Pengyu Fu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pengyu Fu has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Jin Wang
The Ohio State University
5 shared publications - Xuebao Li
North China Electric Power University
4 shared publications Zhibin Zhao
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University Beijing 102206 People's Republic of China
3 shared publications- Boxue Hu
Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH, USA
2 shared publications Juchen Yang
Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH, USA
2 shared publicationsShenyang Mo
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources North China Electric Power University Beijing 102206 People's Republic of China
2 shared publications
Latest Publications
- 17 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (8) , 13569-13579
1.5-kV 1.5-kW DC Power Transmission With MMC-Based High-Gain Isolated DC/DC Converters for Lunar Surface Applications
A power transmission and energy storage system are essential to support the microgrid at the Moon's South Pole. Key challenges include minimizing system mass and ensuring survivability under extreme lunar conditions, specifically: (1) radiation hardness, (2) vacuum compatibility, and (3) cryogenic operation. This study proposes a 3-km, 1.5-kV, 1.5-kW DC power transmission and conversion system employing two modular multilevel converter (MMC)-based bidirectional high-gain isolated DC/DC converters, with multi-winding high-frequency transformers, for voltage step-up and step-down operation. These converters achieve a high voltage conversion ratio and exhibit low device voltage stress, which mitigates ion-radiation-induced single-event burnout (SEB) in Gallium Nitride (GaN) devices. Furthermore, operating the transformer at low voltage and high frequency reduces its size and mass. This paper presents the selection and evaluation of key components under lunar environmental constraints, and discusses gate driver and transformer design. To ensure thermal performance under vacuum condition, the system employs radiation-based cooling to offset the lack of air convection. The converters have been validated under full voltage and power in vacuum and cryogenic conditions. The total system mass including the power conversion, energy storage and 3-km transmission lines remains below 150 kg.
- 17 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (8) , 13569-13579
1.5-kV 1.5-kW DC Power Transmission With MMC-Based High-Gain Isolated DC/DC Converters for Lunar Surface Applications
A power transmission and energy storage system are essential to support the microgrid at the Moon's South Pole. Key challenges include minimizing system mass and ensuring survivability under extreme lunar conditions, specifically: (1) radiation hardness, (2) vacuum compatibility, and (3) cryogenic operation. This study proposes a 3-km, 1.5-kV, 1.5-kW DC power transmission and conversion system employing two modular multilevel converter (MMC)-based bidirectional high-gain isolated DC/DC converters, with multi-winding high-frequency transformers, for voltage step-up and step-down operation. These converters achieve a high voltage conversion ratio and exhibit low device voltage stress, which mitigates ion-radiation-induced single-event burnout (SEB) in Gallium Nitride (GaN) devices. Furthermore, operating the transformer at low voltage and high frequency reduces its size and mass. This paper presents the selection and evaluation of key components under lunar environmental constraints, and discusses gate driver and transformer design. To ensure thermal performance under vacuum condition, the system employs radiation-based cooling to offset the lack of air convection. The converters have been validated under full voltage and power in vacuum and cryogenic conditions. The total system mass including the power conversion, energy storage and 3-km transmission lines remains below 150 kg.
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (12) , 15748-15756
Insulation Capability at 10 kV, >300 V/ns of a Nonlinear Resistive Polymer Nanocomposite Field-Grading Coating in a 15-kV Silicon Carbide Module
Emerging medium-voltage silicon carbide devices offer the potential to achieve more efficient and compact power electronics for grid-tied applications. However, the lack of an effective insulation solution for packaging the devices has slowed their widespread adoption. Recently, a nonlinear resistive polymer nanocomposite coating has been introduced to enhance the insulation by reducing localized electric field stress inside the modules. The purpose of this study is to evaluate the insulation capability of the polymer nanocomposite under high dv/dt . Half-bridge modules of 15-kV silicon carbide devices were packaged with the nanocomposite coating at the triple points on the module substrate. All the modules were tested free of partial discharge at 20 kV for 1 min. One module underwent a repetitive double-pulse test at 10 kV, 2 A and was switching at a peak dv/dt > 300 V/ns. These findings further support the coating's potential as a viable practical solution to the insulation challenge of medium-voltage power modules.
