Jacob S. Jordan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jacob S. Jordan has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Evan R. Williams
University of California
15 shared publications - Kevin Pagel
Freie Universität Berlin
7 shared publications Conner C. Harper
Department of Chemistry
6 shared publications- Katherine J. Lee
Department of Chemistry, University of California, Berkeley, California 94720-1460, United States
3 shared publications - Megha Ayachit
Freie Universität Berlin
3 shared publications - Emeline Hanozin
Department of Chemistry, University of California, Berkeley, California, 94720-1460, USA
2 shared publications
Latest Publications
- Open Access
- 5 November 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (45) , 31925-31936
Understanding Ion Transmission and m / z Bias in Orbitrap Mass Spectrometry
The analysis of high molecular weight or heterogeneous macromolecules is a significant analytical challenge. This is especially the case in mass spectrometry, where heterogeneity results in unresolved signal in m/z from which charge, and thus mass, information cannot be discerned. Recent developments in mass spectrometry-based approaches overcome these challenges by the simultaneous detection of m/z and charge, and their expanded application has been aided by the development of commercial instrument platforms for transmitting large, heterogeneous molecules. However, the characterization of heterogeneous species that span a broad range in m/z, such as glycoproteins, polysaccharides, or polymers, is still particularly challenging due to m/z bias that is induced by the conventional approach of tuning a mass spectrometer for optimal transmission over a narrow window in m/z. To assist MS users in understanding and characterizing this m/z bias, the reader is guided through the entire ion path of an Orbitrap UHMR mass spectrometer and explained the purpose and effect of each component on ion detection. On the basis of this knowledge, practical recommendations for instrument tuning are presented with the aim of mitigating m/z bias and standardizing mass spectrum data reporting. The main target audience of this tutorial are bio-, synthetic or analytical chemists with an interest in the characterization of heterogeneous molecules and mixtures, or scientists interested in understanding each of the factors that contribute to the generation of a mass spectrum on one of the most widely used commercial instrument platforms in the world.
- 5 November 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (45) , 31925-31936
Open AccessUnderstanding Ion Transmission and m / z Bias in Orbitrap Mass Spectrometry
The analysis of high molecular weight or heterogeneous macromolecules is a significant analytical challenge. This is especially the case in mass spectrometry, where heterogeneity results in unresolved signal in m/z from which charge, and thus mass, information cannot be discerned. Recent developments in mass spectrometry-based approaches overcome these challenges by the simultaneous detection of m/z and charge, and their expanded application has been aided by the development of commercial instrument platforms for transmitting large, heterogeneous molecules. However, the characterization of heterogeneous species that span a broad range in m/z, such as glycoproteins, polysaccharides, or polymers, is still particularly challenging due to m/z bias that is induced by the conventional approach of tuning a mass spectrometer for optimal transmission over a narrow window in m/z. To assist MS users in understanding and characterizing this m/z bias, the reader is guided through the entire ion path of an Orbitrap UHMR mass spectrometer and explained the purpose and effect of each component on ion detection. On the basis of this knowledge, practical recommendations for instrument tuning are presented with the aim of mitigating m/z bias and standardizing mass spectrum data reporting. The main target audience of this tutorial are bio-, synthetic or analytical chemists with an interest in the characterization of heterogeneous molecules and mixtures, or scientists interested in understanding each of the factors that contribute to the generation of a mass spectrum on one of the most widely used commercial instrument platforms in the world.
