Hironori Kojima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hironori Kojima has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Akihiro Takemura
Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan
4 shared publications Kimiya Noto
Department of Radiology, Kanazawa University Hospital, Kanazawa University, Ishikawa, Japan
4 shared publicationsNaoki Isomura
Department of Radiology, Kanazawa University Hospital, Kanazawa University, Ishikawa, Japan
3 shared publicationsShinichi Ueda
Department of Radiology Kanazawa University Hospital Kanazawa Ishikawa Japan
3 shared publicationsKosuke Tsukamoto
Department of Radiology, Kanazawa University Hospital, Kanazawa University, Ishikawa, Japan
2 shared publicationsShogo Kurokawa
Radiation Safety and Quality Assurance division, National Cancer Center Hospital East, Kashiwa, Chiba, Japan
2 shared publications
Latest Publications
- Open Access
- 29 October 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11)
A multicenter end‐to‐end postal audit of skin markerless surface‐guided radiation therapy
Background: Surface‐guided radiation therapy (SGRT) enables skin markerless positioning, but its accuracy may depend on the reference surface, hardware configuration, commissioning, and institutional workflow. Two reference surfaces are commonly used: a DICOM reference generated from planning CT images and an SGRT reference acquired in the treatment room. Multicenter end‐to‐end data across commercial systems remain limited. Purpose: To evaluate static irradiation accuracy and setup time with two reference surfaces in a nationwide multicenter skin markerless SGRT postal audit. Methods: A prospective end‐to‐end postal audit was conducted from October 2023 to July 2025 at 40 Japanese institutions using five commercial SGRT systems (AlignRT, Catalyst, ExacTrac Dynamic, IDENTIFY, and VOXELAN), eight per system. Each institution received a common phantom package: a breast‐shaped surface phantom, two cubic phantoms containing gold markers, and radiochromic films. Markerless setup and irradiation were performed with both the DICOM and SGRT references; ExacTrac Dynamic institutions performed the DICOM reference setup only. Static irradiation accuracy was the difference between the film‐derived radiation center and the intended center in the DICOM RT Plan; the primary metric was the three‐dimensional translational vector error (3D vector error). Paired comparisons used the Wilcoxon signed‐rank test, and multivariable linear regression evaluated factors associated with both endpoints. Results: Critical setup errors exceeding 5 mm occurred at four institutions initially (institution‐level error rate, 10.0%; three with the DICOM and one with the SGRT reference); one DICOM reference setup was not remeasured and remained out of tolerance, and was excluded as an outlier, leaving 39 DICOM and 31 SGRT reference setups for analysis. Excluding ExacTrac Dynamic, the DICOM reference showed a significantly larger 3D vector error than the SGRT reference (1.54 ± 0.91 vs. 1.20 ± 0.61 mm, p = 0.043). Setup time did not differ between references (86.19 ± 43.57 vs. 81.61 ± 37.09 s, p = 0.804). Axis‐specifically, the difference between references was confined to the anterior–posterior direction (mean absolute difference 0.36 mm, p = 0.002), whereas a caudal superior–inferior offset was present with both (−0.50 ± 1.29 and −0.37 ± 0.87 mm; both p < 0.01) and did not differ between them ( p = 0.854). The 1‐camera condition was independently associated with a larger 3D vector error than the 3‐camera condition (β = 0.90 mm; 95% CI, 0.17–1.63 mm; p = 0.017); no factor was associated with setup time, which showed no correlation with 3D vector error. Conclusions: Skin markerless SGRT achieved millimeter‐level static irradiation accuracy but carried a non‐negligible risk of critical setup errors. The difference between the two reference workflows was confined to the anterior–posterior direction, whereas a superior–inferior offset common to both indicates a residual uncertainty in the audit chain itself. Reference surface selection and camera configuration influenced accuracy, whereas setup time was not a reliable surrogate. These findings highlight the importance of commissioning, standardized reference surface acquisition, routine QA, and independent third‐party audits.