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (12) , 15748-15756
Insulation Capability at 10 kV, >300 V/ns of a Nonlinear Resistive Polymer Nanocomposite Field-Grading Coating in a 15-kV Silicon Carbide Module
Emerging medium-voltage silicon carbide devices offer the potential to achieve more efficient and compact power electronics for grid-tied applications. However, the lack of an effective insulation solution for packaging the devices has slowed their widespread adoption. Recently, a nonlinear resistive polymer nanocomposite coating has been introduced to enhance the insulation by reducing localized electric field stress inside the modules. The purpose of this study is to evaluate the insulation capability of the polymer nanocomposite under high dv/dt . Half-bridge modules of 15-kV silicon carbide devices were packaged with the nanocomposite coating at the triple points on the module substrate. All the modules were tested free of partial discharge at 20 kV for 1 min. One module underwent a repetitive double-pulse test at 10 kV, 2 A and was switching at a peak dv/dt > 300 V/ns. These findings further support the coating's potential as a viable practical solution to the insulation challenge of medium-voltage power modules.
- 25 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (4) , 4426-4437
A Quasi-Switched-Capacitor-Based Bidirectional Isolated DC–DC Converter With High Voltage Conversion Ratio and Reduced Current Ripple
This research introduces a unique bidirectional dc–dc converter specifically developed for energy storage applications. The proposed circuit topology exhibits a high voltage conversion ratio and a reduced current ripple. On the transformer primary side, a quasi-switched-capacitor (QSC) circuit mitigates voltage stress on switching devices and achieves a 3:1 voltage step-down ratio. The proposed transformer-interleaved circuit on the secondary side features the 2:1 voltage conversion ratio and minimizes the battery current ripple without adding extra switching or magnetic components. The 6:1 voltage conversion contributes to a simpler winding structure, smaller transformer size, and lower transformer loss in high voltage gain application. Furthermore, the reduced current ripple leads to lower battery heat generation and smaller filter bank capacitance, making it suitable for high-density design. The implementation of phase shift control, similar to the dual-active-bridge circuit, serves to regulate the circuit's transferred power. A 1-kW, 300-kHz, 380–420-/20–33-V GaN-based circuit prototype is developed and tested. The tested peak efficiency is 98.5% with a power density of 30.42 W/in 3 .
- 25 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (4) , 4426-4437
A Quasi-Switched-Capacitor-Based Bidirectional Isolated DC–DC Converter With High Voltage Conversion Ratio and Reduced Current Ripple
This research introduces a unique bidirectional dc–dc converter specifically developed for energy storage applications. The proposed circuit topology exhibits a high voltage conversion ratio and a reduced current ripple. On the transformer primary side, a quasi-switched-capacitor (QSC) circuit mitigates voltage stress on switching devices and achieves a 3:1 voltage step-down ratio. The proposed transformer-interleaved circuit on the secondary side features the 2:1 voltage conversion ratio and minimizes the battery current ripple without adding extra switching or magnetic components. The 6:1 voltage conversion contributes to a simpler winding structure, smaller transformer size, and lower transformer loss in high voltage gain application. Furthermore, the reduced current ripple leads to lower battery heat generation and smaller filter bank capacitance, making it suitable for high-density design. The implementation of phase shift control, similar to the dual-active-bridge circuit, serves to regulate the circuit's transferred power. A 1-kW, 300-kHz, 380–420-/20–33-V GaN-based circuit prototype is developed and tested. The tested peak efficiency is 98.5% with a power density of 30.42 W/in 3 .