- Open Access
- 28 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (45) , 32007-32013
Charge Loss of Proteins in vacuo: Implications for Native Mass Spectrometry and Ion Mobility
Native ion mobility−mass spectrometry (IM−MS) is a powerful biophysical technique for characterizing protein structure. Because individual charge states often exhibit distinct structural dynamics, accurate IM-MS measurements require charge states to be examined independently. Although anecdotal reports among mass spectrometrists suggest that protein ions can lose charges during native IM-MS experiments, a thorough investigation of this phenomenon has been lacking. Here, we demonstrate that protein ions undergo charge loss inside the mass spectrometer as a direct consequence of gas-phase collisions, potentially leading to altered charge state distributions and ion mobility data. This effect was consistently observed across two instrument platforms (Synapt G2-S and Q Exactive UHMR), both ion polarities (positive and negative mode) and for three proteins (bovine serum albumin, myoglobin, and immunoglobulin G). Systematic investigations of instrumental parameters revealed that collision gas pressure has the strongest impact on the magnitude of charge loss, and that higher charge states are more affected than lower charge states. We further show that this process is largely driven by the dissociation of salt adducts and can hence be minimized through desalting in solution or inside the mass spectrometer, prior to the first m/z-analyzer (usually a quadrupole). For collision-induced unfolding experiments, significant differences were found between fingerprints acquired with and without quadrupole selection, although it remains unclear whether this phenomenon is directly related to charge loss. Overall, our study provides fundamental insights into collision-induced charge loss as a source of error in native IM-MS measurements and discusses the relevance of quadrupole m/z-selection for improving confidence in IM studies.
- 28 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (45) , 32007-32013
Open AccessCharge Loss of Proteins in vacuo: Implications for Native Mass Spectrometry and Ion Mobility
Native ion mobility−mass spectrometry (IM−MS) is a powerful biophysical technique for characterizing protein structure. Because individual charge states often exhibit distinct structural dynamics, accurate IM-MS measurements require charge states to be examined independently. Although anecdotal reports among mass spectrometrists suggest that protein ions can lose charges during native IM-MS experiments, a thorough investigation of this phenomenon has been lacking. Here, we demonstrate that protein ions undergo charge loss inside the mass spectrometer as a direct consequence of gas-phase collisions, potentially leading to altered charge state distributions and ion mobility data. This effect was consistently observed across two instrument platforms (Synapt G2-S and Q Exactive UHMR), both ion polarities (positive and negative mode) and for three proteins (bovine serum albumin, myoglobin, and immunoglobulin G). Systematic investigations of instrumental parameters revealed that collision gas pressure has the strongest impact on the magnitude of charge loss, and that higher charge states are more affected than lower charge states. We further show that this process is largely driven by the dissociation of salt adducts and can hence be minimized through desalting in solution or inside the mass spectrometer, prior to the first m/z-analyzer (usually a quadrupole). For collision-induced unfolding experiments, significant differences were found between fingerprints acquired with and without quadrupole selection, although it remains unclear whether this phenomenon is directly related to charge loss. Overall, our study provides fundamental insights into collision-induced charge loss as a source of error in native IM-MS measurements and discusses the relevance of quadrupole m/z-selection for improving confidence in IM studies.
- Open Access
- 5 August 2026
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
Stereoselectivity of Galactosylation Reactions In Vacuo
Controlling the stereoselective outcome of glycosidic bond formation remains a major challenge in chemical synthesis. This process typically proceeds along a complex SN1-SN2 mechanistic continuum. In solution, the key contributions to these mechanisms are difficult to determine due to influence by structural and environmental variables, such as solvents, counterions or temperature. To isolate the intrinsic factors driving steroselectivity in glycosylations, we investigate the reactions for the monosaccharide galactose in the gas phase. We perform ion–molecule galactosylation reactions in complete isolation inside an ion trap of a mass spectrometer and directly probe the stereochemistry of the formed products using mass-resolved ultraviolet cold ion spectroscopy. The results show that α-selectivity is significantly weaker in the gas phase than in solution, and that the product stereochemistry might be influenced by the nucleophile’s electron density rather than its overall nucleophilic strength.
- 5 August 2026
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
Open AccessStereoselectivity of Galactosylation Reactions In Vacuo
Controlling the stereoselective outcome of glycosidic bond formation remains a major challenge in chemical synthesis. This process typically proceeds along a complex SN1-SN2 mechanistic continuum. In solution, the key contributions to these mechanisms are difficult to determine due to influence by structural and environmental variables, such as solvents, counterions or temperature. To isolate the intrinsic factors driving steroselectivity in glycosylations, we investigate the reactions for the monosaccharide galactose in the gas phase. We perform ion–molecule galactosylation reactions in complete isolation inside an ion trap of a mass spectrometer and directly probe the stereochemistry of the formed products using mass-resolved ultraviolet cold ion spectroscopy. The results show that α-selectivity is significantly weaker in the gas phase than in solution, and that the product stereochemistry might be influenced by the nucleophile’s electron density rather than its overall nucleophilic strength.
