Abstract
Aortic valve surgery is the preferred procedure for replacing a damaged valve with an artificial one. The ValveTech robotic platform comprises a flexible articulated manipulator and surgical interface supporting the effective delivery of an artificial valve by teleoperation and endoscopic vision. This article presents our recent work on force-perceptive, safe, semiautonomous navigation of the ValveTech platform prior to valve implantation. First, we present a force observer that transfers forces from the manipulator body and tip to a haptic interface. Second, we demonstrate how hybrid forward/inverse mechanics, together with endoscopic visual servoing, lead to autonomous valve positioning. Benchtop experiments and an artificial phantom quantify the performance of the developed robot controller and navigator. Valves can be autonomously delivered with a 2.0±0.5 mm position error and a minimal misalignment of 3.4±0.9°. The hybrid force/shape observer (FSO) algorithm was able to predict distributed external forces on the articulated manipulator body with an average error of 0.09 N. FSO can also estimate loads on the tip with an average accuracy of 3.3%. The presented system can lead to better patient care, delivery outcome, and surgeon comfort during aortic valve surgery, without requiring sensorization of the robot tip, and therefore obviating miniaturization constraints.Keywords
This publication has 41 references indexed in Scilit:
- A simple and accurate method for computer-aided transapical aortic valve replacementComputerized Medical Imaging and Graphics, 2014
- Current Status of Surgical Treatment for Aortic Valve StenosisJournal of Cardiac Surgery, 2014
- Diagnosis and Management of Valvular Aortic StenosisClinical Medicine Insights: Cardiology, 2014
- Sutureless Implantation of the Perceval S Aortic Valve Prosthesis Through Right Anterior MinithoracotomyThe Annals of Thoracic Surgery, 2013
- Sutureless aortic valve replacementCurrent Opinion in Cardiology, 2013
- Technical review of the da Vinci surgical telemanipulatorThe International Journal of Medical Robotics and Computer Assisted Surgery, 2012
- Image-Guided Transapical Aortic Valve Implantation Sensorless Tracking of Stenotic Valve Landmarks in Live Fluoroscopic ImagesInnovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2011
- Design and Kinematic Modeling of Constant Curvature Continuum Robots: A ReviewThe International Journal of Robotics Research, 2010
- Aortic dimensions and the risk of dissectionHeart, 2005
- Early experience with robotic aortic valve replacementEuropean Journal of Cardio-Thoracic Surgery, 2005