- 7 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 394-407
2-kV 1-MW 20000-r/min Integrated Modular Motor Drive for Electrified Aircraft Propulsion
The fight against global climate change demands the electrification of aircraft propulsion. One of the most significant and distinct challenges that future multi-megawatt electrified propulsion will face is high voltage at high altitudes, which could cause significant partial discharge and reduce the reliability of the propulsion system. Recognizing this challenge, a multi-disciplinary research team has proposed, designed, built, and preliminarily tested a 2-kV 1-MW 20,000 RPM integrated modular motor drive (IMMD) with an unprecedented weight power density of 9 kW/kg. This paper presents the architecture, major design approaches, test results of associated power electronics systems at the rated voltage and current, and preliminary test results of the full IMMD prototype. Full power and system-level altitude tests of the IMMD are already planned at the National Aeronautics and Space Administration (NASA’s) test facility.
- 7 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 394-407
2-kV 1-MW 20000-r/min Integrated Modular Motor Drive for Electrified Aircraft Propulsion
The fight against global climate change demands the electrification of aircraft propulsion. One of the most significant and distinct challenges that future multi-megawatt electrified propulsion will face is high voltage at high altitudes, which could cause significant partial discharge and reduce the reliability of the propulsion system. Recognizing this challenge, a multi-disciplinary research team has proposed, designed, built, and preliminarily tested a 2-kV 1-MW 20,000 RPM integrated modular motor drive (IMMD) with an unprecedented weight power density of 9 kW/kg. This paper presents the architecture, major design approaches, test results of associated power electronics systems at the rated voltage and current, and preliminary test results of the full IMMD prototype. Full power and system-level altitude tests of the IMMD are already planned at the National Aeronautics and Space Administration (NASA’s) test facility.
- 2 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 8 (2) , 1674-1683
Partial Discharge Inception Characteristics of Twisted Pairs Under Single Voltage Pulses Generated by Silicon-Carbide Devices
Partial discharge (PD) is a major cause of degradation of motor winding insulation. It is a challenge to the successful electrification of all types of ground, sea, and aerial vehicles. However, the mechanism of PD under pulsewidth modulated voltages is not fully understood. This article studies PD inception characteristics in twisted pairs under single voltage pulses with reduced voltage overshoot, aiming to study the PD inception characteristics and mechanism without the influences of memory effects and voltage overshoot. The tests are conducted with a lab-designed 10-kV silicon carbide (SiC) device-based voltage pulse generator. The generator can produce voltage pulses with variable rise/fall times and pulse widths to emulate the output voltages of both silicon (Si) and SiC device-based power electronics converters. The voltage overshoot in this study has been limited to less than 5%. In addition, single voltage pulses are utilized as the excitation to remove charge memory effects. PD inception voltages, PD current magnitudes, and PD time delays of twisted pair samples are measured under various test conditions. It is found that the partial discharge inception voltage (PDIV) of the test sample decreases with reduced voltage rise time and increased voltage pulsewidth. Based on the test results, the impacts of voltage rise/fall times and pulse widths on PD behavior are explained using the extended volume-time theory. The relationships between PDIV, voltage rise/fall time, and pulsewidth are presented through empirical equations. Test results and analysis provide insights on the impacts of emerging wide bandgap devices in applications on motor winding insulations.
- 2 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 8 (2) , 1674-1683
Partial Discharge Inception Characteristics of Twisted Pairs Under Single Voltage Pulses Generated by Silicon-Carbide Devices
Partial discharge (PD) is a major cause of degradation of motor winding insulation. It is a challenge to the successful electrification of all types of ground, sea, and aerial vehicles. However, the mechanism of PD under pulsewidth modulated voltages is not fully understood. This article studies PD inception characteristics in twisted pairs under single voltage pulses with reduced voltage overshoot, aiming to study the PD inception characteristics and mechanism without the influences of memory effects and voltage overshoot. The tests are conducted with a lab-designed 10-kV silicon carbide (SiC) device-based voltage pulse generator. The generator can produce voltage pulses with variable rise/fall times and pulse widths to emulate the output voltages of both silicon (Si) and SiC device-based power electronics converters. The voltage overshoot in this study has been limited to less than 5%. In addition, single voltage pulses are utilized as the excitation to remove charge memory effects. PD inception voltages, PD current magnitudes, and PD time delays of twisted pair samples are measured under various test conditions. It is found that the partial discharge inception voltage (PDIV) of the test sample decreases with reduced voltage rise time and increased voltage pulsewidth. Based on the test results, the impacts of voltage rise/fall times and pulse widths on PD behavior are explained using the extended volume-time theory. The relationships between PDIV, voltage rise/fall time, and pulsewidth are presented through empirical equations. Test results and analysis provide insights on the impacts of emerging wide bandgap devices in applications on motor winding insulations.
