Renna L. Nouwairi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Renna L. Nouwairi has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
James P. Landers
Department of Chemistry, University of Virginia, Charlottesville, VA, USA; Department of Mechanical Engineering, University of Virginia, Charlottesville, VA, USA; Department of Pathology, University of Virginia, Charlottesville, VA, USA
5 shared publications- James P. Landers
Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
3 shared publications - Rachelle Turiello
Department of Chemistry, University of Virginia, Charlottesville, VA, USA
3 shared publications - Killian C. O'COnnell
Department of Chemistry, University of Virginia, Charlottesville, Virginia 22904, USA
2 shared publications Leah M. Gunnoe
Department of Chemistry, University of Virginia, Charlottesville, VA, USA
2 shared publicationsAllison C. Burton
Department of Chemistry, University of Virginia, Charlottesville, VA, USA
1 shared publication
Latest Publications
- 10 April 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1356, 344046
Real-time amplification and high resolution melt analysis on a rapid microfluidic instrument
- 10 April 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1356, 344046
Real-time amplification and high resolution melt analysis on a rapid microfluidic instrument
- Open Access
- 28 December 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (1) , 300-311
Automated Nanoliter Volume Assay Optimization on a Cost-Effective Microfluidic Disc
Optimizing multireagent assays often requires successive titration of individual components until the optimal combination of conditions is achieved. This process is time-consuming, laborious, and often expensive since parallelized experimentation requires bulk consumption of reagents. Microfluidics presents a solution through miniaturization of standard processes by reducing reaction volume, executing multiple parallel workflows, and enabling automation. While single-digit microliter reactions can be effective, scaling to nanoliter volumes without employing droplets is difficult. We describe a cost-effective, customizable centrifugal microdisc for optimizing assays pertinent to a broad array of applications. An automated two-stage metering process leverages tunable, laser-actuated valves that retain defined fluidic volumes upon opening and meter discrete nanoliter volumes into downstream architecture. We demonstrate that ∼150 nL volumes could be metered and tuned for specific applications. We illustrate the potential for controlled metering of up to four reagents with high parallelization for rapid, cost-effective assay optimization with minimal manual intervention.
- 28 December 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (1) , 300-311
Open AccessAutomated Nanoliter Volume Assay Optimization on a Cost-Effective Microfluidic Disc
Optimizing multireagent assays often requires successive titration of individual components until the optimal combination of conditions is achieved. This process is time-consuming, laborious, and often expensive since parallelized experimentation requires bulk consumption of reagents. Microfluidics presents a solution through miniaturization of standard processes by reducing reaction volume, executing multiple parallel workflows, and enabling automation. While single-digit microliter reactions can be effective, scaling to nanoliter volumes without employing droplets is difficult. We describe a cost-effective, customizable centrifugal microdisc for optimizing assays pertinent to a broad array of applications. An automated two-stage metering process leverages tunable, laser-actuated valves that retain defined fluidic volumes upon opening and meter discrete nanoliter volumes into downstream architecture. We demonstrate that ∼150 nL volumes could be metered and tuned for specific applications. We illustrate the potential for controlled metering of up to four reagents with high parallelization for rapid, cost-effective assay optimization with minimal manual intervention.
- Open Access
- 10 September 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (18) , 4403-4421
Microwave-assisted extraction, separation, and chromogenic detection of laced marijuana for presumptive point-of-interdiction testing
Presumptive screening of cannabis lacing agents was performed using a centrifugal microdevice compatible with microwave assisted-solid phase extraction. Multicomponent chemometric analysis provided robust discrimination between controlled substances.
- 10 September 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (18) , 4403-4421
Open AccessMicrowave-assisted extraction, separation, and chromogenic detection of laced marijuana for presumptive point-of-interdiction testing
Presumptive screening of cannabis lacing agents was performed using a centrifugal microdevice compatible with microwave assisted-solid phase extraction. Multicomponent chemometric analysis provided robust discrimination between controlled substances.
- Open Access
- 27 November 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (1) , 97-112
A rotationally-driven dynamic solid phase sodium bisulfite conversion disc for forensic epigenetic sample preparation
An alternative method for epigenetic sample preparation by a rotationlly-driven, microfluidic sodium bisulfite conversion system for up to four samples in parallel.