- Open Access
- 5 August 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Extending Orbitrap Charge Detection Mass Spectrometry to Large Synthetic Polymers
Large dendritic and hyperbranched polymeric nanostructures are emerging as promising platforms for a variety of biomedical applications, but their high molecular weights, branching and intrinsic polydispersity make characterization challenging. Conventional approaches, such as multi-angle light scattering, provide ensemble-averaged information about the physical size of analytes from which the molecular weight is inferred. Charge detection mass spectrometry (CDMS) is a single particle technique that enables the direct measurement of mass for heterogeneous, high molecular weight analytes, but applications of CDMS to polymer systems have thus far relied on custom instrumentation available in select few laboratories. Here, we demonstrate that transmission and detection of intact megadalton (MDa)-sized branched polyglycerol polymers can be achieved on a commercial Orbitrap mass spectrometer. Under optimized conditions, CDMS measurements can determine the molecular weight, quantify polydispersity, and distinguish hyperbranched polymers with different architectures or terminal-group functionalization based on different charging behaviors. Comparisons with solution-phase multi-angle light-scattering results can be used to obtain information about the swelling behavior of dendritic nanostructures. Establishing CDMS analysis of such systems on a commercially available platform enables the direct characterization of the physical properties of polydisperse polymeric mixtures in laboratories worldwide.
- 5 August 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessExtending Orbitrap Charge Detection Mass Spectrometry to Large Synthetic Polymers
Large dendritic and hyperbranched polymeric nanostructures are emerging as promising platforms for a variety of biomedical applications, but their high molecular weights, branching and intrinsic polydispersity make characterization challenging. Conventional approaches, such as multi-angle light scattering, provide ensemble-averaged information about the physical size of analytes from which the molecular weight is inferred. Charge detection mass spectrometry (CDMS) is a single particle technique that enables the direct measurement of mass for heterogeneous, high molecular weight analytes, but applications of CDMS to polymer systems have thus far relied on custom instrumentation available in select few laboratories. Here, we demonstrate that transmission and detection of intact megadalton (MDa)-sized branched polyglycerol polymers can be achieved on a commercial Orbitrap mass spectrometer. Under optimized conditions, CDMS measurements can determine the molecular weight, quantify polydispersity, and distinguish hyperbranched polymers with different architectures or terminal-group functionalization based on different charging behaviors. Comparisons with solution-phase multi-angle light-scattering results can be used to obtain information about the swelling behavior of dendritic nanostructures. Establishing CDMS analysis of such systems on a commercially available platform enables the direct characterization of the physical properties of polydisperse polymeric mixtures in laboratories worldwide.
- Open Access
- 28 July 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Understanding Ion Transmission and m/z Bias in Orbitrap Mass Spectrometry
The analysis of high molecular weight or heterogeneous macromolecules is a significant analytical challenge. This is especially the case in mass spectrometry, where heterogeneity results in unresolved signal in m/z from which charge, and thus mass, information cannot be discerned. Recent developments in mass spectrometry-based approaches overcome these challenges by the simultaneous detection of m/z and charge, and their expanded application has been aided by the development of commercial instrument platforms for transmitting large, heterogeneous molecules. However, the characterization of heterogeneous species that span a broad range in m/z , such as glycoproteins, polysaccharides, or polymers, is still particularly challenging due to m/z -bias that is induced by the conventional approach of tuning a mass spectrometer for optimal transmission over a narrow window in m/z . To assist MS users in understanding and characterizing this m/z -bias, the reader is guided through the entire ion path of an Orbitrap UHMR mass spectrometer and explained the purpose and effect of each component on ion transmission. On the basis of this knowledge, practical recommendations for instrument tuning are presented with the aim of mitigating m/z bias and standardizing mass spectrum data reporting. The main target audience of this tutorial are bio-, synthetic or analytical chemists with an interest in the characterization of heterogeneous molecules and mixtures, or scientists interested in understanding each of the factors that contribute to the generation of a mass spectrum on one of the most widely used commercial instrument platforms in the world.
