EGEmanuel Gautier

Emanuel Gautier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Emanuel Gautier has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enabling hydrogel coating on silicone breast implants with a poly(vinyl acetate) primer layer

    by Katrin Stanger, Dardan Bajrami, Peter Wahl, Fintan Moriarty, Emanuel Gautier, Alex Jean Dommann, Kongchang Wei

    A poly(vinyl acetate) primer layer enables coating of silicone breast implants with hydrogels to prevent implant-associated infections.


  • Design features of the rotating head total hip arthroplasty by Weber-Huggler– a forgotten technical solution to reduce wear

    by Hanna Wellauer, Emanuel Gautier, Claude Rieker, Robin Pourzal, Peter Wahl

    Total hip arthroplasty (THA) is a very successful operation. Once the problem of implant fixation was solved with the use of bone cement, the next development steps focused on improving the bearing. Weber, a Swiss surgeon, introduced the first modular heads in THA. His design improved reconstruction of the patients’ anatomy using various neck lengths, eased revision as well-fixed stems could be preserved, and also reduced wear due to a cylindrical, rotating connection between the head and neck. The features and results of this exceptional design are reviewed. However, as newer material combinations greatly mitigated the problem of wear and as the dimensions of the cylindrical connection limit range of motion, it was supplanted by the nowadays well-established Morse taper connection, which also is less complex to manufacture. As Weber’s design was associated with good long-term results, the technical features of this technical solution should not be forgotten.

  • Open Access

    Correlation of cross-linking as measured by the trans-vinylene index and in vitro wear of polyethylene from various acetabular liner brands

    by Peter Wahl, Roman Heuberger, Andrea Pascucci, Thomas Imwinkelried, Markus Fürstner, Niels Icken, Michel Schläppi, Robin Pourzal, Emanuel Gautier

    Aims: Highly cross-linked polyethylene (HXLPE) greatly reduces wear in total hip arthroplasty, compared to conventional polyethylene (CPE). Cross-linking is commonly achieved by irradiation. This study aimed to compare the degree of cross-linking and in vitro wear rates across a cohort of retrieved and unused polyethylene cups/liners from various brands.Methods: Polyethylene acetabular cups/liners were collected at one centre from 1 April 2021 to 30 April 2022. The trans-vinylene index (TVI) and oxidation index (OI) were determined by Fourier-transform infrared spectrometry. Wear was measured using a pin-on-disk test.Results: A total of 47 specimens from ten brands were included. The TVI was independent of time in vivo. A linear correlation (R2 = 0.995) was observed between the old and current TVI standards, except for vitamin E-containing polyethylene. The absorbed irradiation dose calculated from the TVI corresponded to product specifications for all but two products. For one electron beam-irradiated HXLPE, a mean dose of 241% (SD 18%) of specifications was determined. For another, gamma-irradiated HXLPE, a mean 41% (SD 13%) of specifications was determined. Lower wear was observed for higher TVI.Conclusion: The TVI is a reliable measure of the absorbed irradiation dose and does not alter over time in vivo. The products of various brands differ by manufacturing details and consequently cross-linking characteristics. Absorption and penetration of electron radiation and gamma radiation differ, potentially leading to higher degrees of cross-linking for electron radiation. There is a non-linear, inverse correlation between TVI and in vitro wear. The wear resistance of the HXLPE with low TVI was reduced and more comparable to CPE.Cite this article: Bone Joint Res 2024;13(11):682–693.