- Open Access
- 1 December 2020
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 5 (6) , 669-678
Influence of frequency on the surface discharge characteristics of PEEK under positive repetitive square voltage
In this study, the surface discharge current pulses of polyetheretherketone (PEEK) material under positive repetitive square voltage in a nitrogen atmosphere are measured. The influences of different voltage amplitudes and frequencies on the detail parameters of forward discharge and backward discharge current pulses are statistically analysed. The results show that as the square voltage amplitude increases, the current pulse amplitude, fall time and pulse width of both forward and backward discharge current increase, and the rise time does not change significantly. As the voltage frequency increases, current pulse amplitude, fall time and pulse width of both forward and backward discharge current decrease, and the rise time does not change significantly. Due to the independence of the discharge at different repetitive cycles, the specific discharge process in one cycle is analysed in detail to explain the influence mechanism of the voltage amplitude and frequency on the discharge current. By mean of the Richardson–Schottky and the Cavallini relaxation model, the relationship between discharge voltage ratio and surface charge, and the decay process of surface discharge are analysed. Furthermore, the influences of amplitude and frequency of the positive repetitive square voltage on the PEEK surface current pulses are explained qualitatively.
- 1 December 2020
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 5 (6) , 669-678
Open AccessInfluence of frequency on the surface discharge characteristics of PEEK under positive repetitive square voltage
In this study, the surface discharge current pulses of polyetheretherketone (PEEK) material under positive repetitive square voltage in a nitrogen atmosphere are measured. The influences of different voltage amplitudes and frequencies on the detail parameters of forward discharge and backward discharge current pulses are statistically analysed. The results show that as the square voltage amplitude increases, the current pulse amplitude, fall time and pulse width of both forward and backward discharge current increase, and the rise time does not change significantly. As the voltage frequency increases, current pulse amplitude, fall time and pulse width of both forward and backward discharge current decrease, and the rise time does not change significantly. Due to the independence of the discharge at different repetitive cycles, the specific discharge process in one cycle is analysed in detail to explain the influence mechanism of the voltage amplitude and frequency on the discharge current. By mean of the Richardson–Schottky and the Cavallini relaxation model, the relationship between discharge voltage ratio and surface charge, and the decay process of surface discharge are analysed. Furthermore, the influences of amplitude and frequency of the positive repetitive square voltage on the PEEK surface current pulses are explained qualitatively.
- Open Access
- 1 January 2019
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 12 (1) , 138-146
Partial discharge measurement and analysis in PPIs
Electrical insulation capability is one of the most critical challenges for press‐pack insulated gate bipolar transistors (IGBTs), but the knowledge of its insulation failure mechanism is much less mature. To understand the insulation failure mechanism, partial discharge (PD) measurement and analysis in press‐pack IGBT (PPI) submodule were performed in this study. A dedicated PD measurement system for PPIs was designed and fabricated, and fast oscilloscope, PD detector and ultraviolet (UV) image camera were employed to observe the PD. PD‐induced insulation failure phenomenon in the submodule was observed under direct current voltage, and UV images indicated that the discharge occurred at the periphery of the die. Phase‐resolved PD (PRPD) analysis method for PPIs was developed and three elementary structures were used to simulate the PD in the electric field reinforcement areas identified by electric field analysis. According to PRPD patterns, the observed PD in the submodule was considered to be mainly caused by a mismatch between the electric field and critical electric field on the surface of passivation layers of the die. The inference was verified at different gas pressures because a decrease of PD inception voltage in the submodule and the bare die was observed at lower gas pressure.
