Alois Schmid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alois Schmid has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Martin Rosentritt
Department of Prosthetic Dentistry, UKR University Hospital Regensburg, 93042 Regensburg, Germany
8 shared publications - Thomas Strasser
Department of Prosthetic Dentistry, UKR University Hospital Regensburg, 93042 Regensburg, Germany
6 shared publications - Christina Huber
Department of Prosthetic Dentistry, UKR University Hospital Regensburg, 93042 Regensburg, Germany
3 shared publications - Andreas Koenig
Department of Dental Prosthetics and Materials Science, Leipzig University, 04103 Leipzig, Germany
1 shared publication - Dieter Drescher
Department of Orthodontics, University Clinic of Düsseldorf, 40225 Düsseldorf, Germany
1 shared publication - Florian Beuer
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, Aßmannshauser Str. 4–6, 14197 Berlin, Germany
1 shared publication
Latest Publications
- 1 July 2023
- Published by Quintessence Publishing in The International Journal of Prosthodontics
- Vol. 36 (4) , 436-442
Finite Element Analysis of Occlusal Interferences in Dental Prosthetics Caused by Occlusal Adjustment
Alois Schmid/Thomas Strasser/Martin Rosentritt: Purpose: To investigate the influence of occlusal interference in dental prosthetics using finite element analysis (FEA). Materials and Methods: The FEA model designed for this study centered on an all-ceramic, bi-layered, fixed partial denture (FPD) retained on the maxillary first premolar and molar, with the second premolar replaced by a pontic. The surrounding structures, such as the neighboring teeth, antagonists, and periodontium, were modeled. Four different load cases were designed at occlusal interferences of 0, 8, 12, and 24 μm, loaded by a simulated bite force of 300 N. Principal and von Mise stresses, as well as strain, were evaluated for all included structures. Results: For interferences of 12 and 24 μm, failure-relevant tensile stresses in the veneering layer were observed at the occlusal surfaces. Stress found in the zirconia FPD did not reach fatigue or flexural strength for any test load. Conclusion: Peak tensile stress was observed in close proximity to occlusal contact points, increasing with increasing occlusal interference. The FEA results suggested that the majority of occlusal stress is absorbed by the deformation of the periodontal ligament. Framework failure caused by the simulated interferences was not expected. Surface defects may ultimately lead to failure due to fracture or chipping, especially in cases of weaker ceramics or veneering.
- 1 July 2023
- Published by Quintessence Publishing in The International Journal of Prosthodontics
- Vol. 36 (4) , 436-442
Finite Element Analysis of Occlusal Interferences in Dental Prosthetics Caused by Occlusal Adjustment
Alois Schmid/Thomas Strasser/Martin Rosentritt: Purpose: To investigate the influence of occlusal interference in dental prosthetics using finite element analysis (FEA). Materials and Methods: The FEA model designed for this study centered on an all-ceramic, bi-layered, fixed partial denture (FPD) retained on the maxillary first premolar and molar, with the second premolar replaced by a pontic. The surrounding structures, such as the neighboring teeth, antagonists, and periodontium, were modeled. Four different load cases were designed at occlusal interferences of 0, 8, 12, and 24 μm, loaded by a simulated bite force of 300 N. Principal and von Mise stresses, as well as strain, were evaluated for all included structures. Results: For interferences of 12 and 24 μm, failure-relevant tensile stresses in the veneering layer were observed at the occlusal surfaces. Stress found in the zirconia FPD did not reach fatigue or flexural strength for any test load. Conclusion: Peak tensile stress was observed in close proximity to occlusal contact points, increasing with increasing occlusal interference. The FEA results suggested that the majority of occlusal stress is absorbed by the deformation of the periodontal ligament. Framework failure caused by the simulated interferences was not expected. Surface defects may ultimately lead to failure due to fracture or chipping, especially in cases of weaker ceramics or veneering.
