Elaine K. Jennings
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Elaine K. Jennings has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Oliver Jens Lechtenfeld
Helmholtz Centre for Environmental Research - UFZ
7 shared publications - Boris Peter Koch
Alfred-Wegener-Institut Helmholtz Zentrum für Polar- und Meeresforschung
4 shared publications - Thorsten Reemtsma
Department of Environmental Analytical Chemistry, Helmholtz Centre for Environmental Research - UFZ, Permoserstraße 15, 04318 Leipzig, Germany
3 shared publications - Limei Han
Department Environmental Analytical Chemistry, Research Group BioGeoOmics, Helmholtz Centre for Environmental Research─UFZ, Permoserstr. 15, Leipzig D-04318, Germany
2 shared publications - Millaray Sierra Olea
Chair of Urban Water Systems Engineering, Technical University of Munich, Am Coulombwall 3, Garching D-85748, Germany
2 shared publications - Peter Herzsprung
Helmholtz Centre for Environmental Research - UFZ Brückstr. 3a
2 shared publications
Latest Publications
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Detection and exclusion of false molecular formula assignments via mass error distributions in ultrahigh resolution mass spectra from natural organic matter.
Ultrahigh resolution mass spectrometry (UHRMS) routinely detects and identifies thousands of molecular formulas (MFs) in natural organic matter (NOM). However, multiple assignments (MultiAs) occur when the several chemically plausible MFs are assigned to one single mass peak. MultiAs for a mass peak consist of one common core MF but different “formula residuals”, or replacement pairs, and increase as more heteroatoms and isotopes are being considered during the assignment process. This poses a major problem for the reliable interpretation of NOM composition in a biogeochemical context. A number of approaches have been proposed to rule out false assignments based on structural constraints or isotopologue detection and intensity ratios. But this becomes increasingly challenging for low abundance mass peaks or when stable isotope labeling (e.g. with 15N, 2H) is employed. Here, we present a new approach based on mass error distributions for the identification of true and false-assignments among MultiAs. An automatic workflow was developed for the detection and exclusion of false assignments in MultiAs based on their recurring replacement pairs and Kendrick mass defect values. The workflow can validate MFs for mass peaks that are close to detection limit or where naturally occurring isotopes are rare (e.g. 15N) or absent (e.g. P, F), substantially increasing the reliability of MFs assignments and broadening the applicability of UHRMS in characterization of NOM, e.g. for organic nitrogen and organic phosphorus in different environmental compartments, which are key components for global elemental cycles.
- 20 January 2025
- Published by Copernicus GmbH
Open AccessDetection and exclusion of false molecular formula assignments via mass error distributions in ultrahigh resolution mass spectra from natural organic matter.
Ultrahigh resolution mass spectrometry (UHRMS) routinely detects and identifies thousands of molecular formulas (MFs) in natural organic matter (NOM). However, multiple assignments (MultiAs) occur when the several chemically plausible MFs are assigned to one single mass peak. MultiAs for a mass peak consist of one common core MF but different “formula residuals”, or replacement pairs, and increase as more heteroatoms and isotopes are being considered during the assignment process. This poses a major problem for the reliable interpretation of NOM composition in a biogeochemical context. A number of approaches have been proposed to rule out false assignments based on structural constraints or isotopologue detection and intensity ratios. But this becomes increasingly challenging for low abundance mass peaks or when stable isotope labeling (e.g. with 15N, 2H) is employed. Here, we present a new approach based on mass error distributions for the identification of true and false-assignments among MultiAs. An automatic workflow was developed for the detection and exclusion of false assignments in MultiAs based on their recurring replacement pairs and Kendrick mass defect values. The workflow can validate MFs for mass peaks that are close to detection limit or where naturally occurring isotopes are rare (e.g. 15N) or absent (e.g. P, F), substantially increasing the reliability of MFs assignments and broadening the applicability of UHRMS in characterization of NOM, e.g. for organic nitrogen and organic phosphorus in different environmental compartments, which are key components for global elemental cycles.