- 28 July 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessUnderstanding Ion Transmission and m/z Bias in Orbitrap Mass Spectrometry
The analysis of high molecular weight or heterogeneous macromolecules is a significant analytical challenge. This is especially the case in mass spectrometry, where heterogeneity results in unresolved signal in m/z from which charge, and thus mass, information cannot be discerned. Recent developments in mass spectrometry-based approaches overcome these challenges by the simultaneous detection of m/z and charge, and their expanded application has been aided by the development of commercial instrument platforms for transmitting large, heterogeneous molecules. However, the characterization of heterogeneous species that span a broad range in m/z , such as glycoproteins, polysaccharides, or polymers, is still particularly challenging due to m/z -bias that is induced by the conventional approach of tuning a mass spectrometer for optimal transmission over a narrow window in m/z . To assist MS users in understanding and characterizing this m/z -bias, the reader is guided through the entire ion path of an Orbitrap UHMR mass spectrometer and explained the purpose and effect of each component on ion transmission. On the basis of this knowledge, practical recommendations for instrument tuning are presented with the aim of mitigating m/z bias and standardizing mass spectrum data reporting. The main target audience of this tutorial are bio-, synthetic or analytical chemists with an interest in the characterization of heterogeneous molecules and mixtures, or scientists interested in understanding each of the factors that contribute to the generation of a mass spectrum on one of the most widely used commercial instrument platforms in the world.
- Open Access
- 28 December 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Cryogenic Gas-Phase IR Spectroscopy on a Commercial Ion Mobility-Mass Spectrometry Platform
The combination of gas-phase infrared (IR) spectroscopy with ion mobility spectrometry and mass spectrometry provides detailed, multi-dimensional structural information that facilitates the identification of unknown analytes. The instrumentation for performing these measurements is typically home-built and requires substantial expertise to operate. Here, we demonstrate messenger-tagging IR spectroscopy on a modified Synapt G2-S ion mobility-mass spectrometer. Messenger-tagging is performed in a commercially available cryogenic ion trap inserted between the exit of the transfer cell and the TOF pusher assembly and tagged ions are excited by IR light before MS measurement. We report the adjustments to the timing cycle and voltage gradient in the Synapt G2-S necessary for efficient trapping and messenger-tagging in the cryogenic trap. The capabilities of this instrument are demonstrated by measuring IM-MS-IR data for leucine enkephalin, a benchmark standard in mass spectrometry. The ability to selectively transmit ions of specific mobility enables the separation and subsequent IR spectroscopy of the isomeric trisaccharides cellotriose and melezitose. These data demonstrate the first implementation of messenger-tagging IR spectroscopy in a widely used, commercially available IM-MS system. The user-friendly implementation of these techniques overcomes a significant barrier to the widespread incorporation of orthogonal IR spectroscopy measurements in existing IM-MS workflows and will aid in distinguishing unknown molecules in untargeted -omics measurements.
- 28 December 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessCryogenic Gas-Phase IR Spectroscopy on a Commercial Ion Mobility-Mass Spectrometry Platform
The combination of gas-phase infrared (IR) spectroscopy with ion mobility spectrometry and mass spectrometry provides detailed, multi-dimensional structural information that facilitates the identification of unknown analytes. The instrumentation for performing these measurements is typically home-built and requires substantial expertise to operate. Here, we demonstrate messenger-tagging IR spectroscopy on a modified Synapt G2-S ion mobility-mass spectrometer. Messenger-tagging is performed in a commercially available cryogenic ion trap inserted between the exit of the transfer cell and the TOF pusher assembly and tagged ions are excited by IR light before MS measurement. We report the adjustments to the timing cycle and voltage gradient in the Synapt G2-S necessary for efficient trapping and messenger-tagging in the cryogenic trap. The capabilities of this instrument are demonstrated by measuring IM-MS-IR data for leucine enkephalin, a benchmark standard in mass spectrometry. The ability to selectively transmit ions of specific mobility enables the separation and subsequent IR spectroscopy of the isomeric trisaccharides cellotriose and melezitose. These data demonstrate the first implementation of messenger-tagging IR spectroscopy in a widely used, commercially available IM-MS system. The user-friendly implementation of these techniques overcomes a significant barrier to the widespread incorporation of orthogonal IR spectroscopy measurements in existing IM-MS workflows and will aid in distinguishing unknown molecules in untargeted -omics measurements.
