  • Robotic Systems in Ophthalmologic Surgery

    by Marina Roizenblatt, Ali Ebrahini, Iulian Iordachita, Peter Louis Gehlbach

  • Simultaneous Online Registration-Independent Stiffness Identification and Tip Localization of Surgical Instruments in Robot-Assisted Eye Surgery

    by Ali Ebrahimi, Shahriar Sefati, Peter Gehlbach, Russell H. Taylor, Iulian I. Iordachita

    Notable challenges during retinal surgery lend themselves to robotic assistance, which has proven beneficial in providing safe steady-hand manipulation. Efficient assistance from the robots heavily relies on accurate sensing of surgery states (e.g., instrument tip localization and tool-to-tissue interaction forces). Many of the existing tool tip localization methods require preoperative frame registrations or instrument calibrations. In this study, using an iterative approach and by combining vision and force-based methods, we develop calibration- and registration-independent (RI) algorithms to provide online estimates of instrument stiffness (least squares and adaptive). The estimations are then combined with a state-space model based on the forward kinematics of the steady-hand eye robot and fiber Bragg grating sensor measurements. This is accomplished using a Kalman filtering approach to improve the deflected instrument tip position estimations during robot-assisted eye surgery. The conducted experiments demonstrate that when the online RI stiffness estimations are used, the instrument tip localization results surpass those obtained from preoperative offline calibrations for stiffness.


  • Force-Based Control for Safe Robot-Assisted Retinal Interventions: In Vivo Evaluation in Animal Studies

    by Niravkumar Patel, Muller Urias, Ali Ebrahimi, Russell H. Taylor, Peter Gehlbach, Iulian Iordachita

    In recent years, robotic assistance in vitreoretinal surgery has moved from a benchtop environment to the operating rooms. Emerging robotic systems improve tool manoeuvrability and provide precise tool motions in a constrained intraocular environment and reduce/remove hand tremor. However, often due to their stiff and bulky mechanical structure, they diminish the perception of tool-to-sclera (scleral) forces, on which the surgeon relies, for eyeball manipulation. In this paper we measure these scleral forces and actively control the robot to keep them under a predefined threshold. Scleral forces are measured using a Fiber Bragg Grating (FBG) based force sensing instrument in an in vivo rabbit eye model in manual, cooperative robotic assistance with no scleral force control (NC), adaptive scleral force norm control (ANC) and adaptive scleral force component control (ACC) methods. To the best of our knowledge, this is the first time that the scleral forces are measured in an in vivo eye model during robot assisted vitreoretinal procedures. An experienced retinal surgeon repeated an intraocular tool manipulation (ITM) task 10 times in four in vivo rabbit eyes and a phantom eyeball, for a total of 50 repetitions in each control mode. Statistical analysis shows that the ANC and ACC control schemes restrict the duration of the undesired scleral forces to 4.41% and 14.53% as compared to 43.30% and 35.28% in manual and NC cases, respectively during the in vivo studies. These results show that the active robot control schemes can maintain applied scleral forces below a desired threshold during robot-assisted vitreoretinal surgery. The scleral forces measurements in this study may enable a better understanding of tool-to-sclera interactions during vitreoretinal surgery and the proposed control strategies could be extended to other microsurgery and robot-assisted interventions.


  • Force and Velocity Based Puncture Detection in Robot Assisted Retinal Vein Cannulation: In-Vivo Study

    by Alireza Alamdar, Niravkumar Patel, Muller Urias, Ali Ebrahimi, Peter Gehlbach, Iulian Iordachita

    Objective: Retinal vein cannulation is a technically demanding surgical procedure and its feasibility may rely on using advanced surgical robots equipped with force-sensing microneedles. Reliable detection of the moment of venous puncture is important, to either alert or prevent the clinician from double puncturing the vessel and damaging the retinal surface beneath. This paper reports the first in-vivo retinal vein cannulation trial on rabbit eyes, using sensorized metal needles, and investigates puncture detection. Methods: We utilized total of four indices including two previously demonstrated ones and two new indices, based on the velocity and force of the needle tip and the correlation between the needle-tissue and tool-sclera interaction forces. We also studied the effect of detection timespan on the performance of detecting actual punctures. Results: The new indices, when used in conjunction with the previous algorithm, improved the detection rate form $75\%$ to $92\%$ , but slightly increased the number of false detections from 37 to 43. Increasing the detection window improved the detection performance, at the cost of adding to the delay. Conclusion: The current algorithm can supplement the surgeons’ visual feedback and surgical judgment. To achieve automatic puncture detection, more measurements and further analysis are required. Subsequent in-vivo studies in other animals, such as pigs with their more human like eye anatomy, are required, before clinical trials. Significance: The study provides promising results and the criteria developed may serve as guidelines for further investigation into puncture detection in in-vivo retinal vein cannulation.