- 1 January 2019
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 12 (1) , 138-146
Open AccessPartial discharge measurement and analysis in PPIs
Electrical insulation capability is one of the most critical challenges for press‐pack insulated gate bipolar transistors (IGBTs), but the knowledge of its insulation failure mechanism is much less mature. To understand the insulation failure mechanism, partial discharge (PD) measurement and analysis in press‐pack IGBT (PPI) submodule were performed in this study. A dedicated PD measurement system for PPIs was designed and fabricated, and fast oscilloscope, PD detector and ultraviolet (UV) image camera were employed to observe the PD. PD‐induced insulation failure phenomenon in the submodule was observed under direct current voltage, and UV images indicated that the discharge occurred at the periphery of the die. Phase‐resolved PD (PRPD) analysis method for PPIs was developed and three elementary structures were used to simulate the PD in the electric field reinforcement areas identified by electric field analysis. According to PRPD patterns, the observed PD in the submodule was considered to be mainly caused by a mismatch between the electric field and critical electric field on the surface of passivation layers of the die. The inference was verified at different gas pressures because a decrease of PD inception voltage in the submodule and the bare die was observed at lower gas pressure.
- 1 September 2018
- Published by AIP Publishing in Physics of Plasmas
- Vol. 25 (9) , 093518
The role of time-lag in the surface discharge inception under positive repetitive pulse voltage
Polyetheretherketone is used in the packaging of high voltage power electronics as a frame material, and the surface discharge behaviors of polyetheretherketone are the main concerns for the packaging design. Pulse width modulation voltage, which shows a variable duty cycle, is applied to polyetheretherketone at working conditions. The surface discharge behaviors of polyetheretherketone under a positive repetitive pulse voltage of 50 Hz with different duty cycles were investigated in this paper. It is generally considered that the surface discharge inception is mainly related to electric field distribution; however, the pulse width of voltage could significantly affect the surface discharge inception characteristics. In this study, the surface discharge inception voltage, time-integrated streamer images, and cumulative surface discharge patterns under a positive repetitive pulse voltage of 50 Hz were obtained. It was found that the surface discharge inception voltage decreased with the increase in the duty cycle. This relationship was explained by the role of time-lag. Time-lag distribution analysis was performed, and the time-lag distribution was mainly determined by stochastic time-lag. The mean stochastic time-lag was obtained by the Laue plot, and the relationship between the mean stochastic time-lag and applied voltage could be well fitted by the inverse power law. Furthermore, the relationship between the surface discharge inception voltage and duty cycle could be exactly fitted by the inverse power law, which was derived from the relationship between the stochastic mean time-lag and applied voltage. The closely related relationships demonstrate that time-lag plays a critical role in the surface discharge inception at different duty cycles.
- 1 September 2018
- Published by AIP Publishing in Physics of Plasmas
- Vol. 25 (9) , 093518
The role of time-lag in the surface discharge inception under positive repetitive pulse voltage
Polyetheretherketone is used in the packaging of high voltage power electronics as a frame material, and the surface discharge behaviors of polyetheretherketone are the main concerns for the packaging design. Pulse width modulation voltage, which shows a variable duty cycle, is applied to polyetheretherketone at working conditions. The surface discharge behaviors of polyetheretherketone under a positive repetitive pulse voltage of 50 Hz with different duty cycles were investigated in this paper. It is generally considered that the surface discharge inception is mainly related to electric field distribution; however, the pulse width of voltage could significantly affect the surface discharge inception characteristics. In this study, the surface discharge inception voltage, time-integrated streamer images, and cumulative surface discharge patterns under a positive repetitive pulse voltage of 50 Hz were obtained. It was found that the surface discharge inception voltage decreased with the increase in the duty cycle. This relationship was explained by the role of time-lag. Time-lag distribution analysis was performed, and the time-lag distribution was mainly determined by stochastic time-lag. The mean stochastic time-lag was obtained by the Laue plot, and the relationship between the mean stochastic time-lag and applied voltage could be well fitted by the inverse power law. Furthermore, the relationship between the surface discharge inception voltage and duty cycle could be exactly fitted by the inverse power law, which was derived from the relationship between the stochastic mean time-lag and applied voltage. The closely related relationships demonstrate that time-lag plays a critical role in the surface discharge inception at different duty cycles.
