Killian C. O'COnnell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Killian C. O'COnnell has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
James P. Landers
Department of Chemistry, University of Virginia, Charlottesville, VA, USA; Department of Mechanical Engineering, University of Virginia, Charlottesville, VA, USA; Department of Pathology, University of Virginia, Charlottesville, VA, USA
3 shared publicationsBrennan M. Stewart
Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia 22904, USA
2 shared publicationsNicola K. Lawless
Department of Biology, University of Virginia, Charlottesville, Virginia 22904, USA
2 shared publications- Renna L. Nouwairi
Department of Chemistry, University of Virginia, Charlottesville, VA, USA
2 shared publications Allison C. Burton
Department of Chemistry, University of Virginia, Charlottesville, VA, USA
1 shared publicationEmmet T. Costen
Aerospace Structural Research Corporation, Milford, Connecticut, 06460 USA
1 shared publication
Latest Publications
- 10 April 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1356, 344046
Real-time amplification and high resolution melt analysis on a rapid microfluidic instrument
- 10 April 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1356, 344046
Real-time amplification and high resolution melt analysis on a rapid microfluidic instrument
- Open Access
- 10 September 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (18) , 4403-4421
Microwave-assisted extraction, separation, and chromogenic detection of laced marijuana for presumptive point-of-interdiction testing
Presumptive screening of cannabis lacing agents was performed using a centrifugal microdevice compatible with microwave assisted-solid phase extraction. Multicomponent chemometric analysis provided robust discrimination between controlled substances.
- 10 September 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (18) , 4403-4421
Open AccessMicrowave-assisted extraction, separation, and chromogenic detection of laced marijuana for presumptive point-of-interdiction testing
Presumptive screening of cannabis lacing agents was performed using a centrifugal microdevice compatible with microwave assisted-solid phase extraction. Multicomponent chemometric analysis provided robust discrimination between controlled substances.
- Open Access
- 26 June 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (14) , 3130-3159
Integrated membranes within centrifugal microfluidic devices: a review
Membranes represent a powerful technology for numerous lab-on-a-disc applications. This review provides a comprehensive introduction to these versatile materials as well as strategies for their integration within centrifugal microdevices.
- 26 June 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (14) , 3130-3159
Open AccessIntegrated membranes within centrifugal microfluidic devices: a review
Membranes represent a powerful technology for numerous lab-on-a-disc applications. This review provides a comprehensive introduction to these versatile materials as well as strategies for their integration within centrifugal microdevices.
- 27 May 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (13) , 2549-2565
Dielectric heating of highly corrosive and oxidizing reagents on a hybrid glass microfiber–polymer centrifugal microfluidic device
Many assays necessitate the use of highly concentrated acids, powerful oxidizing agents, or a combination of the two. Although microfluidic devices offer vast potential for rapid analytical interrogation at the point-of-need (PON), they cannot escape the fundamental requirement for reagent compatibility. Worse, many innovative protocols have been developed that would represent a significant improvement to current field-forward practices within their respective disciplines, but adoption falters due to chemical incompatibility with challenging reagents. Polymeric centrifugal microfluidic devices meet many of the needs for accommodating complex chemical or biochemical protocols in a multiplexed and automatable format. Yet, they also struggle to accommodate highly reactive chemical components long term. In this work, we report on a simple and inexpensive reagent storage strategy that bypasses the typical complexity involved with integration of liquid reagents on microfluidic devices. Moreover, we demonstrate microdevice compatibility and operation after six months of corrosive reagent storage as well as post dielectric heating. This new strategy allows for storage of multiple highly corrosive and oxidative reagents simultaneously, enhancing the possibilities for multistep assay integration at the PON for a diverse array of applications. Successful detection after one week of corrosive reagent storage of an illicit drug and neurotransmitter metabolite, for forensic and clinical applications, is demonstrated. Furthermore, environmental sample preparation via microwave-assisted wet acid digestion is performed on-disc and integrated with downstream detection. Quantitative detection of a heavy metal in soil is achieved by way of on-disc calibration and found to be accurate within 2.4% compared to a gold standard reference (ICP-OES).
- 27 May 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (13) , 2549-2565
Dielectric heating of highly corrosive and oxidizing reagents on a hybrid glass microfiber–polymer centrifugal microfluidic device
Many assays necessitate the use of highly concentrated acids, powerful oxidizing agents, or a combination of the two. Although microfluidic devices offer vast potential for rapid analytical interrogation at the point-of-need (PON), they cannot escape the fundamental requirement for reagent compatibility. Worse, many innovative protocols have been developed that would represent a significant improvement to current field-forward practices within their respective disciplines, but adoption falters due to chemical incompatibility with challenging reagents. Polymeric centrifugal microfluidic devices meet many of the needs for accommodating complex chemical or biochemical protocols in a multiplexed and automatable format. Yet, they also struggle to accommodate highly reactive chemical components long term. In this work, we report on a simple and inexpensive reagent storage strategy that bypasses the typical complexity involved with integration of liquid reagents on microfluidic devices. Moreover, we demonstrate microdevice compatibility and operation after six months of corrosive reagent storage as well as post dielectric heating. This new strategy allows for storage of multiple highly corrosive and oxidative reagents simultaneously, enhancing the possibilities for multistep assay integration at the PON for a diverse array of applications. Successful detection after one week of corrosive reagent storage of an illicit drug and neurotransmitter metabolite, for forensic and clinical applications, is demonstrated. Furthermore, environmental sample preparation via microwave-assisted wet acid digestion is performed on-disc and integrated with downstream detection. Quantitative detection of a heavy metal in soil is achieved by way of on-disc calibration and found to be accurate within 2.4% compared to a gold standard reference (ICP-OES).