A multicenter end‐to‐end postal audit of skin markerless surface‐guided radiation therapy
Open Access
- 29 October 2026
- journal article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11)
Abstract
Background: Surface‐guided radiation therapy (SGRT) enables skin markerless positioning, but its accuracy may depend on the reference surface, hardware configuration, commissioning, and institutional workflow. Two reference surfaces are commonly used: a DICOM reference generated from planning CT images and an SGRT reference acquired in the treatment room. Multicenter end‐to‐end data across commercial systems remain limited. Purpose: To evaluate static irradiation accuracy and setup time with two reference surfaces in a nationwide multicenter skin markerless SGRT postal audit. Methods: A prospective end‐to‐end postal audit was conducted from October 2023 to July 2025 at 40 Japanese institutions using five commercial SGRT systems (AlignRT, Catalyst, ExacTrac Dynamic, IDENTIFY, and VOXELAN), eight per system. Each institution received a common phantom package: a breast‐shaped surface phantom, two cubic phantoms containing gold markers, and radiochromic films. Markerless setup and irradiation were performed with both the DICOM and SGRT references; ExacTrac Dynamic institutions performed the DICOM reference setup only. Static irradiation accuracy was the difference between the film‐derived radiation center and the intended center in the DICOM RT Plan; the primary metric was the three‐dimensional translational vector error (3D vector error). Paired comparisons used the Wilcoxon signed‐rank test, and multivariable linear regression evaluated factors associated with both endpoints. Results: Critical setup errors exceeding 5 mm occurred at four institutions initially (institution‐level error rate, 10.0%; three with the DICOM and one with the SGRT reference); one DICOM reference setup was not remeasured and remained out of tolerance, and was excluded as an outlier, leaving 39 DICOM and 31 SGRT reference setups for analysis. Excluding ExacTrac Dynamic, the DICOM reference showed a significantly larger 3D vector error than the SGRT reference (1.54 ± 0.91 vs. 1.20 ± 0.61 mm, p = 0.043). Setup time did not differ between references (86.19 ± 43.57 vs. 81.61 ± 37.09 s, p = 0.804). Axis‐specifically, the difference between references was confined to the anterior–posterior direction (mean absolute difference 0.36 mm, p = 0.002), whereas a caudal superior–inferior offset was present with both (−0.50 ± 1.29 and −0.37 ± 0.87 mm; both p < 0.01) and did not differ between them ( p = 0.854). The 1‐camera condition was independently associated with a larger 3D vector error than the 3‐camera condition (β = 0.90 mm; 95% CI, 0.17–1.63 mm; p = 0.017); no factor was associated with setup time, which showed no correlation with 3D vector error. Conclusions: Skin markerless SGRT achieved millimeter‐level static irradiation accuracy but carried a non‐negligible risk of critical setup errors. The difference between the two reference workflows was confined to the anterior–posterior direction, whereas a superior–inferior offset common to both indicates a residual uncertainty in the audit chain itself. Reference surface selection and camera configuration influenced accuracy, whereas setup time was not a reliable surrogate. These findings highlight the importance of commissioning, standardized reference surface acquisition, routine QA, and independent third‐party audits.Keywords
This publication has 22 references indexed in Scilit:
- Enhancing patient positioning precision: a comparative analysis of surface-guided radiation therapy systemsRadiological Physics and Technology, 2025
- Clinical technique: evaluation of detection accuracy in surface-guided radiation therapy using CT references from different treatment planning systemsRadiological Physics and Technology, 2025
- Development of dedicated phantom for end‐to‐end testing of multiple image‐guidance configurations incorporating light‐section‐based surface guidance systemJournal of Applied Clinical Medical Physics, 2024
- Development of a phantom for assessing the precision of setup in skin mark‐less surface‐guided radiotherapyJournal of Applied Clinical Medical Physics, 2024
- Characterization of the IDENTIFYTM surface scanning system for radiation therapy setup on a closed‐bore linacJournal of Applied Clinical Medical Physics, 2024
- Commissioning and clinical evaluation of the IDENTIFYTM surface imaging system for frameless stereotactic radiosurgeryJournal of Applied Clinical Medical Physics, 2023
- Surface guided radiotherapy (SGRT) improves breast cancer patient setup accuracyJournal of Applied Clinical Medical Physics, 2019
- AlignRT® and Catalyst™ in whole‐breast radiotherapy with DIBH: Is IGRT still needed?Journal of Applied Clinical Medical Physics, 2019
- Comparison of initial patient setup accuracy between surface imaging and three point localization: A retrospective analysisJournal of Applied Clinical Medical Physics, 2017
- Surface Reconstruction by Propagating 3D Stereo Data in Multiple 2D Images2004