- Open Access
- 1 July 2018
- Published by AIP Publishing in AIP Advances
- Vol. 8 (7) , 075322
Surface discharge characteristics and initiation mechanism of PEEK in nitrogen under semi-square voltage
The surface discharge behaviors of polyetheretherketone (PEEK) in nitrogen under both positive and negative semi-square voltage were investigated using the current pulse detection method by non-inductive resistor and optical signal detection method by photomultiplier and digital camera. A 50Hz positive or negative semi-square voltage was applied to a rod-plane electrode system, and two types of surface discharge in a voltage cycle were found: one forward discharge and one back discharge. The characteristics and initiation mechanism of the two types of surface discharge were explored. The experimental results showed that surface discharges between cycles were independent. Based on the independence, the time-lag characteristics of surface discharge were obtained. An improvement on Laue-Zuber time-lag theory was made to fit the time-lag characteristics of forward discharge and back discharge. The mean time-lag decreased with the increase of voltage for both forward discharge and back discharge, and the relation between mean time-lag and applied voltage could be modeled by inverse power law. Comparative analysis on the characteristics of back discharge and forward discharge under opposite voltage was performed, and the characteristics of back discharge and forward discharge under opposite voltage were homogenous. In addition, the initiation mechanism of the two types of discharge was discussed. The initiation of forward discharge is believed to be mainly determined by the time-lag and the electric field caused by the applied voltage, while the initiation of back discharge is believed to be mainly determined by the time-lag and the electric field induced by the residual surface charge left by the forward discharge in the same cycle. Verification tests under positive semi-square voltage with different fall time were conducted to validate the initiation mechanism.
- 1 July 2018
- Published by AIP Publishing in AIP Advances
- Vol. 8 (7) , 075322
Open AccessSurface discharge characteristics and initiation mechanism of PEEK in nitrogen under semi-square voltage
The surface discharge behaviors of polyetheretherketone (PEEK) in nitrogen under both positive and negative semi-square voltage were investigated using the current pulse detection method by non-inductive resistor and optical signal detection method by photomultiplier and digital camera. A 50Hz positive or negative semi-square voltage was applied to a rod-plane electrode system, and two types of surface discharge in a voltage cycle were found: one forward discharge and one back discharge. The characteristics and initiation mechanism of the two types of surface discharge were explored. The experimental results showed that surface discharges between cycles were independent. Based on the independence, the time-lag characteristics of surface discharge were obtained. An improvement on Laue-Zuber time-lag theory was made to fit the time-lag characteristics of forward discharge and back discharge. The mean time-lag decreased with the increase of voltage for both forward discharge and back discharge, and the relation between mean time-lag and applied voltage could be modeled by inverse power law. Comparative analysis on the characteristics of back discharge and forward discharge under opposite voltage was performed, and the characteristics of back discharge and forward discharge under opposite voltage were homogenous. In addition, the initiation mechanism of the two types of discharge was discussed. The initiation of forward discharge is believed to be mainly determined by the time-lag and the electric field caused by the applied voltage, while the initiation of back discharge is believed to be mainly determined by the time-lag and the electric field induced by the residual surface charge left by the forward discharge in the same cycle. Verification tests under positive semi-square voltage with different fall time were conducted to validate the initiation mechanism.