Guillermo Espinosa Flores-Verdad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Guillermo Espinosa Flores-Verdad has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Victor Rodolfo Gonzalez Diaz
Autonomous University of Puebla (BUAP)
7 shared publications - Gisela De La Fuente-Cortes
Faculty of Electronics Sciences, Benemérita Universidad Autónoma de Puebla, Puebla, México
4 shared publications - Jose Alejandro Diaz-Mendez
Electronics Coordination, National Institute for Astrophysics Optics and Electronics (INAOE), Puebla 72840, Mexico
3 shared publications - Hayde Peregrina-Barreto
Instituto Nacional de Astrofísica, Óptica y Electrónica, Luis Enrique Erro 1, Santa Maria Tonantzintla, San Andres Cholula 72840, Mexico
2 shared publications - Joseph Herbert Mitchell-Moreno
Electronics Department, Instituto Nacional de Astrofisica, Optica y Electronica, San Andres Cholula, Mexico
2 shared publications - Leopoldo Altamirano-Robles
Instituto Nacional de Astrofísica, Optica y Electrönica
2 shared publications
Latest Publications
- 1 June 2026
- Published by Elsevier in Integration
- Vol. 110
A novel switched-capacitor two-phase single-amplifier 2nd-order Sigma-Delta modulator architecture for area-efficient Zoom ADCs
- 1 June 2026
- Published by Elsevier in Integration
- Vol. 110
A novel switched-capacitor two-phase single-amplifier 2nd-order Sigma-Delta modulator architecture for area-efficient Zoom ADCs
- Open Access
- 20 November 2025
- Published by Elsevier in Integration
- Vol. 107
An area-efficient 1st order noise shaping SAR using C-2C ladder DAC for biomedical applications
- 20 November 2025
- Published by Elsevier in Integration
- Vol. 107
Open AccessAn area-efficient 1st order noise shaping SAR using C-2C ladder DAC for biomedical applications
- Open Access
Lure Monitoring for Mediterranean Fruit Fly Traps Using Air Quality Sensors
Effective pest population monitoring is crucial in precision agriculture, which integrates various technologies and data analysis techniques for enhanced decision-making. This study introduces a novel approach for monitoring lures in traps targeting the Mediterranean fruit fly, utilizing air quality sensors to detect total volatile organic compounds (TVOC) and equivalent carbon dioxide (eCO2). Our results indicate that air quality sensors, specifically the SGP30 and ENS160 models, can reliably detect the presence of lures, reducing the need for frequent physical trap inspections and associated maintenance costs. The ENS160 sensor demonstrated superior performance, with stable detection capabilities at a predefined distance from the lure, suggesting its potential for integration into smart trap designs. This is the first study to apply TVOC and eCO2 sensors in this context, paving the way for more efficient and cost-effective pest monitoring solutions in smart agriculture environments.
Open AccessLure Monitoring for Mediterranean Fruit Fly Traps Using Air Quality Sensors
Effective pest population monitoring is crucial in precision agriculture, which integrates various technologies and data analysis techniques for enhanced decision-making. This study introduces a novel approach for monitoring lures in traps targeting the Mediterranean fruit fly, utilizing air quality sensors to detect total volatile organic compounds (TVOC) and equivalent carbon dioxide (eCO2). Our results indicate that air quality sensors, specifically the SGP30 and ENS160 models, can reliably detect the presence of lures, reducing the need for frequent physical trap inspections and associated maintenance costs. The ENS160 sensor demonstrated superior performance, with stable detection capabilities at a predefined distance from the lure, suggesting its potential for integration into smart trap designs. This is the first study to apply TVOC and eCO2 sensors in this context, paving the way for more efficient and cost-effective pest monitoring solutions in smart agriculture environments.
