Auditory Feedback Effectiveness for Enabling Safe Sclera Force in Robot-Assisted Vitreoretinal Surgery: a Multi-User Study
Authors:
- 24 October 2020
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2020, 3274-3280
Abstract
Robot-assisted retinal surgery has become increasingly prevalent in recent years in part due to the potential for robots to help surgeons improve the safety of an immensely delicate and difficult set of tasks. The integration of robots into retinal surgery has resulted in diminished surgeon perception of tool-to-tissue interaction forces due to robot's stiffness. The tactile perception of these interaction forces (sclera force) has long been a crucial source of feedback for surgeons who rely on them to guide surgical maneuvers and to prevent damaging forces from being applied to the eye. This problem is exacerbated when there are unfavorable sclera forces originating from patient movements (dynamic eyeball manipulation) during surgery which may cause the sclera forces to increase even drastically. In this study we aim at evaluating the efficacy of providing warning auditory feedback based on the level of sclera force measured by force sensing instruments. The intent is to enhance safety during dynamic eye manipulations in robot-assisted retinal surgery. The disturbances caused by lateral movement of patient's head are simulated using a piezo-actuated linear stage. The Johns Hopkins Steady-Hand Eye Robot (SHER), is then used in a multi-user experiment. Twelve participants are asked to perform a mock retinal surgery by following painted vessels inside an eye phantom using a force sensing instrument while auditory feedback is provided. The results indicate that the users are able to handle the eye motion disturbances while maintaining the sclera forces within safe boundaries when audio feedback is provided.Keywords
This publication has 29 references indexed in Scilit:
- Quantitative assessment of manual and robotic microcannulation for eye surgery using new eye modelThe International Journal of Medical Robotics and Computer Assisted Surgery, 2014
- The introduction of a new robot for assistance in ophthalmic surgery2013
- A comparative study for robot assisted vitreoretinal surgery: Micron vs. the Steady-Hand Robot2013
- Auditory Force Feedback Substitution Improves Surgical Precision during Simulated Ophthalmic SurgeryInvestigative Ophthalmology & Visual Science, 2013
- Comparison of robot-assisted and manual retinal vessel microcannulation in an animal modelBritish Journal of Ophthalmology, 2010
- Branch Retinal Vein Occlusion: Pathogenesis, Visual Prognosis, and Treatment ModalitiesCurrent Eye Research, 2008
- Development and Application of a New Steady-Hand Manipulator for Retinal Surgery2007
- Toward active tremor canceling in handheld microsurgical instrumentsIEEE Transactions on Robotics and Automation, 2003
- Physiological tremor amplitude during retinal microsurgery2002
- Injection of tissue plasminogen activator into a branch retinal vein in eyes with central retinal vein occlusionOphthalmology, 2001