Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Calogero Picone has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A New Device for Flow Rate Measurement and Energy Harvesting

    by Marco Sinagra, Calogero Picone, Giuseppe Lo Cicero, Tullio Tucciarelli

    This study summarizes the design, development, and experimental validation of a new self-powered, multiparametric sensor and valve. The device integrates a miniaturized Cross-Flow-type turbine with a built-in electrical generator, enabling energy harvesting directly from the pressurized water flow. The prototype of the new device was tested under controlled hydraulic conditions, with flow rates ranging from 0 to 3.1 L/s. Results demonstrated a production capability of up to 100 W of electrical power, with a nominal output of approximately 50 W at 2 L/s. Volume measurement error, assessed according to the MID European Directive, confirmed accuracy within acceptable thresholds.

  • Open Access

    A self-powered multiparametric sensor and valve for water distribution networks

    by Marco Sinagra, Calogero Picone, Giuseppe Lo Cicero, Daniele Puleo, Tullio Tucciarelli


  • Open Access

    Criticality Assessment of Pipes in Water Distribution Networks Based on the Minimum Pressure Criterion

    by Daniele Puleo, Marco Sinagra, Calogero Picone, Tullio Tucciarelli

    A new criticality indicator for Water Distribution Networks (WDNs) is presented. The new indicator is based on the minimum pressure (MP) model, which relies on the assumption that air can enter the pipes, e.g., when failure occurs in water scarcity scenarios, and maintain a minimum pressure equal to zero in the whole network. The proposed indicator properly integrates topological features, provided by structural hole theory, with the hydraulic constraints provided by the WDN steady-state solution, with a particular focus on pipes where occurring free surface flow leads to a serious reduction in the quality of the network service. The new indicator leads to a new criterion for the prioritized maintenance of pipes in existing networks, as well as for the design and planning of new ones, which is different from the one derived from other popular indicators. Three real-life WDNs are selected as test cases.


  • Open Access

    Criticality Assessment of Pipes in Water Distribution Networks Based on the Minimum Pressure Criterion

    by Daniele Puleo, Marco Sinagra, Calogero Picone, Tullio Tucciarelli

    A new criticality indicator for water distribution networks (WDNs) is presented. The new indicator is based on the minimum pressure (MP) model, which relies on the assumption that air can enter in the pipes, e.g. when failure occurs in water scarcity scenarios, and maintain equal to zero the minimum pressure in the whole network. The proposed indicator properly integrates topological features, provided by structural hole theory, with the hydraulic constraints provided by the WDN steady-state solution, with a particular focus on pipes where occurring free surface flow leads to a serious reduction of the quality of the network service. The new indicator leads to a new criterion for the prioritized mainte-nance of pipes in existing networks, as well as for the design and planning of new ones, which is different from the one derived from other popular indicators. Three real-life WDNs are selected as test cases.


  • Open Access

    A new regulation system for Crossflow type turbines for water management industry

    by Calogero Picone, Marco Sinagra, Tullio Tucciarelli


  • Open Access

    Performance Investigation of a Twisted Savonius Wind Rotor

    by Mariem Lajnef, Mabrouk Mosbahi, Mouna Derbel, Zied Driss, Antonio Pantano, Tullio Tucciarelli, Marco Sinagra, Calogero Picone

    For human welfare, electrical power is necessary. For many years, there has been a great deal of interest in wind energy because it is a clean, sustainable energy source. Because of its cheaper cost and independence from wind direction, the Savonius vertical axis wind rotor has the advantage of being suitable for certain implementations as an energy converter. Several studies have been carried out to increase its efficiency. In this paper, a novel blade design of a twisted Savonius wind rotor has been investigated numerically with the intention of performance betterment. Three-dimensional unsteady simulations were performed deploying Ansys Fluent using the Shear Stress Transport k-ω turbulence model based on the finite volume method solver. The wind flow aerodynamic characteristics in addition to the rotor performance properties were acquired and analyzed. The numerical model was validated based on findings taken from experimental tests performed on a 3-D printed twisted rotor in a wind tunnel. An improvement in the power coefficient by 22.58 % was recorded with the novel blade design over the twisted Savonius wind rotor. The obtained findings could provide further direction for researchers to use the twisted Savonius wind turbine in power generation.


