Subha Hency Jose Paul
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Subha Hency Jose Paul has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Anantha Christu Raj Palayyan
Division of Robotics Engineering, Karunya Institute of Technology and Sciences, Coimbatore, India
2 shared publications - Geetika Yadav
Indian Council for Medical Research, New Delhi, India
2 shared publications - Jayakumar Jayaraj
Division of Electrical and Electronics Engineering, Karunya Institute of Technology and Sciences, Coimbatore, India
2 shared publications P. Rajalakshmy
Karunya Institute of Technology and Sciences
2 shared publications- Vijai Sivalingam
Division of Biomedical Engineering, Karunya Institute of Technology and Sciences, Coimbatore, India
2 shared publications - Vijitha Ananthi Jayasingh
Department of Computer Science and Engineering, Vignan’s Foundation for Science, Technology and Research, Vadlamudi, India
2 shared publications
Latest Publications
- Open Access
- 8 October 2026
- Published by Springer Nature in Discover Applied Sciences
Smart oxygen delivery using IoT-based physiological monitoring and adaptive oxygen flow control
This study presents the design and development of a portable oxygen concentrator prototype with IoT-enabled monitoring and automated oxygen-flow regulation based on measured physiological parameters. An ESP32 microcontroller processes data and handles wireless communication, while a MAX30102 sensor measures peripheral oxygen saturation (SpO 2 ) and heart rate for system monitoring and control. The developed prototype provides oxygen flow rates ranging from 1 to 5 LPM, with oxygen purity measured between 90.68 ± 0.084% and 93.34 ± 0.114% across the tested flow conditions. The corresponding outlet pressure ranged from 1.150 ± 0.007 to 1.200 ± 0.007 bar, while stabilization time increased from 32.0 ± 0.707 to 46.0 ± 0.707 s. Power consumption increased from 142 to 150 W as the flow rate increased from 1 to 5 LPM. Each operating condition was evaluated using five experimental repetitions. In automatic mode, the closed-loop controller adjusts the oxygen-flow setting according to variations in the measured SpO 2 level. The system achieved a local control latency of 42.0 ± 3.0 ms, a ThingSpeak communication latency of 195.0 ± 8.0 ms, and a total end-to-end latency of 237.0 ± 7.0 ms. The acquired measurements were displayed locally through an OLED interface and transmitted to the ThingSpeak cloud platform for remote monitoring. The developed system is a bench-tested research prototype, and the reported results are limited to laboratory-level evaluation. The findings demonstrate the feasibility of integrating physiological sensing, automated flow regulation, and IoT-based monitoring within a portable oxygen-concentrator prototype; however, clinical validation and long-term reliability assessment are required before any medical or patient-specific application can be established.
- 8 October 2026
- Published by Springer Nature in Discover Applied Sciences
Open AccessSmart oxygen delivery using IoT-based physiological monitoring and adaptive oxygen flow control
This study presents the design and development of a portable oxygen concentrator prototype with IoT-enabled monitoring and automated oxygen-flow regulation based on measured physiological parameters. An ESP32 microcontroller processes data and handles wireless communication, while a MAX30102 sensor measures peripheral oxygen saturation (SpO 2 ) and heart rate for system monitoring and control. The developed prototype provides oxygen flow rates ranging from 1 to 5 LPM, with oxygen purity measured between 90.68 ± 0.084% and 93.34 ± 0.114% across the tested flow conditions. The corresponding outlet pressure ranged from 1.150 ± 0.007 to 1.200 ± 0.007 bar, while stabilization time increased from 32.0 ± 0.707 to 46.0 ± 0.707 s. Power consumption increased from 142 to 150 W as the flow rate increased from 1 to 5 LPM. Each operating condition was evaluated using five experimental repetitions. In automatic mode, the closed-loop controller adjusts the oxygen-flow setting according to variations in the measured SpO 2 level. The system achieved a local control latency of 42.0 ± 3.0 ms, a ThingSpeak communication latency of 195.0 ± 8.0 ms, and a total end-to-end latency of 237.0 ± 7.0 ms. The acquired measurements were displayed locally through an OLED interface and transmitted to the ThingSpeak cloud platform for remote monitoring. The developed system is a bench-tested research prototype, and the reported results are limited to laboratory-level evaluation. The findings demonstrate the feasibility of integrating physiological sensing, automated flow regulation, and IoT-based monitoring within a portable oxygen-concentrator prototype; however, clinical validation and long-term reliability assessment are required before any medical or patient-specific application can be established.