- Open Access
- 23 October 2025
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 16 (47) , 22407-22416
Mass spectrometry detects folding intermediates populated during urea-induced protein denaturation
Protein folding stability can be probed using urea, a chaotropic agent that disrupts non-covalent interactions at molar concentrations. The denaturation process is typically monitored via optical spectroscopy, which provides ensemble-averaged measurements and may struggle to resolve folding intermediates. In contrast, electrospray ionization mass spectrometry (ESI-MS) captures a non-averaged snapshot of all populated assembly and folding states within a protein conformational ensemble. However, high urea concentrations have traditionally been considered incompatible with ESI. Here, we leverage recent advancements in nano ESI emitter design, utilizing well-defined small-diameter emitters which enables protein charge states to be resolved from solutions containing up to 8 M urea. This approach allows us to directly detect the disruption of native tertiary and quaternary structures and to monitor stability changes in response to solution pH and ligand binding. We demonstrate this using single-domain proteins that follow simple two-state unfolding pathways, as well as more complex multidomain proteins and multimeric protein complexes. Our results show strong agreement with conventional urea–denaturation curves obtained via optical spectroscopy, while also providing enhanced resolution of intermediate folding and assembly states that are challenging to capture using traditional methods.
- 23 October 2025
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 16 (47) , 22407-22416
Open AccessMass spectrometry detects folding intermediates populated during urea-induced protein denaturation
Protein folding stability can be probed using urea, a chaotropic agent that disrupts non-covalent interactions at molar concentrations. The denaturation process is typically monitored via optical spectroscopy, which provides ensemble-averaged measurements and may struggle to resolve folding intermediates. In contrast, electrospray ionization mass spectrometry (ESI-MS) captures a non-averaged snapshot of all populated assembly and folding states within a protein conformational ensemble. However, high urea concentrations have traditionally been considered incompatible with ESI. Here, we leverage recent advancements in nano ESI emitter design, utilizing well-defined small-diameter emitters which enables protein charge states to be resolved from solutions containing up to 8 M urea. This approach allows us to directly detect the disruption of native tertiary and quaternary structures and to monitor stability changes in response to solution pH and ligand binding. We demonstrate this using single-domain proteins that follow simple two-state unfolding pathways, as well as more complex multidomain proteins and multimeric protein complexes. Our results show strong agreement with conventional urea–denaturation curves obtained via optical spectroscopy, while also providing enhanced resolution of intermediate folding and assembly states that are challenging to capture using traditional methods.
- 24 March 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (8) , 1605-1616
High performance charge detection mass spectrometry without ultra-high vacuum
Charge detection mass spectrometry (CDMS) measurements of individual ions using either Orbitrap or electrostatic ion trap-based instruments have heretofore been performed under ultra-high vacuum conditions (10−9 Torr or lower). The rationale for this expensive and often cumbersome requirement is that these measurements need to be performed in an environment where collisions with background gas do not adversely affect the measurements. Here, the use of an electrostatic trap that accepts a broad range of ion energies and a dynamic ion signal analysis method enables accurate CDMS mass measurements at pressures as high as 1 × 10−6 Torr, multiple orders of magnitude higher than previously demonstrated. Consistent, accurate masses were obtained for pentameric antibody complexes (∼800 kDa), adeno-associated viruses (∼4.8 MDa), and both ∼50 and ∼100 nm diameter polystyrene nanoparticles (∼35 MDa and ∼330 MDa, respectively) at pressures ranging from 1 × 10−8 Torr to 1 × 10−6 Torr. The relationships between ion mass, trap pressure, ion lifetimes, individual ion energies and survival rates were investigated over a 1 s trapping period. Larger ions are more robust to higher pressures. While the trapping lifetimes of smaller ions decrease with increasing pressure, enough survive long enough for accurate mass measurements to be made. Some ions are lost because collisional dampening decreases their energies below the minimum stability threshold of the trap, but others with sufficient energy are still lost due to collision-induced scattering that moves the ions too far from the central trapping axis.