- 29 October 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11)
Open AccessA multicenter end‐to‐end postal audit of skin markerless surface‐guided radiation therapy
Background: Surface‐guided radiation therapy (SGRT) enables skin markerless positioning, but its accuracy may depend on the reference surface, hardware configuration, commissioning, and institutional workflow. Two reference surfaces are commonly used: a DICOM reference generated from planning CT images and an SGRT reference acquired in the treatment room. Multicenter end‐to‐end data across commercial systems remain limited. Purpose: To evaluate static irradiation accuracy and setup time with two reference surfaces in a nationwide multicenter skin markerless SGRT postal audit. Methods: A prospective end‐to‐end postal audit was conducted from October 2023 to July 2025 at 40 Japanese institutions using five commercial SGRT systems (AlignRT, Catalyst, ExacTrac Dynamic, IDENTIFY, and VOXELAN), eight per system. Each institution received a common phantom package: a breast‐shaped surface phantom, two cubic phantoms containing gold markers, and radiochromic films. Markerless setup and irradiation were performed with both the DICOM and SGRT references; ExacTrac Dynamic institutions performed the DICOM reference setup only. Static irradiation accuracy was the difference between the film‐derived radiation center and the intended center in the DICOM RT Plan; the primary metric was the three‐dimensional translational vector error (3D vector error). Paired comparisons used the Wilcoxon signed‐rank test, and multivariable linear regression evaluated factors associated with both endpoints. Results: Critical setup errors exceeding 5 mm occurred at four institutions initially (institution‐level error rate, 10.0%; three with the DICOM and one with the SGRT reference); one DICOM reference setup was not remeasured and remained out of tolerance, and was excluded as an outlier, leaving 39 DICOM and 31 SGRT reference setups for analysis. Excluding ExacTrac Dynamic, the DICOM reference showed a significantly larger 3D vector error than the SGRT reference (1.54 ± 0.91 vs. 1.20 ± 0.61 mm, p = 0.043). Setup time did not differ between references (86.19 ± 43.57 vs. 81.61 ± 37.09 s, p = 0.804). Axis‐specifically, the difference between references was confined to the anterior–posterior direction (mean absolute difference 0.36 mm, p = 0.002), whereas a caudal superior–inferior offset was present with both (−0.50 ± 1.29 and −0.37 ± 0.87 mm; both p < 0.01) and did not differ between them ( p = 0.854). The 1‐camera condition was independently associated with a larger 3D vector error than the 3‐camera condition (β = 0.90 mm; 95% CI, 0.17–1.63 mm; p = 0.017); no factor was associated with setup time, which showed no correlation with 3D vector error. Conclusions: Skin markerless SGRT achieved millimeter‐level static irradiation accuracy but carried a non‐negligible risk of critical setup errors. The difference between the two reference workflows was confined to the anterior–posterior direction, whereas a superior–inferior offset common to both indicates a residual uncertainty in the audit chain itself. Reference surface selection and camera configuration influenced accuracy, whereas setup time was not a reliable surrogate. These findings highlight the importance of commissioning, standardized reference surface acquisition, routine QA, and independent third‐party audits.
- 25 July 2022
- Published by Elsevier in Brachytherapy
- Vol. 21 (6) , 956-967
Multi-Institutional Study of End-to-End Dose Delivery Quality Assurance Testing for Image-Guided Brachytherapy Using a Gel Dosimeter
- 25 July 2022
- Published by Elsevier in Brachytherapy
- Vol. 21 (6) , 956-967
Multi-Institutional Study of End-to-End Dose Delivery Quality Assurance Testing for Image-Guided Brachytherapy Using a Gel Dosimeter
- Open Access
- 27 December 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (2) , 58-68
Evaluation of technical performance of optical surface imaging system using conventional and novel stereotactic radiosurgery algorithms
The Catalyst HD (C‐RAD Positioning AB, Uppsala, Sweden) optical surface imaging (OSI) system is able to manage interfractional patient positioning, intrafractional motion monitoring, and non‐contact respiratory gating without x‐ray exposure for radiation therapy. In recent years, a novel high‐precision surface registration algorithm for stereotactic radiosurgery (SRS algorithm) has been released. This study aimed to evaluate the technical performance of the OSI system using rigid phantoms, by comparing the conventional and SRS algorithms. To determine the system’s technical performance, isocenter displacements were calculated by surface image registration via the OSI system using head, thorax, and pelvis rigid phantoms. The reproducibility of positioning was evaluated by the mean value calculated by repeating the registration 10 times, without moving each phantom. The accuracy of positioning was evaluated by the mean value of the residual error, where the 10 offset values given to each phantom were subtracted from the isocenter displacement values. The stability of motion monitoring was evaluated by measuring isocenter drift during 20 min and averaging it over 10 measurements. For the head phantom, all tests were compared with the mask types and algorithms. As a result, for all sites and both algorithms, the reproducibility, accuracy, and stability for translation and rotation were P < 0.01). There was no difference in the stability between the algorithms (P = 0.0280). The SRS algorithm was found to be suitable for the treatment of rigid body sites with less deformation and small area, such as the head and face.
