Limei Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Limei Han has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Oliver Jens Lechtenfeld
Helmholtz Centre for Environmental Research - UFZ
4 shared publications - Thorsten Reemtsma
Department of Environmental Analytical Chemistry, Helmholtz Centre for Environmental Research - UFZ, Permoserstraße 15, 04318 Leipzig, Germany
3 shared publications - Elaine K. Jennings
Department Environmental Analytical Chemistry, Helmholtz Centre for Environmental Research−UFZ, Permoserstrasse 15, 04318 Leipzig, Germany
2 shared publications Arina Kremser
Department of Analytical Chemistry, Helmholtz Centre for Environmental Research−UFZ, Permoserstrasse 15, 04318 Leipzig, Germany
1 shared publication- Boris Peter Koch
Alfred-Wegener-Institut Helmholtz Zentrum für Polar- und Meeresforschung
1 shared publication Chang Peng
Institute of Analytical Chemistry, University of Leipzig, 04103 Leipzig, Germany
1 shared publication
Latest Publications
- Open Access
- 13 June 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (25) , 10210-10218
Detection and Exclusion of False-Positive Molecular Formula Assignments via Mass Error Distributions in UHR Mass Spectra of Natural Organic Matter
Ultrahigh resolution mass spectrometry (UHRMS) routinely detects and identifies thousands of mass peaks in complex mixtures, such as natural organic matter (NOM) and petroleum. The assignment of several chemically plausible molecular formulas (MFs) for a single accurate mass still poses a major problem for the reliable interpretation of NOM composition in a biogeochemical context. Applying sensible chemical rules for MF validation is often insufficient to eliminate multiple assignments (MultiAs)─especially for mass peaks with low abundance or if ample heteroatoms or isotopes are included - and requires manual inspection or expert judgment. Here, we present a new approach based on mass error distributions for the identification of true and false assignments among MultiAs. To this end, we used the mass error in millidalton (mDa), which was superior to the commonly used relative mass error in ppm. We developed an automatic workflow to group MultiAs based on their shared formula units and Kendrick mass defect values and to evaluate the mass error distribution. In this way, the number of valid assignments of chlorinated disinfection byproducts was increased by 8-fold as compared to only applying 37Cl/35Cl isotope ratio filters. Likewise, phosphorus-containing MFs can be differentiated against chlorine-containing MFs with high confidence. Further, false assignments of highly aromatic sulfur-containing MFs ("black sulfur") to sodium adducts in negative ionization mode can be excluded by applying our approach. Overall, MFs for mass peaks that are close to the detection limit or where naturally occurring isotopes are rare (e.g., 15N) or absent (e.g., P and F) can now be validated, substantially increasing the reliability of MF assignments and broadening the applicability of UHRMS analysis to even more complex samples and processes.
- 13 June 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (25) , 10210-10218
Open AccessDetection and Exclusion of False-Positive Molecular Formula Assignments via Mass Error Distributions in UHR Mass Spectra of Natural Organic Matter
Ultrahigh resolution mass spectrometry (UHRMS) routinely detects and identifies thousands of mass peaks in complex mixtures, such as natural organic matter (NOM) and petroleum. The assignment of several chemically plausible molecular formulas (MFs) for a single accurate mass still poses a major problem for the reliable interpretation of NOM composition in a biogeochemical context. Applying sensible chemical rules for MF validation is often insufficient to eliminate multiple assignments (MultiAs)─especially for mass peaks with low abundance or if ample heteroatoms or isotopes are included - and requires manual inspection or expert judgment. Here, we present a new approach based on mass error distributions for the identification of true and false assignments among MultiAs. To this end, we used the mass error in millidalton (mDa), which was superior to the commonly used relative mass error in ppm. We developed an automatic workflow to group MultiAs based on their shared formula units and Kendrick mass defect values and to evaluate the mass error distribution. In this way, the number of valid assignments of chlorinated disinfection byproducts was increased by 8-fold as compared to only applying 37Cl/35Cl isotope ratio filters. Likewise, phosphorus-containing MFs can be differentiated against chlorine-containing MFs with high confidence. Further, false assignments of highly aromatic sulfur-containing MFs ("black sulfur") to sodium adducts in negative ionization mode can be excluded by applying our approach. Overall, MFs for mass peaks that are close to the detection limit or where naturally occurring isotopes are rare (e.g., 15N) or absent (e.g., P and F) can now be validated, substantially increasing the reliability of MF assignments and broadening the applicability of UHRMS analysis to even more complex samples and processes.
- Open Access
- 15 May 2023
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 9 (6) , 1729-1737
Direct non-target analysis of dissolved organic matter and disinfection by-products in drinking water with nano-LC-FT-ICR-MS
Detection of DBPs directly from only 1 μL of drinking water provides novel and less biased insights of DBP formation and their chemical properties.
- 15 May 2023
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 9 (6) , 1729-1737
Open AccessDirect non-target analysis of dissolved organic matter and disinfection by-products in drinking water with nano-LC-FT-ICR-MS
Detection of DBPs directly from only 1 μL of drinking water provides novel and less biased insights of DBP formation and their chemical properties.