- Open Access
- 25 August 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (17) , 4982
Fracture Load and Fracture Patterns of Monolithic Three-Unit Anterior Fixed Dental Prostheses after In Vitro Artificial Aging—A Comparison between Color-Gradient and Strength-Gradient Multilayer Zirconia Materials with Varying Yttria Content
(1) Background: Due to advantages such as avoidance of chipping, pulp-friendly tooth preparation and cost reduction, zirconia is increasingly being used monolithically without veneering. Nevertheless, to enable good aesthetics, various multilayer systems have been developed. The aim of this study was to investigate the impact of different zirconia multilayer strategies and yttria levels on fracture load, fracture pattern, stress distribution and surface roughness. (2) Methods: Monolithic three-unit anterior FDPs were made from three different color-gradient zirconia multilayer materials with different yttria levels corresponding to varying strength and degrees of translucency grades (Katana HTML, STML, UTML, Kuraray) and one strength-gradient zirconia multilayer material (Katana YML, Kuraray) and artificially aged in a chewing simulator (1.2 × 106 load cycles, 50 N, 2 × 3000 thermocycles, 5–55 °C). Analyses of fracture load, fracture pattern, fracture surfaces, stress distribution and roughness were performed after the fracture load test. Shapiro–Wilk, Kruskal–Wallis, Mann–Whitney U-tests and one-way ANOVA were used (p < 0.05). (3) Results: Fracture loads of the high strength color-gradient material HTML and the strength-gradient material YML were comparable after 5 years of aging (p = 0.645). Increasing yttria levels resulted in a decrease in fracture resistance of 42–57% (p < 0.05). Surface roughness of different zirconia generations is comparable after polishing and aging. (4) Conclusions: Color-gradient multilayer zirconia materials and new strength-gradient zirconia materials with similar yttria levels in the basal layers show comparable mechanical properties and are suitable for anterior FDPs.
- 25 August 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (17) , 4982
Open AccessFracture Load and Fracture Patterns of Monolithic Three-Unit Anterior Fixed Dental Prostheses after In Vitro Artificial Aging—A Comparison between Color-Gradient and Strength-Gradient Multilayer Zirconia Materials with Varying Yttria Content
(1) Background: Due to advantages such as avoidance of chipping, pulp-friendly tooth preparation and cost reduction, zirconia is increasingly being used monolithically without veneering. Nevertheless, to enable good aesthetics, various multilayer systems have been developed. The aim of this study was to investigate the impact of different zirconia multilayer strategies and yttria levels on fracture load, fracture pattern, stress distribution and surface roughness. (2) Methods: Monolithic three-unit anterior FDPs were made from three different color-gradient zirconia multilayer materials with different yttria levels corresponding to varying strength and degrees of translucency grades (Katana HTML, STML, UTML, Kuraray) and one strength-gradient zirconia multilayer material (Katana YML, Kuraray) and artificially aged in a chewing simulator (1.2 × 106 load cycles, 50 N, 2 × 3000 thermocycles, 5–55 °C). Analyses of fracture load, fracture pattern, fracture surfaces, stress distribution and roughness were performed after the fracture load test. Shapiro–Wilk, Kruskal–Wallis, Mann–Whitney U-tests and one-way ANOVA were used (p < 0.05). (3) Results: Fracture loads of the high strength color-gradient material HTML and the strength-gradient material YML were comparable after 5 years of aging (p = 0.645). Increasing yttria levels resulted in a decrease in fracture resistance of 42–57% (p < 0.05). Surface roughness of different zirconia generations is comparable after polishing and aging. (4) Conclusions: Color-gradient multilayer zirconia materials and new strength-gradient zirconia materials with similar yttria levels in the basal layers show comparable mechanical properties and are suitable for anterior FDPs.