- Open Access
- 23 December 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (1) , 823-833
Molecular-Level Insights into Recalcitrant Ozonation Products from Effluent Organic Matter
Wastewater ozonation is commonly employed to enhance the subsequent biodegradation of effluent organic matter (EfOM) and contaminants of concern. However, there is evidence suggesting the formation of recalcitrant ozonation products (OPs) from EfOM. To investigate the biodegradability of OPs we conducted batch biodegradation experiments using wastewater effluent ozonated with mass-labeled (18O) ozone. Molecular level analysis of EfOM was performed using reversed-phase liquid chromatography coupled with Fourier transform ion cyclotron resonance mass spectrometry (LC-FT-ICR MS) after 3 and 28 days in batch bioreactors. The use of mass labeling allowed for the unambiguous detection of OPs, with 2933 labeled OP features identified in the ozonated EfOM. Furthermore, employing polarity separation with LC facilitated the investigation of reactivity among different OP isomers. Overall, OPs exhibited a comparable proportion of recalcitrant and bioproduced molecular formulas when compared to the remaining EfOM, with 12% of OPs classified as recalcitrant and 17% bioproduced, indicating that OPs themselves are not inherently biodegradable. Additionally, recalcitrant OPs were found to be more polar based on the O/C ratios and retention time, in comparison to biodegradable OPs. Approximately one-third of the OP isomers displayed variations in their biodegradability, suggesting that studying the degradability of ozonated EfOM at the molecular formula level is heavily influenced by structural differences. Here, we offer unique insight into the biological transformation of EfOM after ozonation using labeled ozone and LC-FT-ICR MS analysis.
- 23 December 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (1) , 823-833
Open AccessMolecular-Level Insights into Recalcitrant Ozonation Products from Effluent Organic Matter
Wastewater ozonation is commonly employed to enhance the subsequent biodegradation of effluent organic matter (EfOM) and contaminants of concern. However, there is evidence suggesting the formation of recalcitrant ozonation products (OPs) from EfOM. To investigate the biodegradability of OPs we conducted batch biodegradation experiments using wastewater effluent ozonated with mass-labeled (18O) ozone. Molecular level analysis of EfOM was performed using reversed-phase liquid chromatography coupled with Fourier transform ion cyclotron resonance mass spectrometry (LC-FT-ICR MS) after 3 and 28 days in batch bioreactors. The use of mass labeling allowed for the unambiguous detection of OPs, with 2933 labeled OP features identified in the ozonated EfOM. Furthermore, employing polarity separation with LC facilitated the investigation of reactivity among different OP isomers. Overall, OPs exhibited a comparable proportion of recalcitrant and bioproduced molecular formulas when compared to the remaining EfOM, with 12% of OPs classified as recalcitrant and 17% bioproduced, indicating that OPs themselves are not inherently biodegradable. Additionally, recalcitrant OPs were found to be more polar based on the O/C ratios and retention time, in comparison to biodegradable OPs. Approximately one-third of the OP isomers displayed variations in their biodegradability, suggesting that studying the degradability of ozonated EfOM at the molecular formula level is heavily influenced by structural differences. Here, we offer unique insight into the biological transformation of EfOM after ozonation using labeled ozone and LC-FT-ICR MS analysis.
- Open Access
- 13 June 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (25) , 10210-10218
Detection and Exclusion of False-Positive Molecular Formula Assignments via Mass Error Distributions in UHR Mass Spectra of Natural Organic Matter
Ultrahigh resolution mass spectrometry (UHRMS) routinely detects and identifies thousands of mass peaks in complex mixtures, such as natural organic matter (NOM) and petroleum. The assignment of several chemically plausible molecular formulas (MFs) for a single accurate mass still poses a major problem for the reliable interpretation of NOM composition in a biogeochemical context. Applying sensible chemical rules for MF validation is often insufficient to eliminate multiple assignments (MultiAs)─especially for mass peaks with low abundance or if ample heteroatoms or isotopes are included - and requires manual inspection or expert judgment. Here, we present a new approach based on mass error distributions for the identification of true and false assignments among MultiAs. To this end, we used the mass error in millidalton (mDa), which was superior to the commonly used relative mass error in ppm. We developed an automatic workflow to group MultiAs based on their shared formula units and Kendrick mass defect values and to evaluate the mass error distribution. In this way, the number of valid assignments of chlorinated disinfection byproducts was increased by 8-fold as compared to only applying 37Cl/35Cl isotope ratio filters. Likewise, phosphorus-containing MFs can be differentiated against chlorine-containing MFs with high confidence. Further, false assignments of highly aromatic sulfur-containing MFs ("black sulfur") to sodium adducts in negative ionization mode can be excluded by applying our approach. Overall, MFs for mass peaks that are close to the detection limit or where naturally occurring isotopes are rare (e.g., 15N) or absent (e.g., P and F) can now be validated, substantially increasing the reliability of MF assignments and broadening the applicability of UHRMS analysis to even more complex samples and processes.