  • Spotlight-Based 3D Instrument Guidance for Autonomous Task in Robot-Assisted Retinal Surgery

    by Mingchuan Zhou, Jiahao Wu, Ali Ebrahimi, Niravkumar Patel, Yunhui Liu, Nassir Navab, Peter Gehlbach, Alois Knoll, M. Ali Nasseri, Iulian Iordachita

    Retinal surgery is known to be a complicated and challenging task for an ophthalmologist even for retina specialists. Image guided robot-assisted intervention is among the novel and promising solutions that may enhance human capabilities during microsurgery. In this letter, a novel method is proposed for 3D navigation of a microsurgical instrument based on the projection of a spotlight during robot-assisted retinal surgery. To test the feasibility and effectiveness of the proposed method, a vessel tracking task in a phantom with a Remote Center of Motion (RCM) constraint is performed by the Steady-Hand Eye Robot (SHER). The results are compared to manual tracking, cooperative control tracking with the SHER and spotlight-based automatic tracking with SHER. The reported results are that the spotlight-based automatic tracking with SHER can reach an average tracking error of 0.013 mm and keeping distance error of 0.1 mm from the desired range demonstrating a significant improvement compared to manual or cooperative control methods alone.


  • Adaptive Control Improves Sclera Force Safety in Robot-Assisted Eye Surgery: A Clinical Study

    by Ali Ebrahimi, Muller G. Urias, Niravkumar Patel, Russell H. Taylor, Peter Gehlbach, Iulian Iordachita

    The integration of robotics into retinal microsurgery leads to a reduction in surgeon perception of tool-to-tissue interaction forces. This blunting of human tactile sensory input, which is due to the inflexible mass and large inertia of the robotic arm as compared to the milli-Newton scale of the interaction forces and fragile tissues during ophthalmic surgery, identifies a potential iatrogenic risk during robotic eye surgery. In this paper, we aim to evaluate two variants of an adaptive force control scheme implemented on the Steady-Hand Eye Robot (SHER) that are intended to mitigate the risk of unsafe scleral forces. The present study enrolled ten retina fellows and ophthalmology residents into a simulated procedure, which simply asked the trainees to follow retinal vessels in a model retina surgery environment. For this purpose, we have developed a force-sensing (equipped with Fiber Bragg Grating (FBG)) instrument to attach to the robot. A piezo-actuated linear stage for creating random lateral motions to the eyeball phantom has been provided to simulate disturbances during surgery. The SHER and all of its dependencies were set up in an operating room in the Wilmer Eye Institute at the Johns Hopkins Hospital. The clinicians conducted robot-assisted experiments with the adaptive controls incorporated as well as freehand manipulations. The results indicate that the Adaptive Norm Control (ANC) method, is able to maintain scleral forces at predetermined safe levels better than even freehand manipulations. Novice clinicians in robot training however, subjectively preferred freehand maneuvers over robotic manipulations. Clinician preferences once highly skilled with the robot is not assessed in this study.


  • FBG-based Kalman Filtering and Control of Tool Insertion Depth For Safe Robot-assisted Vitrectomy

    by Ali Ebrahimi, Muller Urias, Niravkumar Patel, Peter Gehlbach, Farshid Alambeigi, Iulian Iordachita

    Vitrectomy is that portion of retinal surgery in which the vitreous gel is removed either as a definitive treatment or to provide direct tool access to the retina. This procedure should be conducted prior to several eye surgeries in order to provide better access to the eyeball posterior. It is a relatively repeatable and straight forward procedure that lends itself to robotic assistance or potentially autonomous performance if tool contact with critical structures can be avoided. One of the detrimental incidences that can occur during the robot-assisted vitrectomy is when the robot penetrates the tool more than allowed boundaries into the eyeball toward retina. In this paper, we provide filtering and control to guide instrument insertion depth in order to avoid tool-to-retina contact. For this purpose, first the tool insertion depth measurement is improved using a Kalman filtering (KF) algorithm. This improved measurement is then used in an adaptive control strategy by which the robot reduces the tool insertion depth based on a predefined and safe trajectory for it, when safe boundaries are overstepped. The performance of the insertion depth safety control system is then compared to one in which the insertion depth is not passed through a Kalman filter prior to being fed to the control system. Our results indicate that applying KF in the adaptive control of the robot enhances procedure safety and enables the robot to always keep the tool insertion depth under the safe levels.