- Open Access
- 24 October 2025
- Published by Springer Nature in Discover Applied Sciences
- Vol. 7 (11) , 1-37
Intelligent oxygen delivery: a portable concentrator combining closed-loop automation, PSA, and Q-learning for optimized performance
- 24 October 2025
- Published by Springer Nature in Discover Applied Sciences
- Vol. 7 (11) , 1-37
Open AccessIntelligent oxygen delivery: a portable concentrator combining closed-loop automation, PSA, and Q-learning for optimized performance
- 1 January 2025
- Published by American Scientific Publishing Group (ASPG) LLC in Fusion: Practice and Applications
- Vol. 17 (1) , 95-5-106
Advanced Stress Detection and Analysis Framework using Integration of FFT, SVM, and CNN
American scientific publishing group
- 1 January 2025
- Published by American Scientific Publishing Group (ASPG) LLC in Fusion: Practice and Applications
- Vol. 17 (1) , 95-5-106
Advanced Stress Detection and Analysis Framework using Integration of FFT, SVM, and CNN
American scientific publishing group
- 10 October 2024
- Published by Springer Nature in National Academy Science Letters
- Vol. 48 (3) , 309-312
Enhanced Secure Trusted Routing Path Selection for Internet of Medical Things
- 10 October 2024
- Published by Springer Nature in National Academy Science Letters
- Vol. 48 (3) , 309-312
Enhanced Secure Trusted Routing Path Selection for Internet of Medical Things
- 2 August 2022
- Published by Springer Nature
- p. 213-225
Smart Fetal Health Monitor
- 2 December 2021
- Published by Springer Nature
- p. 243-257
A Novel Sensing Technique for Continuous Monitoring of Volume in an Automobile Fuel Tank
- 2 December 2021
- Published by Springer Nature
- p. 243-257
A Novel Sensing Technique for Continuous Monitoring of Volume in an Automobile Fuel Tank
- 18 October 2021
- Published by Springer Nature in International Journal of Wireless Information Networks
- Vol. 28 (4) , 451-466
A Perspective Review of Security Challenges in Body Area Networks for Healthcare Applications
Body area network (BAN) connects sensors and actuators to the human body in order to collect patient’s information and transmitting it to doctors in a confined space with limited users. wireless body area network (WBAN) is derived from wireless sensor networks (WSN) and enables to transfer of the patient's information with a wide range of communication due to the limitations of the wired body area network. It plays a vital role in healthcare monitoring, healthcare systems, medical field, sports field, and multimedia communication. Sensors and actuators lead to high energy consumption due to their tiny size. WBAN facilitates in securely storing patient information and transmitting it to the doctor without data loss at a specific time. This review examines and summarizes methodological approaches in WBAN relating to security, safety, reliability, and the fastest transmission. Flying body area networks (FBAN) utilizing unmanned aerial vehicles for data transmission are recommended to promote rapid and secure communication in WBAN. FBAN improve the security, scalability, and speed in order to transmit patient’s information to the doctor due to high mobility.
- 18 October 2021
- Published by Springer Nature in International Journal of Wireless Information Networks
- Vol. 28 (4) , 451-466
A Perspective Review of Security Challenges in Body Area Networks for Healthcare Applications
Body area network (BAN) connects sensors and actuators to the human body in order to collect patient’s information and transmitting it to doctors in a confined space with limited users. wireless body area network (WBAN) is derived from wireless sensor networks (WSN) and enables to transfer of the patient's information with a wide range of communication due to the limitations of the wired body area network. It plays a vital role in healthcare monitoring, healthcare systems, medical field, sports field, and multimedia communication. Sensors and actuators lead to high energy consumption due to their tiny size. WBAN facilitates in securely storing patient information and transmitting it to the doctor without data loss at a specific time. This review examines and summarizes methodological approaches in WBAN relating to security, safety, reliability, and the fastest transmission. Flying body area networks (FBAN) utilizing unmanned aerial vehicles for data transmission are recommended to promote rapid and secure communication in WBAN. FBAN improve the security, scalability, and speed in order to transmit patient’s information to the doctor due to high mobility.
- 16 December 2020
- Published by Elsevier in Materials Today: Proceedings
- Vol. 45, 2524-2527
Role of sensor technology in liquid level measurement of molten metal
- 16 December 2020
- Published by Elsevier in Materials Today: Proceedings
- Vol. 45, 2524-2527
Role of sensor technology in liquid level measurement of molten metal
- Open Access
- 17 October 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 247 (1) , 012006
An Improved Method to Control the Critical Parameters of a Multivariable Control System
The role of control systems is to cope with the process deficiencies and the undesirable effect of the external disturbances. Most of the multivariable processes are highly iterative and complex in nature. Aircraft systems, Modern Power Plants, Refineries, Robotic systems are few such complex systems that involve numerous critical parameters that need to be monitored and controlled. Control of these important parameters is not only tedious and cumbersome but also is crucial from environmental, safety and quality perspective. In this paper, one such multivariable system, namely, a utility boiler has been considered. A modern power plant is a complex arrangement of pipework and machineries with numerous interacting control loops and support systems. In this paper, the calculation of controller parameters based on classical tuning concepts has been presented. The controller parameters thus obtained and employed has controlled the critical parameters of a boiler during fuel switching disturbances. The proposed method can be applied to control the critical parameters like elevator, aileron, rudder, elevator trim rudder and aileron trim, flap control systems of aircraft systems.
- 17 October 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 247 (1) , 012006
Open AccessAn Improved Method to Control the Critical Parameters of a Multivariable Control System
The role of control systems is to cope with the process deficiencies and the undesirable effect of the external disturbances. Most of the multivariable processes are highly iterative and complex in nature. Aircraft systems, Modern Power Plants, Refineries, Robotic systems are few such complex systems that involve numerous critical parameters that need to be monitored and controlled. Control of these important parameters is not only tedious and cumbersome but also is crucial from environmental, safety and quality perspective. In this paper, one such multivariable system, namely, a utility boiler has been considered. A modern power plant is a complex arrangement of pipework and machineries with numerous interacting control loops and support systems. In this paper, the calculation of controller parameters based on classical tuning concepts has been presented. The controller parameters thus obtained and employed has controlled the critical parameters of a boiler during fuel switching disturbances. The proposed method can be applied to control the critical parameters like elevator, aileron, rudder, elevator trim rudder and aileron trim, flap control systems of aircraft systems.