GFGisela De La Fuente-Cortes

Gisela De La Fuente-Cortes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gisela De La Fuente-Cortes has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An area-efficient 1st order noise shaping SAR using C-2C ladder DAC for biomedical applications

    by Mauricio Velázquez Díaz, Victor R. Gonzalez-Diaz, Gisela De La Fuente-Cortes, Guillermo Espinosa Flores-Verdad, Roberto S. Murphy-Arteaga


  • Open Access

    Theoretical and hardware-level precising in MASH 1-1-1 modulators with eliminable dither

    by Gisela De La Fuente-Cortes, Rosalba Perdomo-Cosme, Maria M. Perez-Torres, Victor R. Gonzalez-Diaz

    This manuscript explores Digital Delta-Sigma Modulators, commenting on the limitations of the eliminable dither in a Multi-stAge-noise-SHaping solution. The mathematical analysis in this work provides evidence, through a quantitative study, of the periodicity for eliminable dither and the Song and Park Multi-stAge-noise-SHaping modulators. The work presents the necessary considerations for the unexplored physical and digital synthesis implementation, commenting on the hardware limitations of the eliminable dither solution. The manuscript proposes a new dithering scheme with a feasible digital synthesis in a standard cell CMOS integrated circuit design. The solution uses an XOR-based signal feedback, extending the modulator’s periodicity with fourteen percent of additional hardware, representing a low-cost solution compared with similar systems.

  • Methodology for the Evaluation of Linear Response Microwave Sensors

    by Edel-Serafin Hernandez-Gomez, Jose-Luis Olvera-Cervantes, Andres-Fernando Plata-Galvis, Miguel Hernandez-Aguila, Gisela de la Fuente-Cortes

    Most microwave sensors establish a relationship between electrical parameters or dielectric properties with the property of interest of a sample using simple linear regression to make prediction. These do not implement the assumptions of linear regression and evaluate their quality in different ways, making fair comparison between regressions impossible. In this paper, a methodology is proposed to evaluate the assumptions. The assumption of anomalies is implemented with standardized and studentized residuals; the assumption of normality, with the Shapiro-Wilk test; the assumption of homoscedasticity, with the Breusch-Pagan test; the assumption of independence, with the Durbin-Watson test; and linearity, with the F test. This methodology includes the evaluation of the quality of the linear regression. The dynamic range is considered, such as the difference between the highest and the lowest value of the property of interest, the sensitivity using ordinary least squares, the resolution with analysis of variance and the accuracy with root mean squared error of cross-validation. The sl-regression-quality package is provided to perform the methodology using Python software. As an example, a resonator sensor is considered to determine the moisture content of meat. This methodology can be used for the fairest comparison between simple linear regressions of microwave sensors.


  • Open Access

    On-Chip CMOS Power Meter for Solar Cell Maximum Power Point Tracking

    by Gisela de la Fuente-Cortes, Luis Enrique Morales-Aguilar, Victor R. Gonzalez-Diaz, Selene Edith Maya-Rueda, Gerardo Mino-Aguilar, José Fermi Guerrero-Castellanos, Roberto S. Murphy-Arteaga

    This manuscript proposes and describes an on-chip power meter for photo voltaic power generation. The power meter provides the average measure for Maximum PowerPoint Tracking in DC-DC converters. The integrated chip power meter estimates the average current consumption using the DC-DC control system’s discrete-time nature. The power meter synthesis in a 65nm CMOS process explores the implementation with a simple structure and the theoretical considerations for real power measurement. The experimental results with 1.2Volts in bias conditions consume 5 percent of the overall DC-DC control system with the possible application into systems with alternative energy transducers.

  • Open Access

    A Non-Linear Successive Approximation Finite State Machine for ADCs with Robust Performance

    by Gisela De La Fuente-Cortes, Guillermo Espinosa Flores-Verdad, Alejandro Díaz-Méndez, Victor R. Gonzalez-Diaz

    This work presents the detailed design of a Successive Approximation Analog to Digital Data Converter (SAR ADC) using bulk 180 nm CMOS IC technology. The focus of the study is on replacing the typical Successive Approximation Register array with a Finite State Machine. This converter features a fully differential and bipolar architecture, which leads to the logic SAR nonlinear behavior. A novel digital control logic mitigates the conversion errors through the conditions in the previous logic states. The logic scheme, in combination with a robust continuous comparator, demonstrates tolerance to Process, Voltage, and Temperature variations. The architecture does not include calibration or additional redundancies in post-layout simulations to emphasize the exclusive benefits of the new SAR logic. The proposed SAR ADC achieves a 14.07 effective number of bits with 7.04 fJ/conversion step Walden figure of merit in biomedical applications.


  • Ischemic and non-ischemic heartbeat classifier for portable automatic detection systems

    by Gisela De La Fuente Cortes, Jose Alejandro Diaz-Mendez, Guillermo Espinosa Flores-Verdad, Victor Rodolfo Gonzalez-Diaz

    This article presents a new heartbeat classifieroriented to an automatic cardiac ischemia detection system aimedat the medical control of the population with cardiac disorders (ahigher risk group of severe COVID-19). The algorithm focuses ondistinguishing ischemic heartbeats from non-ischemic based onmethods and techniques proposed by medical experts in cardiacischemia diagnoses. The proposed algorithm was tested with 80 electrocardiogram recordings obtained from the Long-term STdatabase of Physionet with a 100,112 heartbeat population. Theheartbeat population contains different types of non-ischemiccases. The algorithm exhibits a sensitivity of 98.7 percent andspecificity of 97.23 percent. The digital synthesis, in a 180nmCMOS process with a dynamic power consumption of 13.15 microWatt demanding an area of 490x400 micrometers, attests to thealgorithm benefits.

  • On-Chip Fuzzy Logic Synthesis of a New Ischemic and Non-Ischemic Heartbeat Classifier

    by Gisela De La Fuente-Cortes, A. Diaz-Mendez, Guillermo Espinosa Flores-Verdad, Victor R. Gonzalez-Diaz

    This brief presents a new ischemic and non-ischemic heartbeat classifier, which is highly synthesizable for on-chip applications. The classifier consists of an algorithm analyzing the electrocardiogram (ECG) shape to distinguish ischemia. It emulates medical expertise in cardiac ischemia diagnosis using a digital fuzzy logic system. The proposed fuzzy sets obtain information to classify ischemic and non-ischemic heartbeats, helping in discarding false positives. The work presents the physical implementation and experimental results on-chip in a CMOS 180nm process. The algorithm tests 20 electrocardiogram recordings from the Long-Term ST database in Physionet, verifying the method. The experimental results, with an 8-bit resolution, exhibit a sensitivity (Se) of 96.43 percent and specificity (Sp) of 96.88 percent with a (300$\times$ 325) squared microns digital circuit. The implementation of the algorithm, with 14-bit resolution, shows a performance increase in (Se) of 99.03 percent and specificity (Sp) of 99.08 percent, solely using two ECG descriptors.