-like water-cooled divertor, though a temporary heat absorber can approximate this for a 1 s plasma pulse. For incident divertor power exceeding 2 MW and strike point T e < 10 eV, HeatLMD predicts significant tin plasma radiative disruption.
- Open Access
- 26 September 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (12) , 126010
Validation of prediction capability of operating space for plasma initiation in MAST-U
DYON is a plasma initiation modelling code that solves the differential equation system of the full circuit equations (plasma current, active coil currents and eddy currents in full passive structures) and 0D global energy and particle balance equations (Kim 2022 Nucl. Fusion 62 126012). In order to test the capability of the full electromagnetic plasma initiation model to predict individual discharges in experiments and thus the operating space in the device, a dedicated experimental database was built in MAST-U by scanning the prefilled gas pressure p 0 and the induced loop voltage V loop . In the experimental operating space of p 0 and V loop the lower and the upper limits of p 0 are determined by the plasma breakdown failure and the plasma burn-through failure, respectively. The lower limit of V loop is determined by the plasma burn-through failure. By directly reading the control room data used in each discharge (i.e. currents in the solenoid, poloidal field coils, and toroidal field coils, p 0, and gas puffing rate), the full electromagnetic DYON consistently predicted the failed breakdown, failed burn-through, and successful plasma initiation discharges in the experimental database, demonstrating its capability to predict the operating space for inductive plasma initiation. The Paschen curve calculated with the effective connection length in MAST-U indicates a much higher p 0 required for plasma breakdown than the experimental data, indicating that individual field line evaluation is necessary to calculate the quantitative requirements for Townsend breakdown. The demonstration in this paper shows that the full electromagnetic DYON could be a useful simulation tool to assess the feasibility of inductive plasma initiation and to optimise operating scenarios in future devices.
- 26 September 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (12) , 126010
Open AccessValidation of prediction capability of operating space for plasma initiation in MAST-U
DYON is a plasma initiation modelling code that solves the differential equation system of the full circuit equations (plasma current, active coil currents and eddy currents in full passive structures) and 0D global energy and particle balance equations (Kim 2022 Nucl. Fusion 62 126012). In order to test the capability of the full electromagnetic plasma initiation model to predict individual discharges in experiments and thus the operating space in the device, a dedicated experimental database was built in MAST-U by scanning the prefilled gas pressure p 0 and the induced loop voltage V loop . In the experimental operating space of p 0 and V loop the lower and the upper limits of p 0 are determined by the plasma breakdown failure and the plasma burn-through failure, respectively. The lower limit of V loop is determined by the plasma burn-through failure. By directly reading the control room data used in each discharge (i.e. currents in the solenoid, poloidal field coils, and toroidal field coils, p 0, and gas puffing rate), the full electromagnetic DYON consistently predicted the failed breakdown, failed burn-through, and successful plasma initiation discharges in the experimental database, demonstrating its capability to predict the operating space for inductive plasma initiation. The Paschen curve calculated with the effective connection length in MAST-U indicates a much higher p 0 required for plasma breakdown than the experimental data, indicating that individual field line evaluation is necessary to calculate the quantitative requirements for Townsend breakdown. The demonstration in this paper shows that the full electromagnetic DYON could be a useful simulation tool to assess the feasibility of inductive plasma initiation and to optimise operating scenarios in future devices.