- 13 June 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (25) , 10210-10218
Open AccessDetection and Exclusion of False-Positive Molecular Formula Assignments via Mass Error Distributions in UHR Mass Spectra of Natural Organic Matter
Ultrahigh resolution mass spectrometry (UHRMS) routinely detects and identifies thousands of mass peaks in complex mixtures, such as natural organic matter (NOM) and petroleum. The assignment of several chemically plausible molecular formulas (MFs) for a single accurate mass still poses a major problem for the reliable interpretation of NOM composition in a biogeochemical context. Applying sensible chemical rules for MF validation is often insufficient to eliminate multiple assignments (MultiAs)─especially for mass peaks with low abundance or if ample heteroatoms or isotopes are included - and requires manual inspection or expert judgment. Here, we present a new approach based on mass error distributions for the identification of true and false assignments among MultiAs. To this end, we used the mass error in millidalton (mDa), which was superior to the commonly used relative mass error in ppm. We developed an automatic workflow to group MultiAs based on their shared formula units and Kendrick mass defect values and to evaluate the mass error distribution. In this way, the number of valid assignments of chlorinated disinfection byproducts was increased by 8-fold as compared to only applying 37Cl/35Cl isotope ratio filters. Likewise, phosphorus-containing MFs can be differentiated against chlorine-containing MFs with high confidence. Further, false assignments of highly aromatic sulfur-containing MFs ("black sulfur") to sodium adducts in negative ionization mode can be excluded by applying our approach. Overall, MFs for mass peaks that are close to the detection limit or where naturally occurring isotopes are rare (e.g., 15N) or absent (e.g., P and F) can now be validated, substantially increasing the reliability of MF assignments and broadening the applicability of UHRMS analysis to even more complex samples and processes.
- Top Cited PapersOpen Access
- 1 March 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 58 (10) , 4637-4647
Direct Analysis of Marine Dissolved Organic Matter Using LC-FT-ICR MS
Marine dissolved organic matter (DOM) is an important component of the global carbon cycle, yet its intricate composition and the sea salt matrix pose major challenges for chemical analysis. We introduce a direct injection, reversed-phase liquid chromatography ultrahigh resolution mass spectrometry approach to analyze marine DOM without the need for solid-phase extraction. Effective separation of salt and DOM is achieved with a large chromatographic column and an extended isocratic aqueous step. Postcolumn dilution of the sample flow with buffer-free solvents and implementing a counter gradient reduced salt buildup in the ion source and resulted in excellent repeatability. With this method, over 5,500 unique molecular formulas were detected from just 5.5 nmol carbon in 100 μL of filtered Arctic Ocean seawater. We observed a highly linear detector response for variable sample carbon concentrations and a high robustness against the salt matrix. Compared to solid-phase extracted DOM, our direct injection method demonstrated superior sensitivity for heteroatom-containing DOM. The direct analysis of seawater offers fast and simple sample preparation and avoids fractionation introduced by extraction. The method facilitates studies in environments, where only minimal sample volume is available e.g. in marine sediment pore water, ice cores, or permafrost soil solution. The small volume requirement also supports higher spatial (e.g., in soils) or temporal sample resolution (e.g., in culture experiments). Chromatographic separation adds further chemical information to molecular formulas, enhancing our understanding of marine biogeochemistry, chemodiversity, and ecological processes.
