Viktor Nikolaevtsev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Viktor Nikolaevtsev has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Sergey G. Suchkov
Saratov State University
4 shared publications A. I. Timofeev
SPC Etna Plus, Saratov, Russia
2 shared publicationsD. S. Suchkov
Saratov State University, Saratov, Russia
2 shared publications- D. S. Suchkov2 shared publications
- Sergey G. Suchkov
Saratov State University, Saratov, Russia
2 shared publications V. V. Tretinnikov
SPC Etna Plus, Saratov, Russia
2 shared publications
Latest Publications
- 1 June 2026
- Published by Pleiades Publishing Ltd in Acoustical Physics
- Vol. 72 (3) , 328-332
Ultrasonic Noise Suppression in Gas Pipelines
The operation of ultrasonic flowmeters on gas pipelines near compressor stations is disrupted by powerful acoustic noise in the ultrasonic range, propagating both through the gas and along the pipe wall. To ensure reliable gas flow measurements, noise suppression in the operating frequency band of 90–110 kHz at the flowmeter location is required by at least 20 dB. This article proposes two new flowmeter protection methods based on noise reflection rather than absorption: for gas, a system of corner reflectors in pipe bends, and for pipe, a reflector consisting of coaxial ring resonators. Finite element modeling and optimization of the ring resonator system for ultrasonic suppression in the 85–115 kHz band by at least 30 dB are used. Experiments on a pipe segment with a flowmeter showed that when connecting devices implementing the indicated methods, the ultrasonic flowmeters maintain their efficiency under extreme operating noise conditions.
- 1 June 2026
- Published by Pleiades Publishing Ltd in Acoustical Physics
- Vol. 72 (3) , 328-332
Ultrasonic Noise Suppression in Gas Pipelines
The operation of ultrasonic flowmeters on gas pipelines near compressor stations is disrupted by powerful acoustic noise in the ultrasonic range, propagating both through the gas and along the pipe wall. To ensure reliable gas flow measurements, noise suppression in the operating frequency band of 90–110 kHz at the flowmeter location is required by at least 20 dB. This article proposes two new flowmeter protection methods based on noise reflection rather than absorption: for gas, a system of corner reflectors in pipe bends, and for pipe, a reflector consisting of coaxial ring resonators. Finite element modeling and optimization of the ring resonator system for ultrasonic suppression in the 85–115 kHz band by at least 30 dB are used. Experiments on a pipe segment with a flowmeter showed that when connecting devices implementing the indicated methods, the ultrasonic flowmeters maintain their efficiency under extreme operating noise conditions.
- Open Access
- 21 February 2025
- Published by Saratov State University in Izvestiya of Saratov University. New Series. Series: Mathematics. Mechanics. Informatics
- Vol. 25 (1)
Mathematical models for processing and interpreting seismic data in a new seismic survey method
- 21 February 2025
- Published by Saratov State University in Izvestiya of Saratov University. New Series. Series: Mathematics. Mechanics. Informatics
- Vol. 25 (1)
Open AccessMathematical models for processing and interpreting seismic data in a new seismic survey method
- 1 June 2024
- Published by Kotelnikov Institute of Radioengineering and Electronics of Russian Academy of Sciences in Journal of Radio Electronics
- Vol. 2024 (6)
Possibility of creating effective surface acoustic waves devices at frequency above 6 GHz
In the paper the interaction of surface acoustic waves (SAWs) with reflectors and interdigital transducers (IDTs) with high aspect ratio electrodes (HAR-electrodes) are investigated. The conditions for the SAW resonant reflection and propagation and the effective IDT conversion of the SAW power into electrical power at the load have been obtained. The real possibility of the effective SAW devices creation (filters, delay lines, resonators, RFID tags) at frequencies above 6 GHz (up to 12-15 GHz) using HAR-electrodes was demonstrated.
