KSKiyo Shibata

Kiyo Shibata

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kiyo Shibata has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Atsushi Fujiwara

    Affiliation Department of Orthoptics, Faculty of Rehabilitation, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan

    1 shared publication
  • H. Fujii

    Steel R&D Laboratory, Nippon Steel Corporation, Shintomi, Futtsu‐shi, Chiba‐ken, 293‐8511, Japan

    1 shared publication
  • Ichiro Hamasaki

    Department of Ophthalmology, Okayama University Hospital, Okayama 700-8558, Japan

    1 shared publication
  • Keisuke Kanenaga

    Affiliation Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama City, Okayama, Japan

    1 shared publication
  • Masanori Nakazawa

    Affiliation Department of Ophthalmology, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan

    1 shared publication
  • Reika Kono

    Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama City, Japan

    1 shared publication

Latest Publications

  • Open Access

    Shape analysis of rectus extraocular muscles with age and axial length using anterior segment optical coherence tomography

    by Kiyo Shibata, Atsushi Fujiwara, Ichiro Hamasaki, Takehiro Shimizu, Reika Kono, Keisuke Kanenaga, Masanori Nakazawa, Yuki Morizane

    Purpose This study aimed to evaluate the shape of the extraocular muscles (EOMs) in normal subjects using the en-face images of anterior segment optical coherence tomography (AS-OCT). The EOM insertion and the direction of the muscle fibers were investigated. Subjects and methods A total of 97 healthy normal subjects (194 eyes) at Okayama University Hospital (age, 47.1 +/- 21.5 years; range, 8-79 years) participated in the study. A series of 256 tomographic images of the rectus EOMs were captured using the C-scan function of the AS-OCT (CASIA2, TOMEY Co., Japan), and the images were converted to en-face images in multi-TIFF format. The anterior chamber angle to EOM insertion distance (AID) and the angle of the muscle fibers from the insertion site (angle of muscles) were measured from the images. The correlations of AID and angle of muscles with age and axial length were investigated and evaluated. Results AID and angle of muscles were significantly correlated with age or axial length in some EOMs. The AIDs of medial rectus (MR) (P = 0.000) and superior rectus (SR) (P = 0.005) shortened with age. The AIDs of MR (P = 0.001) and inferior rectus (IR) (P = 0.035) elongated with axial length, whereas lateral rectus (LR) (P = 0.013) shortened. The angles of MR (P = 0.001) and LR (P = 0.000) were found to have a more downward direction toward the posterior in older subjects. Conclusion En-face images can be created by AS-OCT, and the shape of the EOMs in normal subjects using these image measurements was available. With the ability to assess the EOMs, AID and angle of muscles are expected give useful information for treating and diagnosing strabismus-related diseases.


  • Notch Effect on Tensile Deformation Behavior of 304L and 316L Steels in Liquid Helium and Hydrogen

    by K. Shibata, H. Fujii

    Tensile tests of type 304L and 316L steels were carried out using round bar specimens with a notch in liquid helium, hydrogen, liquid nitrogen and at ambient temperature. The obtained tensile strengths were compared with the tensile strengths of smooth specimens. For smooth specimens, tensile strength increased with a decrease in temperature and the strengths in liquid helium and hydrogen show similar values in both steels. For notched specimen of 304L steel, tensile strength (including fracture strength) increased noticeably from ambient to liquid nitrogen temperature but showed a large decrease in liquid helium and hydrogen. In liquid hydrogen and helium, the tensile strength is a little lower in liquid hydrogen than in liquid helium and both strengths are lower than tensile strengths of smooth specimens. For notched specimen of 316L steel, an increase in tensile strength from ambient to liquid nitrogen temperature was not so large and a decrease from liquid nitrogen to liquid hydrogen was small. The tensile strengths in liquid helium and hydrogen were nearly same and higher than those of smooth specimens. Different behavior of serration was observed between liquid helium and hydrogen, and between 304L and 316L steels. The reasons for these differences were discussed using computer simulation.