- 27 November 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (1) , 97-112
Open AccessA rotationally-driven dynamic solid phase sodium bisulfite conversion disc for forensic epigenetic sample preparation
An alternative method for epigenetic sample preparation by a rotationlly-driven, microfluidic sodium bisulfite conversion system for up to four samples in parallel.
- 23 December 2022
- Published by Elsevier in Forensic Science International: Genetics
- Vol. 63, 102824
Taking the microfluidic approach to nucleic acid analysis in forensics: Review and perspectives
- 23 December 2022
- Published by Elsevier in Forensic Science International: Genetics
- Vol. 63, 102824
Taking the microfluidic approach to nucleic acid analysis in forensics: Review and perspectives
- Open Access
- 1 October 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1657
Rapid Microchip Electrophoretic Separation of Novel Transcriptomic Body Fluid Markers for Forensic Fluid Profiling
Initial screening of criminal evidence often involves serological testing of stains of unknown composition and/or origin discovered at a crime scene to determine the tissue of origin. This testing is presumptive but critical for contextualizing the scene. Here, we describe a microfluidic approach for body fluid profiling via fluorescent electrophoretic separation of a published mRNA panel that provides unparalleled specificity and sensitivity. This centrifugal microfluidic approach expedites and automates the electrophoresis process by allowing for simple, rotationally driven flow and polymer loading through a 5 cm separation channel; with each disc containing three identical domains, multi-sample analysis is possible with a single disc and multi-sample detection per disc. The centrifugal platform enables a series of sequential unit operations (metering, mixing, aliquoting, heating, storage) to execute automated electrophoretic separation. Results show on-disc fluorescent detection and sizing of amplicons to perform comparably with a commercial ‘gold standard’ benchtop instrument and permitted sensitive, empirical discrimination between five distinct body fluids in less than 10 min. Notably, our microfluidic platform represents a faster, simpler method for separation of a transcriptomic panel to be used for forensically relevant body fluid identification.
- 1 October 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1657
Open AccessRapid Microchip Electrophoretic Separation of Novel Transcriptomic Body Fluid Markers for Forensic Fluid Profiling
Initial screening of criminal evidence often involves serological testing of stains of unknown composition and/or origin discovered at a crime scene to determine the tissue of origin. This testing is presumptive but critical for contextualizing the scene. Here, we describe a microfluidic approach for body fluid profiling via fluorescent electrophoretic separation of a published mRNA panel that provides unparalleled specificity and sensitivity. This centrifugal microfluidic approach expedites and automates the electrophoresis process by allowing for simple, rotationally driven flow and polymer loading through a 5 cm separation channel; with each disc containing three identical domains, multi-sample analysis is possible with a single disc and multi-sample detection per disc. The centrifugal platform enables a series of sequential unit operations (metering, mixing, aliquoting, heating, storage) to execute automated electrophoretic separation. Results show on-disc fluorescent detection and sizing of amplicons to perform comparably with a commercial ‘gold standard’ benchtop instrument and permitted sensitive, empirical discrimination between five distinct body fluids in less than 10 min. Notably, our microfluidic platform represents a faster, simpler method for separation of a transcriptomic panel to be used for forensically relevant body fluid identification.
- 9 August 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (18) , 3424-3435
Ultra-rapid real-time microfluidic RT-PCR instrument for nucleic acid analysis
The polymerase chain reaction (PCR) is paramount in nucleic acid amplification testing, and for many assays, the use of PCR or qPCR is considered the ‘gold standard’. While instrumentation for executing PCR has advanced over the last two decades, a growing interest in point-of-need testing has highlighted the deficit that exists for ‘rapid PCR’ systems. Here, we describe a field-forward prototype instrument capable of ultra-fast thermal cycling for real-time PCR amplification of DNA and RNA. The custom-designed, injection-molded microfluidic chips interface with a novel mechatronic system to complete 40 cycles of real-time PCR in under 10 minutes, an 84% reduction in time compared to a standard 50 minute assay. Such rapid amplification is enabled by two thermoelectric Peltiers capable of efficiently heating and cooling the sample at 12 and 10 °C s−1, respectively. Judicious selection and strategic placement of the thermal cyclers and fluorescence detector relative to the microchip enable synchronized thermal cycling and fluorescence monitoring, further reducing time-to-result. Robust amplification and detection of DNA and RNA targets empowers laboratories to achieve rapid, actionable information in endless applications.