- 24 March 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (8) , 1605-1616
High performance charge detection mass spectrometry without ultra-high vacuum
Charge detection mass spectrometry (CDMS) measurements of individual ions using either Orbitrap or electrostatic ion trap-based instruments have heretofore been performed under ultra-high vacuum conditions (10−9 Torr or lower). The rationale for this expensive and often cumbersome requirement is that these measurements need to be performed in an environment where collisions with background gas do not adversely affect the measurements. Here, the use of an electrostatic trap that accepts a broad range of ion energies and a dynamic ion signal analysis method enables accurate CDMS mass measurements at pressures as high as 1 × 10−6 Torr, multiple orders of magnitude higher than previously demonstrated. Consistent, accurate masses were obtained for pentameric antibody complexes (∼800 kDa), adeno-associated viruses (∼4.8 MDa), and both ∼50 and ∼100 nm diameter polystyrene nanoparticles (∼35 MDa and ∼330 MDa, respectively) at pressures ranging from 1 × 10−8 Torr to 1 × 10−6 Torr. The relationships between ion mass, trap pressure, ion lifetimes, individual ion energies and survival rates were investigated over a 1 s trapping period. Larger ions are more robust to higher pressures. While the trapping lifetimes of smaller ions decrease with increasing pressure, enough survive long enough for accurate mass measurements to be made. Some ions are lost because collisional dampening decreases their energies below the minimum stability threshold of the trap, but others with sufficient energy are still lost due to collision-induced scattering that moves the ions too far from the central trapping axis.
- 8 January 2025
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 147 (4) , 3412-3420
Temperature Induced Unfolding and Compaction of Cytochrome c in the Same Aqueous Solutions
Most conventional methods used to measure protein melting temperatures reflect changes in structure between different conformational states and are typically fit to a two-state model. Population abundances of distinct conformations were measured using variable-temperature electrospray ionization ion mobility mass spectrometry to investigate the thermally induced unfolding of the model protein cytochrome c. Nineteen conformers formed at high temperature have elongated structures, consistent with unfolded forms of this protein. However, one conformer that is more compact than the native state of the protein is also formed from this same solution upon heating. The abundance of this compact conformer increases with temperatures up to 90 °C. Rapid mixing and collision-induced gas-phase unfolding experiments demonstrate that formation of this compact conformer is not an artifact of rapid refolding during the ESI process or structural rearrangement in the gas-phase, and therefore the compact conformer must be formed in bulk solution at higher temperatures. The main folded conformer at 90 °C has a cross section that is ∼30 Å2 larger than that at 27 °C. Results from collision-induced unfolding experiments indicate that they have different gas-phase stabilities that are not directly related to differences in their initial internal energies upon transitioning into the gas phase and therefore have different structures. These results demonstrate the advantage of mass and ion mobility measurements for investigating protein conformational landscapes and provide the first evidence for formation of both unfolded and more compact conformations of a protein from the same solution upon heating.
- 8 January 2025
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 147 (4) , 3412-3420
Temperature Induced Unfolding and Compaction of Cytochrome c in the Same Aqueous Solutions
Most conventional methods used to measure protein melting temperatures reflect changes in structure between different conformational states and are typically fit to a two-state model. Population abundances of distinct conformations were measured using variable-temperature electrospray ionization ion mobility mass spectrometry to investigate the thermally induced unfolding of the model protein cytochrome c. Nineteen conformers formed at high temperature have elongated structures, consistent with unfolded forms of this protein. However, one conformer that is more compact than the native state of the protein is also formed from this same solution upon heating. The abundance of this compact conformer increases with temperatures up to 90 °C. Rapid mixing and collision-induced gas-phase unfolding experiments demonstrate that formation of this compact conformer is not an artifact of rapid refolding during the ESI process or structural rearrangement in the gas-phase, and therefore the compact conformer must be formed in bulk solution at higher temperatures. The main folded conformer at 90 °C has a cross section that is ∼30 Å2 larger than that at 27 °C. Results from collision-induced unfolding experiments indicate that they have different gas-phase stabilities that are not directly related to differences in their initial internal energies upon transitioning into the gas phase and therefore have different structures. These results demonstrate the advantage of mass and ion mobility measurements for investigating protein conformational landscapes and provide the first evidence for formation of both unfolded and more compact conformations of a protein from the same solution upon heating.