- Open Access
- 30 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (15) , 7698
Martens Hardness of CAD/CAM Resin-Based Composites
(1) Background: The properties of CAD/CAM resin-based composites differ due to differences in their composition. Instrumented indentation testing can help to analyze these differences with respect to hardness, as well as energy-converting capabilities due to viscoelastic behavior. (2) Methods: Eleven materials were investigated using instrumented indentation testing. Indentation depth (hr), Martens hardness (HM), indentation hardness (HIT), indentation modulus (EIT), the elastic part of indentation work (ηIT), and indentation creep (CIT) were investigated, and statistical analysis was performed using one-way ANOVA, Bonferroni post-hoc test, and Pearson correlation (α = 0.05). (3) Results: All of the investigated parameters revealed differences between the analyzed materials. Besides the differences in hardness-associated parameters (hr, HM, and HIT), instrumented indentation testing demonstrated differences in energy-converting properties. The subsequent one-way ANOVA revealed significant differences (p < 0.001). A significant (p < 0.01, Pearson correlation >0.576) correlation between the materials and HM, HIT, or EIT was identified. (4) Conclusions: Due to the differences found in the energy-converting properties of the investigated materials, certain CAD/CAM resin-based composites could show superior stress-breaking capabilities than others. The consequential reduction in stress build-up may prove to beneficial, especially for implant-retained restorations or patients suffering from parafunctions.
- 30 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (15) , 7698
Open AccessMartens Hardness of CAD/CAM Resin-Based Composites
(1) Background: The properties of CAD/CAM resin-based composites differ due to differences in their composition. Instrumented indentation testing can help to analyze these differences with respect to hardness, as well as energy-converting capabilities due to viscoelastic behavior. (2) Methods: Eleven materials were investigated using instrumented indentation testing. Indentation depth (hr), Martens hardness (HM), indentation hardness (HIT), indentation modulus (EIT), the elastic part of indentation work (ηIT), and indentation creep (CIT) were investigated, and statistical analysis was performed using one-way ANOVA, Bonferroni post-hoc test, and Pearson correlation (α = 0.05). (3) Results: All of the investigated parameters revealed differences between the analyzed materials. Besides the differences in hardness-associated parameters (hr, HM, and HIT), instrumented indentation testing demonstrated differences in energy-converting properties. The subsequent one-way ANOVA revealed significant differences (p < 0.001). A significant (p < 0.01, Pearson correlation >0.576) correlation between the materials and HM, HIT, or EIT was identified. (4) Conclusions: Due to the differences found in the energy-converting properties of the investigated materials, certain CAD/CAM resin-based composites could show superior stress-breaking capabilities than others. The consequential reduction in stress build-up may prove to beneficial, especially for implant-retained restorations or patients suffering from parafunctions.
- Open Access
4-Unit Molar Fixed Partial Dentures Made from Highly Translucent and Multilayer Zirconia Materials: An In Vitro Investigation
Background: Modern zirconia blanks for the fabrication of dental CAD/CAM restorations provide a layer structure with color and strength transitions. Variation in the yttria content has a particular effect on the characteristics of the materials. The properties of dental restorations may vary depending on the milling position within the blank. Especially for wide-span fixed partial dentures (FPDs), relevant effects on clinical performance might result. This study investigated if the application of high-translucent zirconia and positioning within multilayer zirconia blanks affect the in vitro performance of 4-unit FPDs. Methods: 4-unit FPDs were fabricated from monolayer 3Y-TZP-A, 3Y-TZP, 4Y-TZP, 5Y-TZP, 4Y/5Y-TZP, and different positions within multilayer zirconia blanks (3Y-TZP/5Y-TZP). The FPDs were adhesively luted to resin abutment teeth, divided into groups (n = 8 each): “baseline” (24 h water-storage)/“TCML” (chewing simulation by means of thermalcycling and mechanical loading), and loaded to fracture. The statistics included mean and standard deviation, one-way ANOVA, Bonferroni post hoc test, and Pearson correlation (α = 0.05). Results: The mean fracture force values varied between 803.8 ± 171.7 N (5Y) and 1474.1 ± 193.0 N (3Y) (baseline) and 713.5 ± 190.9 N (5Y) and 1337.4 ± 205.6 N (3Y) (TCML). Significantly different (p = 0.000) results between the groups and individual significant differences (p ≤ 0.039) were found. Conclusions: Positioning within multilayer blanks affected the fracture force only slightly. Multilayer, 3Y-TZP-A, 3Y-TZP, and 4Y-TZP seem appropriate for the clinical application with 4-unit molar FPDs. Application of 5Y-TZP is critical.