- Open Access
- 13 July 2024
- Published by MDPI AG in Electronics
- Vol. 13 (14) , 2756
A Non-Linear Successive Approximation Finite State Machine for ADCs with Robust Performance
This work presents the detailed design of a Successive Approximation Analog to Digital Data Converter (SAR ADC) using bulk 180 nm CMOS IC technology. The focus of the study is on replacing the typical Successive Approximation Register array with a Finite State Machine. This converter features a fully differential and bipolar architecture, which leads to the logic SAR nonlinear behavior. A novel digital control logic mitigates the conversion errors through the conditions in the previous logic states. The logic scheme, in combination with a robust continuous comparator, demonstrates tolerance to Process, Voltage, and Temperature variations. The architecture does not include calibration or additional redundancies in post-layout simulations to emphasize the exclusive benefits of the new SAR logic. The proposed SAR ADC achieves a 14.07 effective number of bits with 7.04 fJ/conversion step Walden figure of merit in biomedical applications.
- 13 July 2024
- Published by MDPI AG in Electronics
- Vol. 13 (14) , 2756
Open AccessA Non-Linear Successive Approximation Finite State Machine for ADCs with Robust Performance
This work presents the detailed design of a Successive Approximation Analog to Digital Data Converter (SAR ADC) using bulk 180 nm CMOS IC technology. The focus of the study is on replacing the typical Successive Approximation Register array with a Finite State Machine. This converter features a fully differential and bipolar architecture, which leads to the logic SAR nonlinear behavior. A novel digital control logic mitigates the conversion errors through the conditions in the previous logic states. The logic scheme, in combination with a robust continuous comparator, demonstrates tolerance to Process, Voltage, and Temperature variations. The architecture does not include calibration or additional redundancies in post-layout simulations to emphasize the exclusive benefits of the new SAR logic. The proposed SAR ADC achieves a 14.07 effective number of bits with 7.04 fJ/conversion step Walden figure of merit in biomedical applications.
- 6 February 2024
- Published by Taylor & Francis
- p. 116-134
Memristor-Based Ring Oscillators as Alternative for Reliable Physical Unclonable Functions
With the recent advances in the study of the memristor as the fourth fundamental element of circuit theory, wide amount of opportunities has emerged in manufacturing and modeling of the device, as well as developing applications of memristive circuits. This work emphasizes the results obtained from a full-factorial experiment to study the variability present in the frequencies of the analog hardware, in addition a charge-controlled memristor model is applied for Hardware Security “HS” under the premise that the parameters of the memristor allow to establish its electrical characteristics and therefore the response of the basic cells for HS. The approach is focused on using memristors in physical unclonable functions “PUFs” based on ring oscillators “RO” whose oscillation frequency is set by the memristors that act as the key control factor. The performance of the PUF response is determined by using various metrics for HS commonly accepted by the scientific community, such as: uniqueness, uniformity and bit aliasing. In this work, several analyzes have been carried out in order to demonstrate that memristive PUFs exhibit excellent metrics under diverse conditions of complexity of the systems.
- 6 February 2024
- Published by Taylor & Francis
- p. 116-134
Memristor-Based Ring Oscillators as Alternative for Reliable Physical Unclonable Functions
With the recent advances in the study of the memristor as the fourth fundamental element of circuit theory, wide amount of opportunities has emerged in manufacturing and modeling of the device, as well as developing applications of memristive circuits. This work emphasizes the results obtained from a full-factorial experiment to study the variability present in the frequencies of the analog hardware, in addition a charge-controlled memristor model is applied for Hardware Security “HS” under the premise that the parameters of the memristor allow to establish its electrical characteristics and therefore the response of the basic cells for HS. The approach is focused on using memristors in physical unclonable functions “PUFs” based on ring oscillators “RO” whose oscillation frequency is set by the memristors that act as the key control factor. The performance of the PUF response is determined by using various metrics for HS commonly accepted by the scientific community, such as: uniqueness, uniformity and bit aliasing. In this work, several analyzes have been carried out in order to demonstrate that memristive PUFs exhibit excellent metrics under diverse conditions of complexity of the systems.