- 1 June 2024
- Published by Kotelnikov Institute of Radioengineering and Electronics of Russian Academy of Sciences in Journal of Radio Electronics
- Vol. 2024 (6)
Possibility of creating effective surface acoustic waves devices at frequency above 6 GHz
In the paper the interaction of surface acoustic waves (SAWs) with reflectors and interdigital transducers (IDTs) with high aspect ratio electrodes (HAR-electrodes) are investigated. The conditions for the SAW resonant reflection and propagation and the effective IDT conversion of the SAW power into electrical power at the load have been obtained. The real possibility of the effective SAW devices creation (filters, delay lines, resonators, RFID tags) at frequencies above 6 GHz (up to 12-15 GHz) using HAR-electrodes was demonstrated.
- 1 June 2023
- Published by Pleiades Publishing Ltd in Acoustical Physics
- Vol. 69 (3) , 381-387
Sound Generation by Metro Trains during Braking and Its Suppression Method
The causes of acoustic noise occurring during braking of electric vehicles, in particular, in the metro, were analyzed. The spectrum of such noise was measured, and it is shown that high-frequency discrete tones are excited by braking resistors, applied for electrodynamic braking of electric vehicles. Three proposed mechanisms of electromechanical interaction in a Fecral plate, which is a braking resistor element, were considered: the Ampère force and linear and nonlinear magnetostriction. It was shown that predominant odd harmonics indicate the presence of a significant piezomagnetic effect and the inverse effect of linear magnetostriction in the Fecral alloy. A phenomenological approach was used to calculate the piezomagnetic tensor elements for Fecral. Calculations by the finite element method showed that asymmetric cuts introduced into the plate may significantly decrease intensity of acoustic vibrations excited by the braking resistor.
- 1 June 2023
- Published by Pleiades Publishing Ltd in Acoustical Physics
- Vol. 69 (3) , 381-387
Sound Generation by Metro Trains during Braking and Its Suppression Method
The causes of acoustic noise occurring during braking of electric vehicles, in particular, in the metro, were analyzed. The spectrum of such noise was measured, and it is shown that high-frequency discrete tones are excited by braking resistors, applied for electrodynamic braking of electric vehicles. Three proposed mechanisms of electromechanical interaction in a Fecral plate, which is a braking resistor element, were considered: the Ampère force and linear and nonlinear magnetostriction. It was shown that predominant odd harmonics indicate the presence of a significant piezomagnetic effect and the inverse effect of linear magnetostriction in the Fecral alloy. A phenomenological approach was used to calculate the piezomagnetic tensor elements for Fecral. Calculations by the finite element method showed that asymmetric cuts introduced into the plate may significantly decrease intensity of acoustic vibrations excited by the braking resistor.
- 1 May 2023
- Published by The Russian Academy of Sciences in Akustičeskij žurnal
- Vol. 69 (3) , 367-373
Sound Generation by Metro Trains during Braking and Its Suppression Method
О генерации звука поездами метро при торможении и метод его подавления
- 1 May 2023
- Published by The Russian Academy of Sciences in Akustičeskij žurnal
- Vol. 69 (3) , 367-373
Sound Generation by Metro Trains during Braking and Its Suppression Method
О генерации звука поездами метро при торможении и метод его подавления
- 25 October 2022
- Published by Vitebsk State Medical University in Novosti Khirurgii
- Vol. 30 (5) , 425-433
The Estimation of the Blood Supply and Viability of Biological Tissues Using a Potable Capacitive Sensor
Цель. Поиск оптимальных временных интервалов применения ёмкостного сенсора и получение с его помощью универсальных нормированных показателей кровенаполнения и жизнеспособности тканей в интересах медицины катастроф и неотложной хирургии. Материал и методы. Используется факт значительного различия диэлектрической проницаемости тканей, не наполненных кровью, и диэлектрической проницаемости крови. Поэтому уровень кровенаполнения ткани можно характеризовать величиной измеренной ёмкости СТ(t) электродной структуры, приложенной к ткани. Для исследования влияния кровенаполнения и жизнеспособности биологических тканей на показания ёмкостного сенсора были проведены эксперименты на 20 самцах белых лабораторных крыс массой 200-250 г. В первой группе из 10 животных