- 26 December 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (3) , 3414-3423
Understanding the Formation Dynamics and Physical Properties of Nanocapsules Using Charge Detection Mass Spectrometry
Characterizing the size, structure, and composition of nanoparticles is vital in predicting and understanding their macroscopic properties. In this work, charge detection mass spectrometry (CDMS) was used to analyze nanocapsules (∼10-200 MDa) consisting of a liquid oleic acid core surrounded by a dense silica outer shell. CDMS is an emerging method for nanoparticle analysis that can rapidly measure the mass and charge of thousands of individual nanoparticles. We find that increasing the feed volume of the tetraethylorthosilicate (TEOS) precursor added to form the silica shell of the nanocapsules yielded both higher and broader nanocapsule mass distributions with differentiable densities. A two-dimensional mass versus charge analysis also revealed the formation of two distinct populations of nanocapsules. These two nanocapsule morphologies were also present in transmission electron microscopy (TEM) images and exhibited low-density spherical cores and crescent-shaped cores where the remainder of the core volume was "filled in" by more dense silica. Nanocapsule shell growth kinetics over a ∼48-h synthesis period were also monitored by sampling the reaction mixture at various times, quenching the sampled aliquots, and then characterizing these time-resolved samples by CDMS. The CDMS data reveal three distinct growth phases in nanocapsule formation; rapid initial nucleation, an "inverted" distribution of silica growth, and a final slow growth phase where the rate of mass increase and final nanocapsule masses are dictated by the initial TEOS feed volumes. CDMS-enabled understanding of the diverse nanocapsule sizes, morphologies, and growth dynamics will allow us to better predict nanocapsule properties while reducing the experimental burden in optimizing nanocapsules for real-world applications.
- 26 December 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (3) , 3414-3423
Understanding the Formation Dynamics and Physical Properties of Nanocapsules Using Charge Detection Mass Spectrometry
Characterizing the size, structure, and composition of nanoparticles is vital in predicting and understanding their macroscopic properties. In this work, charge detection mass spectrometry (CDMS) was used to analyze nanocapsules (∼10-200 MDa) consisting of a liquid oleic acid core surrounded by a dense silica outer shell. CDMS is an emerging method for nanoparticle analysis that can rapidly measure the mass and charge of thousands of individual nanoparticles. We find that increasing the feed volume of the tetraethylorthosilicate (TEOS) precursor added to form the silica shell of the nanocapsules yielded both higher and broader nanocapsule mass distributions with differentiable densities. A two-dimensional mass versus charge analysis also revealed the formation of two distinct populations of nanocapsules. These two nanocapsule morphologies were also present in transmission electron microscopy (TEM) images and exhibited low-density spherical cores and crescent-shaped cores where the remainder of the core volume was "filled in" by more dense silica. Nanocapsule shell growth kinetics over a ∼48-h synthesis period were also monitored by sampling the reaction mixture at various times, quenching the sampled aliquots, and then characterizing these time-resolved samples by CDMS. The CDMS data reveal three distinct growth phases in nanocapsule formation; rapid initial nucleation, an "inverted" distribution of silica growth, and a final slow growth phase where the rate of mass increase and final nanocapsule masses are dictated by the initial TEOS feed volumes. CDMS-enabled understanding of the diverse nanocapsule sizes, morphologies, and growth dynamics will allow us to better predict nanocapsule properties while reducing the experimental burden in optimizing nanocapsules for real-world applications.