HMHassan Jafari Mosleh

Hassan Jafari Mosleh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hassan Jafari Mosleh has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Marc A. Rosen

    Faculty of Engineering and Applied Science University of Ontario Institute of Technology Oshawa ON Canada

    1 shared publication
  • Maryam Abbasi Kamazani

    Department of Mechanical Engineering K. N. Toosi University of Technology Tehran Iran

    1 shared publication
  • Maryam Karami

    Department of Mechanical Engineering, Faculty of Engineering, Kharazmi University, Tehran, Iran

    1 shared publication
  • Omid Mohammadi

    Department of Mechanical Engineering Sharif University of Technology Tehran Iran

    1 shared publication
  • Peyman Pourmoghadam

    Department of Renewable Energies and Environment Faculty of New Sciences and Technologies, University of Tehran Tehran Iran

    1 shared publication
  • Pooria Behnam

    School of Engineering Edith Cowan University Perth WA Australia

    1 shared publication

Latest Publications

  • Open Access

    Dynamic simulation of a solar ejector‐based trigeneration system using TRNSYS‐EES co‐simulator

    by Peyman Pourmoghadam, Hassan Jafari Mosleh, Maryam Karami

    In this paper, a new configuration of a solar combined cooling, heating, and power (CCHP) system is proposed to recover the waste thermal energy of a steam power plant, which provides the cooling and heating needs of an apartment complex located in Tehran. The required energy of the system is supplied by the parabolic trough solar collectors (PTCs) and, if necessary, an auxiliary heater is also used. An ejector refrigeration cycle (ERC) and a steam Rankine cycle are used for cooling and power generation, respectively. The cycle is dynamically modeled over a year using a TRNSYS‐EES co‐simulator. It is found that the highest Rankine cycle efficiency is obtained in the cold months (January) because of the decrease of turbine backpressure. With increasing the turbine inlet temperature from 190 to 210°C, the Rankine cycle and the overall cycle efficiencies increased about 1% and 2%, respectively. The maximum cooling, heating, and power generation, as well as the maximum solar fraction, are obtained at the turbine inlet temperatures of 210°C, which are 185.46, 598.65, 680.49 kW, and 70%, respectively. The annual overall performance and the solar fraction of the proposed CCHP system are 32.5% and 9.5%, respectively, based on 3000 m2 collector aperture area. The exergy analysis indicated that the maximum annual exergy destruction is related to the solar collectors, which have comprised 27% of the total exergy destruction. In addition, the yearly exergy efficiency of the proposed system is 39.9%.


  • Open Access

    A comprehensive comparative investigation on solar heating and cooling technologies from a thermo‐economic viewpoint—A dynamic simulation

    by Hassan Jafari Mosleh, Pooria Behnam, Maryam Abbasi Kamazani, Omid Mohammadi, Soheil Kavian, Pouria Ahmadi, Marc A. Rosen

    The yearly thermo‐economic performance is dynamically investigated for three solar heating and cooling systems: solar heating and absorption cooling (SHAC), solar heating and ejector cooling (SHEC), and heating and solar vapor compression cooling (HSVC). First, the effects of important design parameters on the thermo‐economic performance of the systems to supply the heating and cooling loads of the building are evaluated. The systems are parametrically analyzed with the weather conditions of Tehran, Iran. The results show that the life cycle costs (LCC) of the SHAC and HSVC systems are alike and much lower than those of the SHEC system. The HSVC system exhibits the best performance from exergetic and solar fraction viewpoints. The comparative analysis shows that the energy efficiencies of the SHAC and SHEC systems are higher in colder climatic conditions. However, the collector efficiency of the HSVC system declines in colder climates, mainly due to the lower solar intensities relative to in hotter climates. Further, the solar fraction of the SHAC system is higher than the SHEC technology under all climatic conditions. Moreover, higher values of solar fractions are obtained under colder weather conditions for the SHEC and HSVC systems. The best economic performance is observed for the SHAC and HSVC technologies, having significantly lower LCCs than the SHEC system. These lower LCCs under colder climatic conditions are due to the lower cost of supplying the heating load compared to the cooling load. Furthermore, all systems exhibit enhanced exergetic performance in colder weather conditions. The yearly thermo‐economic performance is dynamically investigated for three solar heating and cooling systems: SHAC, SHEC, and HSVC. In addition, the effects of important design parameters on the thermo‐economic performance of the systems to supply the heating and cooling loads of the building are evaluated.