- 27 December 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (2) , 58-68
Open AccessEvaluation of technical performance of optical surface imaging system using conventional and novel stereotactic radiosurgery algorithms
The Catalyst HD (C‐RAD Positioning AB, Uppsala, Sweden) optical surface imaging (OSI) system is able to manage interfractional patient positioning, intrafractional motion monitoring, and non‐contact respiratory gating without x‐ray exposure for radiation therapy. In recent years, a novel high‐precision surface registration algorithm for stereotactic radiosurgery (SRS algorithm) has been released. This study aimed to evaluate the technical performance of the OSI system using rigid phantoms, by comparing the conventional and SRS algorithms. To determine the system’s technical performance, isocenter displacements were calculated by surface image registration via the OSI system using head, thorax, and pelvis rigid phantoms. The reproducibility of positioning was evaluated by the mean value calculated by repeating the registration 10 times, without moving each phantom. The accuracy of positioning was evaluated by the mean value of the residual error, where the 10 offset values given to each phantom were subtracted from the isocenter displacement values. The stability of motion monitoring was evaluated by measuring isocenter drift during 20 min and averaging it over 10 measurements. For the head phantom, all tests were compared with the mask types and algorithms. As a result, for all sites and both algorithms, the reproducibility, accuracy, and stability for translation and rotation were P < 0.01). There was no difference in the stability between the algorithms (P = 0.0280). The SRS algorithm was found to be suitable for the treatment of rigid body sites with less deformation and small area, such as the head and face.
- 14 May 2020
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 20 (3) , 316-320
The effect of photon energy on dose distribution in volumetric-modulated arc therapy planning for head and neck cancer
Aim: To investigate the effect of different energies on dose distribution in volumetric-modulated arc therapy (VMAT) plans for head and neck cancer.Materials and methods: Data from nine patients undergoing VMAT plans using 6 MV, 10 MV and dual-energy X-ray beams with the Pinnacle 3 V 9.10 treatment planning system (Philips Medical System, Fitchburg, WI, USA) were analysed for quality using the conformity index (CI) and homogeneity index (HI) for planning target volume (PTV), and for mean and maximum dose to the organs at risk (OARs): parotid glands, brainstem, spinal cord and optic nerves.Results: There were no clear differences in the HIs of the PTV dose among the different plans. The CIs for 10 MV and dual-energy VMAT plans were superior to that of the 6 MV VMAT plan (0·8 ± 0·3, 0·8 ± 0·3, and 0·7 ± 0·2, respectively; p = 0·001). There were no significant differences in mean/maximum dose to the OARs among the three VMAT plans.Findings: Compared with the 6 MV VMAT plan, the dual-energy VMAT plan slightly increased the coverage of the PTV with the prescribed dose but did not decrease dose to the OARs.
- 14 May 2020
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 20 (3) , 316-320
The effect of photon energy on dose distribution in volumetric-modulated arc therapy planning for head and neck cancer
Aim: To investigate the effect of different energies on dose distribution in volumetric-modulated arc therapy (VMAT) plans for head and neck cancer.Materials and methods: Data from nine patients undergoing VMAT plans using 6 MV, 10 MV and dual-energy X-ray beams with the Pinnacle 3 V 9.10 treatment planning system (Philips Medical System, Fitchburg, WI, USA) were analysed for quality using the conformity index (CI) and homogeneity index (HI) for planning target volume (PTV), and for mean and maximum dose to the organs at risk (OARs): parotid glands, brainstem, spinal cord and optic nerves.Results: There were no clear differences in the HIs of the PTV dose among the different plans. The CIs for 10 MV and dual-energy VMAT plans were superior to that of the 6 MV VMAT plan (0·8 ± 0·3, 0·8 ± 0·3, and 0·7 ± 0·2, respectively; p = 0·001). There were no significant differences in mean/maximum dose to the OARs among the three VMAT plans.Findings: Compared with the 6 MV VMAT plan, the dual-energy VMAT plan slightly increased the coverage of the PTV with the prescribed dose but did not decrease dose to the OARs.
- Open Access
- 1 April 2018
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 6, 77-82
An uncertainty metric to evaluate deformation vector fields for dose accumulation in radiotherapy
- 1 April 2018
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 6, 77-82
Open AccessAn uncertainty metric to evaluate deformation vector fields for dose accumulation in radiotherapy