Open Access4-Unit Molar Fixed Partial Dentures Made from Highly Translucent and Multilayer Zirconia Materials: An In Vitro Investigation
Background: Modern zirconia blanks for the fabrication of dental CAD/CAM restorations provide a layer structure with color and strength transitions. Variation in the yttria content has a particular effect on the characteristics of the materials. The properties of dental restorations may vary depending on the milling position within the blank. Especially for wide-span fixed partial dentures (FPDs), relevant effects on clinical performance might result. This study investigated if the application of high-translucent zirconia and positioning within multilayer zirconia blanks affect the in vitro performance of 4-unit FPDs. Methods: 4-unit FPDs were fabricated from monolayer 3Y-TZP-A, 3Y-TZP, 4Y-TZP, 5Y-TZP, 4Y/5Y-TZP, and different positions within multilayer zirconia blanks (3Y-TZP/5Y-TZP). The FPDs were adhesively luted to resin abutment teeth, divided into groups (n = 8 each): “baseline” (24 h water-storage)/“TCML” (chewing simulation by means of thermalcycling and mechanical loading), and loaded to fracture. The statistics included mean and standard deviation, one-way ANOVA, Bonferroni post hoc test, and Pearson correlation (α = 0.05). Results: The mean fracture force values varied between 803.8 ± 171.7 N (5Y) and 1474.1 ± 193.0 N (3Y) (baseline) and 713.5 ± 190.9 N (5Y) and 1337.4 ± 205.6 N (3Y) (TCML). Significantly different (p = 0.000) results between the groups and individual significant differences (p ≤ 0.039) were found. Conclusions: Positioning within multilayer blanks affected the fracture force only slightly. Multilayer, 3Y-TZP-A, 3Y-TZP, and 4Y-TZP seem appropriate for the clinical application with 4-unit molar FPDs. Application of 5Y-TZP is critical.
- 1 January 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 127 (1) , 141-145
Multilayer zirconia: Influence of positioning within blank and sintering conditions on the in vitro performance of 3-unit fixed partial dentures
- 1 January 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 127 (1) , 141-145
Multilayer zirconia: Influence of positioning within blank and sintering conditions on the in vitro performance of 3-unit fixed partial dentures
- 1 December 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 124, 104885
Dynamic fatigue of 3D-printed splint materials
- 1 December 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 124, 104885
Dynamic fatigue of 3D-printed splint materials
- Open Access
- 26 November 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (12) , 1779
Thermoanalytical Investigations on the Influence of Storage Time in Water of Resin-Based CAD/CAM Materials
New resin-based composites and resin-infiltrated ceramics are used to fabricate computer-aided design (CAD) and computer-aided manufacturing (CAM)-based restorations, although little information is available on the long-term performance of these materials. The aim of this investigation was to determine the effects of storage time (24 h, 90 days, 180 days) on the thermophysical properties of resin-based CAD/CAM materials. Thermogravimetric Analysis (TGA), differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA) were used in the study. TGA provided insight into the composition of the resin-based materials and the influence of internal plasticization and water sorption. Resin-based composites showed different decomposition, heat energy and mechanical behavior, which was influenced by storage time in water. Individual materials such as Grandio bloc showed lower influence of water storage while maintaining good mechanical properties.
- 26 November 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (12) , 1779
Open AccessThermoanalytical Investigations on the Influence of Storage Time in Water of Resin-Based CAD/CAM Materials
New resin-based composites and resin-infiltrated ceramics are used to fabricate computer-aided design (CAD) and computer-aided manufacturing (CAM)-based restorations, although little information is available on the long-term performance of these materials. The aim of this investigation was to determine the effects of storage time (24 h, 90 days, 180 days) on the thermophysical properties of resin-based CAD/CAM materials. Thermogravimetric Analysis (TGA), differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA) were used in the study. TGA provided insight into the composition of the resin-based materials and the influence of internal plasticization and water sorption. Resin-based composites showed different decomposition, heat energy and mechanical behavior, which was influenced by storage time in water. Individual materials such as Grandio bloc showed lower influence of water storage while maintaining good mechanical properties.