- Open Access
Shadow Effect for Small Insect Detection by W-Band Pulsed Radar
In radar entomology, one primary challenge is detecting small species (smaller than 5 cm) since these tiny insects reflect radiation that can be poorly observable and, therefore, difficult to interpret. After a literature search on radar entomology, this research found few works where it has been possible to sense insects with dimensions smaller than 5 cm using radars. This paper describes different methodologies to detect Mediterranean fruit flies with 5–6 mm sizes using a pulsed W-band radar and presents the experimental results that validate the procedures. The article’s main contribution is the successful detection of Mediterranean fruit flies employing the shadow effect on the backscattered radar signal, achieving an 11% difference in received power when flies are present. So far, according to the information available and the literature search, this work is the first to detect small insects less than 1 cm long using a pulsed radar in W-Band. The results show that the proposed shadow effect is a viable alternative to the current sensors used in smart traps, as it allows not only detection but also counting the number of insects in the trap.
Open AccessShadow Effect for Small Insect Detection by W-Band Pulsed Radar
In radar entomology, one primary challenge is detecting small species (smaller than 5 cm) since these tiny insects reflect radiation that can be poorly observable and, therefore, difficult to interpret. After a literature search on radar entomology, this research found few works where it has been possible to sense insects with dimensions smaller than 5 cm using radars. This paper describes different methodologies to detect Mediterranean fruit flies with 5–6 mm sizes using a pulsed W-band radar and presents the experimental results that validate the procedures. The article’s main contribution is the successful detection of Mediterranean fruit flies employing the shadow effect on the backscattered radar signal, achieving an 11% difference in received power when flies are present. So far, according to the information available and the literature search, this work is the first to detect small insects less than 1 cm long using a pulsed radar in W-Band. The results show that the proposed shadow effect is a viable alternative to the current sensors used in smart traps, as it allows not only detection but also counting the number of insects in the trap.
- 15 September 2023
- Published by Springer Nature in Journal of Electronic Testing
- Vol. 39 (5-6) , 611-620
A Low Bit Instability CMOS PUF Based on Current Mirrors and WTA Cells
- 15 September 2023
- Published by Springer Nature in Journal of Electronic Testing
- Vol. 39 (5-6) , 611-620
A Low Bit Instability CMOS PUF Based on Current Mirrors and WTA Cells
- 10 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 19 (6) , 952-960
Ischemic and non-ischemic heartbeat classifier for portable automatic detection systems
This article presents a new heartbeat classifieroriented to an automatic cardiac ischemia detection system aimedat the medical control of the population with cardiac disorders (ahigher risk group of severe COVID-19). The algorithm focuses ondistinguishing ischemic heartbeats from non-ischemic based onmethods and techniques proposed by medical experts in cardiacischemia diagnoses. The proposed algorithm was tested with 80 electrocardiogram recordings obtained from the Long-term STdatabase of Physionet with a 100,112 heartbeat population. Theheartbeat population contains different types of non-ischemiccases. The algorithm exhibits a sensitivity of 98.7 percent andspecificity of 97.23 percent. The digital synthesis, in a 180nmCMOS process with a dynamic power consumption of 13.15 microWatt demanding an area of 490x400 micrometers, attests to thealgorithm benefits.
- 10 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 19 (6) , 952-960
Ischemic and non-ischemic heartbeat classifier for portable automatic detection systems
This article presents a new heartbeat classifieroriented to an automatic cardiac ischemia detection system aimedat the medical control of the population with cardiac disorders (ahigher risk group of severe COVID-19). The algorithm focuses ondistinguishing ischemic heartbeats from non-ischemic based onmethods and techniques proposed by medical experts in cardiacischemia diagnoses. The proposed algorithm was tested with 80 electrocardiogram recordings obtained from the Long-term STdatabase of Physionet with a 100,112 heartbeat population. Theheartbeat population contains different types of non-ischemiccases. The algorithm exhibits a sensitivity of 98.7 percent andspecificity of 97.23 percent. The digital synthesis, in a 180nmCMOS process with a dynamic power consumption of 13.15 microWatt demanding an area of 490x400 micrometers, attests to thealgorithm benefits.
