Hassan Jafari Mosleh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hassan Jafari Mosleh has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Marc A. Rosen
Faculty of Engineering and Applied Science University of Ontario Institute of Technology Oshawa ON Canada
1 shared publicationMaryam Abbasi Kamazani
Department of Mechanical Engineering K. N. Toosi University of Technology Tehran Iran
1 shared publication- Maryam Karami
Department of Mechanical Engineering, Faculty of Engineering, Kharazmi University, Tehran, Iran
1 shared publication Omid Mohammadi
Department of Mechanical Engineering Sharif University of Technology Tehran Iran
1 shared publication- Peyman Pourmoghadam
Department of Renewable Energies and Environment Faculty of New Sciences and Technologies, University of Tehran Tehran Iran
1 shared publication Pooria Behnam
School of Engineering Edith Cowan University Perth WA Australia
1 shared publication
Latest Publications
- Open Access
- 12 January 2022
- Published by Wiley in Energy Science & Engineering
- Vol. 10 (3) , 707-725
Dynamic simulation of a solar ejector‐based trigeneration system using TRNSYS‐EES co‐simulator
In this paper, a new configuration of a solar combined cooling, heating, and power (CCHP) system is proposed to recover the waste thermal energy of a steam power plant, which provides the cooling and heating needs of an apartment complex located in Tehran. The required energy of the system is supplied by the parabolic trough solar collectors (PTCs) and, if necessary, an auxiliary heater is also used. An ejector refrigeration cycle (ERC) and a steam Rankine cycle are used for cooling and power generation, respectively. The cycle is dynamically modeled over a year using a TRNSYS‐EES co‐simulator. It is found that the highest Rankine cycle efficiency is obtained in the cold months (January) because of the decrease of turbine backpressure. With increasing the turbine inlet temperature from 190 to 210°C, the Rankine cycle and the overall cycle efficiencies increased about 1% and 2%, respectively. The maximum cooling, heating, and power generation, as well as the maximum solar fraction, are obtained at the turbine inlet temperatures of 210°C, which are 185.46, 598.65, 680.49 kW, and 70%, respectively. The annual overall performance and the solar fraction of the proposed CCHP system are 32.5% and 9.5%, respectively, based on 3000 m2 collector aperture area. The exergy analysis indicated that the maximum annual exergy destruction is related to the solar collectors, which have comprised 27% of the total exergy destruction. In addition, the yearly exergy efficiency of the proposed system is 39.9%.
- 12 January 2022
- Published by Wiley in Energy Science & Engineering
- Vol. 10 (3) , 707-725
Open AccessDynamic simulation of a solar ejector‐based trigeneration system using TRNSYS‐EES co‐simulator
In this paper, a new configuration of a solar combined cooling, heating, and power (CCHP) system is proposed to recover the waste thermal energy of a steam power plant, which provides the cooling and heating needs of an apartment complex located in Tehran. The required energy of the system is supplied by the parabolic trough solar collectors (PTCs) and, if necessary, an auxiliary heater is also used. An ejector refrigeration cycle (ERC) and a steam Rankine cycle are used for cooling and power generation, respectively. The cycle is dynamically modeled over a year using a TRNSYS‐EES co‐simulator. It is found that the highest Rankine cycle efficiency is obtained in the cold months (January) because of the decrease of turbine backpressure. With increasing the turbine inlet temperature from 190 to 210°C, the Rankine cycle and the overall cycle efficiencies increased about 1% and 2%, respectively. The maximum cooling, heating, and power generation, as well as the maximum solar fraction, are obtained at the turbine inlet temperatures of 210°C, which are 185.46, 598.65, 680.49 kW, and 70%, respectively. The annual overall performance and the solar fraction of the proposed CCHP system are 32.5% and 9.5%, respectively, based on 3000 m2 collector aperture area. The exergy analysis indicated that the maximum annual exergy destruction is related to the solar collectors, which have comprised 27% of the total exergy destruction. In addition, the yearly exergy efficiency of the proposed system is 39.9%.
- Open Access
- 22 December 2020
- Published by Wiley in Energy Science & Engineering
- Vol. 9 (5) , 724-742
A comprehensive comparative investigation on solar heating and cooling technologies from a thermo‐economic viewpoint—A dynamic simulation
The yearly thermo‐economic performance is dynamically investigated for three solar heating and cooling systems: solar heating and absorption cooling (SHAC), solar heating and ejector cooling (SHEC), and heating and solar vapor compression cooling (HSVC). First, the effects of important design parameters on the thermo‐economic performance of the systems to supply the heating and cooling loads of the building are evaluated. The systems are parametrically analyzed with the weather conditions of Tehran, Iran. The results show that the life cycle costs (LCC) of the SHAC and HSVC systems are alike and much lower than those of the SHEC system. The HSVC system exhibits the best performance from exergetic and solar fraction viewpoints. The comparative analysis shows that the energy efficiencies of the SHAC and SHEC systems are higher in colder climatic conditions. However, the collector efficiency of the HSVC system declines in colder climates, mainly due to the lower solar intensities relative to in hotter climates. Further, the solar fraction of the SHAC system is higher than the SHEC technology under all climatic conditions. Moreover, higher values of solar fractions are obtained under colder weather conditions for the SHEC and HSVC systems. The best economic performance is observed for the SHAC and HSVC technologies, having significantly lower LCCs than the SHEC system. These lower LCCs under colder climatic conditions are due to the lower cost of supplying the heating load compared to the cooling load. Furthermore, all systems exhibit enhanced exergetic performance in colder weather conditions. The yearly thermo‐economic performance is dynamically investigated for three solar heating and cooling systems: SHAC, SHEC, and HSVC. In addition, the effects of important design parameters on the thermo‐economic performance of the systems to supply the heating and cooling loads of the building are evaluated.
- 22 December 2020
- Published by Wiley in Energy Science & Engineering
- Vol. 9 (5) , 724-742
Open AccessA comprehensive comparative investigation on solar heating and cooling technologies from a thermo‐economic viewpoint—A dynamic simulation
The yearly thermo‐economic performance is dynamically investigated for three solar heating and cooling systems: solar heating and absorption cooling (SHAC), solar heating and ejector cooling (SHEC), and heating and solar vapor compression cooling (HSVC). First, the effects of important design parameters on the thermo‐economic performance of the systems to supply the heating and cooling loads of the building are evaluated. The systems are parametrically analyzed with the weather conditions of Tehran, Iran. The results show that the life cycle costs (LCC) of the SHAC and HSVC systems are alike and much lower than those of the SHEC system. The HSVC system exhibits the best performance from exergetic and solar fraction viewpoints. The comparative analysis shows that the energy efficiencies of the SHAC and SHEC systems are higher in colder climatic conditions. However, the collector efficiency of the HSVC system declines in colder climates, mainly due to the lower solar intensities relative to in hotter climates. Further, the solar fraction of the SHAC system is higher than the SHEC technology under all climatic conditions. Moreover, higher values of solar fractions are obtained under colder weather conditions for the SHEC and HSVC systems. The best economic performance is observed for the SHAC and HSVC technologies, having significantly lower LCCs than the SHEC system. These lower LCCs under colder climatic conditions are due to the lower cost of supplying the heating load compared to the cooling load. Furthermore, all systems exhibit enhanced exergetic performance in colder weather conditions. The yearly thermo‐economic performance is dynamically investigated for three solar heating and cooling systems: SHAC, SHEC, and HSVC. In addition, the effects of important design parameters on the thermo‐economic performance of the systems to supply the heating and cooling loads of the building are evaluated.