  • Auditory Feedback Effectiveness for Enabling Safe Sclera Force in Robot-Assisted Vitreoretinal Surgery: a Multi-User Study

    by Ali Ebrahimi, Marina Roizenblatt, Niravkumar Patel, Peter Gehlbach, Iulian Iordachita

    Robot-assisted retinal surgery has become increasingly prevalent in recent years in part due to the potential for robots to help surgeons improve the safety of an immensely delicate and difficult set of tasks. The integration of robots into retinal surgery has resulted in diminished surgeon perception of tool-to-tissue interaction forces due to robot's stiffness. The tactile perception of these interaction forces (sclera force) has long been a crucial source of feedback for surgeons who rely on them to guide surgical maneuvers and to prevent damaging forces from being applied to the eye. This problem is exacerbated when there are unfavorable sclera forces originating from patient movements (dynamic eyeball manipulation) during surgery which may cause the sclera forces to increase even drastically. In this study we aim at evaluating the efficacy of providing warning auditory feedback based on the level of sclera force measured by force sensing instruments. The intent is to enhance safety during dynamic eye manipulations in robot-assisted retinal surgery. The disturbances caused by lateral movement of patient's head are simulated using a piezo-actuated linear stage. The Johns Hopkins Steady-Hand Eye Robot (SHER), is then used in a multi-user experiment. Twelve participants are asked to perform a mock retinal surgery by following painted vessels inside an eye phantom using a force sensing instrument while auditory feedback is provided. The results indicate that the users are able to handle the eye motion disturbances while maintaining the sclera forces within safe boundaries when audio feedback is provided.


  • Stochastic Force-Based Insertion Depth and Tip Position Estimations of Flexible FBG-Equipped Instruments in Robotic Retinal Surgery

    by Ali Ebrahimi, Farshid Alambeigi, Shahriar Sefati, Niravkumar Patel, Changyan He, Peter Gehlbach, Iulian Iordachita

    Vitreoretinal surgery is among the most delicate surgical tasks during which surgeon hand tremor may severely attenuate surgeon performance. Robotic assistance has been demonstrated to be beneficial in diminishing hand tremor. Among the requirements for reliable assistance from the robot is to provide precise measurements of system states, e.g., sclera forces, tool tip position, and tool insertion depth. Providing this and other sensing information using existing technology would contribute toward development and implementation of autonomous robot-assisted tasks in retinal surgery such as laser ablation, guided suture placement/assisted needle vessel cannulation, among other applications. In this article, we use a state-estimating Kalman filtering (KF) to improve the tool tip position and insertion depth estimates, which used to be purely obtained by robot forward kinematics (FWK) and direct sensor measurements, respectively. To improve tool tip localization, in addition to robot FWK, we also use sclera force measurements along with beam theory to account for tool deflection. For insertion depth, the robot FWK is combined with sensor measurements for the cases where sensor measurements are not reliable enough. The improved tool tip position and insertion depth measurements are validated using a stereo camera system through preliminary experiments and a case study. The results indicate that the tool tip position and insertion depth measurements are significantly improved by 77% and 94% after applying KF, respectively.


  • Automatic Light Pipe Actuating System for Bimanual Robot-Assisted Retinal Surgery

    by Changyan He, Emily Yang, Niravkumar Patel, Ali Ebrahimi, Mahya Shahbazi, Peter Louis Gehlbach, Iulian Iordachita

    Retinal surgery is a bimanual operation in which surgeons operate with an instrument in their dominant hand (more capable hand) and simultaneously hold a light pipe (illuminating pipe) with their non-dominant hand (less capable hand) to provide illumination inside the eye. Manually holding and adjusting the light pipe places an additional burden on the surgeon and increases the overall complexity of the procedure. To overcome these challenges, a robot-assisted automatic light pipe actuating system is proposed. A customized light pipe with force-sensing capability is mounted at the end effector of a follower robot and is actuated through a hybrid force-velocity controller to automatically illuminate the target area on the retinal surface by pivoting about the scleral port (incision on the sclera). Static following-accuracy evaluation and dynamic light tracking experiments are carried out. The results show that the proposed system can successfully illuminate the desired area with negligible offset (the average offset is 2.45 mm with standard deviation of 1.33 mm). The average scleral forces are also below a specified threshold (50 mN). The proposed system not only can allow for increased focus on dominant hand instrument control, but also could be extended to three-arm procedures (two surgical instruments held by surgeon plus a robot-holding light pipe) in retinal surgery, potentially improving surgical efficiency and outcome.