- 1 March 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 58 (10) , 4637-4647
Top Cited PapersOpen AccessDirect Analysis of Marine Dissolved Organic Matter Using LC-FT-ICR MS
Marine dissolved organic matter (DOM) is an important component of the global carbon cycle, yet its intricate composition and the sea salt matrix pose major challenges for chemical analysis. We introduce a direct injection, reversed-phase liquid chromatography ultrahigh resolution mass spectrometry approach to analyze marine DOM without the need for solid-phase extraction. Effective separation of salt and DOM is achieved with a large chromatographic column and an extended isocratic aqueous step. Postcolumn dilution of the sample flow with buffer-free solvents and implementing a counter gradient reduced salt buildup in the ion source and resulted in excellent repeatability. With this method, over 5,500 unique molecular formulas were detected from just 5.5 nmol carbon in 100 μL of filtered Arctic Ocean seawater. We observed a highly linear detector response for variable sample carbon concentrations and a high robustness against the salt matrix. Compared to solid-phase extracted DOM, our direct injection method demonstrated superior sensitivity for heteroatom-containing DOM. The direct analysis of seawater offers fast and simple sample preparation and avoids fractionation introduced by extraction. The method facilitates studies in environments, where only minimal sample volume is available e.g. in marine sediment pore water, ice cores, or permafrost soil solution. The small volume requirement also supports higher spatial (e.g., in soils) or temporal sample resolution (e.g., in culture experiments). Chromatographic separation adds further chemical information to molecular formulas, enhancing our understanding of marine biogeochemistry, chemodiversity, and ecological processes.
- Open Access
- 15 May 2023
- Published by Copernicus GmbH
Towards semi-quantification of DOM: isomer separation with LC-FT-ICR-MS combined with a post-column infusion of standard.
Ultrahigh-resolution mass spectrometry like FT-ICR MS has greatly expanded our view of the complexity and reactivity of complex dissolved organic matter (DOM) in the environment. However, both the structural characterization and (semi)-quantification DOM are methodologically not fully resolved, despite recent advances with coupling liquid chromatography (LC) to FT-ICR-MS that allows isomeric separation. Likewise, matrix effects and the existence of multiple isomers with largely varying – but unknown – ionization efficiencies that are simultaneously ionized and detected in direct infusion (DI)-FT-ICR MS prevents (semi)-quantification of DOM compounds and has limited the comparability of samples. Finally, common normalization strategies applied for non-targeted DOM analysis with DI cannot be easily transferred to LC-type DOM data. Here we present a new method that combines a post-column infusion of internal standard (PCI-IS) with LC-FT-ICR MS in order to reduce and compensate matrix effects as well as to provide a robust and reliable way to normalize MS peak intensities and compare samples measured with LC-FT-ICR MS. To this end, DOM samples were analyzed and the peak intensity data normalized by the internal standard and other frequently used normalization methods (e.g. sum of intensity, base peak), and absolute intensity indicating that PCI-IS normalization provides superior precision and accuracy. The potential of this method to provide semi-quantitative information on polarity fractions of DOM is assessed by testing the precision, accuracy, and linearity of PCI-IS normalization of model compounds spiked into DOM samples. Our results indicate that the use of LC separation reduced matrix effects (as compared to DI) and, in combination with the internal standard, improved to potential to obtain reliable peak intensity information.
- 15 May 2023
- Published by Copernicus GmbH
Open AccessTowards semi-quantification of DOM: isomer separation with LC-FT-ICR-MS combined with a post-column infusion of standard.
Ultrahigh-resolution mass spectrometry like FT-ICR MS has greatly expanded our view of the complexity and reactivity of complex dissolved organic matter (DOM) in the environment. However, both the structural characterization and (semi)-quantification DOM are methodologically not fully resolved, despite recent advances with coupling liquid chromatography (LC) to FT-ICR-MS that allows isomeric separation. Likewise, matrix effects and the existence of multiple isomers with largely varying – but unknown – ionization efficiencies that are simultaneously ionized and detected in direct infusion (DI)-FT-ICR MS prevents (semi)-quantification of DOM compounds and has limited the comparability of samples. Finally, common normalization strategies applied for non-targeted DOM analysis with DI cannot be easily transferred to LC-type DOM data. Here we present a new method that combines a post-column infusion of internal standard (PCI-IS) with LC-FT-ICR MS in order to reduce and compensate matrix effects as well as to provide a robust and reliable way to normalize MS peak intensities and compare samples measured with LC-FT-ICR MS. To this end, DOM samples were analyzed and the peak intensity data normalized by the internal standard and other frequently used normalization methods (e.g. sum of intensity, base peak), and absolute intensity indicating that PCI-IS normalization provides superior precision and accuracy. The potential of this method to provide semi-quantitative information on polarity fractions of DOM is assessed by testing the precision, accuracy, and linearity of PCI-IS normalization of model compounds spiked into DOM samples. Our results indicate that the use of LC separation reduced matrix effects (as compared to DI) and, in combination with the internal standard, improved to potential to obtain reliable peak intensity information.