- 1 October 2021
- Published by Elsevier in Dental Materials
- Vol. 37 (10) , 1584-1591
Investigating the mechanical and optical properties of novel Urethandimethacrylate (UDMA) and Urethanmethacrylate (UMA) based rapid prototyping materials
- 1 October 2021
- Published by Elsevier in Dental Materials
- Vol. 37 (10) , 1584-1591
Investigating the mechanical and optical properties of novel Urethandimethacrylate (UDMA) and Urethanmethacrylate (UMA) based rapid prototyping materials
- 1 September 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 121, 104612
Pilot in-vitro study on insertion/removal performance of hand-cast, milled and 3D printed splints
- 1 September 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 121, 104612
Pilot in-vitro study on insertion/removal performance of hand-cast, milled and 3D printed splints
- Open Access
- 28 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (13) , 6013
Transfer Accuracy of Two 3D Printed Trays for Indirect Bracket Bonding—An In Vitro Pilot Study
The present study aimed to investigate the impact of hardness from 3D printed transfer trays and dental crowding on bracket bonding accuracy. Lower models (no crowding group: Little’s Irregularity Index (LII) < 3, crowding group: LII > 7, n = 10 per group) were selected at random, digitized, 3D printed, and utilized for semiautomated virtual positioning of brackets and tubes. Hard and soft transfer trays were fabricated with polyjet printing and digital light processing, respectively. Brackets and tubes were transferred to the 3D printed models and altogether digitized using intraoral scanning (IOS) and microcomputed tomography (micro-CT) for assessment of linear and angular deviations. Mean intra- and interrater reliability amounted to 0.67 ± 0.34/0.79 ± 0.16 for IOS, and 0.92 ± 0.05/0.92 ± 0.5 for the micro-CT measurements. Minor linear discrepancies were observed (median: 0.11 mm, Q1–Q3: −0.06–0.28 mm). Deviations in torque (median: 2.49°, Q1–Q3: 1.27–4.03°) were greater than angular ones (median: 1.81°, Q1–Q3: 1.05°–2.90°), higher for hard (median: 2.49°, Q1–Q3: 1.32–3.91°) compared to soft (median: 1.77°, Q1–Q3: 0.94–3.01°) trays (p < 0.001), and torque errors were more pronounced at crowded front teeth (p < 0.05). In conclusion, the clinician should carefully consider the potential impact of hardness and crowding on bracket transfer accuracy, specifically in torque and angular orientation.
- 28 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (13) , 6013
Open AccessTransfer Accuracy of Two 3D Printed Trays for Indirect Bracket Bonding—An In Vitro Pilot Study
The present study aimed to investigate the impact of hardness from 3D printed transfer trays and dental crowding on bracket bonding accuracy. Lower models (no crowding group: Little’s Irregularity Index (LII) < 3, crowding group: LII > 7, n = 10 per group) were selected at random, digitized, 3D printed, and utilized for semiautomated virtual positioning of brackets and tubes. Hard and soft transfer trays were fabricated with polyjet printing and digital light processing, respectively. Brackets and tubes were transferred to the 3D printed models and altogether digitized using intraoral scanning (IOS) and microcomputed tomography (micro-CT) for assessment of linear and angular deviations. Mean intra- and interrater reliability amounted to 0.67 ± 0.34/0.79 ± 0.16 for IOS, and 0.92 ± 0.05/0.92 ± 0.5 for the micro-CT measurements. Minor linear discrepancies were observed (median: 0.11 mm, Q1–Q3: −0.06–0.28 mm). Deviations in torque (median: 2.49°, Q1–Q3: 1.27–4.03°) were greater than angular ones (median: 1.81°, Q1–Q3: 1.05°–2.90°), higher for hard (median: 2.49°, Q1–Q3: 1.32–3.91°) compared to soft (median: 1.77°, Q1–Q3: 0.94–3.01°) trays (p < 0.001), and torque errors were more pronounced at crowded front teeth (p < 0.05). In conclusion, the clinician should carefully consider the potential impact of hardness and crowding on bracket transfer accuracy, specifically in torque and angular orientation.