ITIzadyar Tamadon

Izadyar Tamadon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Izadyar Tamadon has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Prediction of human bone sawing forces from bone porosity, tool geometry, and machining parameters

    by Ali Ramezani, Stephanie McCreadie, Izadyar Tamadon, Michael W. van Emden, Gabrielle Tuijthof

  • Open Access

    Robotic Steerable Sheath for Left Atrial Appendage Occlusion

    by Nadia D’ALessandro, Selene Tognarelli, Izadyar Tamadon, Arianna Menciassi

    Atrial fibrillation, the most common cardiac arrhythmia, increases stroke risk due to clot formation in the left atrial appendage (LAA), where over 90% of thrombi originate. Left atrial appendage occlusion (LAAO) reduces this risk by mechanically sealing the LAA through an occluder. A key challenge is achieving coaxial alignment of the delivery sheath with the LAA, which varies in shape and orientation among subjects. Fixed-curve sheaths lack adaptability, while steerable sheaths improve alignment but still expose operators to fluoroscopic radiation. This study introduces the first robotic steerable delivery sheath (SDS) for LAAO. The SDS incorporates a notched Nitinol tip with two bending segments, providing three steering degrees of freedom, rotation, and translation, all controlled remotely through motorized actuation. Bench-top experiments confirmed superior dexterity and reachable workspace compared to existing delivery sheaths. A phantom-based validation with 17 users demonstrated successful teleoperated coaxial alignment with the LAA. Quantitative evaluation showed high accuracy, with mean angular and positional errors of 5.52$^{\circ }$ and 1.99 mm for the central axis, and 5.00$^{\circ }$ and 2.33 mm for implant depth, respectively. These findings support the feasibility of robotic-assisted LAAO, with the potential to enhance procedural precision while reducing radiation exposure for operators.


  • Open Access

    A Robotic Urinary Bladder Enabling Volume Monitoring and Assisted Micturition

    by Izadyar Tamadon, Michele Ibrahimi, Federica Semproni, Veronica Iacovacci, Arianna Menciassi

    The urinary bladder is considered a highly complex organ, capable not only of storing urine but also of sensing intra‐vesical volume and dynamically expanding and contracting. Consequently, fully replicating its functions following radical cystectomy remains a significant technological challenge. Hereinafter, an implantable robotic bladder is presented that can change shape and expand its internal volume up to 400 mL, based on the amount of urine collected from kidneys, and monitor the volume in real‐time. It can apply on‐demand mechanical compression to assist urination, by means of an origami‐designed enclosure, coupled to miniaturized mechatronic components. In vitro characterization in a human phantom is demonstrated, and volume monitoring is validated following a realistic filling routine. The tests demonstrate successful expansions for collecting urine, with an average volume reconstruction error of 8.4 ± 6.1 mL, and then 99% of the volume is voided in less than 2 min. The work paves the way for developing active robotic solutions and reproducing bladder functions in patients with cancer and organ removal or impairment.


  • Open Access

    The effect of human bone morphology on sawing forces

    by Ali Ramezani, Izadyar Tamadon, Quint Meinders, Michael van Emden, Nico Verdonschot, Gabrielle Tuijthof


  • Design and Hysteresis Compensation of a Telerobotic System for Transesophageal Echocardiography

    by Xiu Zhang, Izadyar Tamadon, Benjamín Ignacio Fortuño Jara, Vanessa Cannizzaro, Angela Peloso, Anna Bicchi, Andrea Aliverti, Emiliano Votta, Arianna Menciassi, Elena De Momi

    Transesophageal echocardiogram (TEE) plays an important role in diagnosing cardiac conditions such as valvular diseases and cardiac embolism, as well as guiding various cardiac interventions. It provides detailed cardiac imaging by inserting a probe into the esophagus, which offers an unobstructed view of the heart's chambers and valves. Addressing the operational challenges and health risks of the sonographer associated with the manual procedure, a novel robotic TEE system is developed to teleoperate the TEE probe across all four degrees of freedom (4-DoFs). This actuation device features an easily assembled design for post-operative cleaning and sanitization. Moreover, this system enhances the precision of tip bending angles through an optimization technique for offline calibration of the actuation plane. The hysteresis effect inherent in the tendon-driven mechanism is characterized and compensated using a free knots B-spline method and a look-up table. Experiments are conducted in a realistic human cardiovascular phantom for preclinical evaluation. Repeatability experiments validate the system's robustness. Furthermore, compared with the piecewise linear model, the proposed method achieves high accuracy with a median bending angle error of less than $\mathbf {0.8^\circ }$ . The results demonstrate the system's potential to significantly improve the autonomy of TEE procedures in cardiac diagnostic and therapeutic procedures.


  • Open Access

    A Multi-Sensorization Approach to Improve Safety in Transesophageal Echocardiography

    by Giovanni Faoro, Izadyar Tamadon, Selene Tognarelli, Arianna Menciassi

    Real-time 3D transesophageal echocardiography (RT-3D TEE) allows 3D visualization of patient heart and catheters without exposing patient and operators to ionizing radiations. Nonetheless, during such procedures esophageal injuries occur due to improper probe manipulation and probe overheating. To tackle these problems, we propose a multisensorization approach to provide information on probe pose and temperature throughout the procedure. Electromagnetic (EM) tracking is fused with inertial sensing thanks to a finite state machine integrating Extended and Incremental Kalman filters. This approach allows for a statistically significant improvement in static tracking with respect to standard EM, as reported by the Mann-Withney test. A novel sensor fault detection based on angular velocities discrepancy allows for robust tracking under different electromagnetic interferences, such as the one provided by ferro-, dia-and paramagnetic materials occupying the interventional room. Fiber optic technology is exploited for temperature estimation, taking advantage of its immunity to EM fields and the possibility of distributed sensing. Performances are compared with a commercial thermistor to guarantee feasibility and a root mean square error of 1.59 C is finally reported. We believe that these results demonstrate how sensing technologies can be integrated in TEE-guided surgical procedures to improve overall outcome and safety.