- 5 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 19 (01) , 83-88
Self Calibrated Readout Frontend for Capacitive Biosensors
In capacitive transducers area, the fabrication process variations in the parameters that define the nominal capacitance induce mismatch between the fabricated transductors; and in order to minimize it a new frontend architecture, that does not need a reference sensor for calibration, is presented here. The proposed system works with a DC reference signal, instead of an AC signal as most of the reported works. A readout system using the proposed architecture was designed in a 180nm CMOS technology for a particular capacitive microfluidic bio-sensor to detect E.Coli bacteria. The nominal sensor has a capacitance range that goes from 192pF to 122 pF for a 0-100,000 UFC/ml concentration range.
- 5 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 19 (01) , 83-88
Self Calibrated Readout Frontend for Capacitive Biosensors
In capacitive transducers area, the fabrication process variations in the parameters that define the nominal capacitance induce mismatch between the fabricated transductors; and in order to minimize it a new frontend architecture, that does not need a reference sensor for calibration, is presented here. The proposed system works with a DC reference signal, instead of an AC signal as most of the reported works. A readout system using the proposed architecture was designed in a 180nm CMOS technology for a particular capacitive microfluidic bio-sensor to detect E.Coli bacteria. The nominal sensor has a capacitance range that goes from 192pF to 122 pF for a 0-100,000 UFC/ml concentration range.
- 7 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 68 (1) , 476-480
On-Chip Fuzzy Logic Synthesis of a New Ischemic and Non-Ischemic Heartbeat Classifier
This brief presents a new ischemic and non-ischemic heartbeat classifier, which is highly synthesizable for on-chip applications. The classifier consists of an algorithm analyzing the electrocardiogram (ECG) shape to distinguish ischemia. It emulates medical expertise in cardiac ischemia diagnosis using a digital fuzzy logic system. The proposed fuzzy sets obtain information to classify ischemic and non-ischemic heartbeats, helping in discarding false positives. The work presents the physical implementation and experimental results on-chip in a CMOS 180nm process. The algorithm tests 20 electrocardiogram recordings from the Long-Term ST database in Physionet, verifying the method. The experimental results, with an 8-bit resolution, exhibit a sensitivity (Se) of 96.43 percent and specificity (Sp) of 96.88 percent with a (300$\times$ 325) squared microns digital circuit. The implementation of the algorithm, with 14-bit resolution, shows a performance increase in (Se) of 99.03 percent and specificity (Sp) of 99.08 percent, solely using two ECG descriptors.
- 7 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 68 (1) , 476-480
On-Chip Fuzzy Logic Synthesis of a New Ischemic and Non-Ischemic Heartbeat Classifier
This brief presents a new ischemic and non-ischemic heartbeat classifier, which is highly synthesizable for on-chip applications. The classifier consists of an algorithm analyzing the electrocardiogram (ECG) shape to distinguish ischemia. It emulates medical expertise in cardiac ischemia diagnosis using a digital fuzzy logic system. The proposed fuzzy sets obtain information to classify ischemic and non-ischemic heartbeats, helping in discarding false positives. The work presents the physical implementation and experimental results on-chip in a CMOS 180nm process. The algorithm tests 20 electrocardiogram recordings from the Long-Term ST database in Physionet, verifying the method. The experimental results, with an 8-bit resolution, exhibit a sensitivity (Se) of 96.43 percent and specificity (Sp) of 96.88 percent with a (300$\times$ 325) squared microns digital circuit. The implementation of the algorithm, with 14-bit resolution, shows a performance increase in (Se) of 99.03 percent and specificity (Sp) of 99.08 percent, solely using two ECG descriptors.