проводили исследование показателей СТ(t) на коже бедра в течение 10 секунд с фиксацией результатов каждые 5 секунд до введения адреналина и через 5 минут после его введения. Во второй группе из 10 животных были проведены измерения СТ(t) на коже бедра в течение 1 минуты с фиксацией значений ёмкости через каждые 10 секунд для определения универсальных нормированных показателей кровенаполнения и жизнеспособности СN(t). Оценку значимости различий парных измерений абсолютных значений СТ(t) проводили по критерию Уилкоксона. Для определения значимости различий между предложенными нормированными показателями СN(t) у живых и мертвых животных использовали критерий Стьюдента. Результаты. Прибор показал достаточную чувствительность при изменении кровенаполнения кожи в ответ на введения адреналина. Показатели ёмкостного сенсора у живых животных быстро и статистически значимо растут в течение одной минуты непрерывного измерения в отличие от мертвых тканей, где показатели не меняются. Установлено, что необходимую и достаточную информацию предоставляют значения ёмкости на десятой и двадцатой секундах измерения. Результаты измерений показали значительный разброс абсолютных значений ёмкости сенсора у разных животных, но близкую динамику нарастания этих показателей в одинаковых условиях эксперимента. Эти данные позволили рассчитать универсальные нормированные показатели для практического применения ёмкостного сенсора. Заключение. Предложенный компактный автономный ёмкостный сенсор имеет перспективы применения в неотложной и сосудистой хирургии для экстренной оценки кровенаполнения и жизнеспособности тканей и органов пациентов. Установлены оптимальные временные промежутки и нормированные показатели выполняемых измерений.
- 25 October 2022
- Published by Vitebsk State Medical University in Novosti Khirurgii
- Vol. 30 (5) , 425-433
The Estimation of the Blood Supply and Viability of Biological Tissues Using a Potable Capacitive Sensor
Цель. Поиск оптимальных временных интервалов применения ёмкостного сенсора и получение с его помощью универсальных нормированных показателей кровенаполнения и жизнеспособности тканей в интересах медицины катастроф и неотложной хирургии. Материал и методы. Используется факт значительного различия диэлектрической проницаемости тканей, не наполненных кровью, и диэлектрической проницаемости крови. Поэтому уровень кровенаполнения ткани можно характеризовать величиной измеренной ёмкости СТ(t) электродной структуры, приложенной к ткани. Для исследования влияния кровенаполнения и жизнеспособности биологических тканей на показания ёмкостного сенсора были проведены эксперименты на 20 самцах белых лабораторных крыс массой 200-250 г. В первой группе из 10 животных проводили исследование показателей СТ(t) на коже бедра в течение 10 секунд с фиксацией результатов каждые 5 секунд до введения адреналина и через 5 минут после его введения. Во второй группе из 10 животных были проведены измерения СТ(t) на коже бедра в течение 1 минуты с фиксацией значений ёмкости через каждые 10 секунд для определения универсальных нормированных показателей кровенаполнения и жизнеспособности СN(t). Оценку значимости различий парных измерений абсолютных значений СТ(t) проводили по критерию Уилкоксона. Для определения значимости различий между предложенными нормированными показателями СN(t) у живых и мертвых животных использовали критерий Стьюдента. Результаты. Прибор показал достаточную чувствительность при изменении кровенаполнения кожи в ответ на введения адреналина. Показатели ёмкостного сенсора у живых животных быстро и статистически значимо растут в течение одной минуты непрерывного измерения в отличие от мертвых тканей, где показатели не меняются. Установлено, что необходимую и достаточную информацию предоставляют значения ёмкости на десятой и двадцатой секундах измерения. Результаты измерений показали значительный разброс абсолютных значений ёмкости сенсора у разных животных, но близкую динамику нарастания этих показателей в одинаковых условиях эксперимента. Эти данные позволили рассчитать универсальные нормированные показатели для практического применения ёмкостного сенсора. Заключение. Предложенный компактный автономный ёмкостный сенсор имеет перспективы применения в неотложной и сосудистой хирургии для экстренной оценки кровенаполнения и жизнеспособности тканей и органов пациентов. Установлены оптимальные временные промежутки и нормированные показатели выполняемых измерений.
- 1 January 2020
- Published by Springer Nature
- p. 94-104
Method of Frequency Coding in Microwave RFID