- 9 August 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (18) , 3424-3435
Ultra-rapid real-time microfluidic RT-PCR instrument for nucleic acid analysis
The polymerase chain reaction (PCR) is paramount in nucleic acid amplification testing, and for many assays, the use of PCR or qPCR is considered the ‘gold standard’. While instrumentation for executing PCR has advanced over the last two decades, a growing interest in point-of-need testing has highlighted the deficit that exists for ‘rapid PCR’ systems. Here, we describe a field-forward prototype instrument capable of ultra-fast thermal cycling for real-time PCR amplification of DNA and RNA. The custom-designed, injection-molded microfluidic chips interface with a novel mechatronic system to complete 40 cycles of real-time PCR in under 10 minutes, an 84% reduction in time compared to a standard 50 minute assay. Such rapid amplification is enabled by two thermoelectric Peltiers capable of efficiently heating and cooling the sample at 12 and 10 °C s−1, respectively. Judicious selection and strategic placement of the thermal cyclers and fluorescence detector relative to the microchip enable synchronized thermal cycling and fluorescence monitoring, further reducing time-to-result. Robust amplification and detection of DNA and RNA targets empowers laboratories to achieve rapid, actionable information in endless applications.
- Open Access
- 8 July 2022
- Published by Wiley in Electrophoresis
- Vol. 43 (16-17) , 1746-1754
Rapid, Inexpensive Fabrication of Electrophoretic Microdevices for Fluorescence Detection
The laser print, cut, and laminate (PCL) method for microfluidic device fabrication can be leveraged for rapid and inexpensive prototyping of electrophoretic microchips useful for optimizing separation conditions. The rapid prototyping capability allows the evaluation of fluidic architecture, applied fields, reagent concentrations, and sieving matrix, all within the context of using fluorescence-compatible substrates. Cyclic olefin copolymer and toner-coated polyethylene terephthalate (tPeT) were utilized with the PCL technique and bonding methods optimized to improve device durability during electrophoresis. A series of separation channel designs and centrifugation conditions that provided successful loading of sieving polymer in less than 3 min was described. Separation of a 400-base DNA sizing ladder provided calculated base resolution between 3 and 4 bases, a greater than 18-fold improvement over separations on similar substrates. Finally, the accuracy and precision capabilities of these devices were demonstrated by separating and sizing DNA fragments of 147 and 167 bases as 148.62 +/- 2 and 166.48 +/- 3 bases, respectively.
- 8 July 2022
- Published by Wiley in Electrophoresis
- Vol. 43 (16-17) , 1746-1754
Open AccessRapid, Inexpensive Fabrication of Electrophoretic Microdevices for Fluorescence Detection
The laser print, cut, and laminate (PCL) method for microfluidic device fabrication can be leveraged for rapid and inexpensive prototyping of electrophoretic microchips useful for optimizing separation conditions. The rapid prototyping capability allows the evaluation of fluidic architecture, applied fields, reagent concentrations, and sieving matrix, all within the context of using fluorescence-compatible substrates. Cyclic olefin copolymer and toner-coated polyethylene terephthalate (tPeT) were utilized with the PCL technique and bonding methods optimized to improve device durability during electrophoresis. A series of separation channel designs and centrifugation conditions that provided successful loading of sieving polymer in less than 3 min was described. Separation of a 400-base DNA sizing ladder provided calculated base resolution between 3 and 4 bases, a greater than 18-fold improvement over separations on similar substrates. Finally, the accuracy and precision capabilities of these devices were demonstrated by separating and sizing DNA fragments of 147 and 167 bases as 148.62 +/- 2 and 166.48 +/- 3 bases, respectively.
- 22 December 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (1) , 367-387
Microchip Electrophoresis for Fluorescence-Based Measurement of Polynucleic Acids: Recent Developments
- 22 December 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (1) , 367-387
Microchip Electrophoresis for Fluorescence-Based Measurement of Polynucleic Acids: Recent Developments