  • Open Access

    Semiautonomous Robotic Manipulator for Minimally Invasive Aortic Valve Replacement

    by Izadyar Tamadon, S. M. Hadi Sadati, Virginia Mamone, Vincenzo Ferrari, Christos Bergeles, Arianna Menciassi

    Aortic valve surgery is the preferred procedure for replacing a damaged valve with an artificial one. The ValveTech robotic platform comprises a flexible articulated manipulator and surgical interface supporting the effective delivery of an artificial valve by teleoperation and endoscopic vision. This article presents our recent work on force-perceptive, safe, semiautonomous navigation of the ValveTech platform prior to valve implantation. First, we present a force observer that transfers forces from the manipulator body and tip to a haptic interface. Second, we demonstrate how hybrid forward/inverse mechanics, together with endoscopic visual servoing, lead to autonomous valve positioning. Benchtop experiments and an artificial phantom quantify the performance of the developed robot controller and navigator. Valves can be autonomously delivered with a 2.0±0.5 mm position error and a minimal misalignment of 3.4±0.9°. The hybrid force/shape observer (FSO) algorithm was able to predict distributed external forces on the articulated manipulator body with an average error of 0.09 N. FSO can also estimate loads on the tip with an average accuracy of 3.3%. The presented system can lead to better patient care, delivery outcome, and surgeon comfort during aortic valve surgery, without requiring sensorization of the robot tip, and therefore obviating miniaturization constraints.


  • A Spring-Based Inductive Sensor for Soft and Flexible Robots

    by Sujit Kumar Sahu, Izadyar Tamadon, Benoit Rosa, Pierre Renaud, Arianna Menciassi

    The development of flexible and soft robots generates new needs in terms of instrumentation, as large encountered deformations require highly stretchable strain sensors. In this regard, we contribute to the adoption of inductive sensors by providing tools to model and exploit them and showing their relevance experimentally. First, strain estimation based on voltage measurement is proposed. Compared to direct inductance evaluation, the principle is easier to implement and opens the possibility to optimize the measurement performances by tuning the circuit components and interrogation frequency. The possibility of performing a single sensor calibration independently via the elongation mode during strain sensing is outlined. A detailed characterization is then performed, which shows that the sensor produces a low hysteresis of 0.1%, a precision in the order of 0.14%, and an accuracy of 0.9%. Finally, two proofs of concept are proposed: 1) the integration with a pneumatic artificial muscle (PAM) that demonstrates the added value of the sensor for a model-free precise control of a soft system and 2) the closed-loop control of a flexible bending manipulator using the inductive sensor. The performance in the closed-loop control is demonstrated, with a sensing element that is easy to integrate mechanically, strengthening its potential to be used as a structural element as well.


  • A fully implantable device for intraperitoneal drug delivery refilled by ingestible capsules

    by Veronica Iacovacci, Izadyar Tamadon, Emanuele Federico Kauffmann, Stefano Pane, Virginia Simoni, Leonardo Marziale, Michele Aragona, Luigi Cobuccio, Massimo Chiarugi, Paolo Dario, et al.

    Intraperitoneal insulin release is achieved using an implantable reservoir that is refilled with magnetic pills.


  • ValveTech: A Novel Robotic Approach for Minimally Invasive Aortic Valve Replacement

    by Izadyar Tamadon, Virginia Mamone, Yu Huan, Sara Condino, Claudio Quaglia, Vincenzo Ferrari, Mauro Ferrari, Arianna Menciassi

    Objective: Aortic valve disease is the most common heart disease in the elderly calling for replacement with an artificial valve. The presented surgical robot aims to provide a highly controllable instrument for efficient delivery of an artificial valve by the help of integrated endoscopic vision. Methods: A robot (called ValveTech), intended for minimally-invasive surgery (MIS) and consisting of a flexible cable driven manipulator, a passive arm, and a control unit has been designed and prototyped. The flexible manipulator has several features (e.g. stabilizing flaps, tiny cameras, dexterous introducer and custom cartridge) to help the proper valve placement. It provides 5 degrees of freedom for reaching the operative site via mini-thoracotomy; it adjusts the valve and expands it at the optimal position. The robot was evaluated by ten cardiac surgeons following a real surgical scenario in artificial chest simulator with an aortic mockup. Moreover, after each delivery, the expanded valve was evaluated objectively in comparison with the ideal position. Results: The robot performances were evaluated positively by surgeons. The trials resulted in faster delivery and an average misalignment distance of 3.8 mm along the aorta axis; 16.3 degrees rotational angle around aorta axis and 8.8 degrees misalignment of the valve commissure plane to the ideal plane were measured. Conclusion: The trials successfully proved the proposed system for valve delivery under endoscopic vision. Significance: The ValveTech robot can be an alternative solution for minimally invasive aortic valve surgery and improve the quality of the operation both for surgeons and patients.