MAMegha Ayachit

Megha Ayachit

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Megha Ayachit has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Understanding Ion Transmission and m / z Bias in Orbitrap Mass Spectrometry

    by Megha Ayachit, Kevin Pagel, Jacob S. Jordan

    The analysis of high molecular weight or heterogeneous macromolecules is a significant analytical challenge. This is especially the case in mass spectrometry, where heterogeneity results in unresolved signal in m/z from which charge, and thus mass, information cannot be discerned. Recent developments in mass spectrometry-based approaches overcome these challenges by the simultaneous detection of m/z and charge, and their expanded application has been aided by the development of commercial instrument platforms for transmitting large, heterogeneous molecules. However, the characterization of heterogeneous species that span a broad range in m/z, such as glycoproteins, polysaccharides, or polymers, is still particularly challenging due to m/z bias that is induced by the conventional approach of tuning a mass spectrometer for optimal transmission over a narrow window in m/z. To assist MS users in understanding and characterizing this m/z bias, the reader is guided through the entire ion path of an Orbitrap UHMR mass spectrometer and explained the purpose and effect of each component on ion detection. On the basis of this knowledge, practical recommendations for instrument tuning are presented with the aim of mitigating m/z bias and standardizing mass spectrum data reporting. The main target audience of this tutorial are bio-, synthetic or analytical chemists with an interest in the characterization of heterogeneous molecules and mixtures, or scientists interested in understanding each of the factors that contribute to the generation of a mass spectrum on one of the most widely used commercial instrument platforms in the world.

  • Open Access

    Extending Orbitrap Charge Detection Mass Spectrometry to Large Synthetic Polymers

    by Jacob S. Jordan, Megha Ayachit, Nico Gino Kub, Ehsan Mohammadifar, Irina Chafeeva, Jayachandran N. Kizhakkedathu, Rainer Haag, Kevin Pagel

    Large dendritic and hyperbranched polymeric nanostructures are emerging as promising platforms for a variety of biomedical applications, but their high molecular weights, branching and intrinsic polydispersity make characterization challenging. Conventional approaches, such as multi-angle light scattering, provide ensemble-averaged information about the physical size of analytes from which the molecular weight is inferred. Charge detection mass spectrometry (CDMS) is a single particle technique that enables the direct measurement of mass for heterogeneous, high molecular weight analytes, but applications of CDMS to polymer systems have thus far relied on custom instrumentation available in select few laboratories. Here, we demonstrate that transmission and detection of intact megadalton (MDa)-sized branched polyglycerol polymers can be achieved on a commercial Orbitrap mass spectrometer. Under optimized conditions, CDMS measurements can determine the molecular weight, quantify polydispersity, and distinguish hyperbranched polymers with different architectures or terminal-group functionalization based on different charging behaviors. Comparisons with solution-phase multi-angle light-scattering results can be used to obtain information about the swelling behavior of dendritic nanostructures. Establishing CDMS analysis of such systems on a commercially available platform enables the direct characterization of the physical properties of polydisperse polymeric mixtures in laboratories worldwide.


  • Open Access

    Understanding Ion Transmission and m/z Bias in Orbitrap Mass Spectrometry

    by Megha Ayachit, Kevin Pagel, Jacob S. Jordan

    The analysis of high molecular weight or heterogeneous macromolecules is a significant analytical challenge. This is especially the case in mass spectrometry, where heterogeneity results in unresolved signal in m/z from which charge, and thus mass, information cannot be discerned. Recent developments in mass spectrometry-based approaches overcome these challenges by the simultaneous detection of m/z and charge, and their expanded application has been aided by the development of commercial instrument platforms for transmitting large, heterogeneous molecules. However, the characterization of heterogeneous species that span a broad range in m/z , such as glycoproteins, polysaccharides, or polymers, is still particularly challenging due to m/z -bias that is induced by the conventional approach of tuning a mass spectrometer for optimal transmission over a narrow window in m/z . To assist MS users in understanding and characterizing this m/z -bias, the reader is guided through the entire ion path of an Orbitrap UHMR mass spectrometer and explained the purpose and effect of each component on ion transmission. On the basis of this knowledge, practical recommendations for instrument tuning are presented with the aim of mitigating m/z bias and standardizing mass spectrum data reporting. The main target audience of this tutorial are bio-, synthetic or analytical chemists with an interest in the characterization of heterogeneous molecules and mixtures, or scientists interested in understanding each of the factors that contribute to the generation of a mass spectrum on one of the most widely used commercial instrument platforms in the world.

  • Open Access

    Stabilizing a mammalian RNA thermometer confers neuroprotection in subarachnoid hemorrhage

    by Min Zhang, Bin Zhang, Chengli Liu, Marco Preußner, Megha Ayachit, Weiming Li, Yafei Huang, Deyi Liu, Quanwei He, Ann-Kathrin Emmerichs, et al.

    Mammals tightly regulate their core body temperature, yet how cells sense and respond to small temperature changes remains incompletely understood. Here, we discover RNA G-quadruplexes (rG4s) as key thermosensors enriched near splice sites of cold-repressed exons. These thermosensing RNA structures, when stabilized, mask splice sites, reducing exon inclusion. Specifically, rG4s near splice sites of a cold-repressed poison exon in the neuroprotective RBM3 are stabilized at low temperatures, leading to exon exclusion. This enables evasion of nonsense-mediated decay, increasing RBM3 expression at cold. Importantly, stabilizing rG4 through increasing intracellular potassium with an FDA-approved potassium channel blocker, mimics the hypothermic effect on alternative splicing, thereby increasing RBM3 expression, leading to RBM3-dependent neuroprotection in a mouse model of subarachnoid hemorrhage. Our findings unveil a mechanism how mammalian RNAs directly sense temperature and potassium perturbations, integrating them into gene expression programs. This opens new avenues for treating diseases arising from splicing defects and disorders benefiting from therapeutic hypothermia, especially hemorrhagic stroke.