- Open Access
- 10 January 2022
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 56 (3) , 1894-1904
Discovery of Polar Ozonation Byproducts via Direct Injection of Effluent Organic Matter with Online LC-FT-ICR-MS
Effluent organic matter (EfOM), a major ozone consumer during wastewater ozonation, is a complex mixture of natural and anthropogenic organic molecules. Ozonation of EfOM adds to molecular complexity by introducing polar and potentially mobile ozonation byproducts (OBPs). Currently, nontargeted direct infusion (DI) ultrahigh resolution mass spectrometry (e.g. FT-ICR-MS) is used to study OBPs but requires sample extraction, limiting the accessible polarity range of OBPs. To better understand the impact of ozonation on EfOM and the formation of polar OBPs, nonextracted effluent was analyzed by direct injection onto a reversed-phase liquid chromatography system (RP-LC) online hyphenated with an FT-ICR-MS. Over four times more OBPs were detected in nonextracted EfOM compared to effluent extracted with solid phase extraction and measured with DI-FT-ICR-MS (13817 vs 3075). Over 1500 highly oxygenated OBPs were detected exclusively in early eluting fractions of nonextracted EfOM, indicating polar OBPs. Oxygenation of these newly discovered OBPs is higher than previously found, with an average molecular DBE-O value of −3.3 and O/C ratio of 0.84 in the earliest eluting OBP fractions. These polar OBPs are consistently lost during extraction but may play an important role in understanding the environmental impact of ozonated EfOM. Moreover, 316 molecular formulas classified as nonreactive to ozone in DI-FT-ICR-MS can be identified with LC-FT-ICR-MS as isomers with varying degrees of reactivity, providing for the first time experimental evidence of differential reactivity of complex organic matter isomers with ozone.
- 10 January 2022
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 56 (3) , 1894-1904
Open AccessDiscovery of Polar Ozonation Byproducts via Direct Injection of Effluent Organic Matter with Online LC-FT-ICR-MS
Effluent organic matter (EfOM), a major ozone consumer during wastewater ozonation, is a complex mixture of natural and anthropogenic organic molecules. Ozonation of EfOM adds to molecular complexity by introducing polar and potentially mobile ozonation byproducts (OBPs). Currently, nontargeted direct infusion (DI) ultrahigh resolution mass spectrometry (e.g. FT-ICR-MS) is used to study OBPs but requires sample extraction, limiting the accessible polarity range of OBPs. To better understand the impact of ozonation on EfOM and the formation of polar OBPs, nonextracted effluent was analyzed by direct injection onto a reversed-phase liquid chromatography system (RP-LC) online hyphenated with an FT-ICR-MS. Over four times more OBPs were detected in nonextracted EfOM compared to effluent extracted with solid phase extraction and measured with DI-FT-ICR-MS (13817 vs 3075). Over 1500 highly oxygenated OBPs were detected exclusively in early eluting fractions of nonextracted EfOM, indicating polar OBPs. Oxygenation of these newly discovered OBPs is higher than previously found, with an average molecular DBE-O value of −3.3 and O/C ratio of 0.84 in the earliest eluting OBP fractions. These polar OBPs are consistently lost during extraction but may play an important role in understanding the environmental impact of ozonated EfOM. Moreover, 316 molecular formulas classified as nonreactive to ozone in DI-FT-ICR-MS can be identified with LC-FT-ICR-MS as isomers with varying degrees of reactivity, providing for the first time experimental evidence of differential reactivity of complex organic matter isomers with ozone.
- 28 December 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (3) , 1740-1748
Online Counter Gradient LC-FT-ICR-MS Enables Detection of Highly Polar Natural Organic Matter Fractions
Natural organic matter (NOM) is a highly complex mixture of natural organic molecules. The recent developments in NOM molecular characterization methods have shown that ESI-FT-ICR hyphenated with liquid chromatography (LC) is a promising approach to also obtain chemical information (such as polarity and molecular size) about NOM molecules. However, due to changing solvent composition during gradient elution in LC-FT-ICR-MS, ionization conditions also change throughout the chromatographic separation process. In this study, we applied a post-LC column counter gradient (CG) to ensure stable solvent conditions for transient ESI-MS signals. Suwanee River Fulvic Acid (SRFA) standard and a peat pore water were used as representative dissolved NOM samples for method development and validation. Our results show that in polar NOM fractions (which elute with 0.6) were more than 20 times larger for CG-LC mode as compared to direct infusion (DI) (5715 vs 266 MF). We conclude that the application of a postcolumn counter gradient in LC-FT-ICR-MS analyses of NOM offers novel insight into the most polar fractions of NOM which are inaccessible in conventional DI measurements.
- 28 December 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (3) , 1740-1748
Online Counter Gradient LC-FT-ICR-MS Enables Detection of Highly Polar Natural Organic Matter Fractions
Natural organic matter (NOM) is a highly complex mixture of natural organic molecules. The recent developments in NOM molecular characterization methods have shown that ESI-FT-ICR hyphenated with liquid chromatography (LC) is a promising approach to also obtain chemical information (such as polarity and molecular size) about NOM molecules. However, due to changing solvent composition during gradient elution in LC-FT-ICR-MS, ionization conditions also change throughout the chromatographic separation process. In this study, we applied a post-LC column counter gradient (CG) to ensure stable solvent conditions for transient ESI-MS signals. Suwanee River Fulvic Acid (SRFA) standard and a peat pore water were used as representative dissolved NOM samples for method development and validation. Our results show that in polar NOM fractions (which elute with 0.6) were more than 20 times larger for CG-LC mode as compared to direct infusion (DI) (5715 vs 266 MF). We conclude that the application of a postcolumn counter gradient in LC-FT-ICR-MS analyses of NOM offers novel insight into the most polar fractions of NOM which are inaccessible in conventional DI measurements.