  • Open Access

    Numerical Model Parameters Impact on Savonius Wind Rotor Performance

    by Mariem Lajnef, Mabrouk Mosbahi, Zied Driss, Emanuele Amato, Tullio Tucciarelli, Marco Sinagra, Calogero Picone

    Global greenhouse gas emissions are mostly caused by the production of energy extracted from fossil fuels sources. Indeed, the use of renewable clean energy has become crucial to supply the world demand while protecting the planet. For many years, there has been a great deal of interest in wind energy because it is a clean, sustainable energy source. Because of its cheaper cost and independence from wind direction, the Savonius vertical axis wind rotor has the advantage of being suitable for certain implementations as an energy converter. Several studies have been carried out to increase its efficiency from this angle. This research work emphasizes on the Savonius wind rotor numerical model performances. The main goal is to explore the impact of setting the numerical model parameters on its aerodynamic and performance characteristics. Ansys Fluent software 17.0 was utilized to perform numerical simulations utilizing the unsteady Reynolds-Averaged Navier-Stokes (URANS) equations. The mesh sizing, the turbulence model as well as the time step parameters were investigated. The numerical model validation was realized through published experimental findings available in the literature for an inlet wind velocity of 6 ms-1. Good accordance was obtained. Thus the numerical model with the selected parameters was relevant for further investigations. For a tip speed ratio λ=0.64 it gave a torque and power coefficients equal to 0.328 and 0.2, respectively.


  • Open Access

    Effect of the Turbulence Model on the Computational Results of a Lucid Spherical Rotor

    by Mabrouk Mosbahi, Mariem Lajnef, Mouna Derbel, Zied Driss, Emanuele Amato, Calogero Picone, Marco Sinagra, Tullio Tucciarelli

    Due to the excessive increase in the energy demand, renewable energy has become an alternative for electricity production for industrial and domestic needs. Water energy has received significant investment as a sustainable and clean energy source. Lucid spherical rotors, a kind of hydro-power converter, are cross flow rotors designed to be mounted within a pipeline in order to gather excess energy available in gravity-fed water pipelines. This paper focuses on the effect of the numerical model parameters choice, namely the turbulence model, on the Lucid spherical rotor hydrodynamic characteristics. Numerical simulations were carried out through Ansys Fluent software 17.0 using the unsteady Reynolds-Averaged Navier-Stokes (URANS) equations. Four turbulence models: RNG k-ε, Realizable k-ε, SST k-ω and transition SST were tested. Performance characteristics in terms of torque and power coefficients in addition to hydrodynamic features of the flow around the considered rotor were analyzed. The adopted numerical model was validated based on previous experimental findings from the literature. It was found that the realizable k-ε model showed a good agreement with experimental results. Thus, it was adopted for the Lucid spherical rotor simulation. The obtained findings could provide further direction for researchers to use the Lucid spherical water turbine.


  • Open Access

    A New Cross-Flow Type Turbine for Ultra-Low Head in Streams and Channels

    by Calogero Picone, Marco Sinagra, Luana Gurnari, Tullio Tucciarelli, Pasquale G. F. Filianoti

    In the last few decades, hydropower production has been moving toward a new paradigm of low and diffused power density production of energy with small and mini-hydro plants, which usually do not require significant water storage. In the case of nominal power lower than 20 kW and ultra-low head H (H < 5 m), Archimedes screw or Kaplan type turbines are usually chosen due to their efficiency, which is higher than 0.85. A new cross-flow type turbine called Ultra-low Power Recovery System (UL-PRS) is proposed and its geometry and design criteria are validated in a wide range of operating conditions through 2D numerical analysis computed using the ANSYS Fluent solver. The new proposed solution is much simpler than the previously mentioned competitors; its outlet flow has a horizontal direction and attains similar efficiency. The costs of the UL-PRS turbine are compared with the costs of one Kaplan and one cross-flow turbine (CFT) in the case study of the main water treatment plant of the city of Palermo in Italy. In this case, the UL-PRS efficiency is estimated using a URANS 3D numerical analysis computed with the CFX solver.


  • Open Access

    Low-Head Hydropower for Energy Recovery in Wastewater Systems

    by Marco Sinagra, Calogero Picone, Paolo Picone, Costanza Aricò, Tullio Tucciarelli, Helena M. Ramos

    Hydraulic turbines for energy recovery in wastewater treatment plants, with relatively large discharges values and small head jumps, are usually screw Archimedes or Kaplan types. In the specific case of a small head jump (about 3 m) underlying a rectangular weir in the major Palermo (Italy) water treatment plant, a traditional Kaplan solution is compared with two other new proposals: a Hydrostatic Pressure Machine (HPM) located at the upstream channel and a cross-flow turbine (CFT) located in a specific underground room downstream of the same channel. The fluid mechanical formulations of the flow through these turbines are analyzed and the characteristic parameters are stated. Numerical analysis was carried out for the validation of the HPM design criteria. The efficiency at the design point of the CFT and HPM are estimated using the ANSYS CFX solver for resolution of 3D URANS analysis. The strong and weak points of the three devices are compared. Finally, a viability analysis is developed based on several economic indicators. This innovative study with a theoretical formulation of the most suitable turbomachine characterization, the potential energy estimation based on hydraulic energy recovery in a real case study of a wastewater treatment plant and the comparison of the three different low-head turbines, enhancing the main advantages, is of utmost importance towards the net-zero water sector decarbonization.