- Open Access
- 8 December 2022
- Published by Elsevier in Water Research
- Vol. 229, 119477
Stable isotope labeling for detection of ozonation byproducts in effluent organic matter with FT-ICR-MS
- 8 December 2022
- Published by Elsevier in Water Research
- Vol. 229, 119477
Open AccessStable isotope labeling for detection of ozonation byproducts in effluent organic matter with FT-ICR-MS
- Open Access
- 10 January 2022
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 56 (3) , 1894-1904
Discovery of Polar Ozonation Byproducts via Direct Injection of Effluent Organic Matter with Online LC-FT-ICR-MS
Effluent organic matter (EfOM), a major ozone consumer during wastewater ozonation, is a complex mixture of natural and anthropogenic organic molecules. Ozonation of EfOM adds to molecular complexity by introducing polar and potentially mobile ozonation byproducts (OBPs). Currently, nontargeted direct infusion (DI) ultrahigh resolution mass spectrometry (e.g. FT-ICR-MS) is used to study OBPs but requires sample extraction, limiting the accessible polarity range of OBPs. To better understand the impact of ozonation on EfOM and the formation of polar OBPs, nonextracted effluent was analyzed by direct injection onto a reversed-phase liquid chromatography system (RP-LC) online hyphenated with an FT-ICR-MS. Over four times more OBPs were detected in nonextracted EfOM compared to effluent extracted with solid phase extraction and measured with DI-FT-ICR-MS (13817 vs 3075). Over 1500 highly oxygenated OBPs were detected exclusively in early eluting fractions of nonextracted EfOM, indicating polar OBPs. Oxygenation of these newly discovered OBPs is higher than previously found, with an average molecular DBE-O value of −3.3 and O/C ratio of 0.84 in the earliest eluting OBP fractions. These polar OBPs are consistently lost during extraction but may play an important role in understanding the environmental impact of ozonated EfOM. Moreover, 316 molecular formulas classified as nonreactive to ozone in DI-FT-ICR-MS can be identified with LC-FT-ICR-MS as isomers with varying degrees of reactivity, providing for the first time experimental evidence of differential reactivity of complex organic matter isomers with ozone.
- 10 January 2022
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 56 (3) , 1894-1904
Open AccessDiscovery of Polar Ozonation Byproducts via Direct Injection of Effluent Organic Matter with Online LC-FT-ICR-MS
Effluent organic matter (EfOM), a major ozone consumer during wastewater ozonation, is a complex mixture of natural and anthropogenic organic molecules. Ozonation of EfOM adds to molecular complexity by introducing polar and potentially mobile ozonation byproducts (OBPs). Currently, nontargeted direct infusion (DI) ultrahigh resolution mass spectrometry (e.g. FT-ICR-MS) is used to study OBPs but requires sample extraction, limiting the accessible polarity range of OBPs. To better understand the impact of ozonation on EfOM and the formation of polar OBPs, nonextracted effluent was analyzed by direct injection onto a reversed-phase liquid chromatography system (RP-LC) online hyphenated with an FT-ICR-MS. Over four times more OBPs were detected in nonextracted EfOM compared to effluent extracted with solid phase extraction and measured with DI-FT-ICR-MS (13817 vs 3075). Over 1500 highly oxygenated OBPs were detected exclusively in early eluting fractions of nonextracted EfOM, indicating polar OBPs. Oxygenation of these newly discovered OBPs is higher than previously found, with an average molecular DBE-O value of −3.3 and O/C ratio of 0.84 in the earliest eluting OBP fractions. These polar OBPs are consistently lost during extraction but may play an important role in understanding the environmental impact of ozonated EfOM. Moreover, 316 molecular formulas classified as nonreactive to ozone in DI-FT-ICR-MS can be identified with LC-FT-ICR-MS as isomers with varying degrees of reactivity, providing for the first time experimental evidence of differential reactivity of complex organic matter isomers with ozone.