  • Open Access

    Symptomatic Osteonecrosis of the Femoral Diaphysis Induced by Internal Plate Fixation of a Periprosthetic Fracture

    by Hanna Wellauer, Emanuel Gautier, Bernd Klaeser, Niklaus Meyer, Christoph Meier, Peter Wahl

    Periprosthetic fractures of the proximal femur are one of the most frequent causes of revision after total hip arthroplasty. Internal fixation may be chosen if the hip implant is stable or if a stable fixation may be obtained. Preservation of bone perfusion and adequate stability are essential for successful fracture healing. As presented in this report, a patient developed both osteonecrosis and atrophy of the cortical bone due to use of a specific plate to treat a periprosthetic fracture of the femur. An 82-year-old female sustained a periprosthetic fracture of the proximal femur two years after cemented hemiarthroplasty. The fracture was treated by plate fixation. Along the proximal femoral diaphysis, cerclages were applied to avoid interference of screws with the femoral stem. Due to postoperative restrictions and finally due to pain, the patient never could be mobilized out of a wheelchair. After 4 years, pain persisted while the fracture had healed without loosening of the joint replacement components. However, pronounced atrophy of the whole femur was present, with devitalized areas of the bone underlying the plate. When not strictly applied as an internal fixator at a distance from the bone, the plate model used in this case may disturb periosteal blood flow, causing osteonecrosis. Furthermore, high bending rigidity of the plate-bone construct may lead to stress shielding and atrophy. The case illustrates that design and mechanical properties of a plate are relevant in bone biology and healing.conclusions. Clinical trial abstracts should include items that the CONSORT group has identified as essential.

  • Open Access

    Surface repair of the femoral head using press-osteochondral autograft transfer

    by Caroline Passaplan, Matthieu Hanauer, Lucienne Gautier, Vera M. Stetzelberger, Joseph M. Schwab, Moritz Tannast, Emanuel Gautier

    Aims: Hyaline cartilage has a low capacity for regeneration. Untreated osteochondral lesions of the femoral head can lead to progressive and symptomatic osteoarthritis of the hip. The purpose of this study is to analyze the clinical and radiological long-term outcome of patients treated with osteochondral autograft transfer. To our knowledge, this study represents a series of osteochondral autograft transfer of the hip with the longest follow-up.Methods: We retrospectively evaluated 11 hips in 11 patients who underwent osteochondral autograft transfer in our institution between 1996 and 2012. The mean age at the time of surgery was 28.6 years (8 to 45). Outcome measurement included standardized scores and conventional radiographs. Kaplan-Meier survival curve was used to determine the failure of the procedures, with conversion to total hip arthroplasty (THA) defined as the endpoint.Results: The mean follow-up of patients treated with osteochondral autograft transfer was 18.5 years (9.3 to 24.7). Six patients developed osteoarthritis and had a THA at a mean of 10.3 years (1.1 to 17.3). The cumulative survivorship of the native hips was 91% (95% confidence interval (CI) 74 to 100) at five years, 62% (95% CI 33 to 92) at ten years, and 37% (95% CI 6 to 70) at 20 years.Conclusion: This is the first study analyzing the long-term results of osteochondral autograft transfer of the femoral head. Although most patients underwent conversion to THA in the long term, over half of them survived more than ten years. Osteochondral autograft transfer could be a time-saving procedure for young patients with devastating hip conditions who have virtually no other surgical options. A larger series or a similar matched cohort would be necessary to confirm these results which, in view of the heterogeneity of our series, seems difficult to achieve.Cite this article: Bone Jt Open 2023;4(7):523–531.


  • Open Access

    Wound fluid ceftriaxone concentrations after local application with calcium sulphate as carrier material in the treatment of orthopaedic device-associated hip infections

    by Matthias G. Wiesli, Françoise Livio, Yvonne Achermann, Emanuel Gautier, Peter Wahl

    Aims There is a considerable challenge in treating bone infections and orthopaedic device-associated infection (ODAI), partly due to impaired penetration of systemically administrated antibiotics at the site of infection. This may be circumvented by local drug administration. Knowledge of the release kinetics from any carrier material is essential for proper application. Ceftriaxone shows a particular constant release from calcium sulphate (CaSO4) in vitro, and is particularly effective against streptococci and a large portion of Gram-negative bacteria. We present the clinical release kinetics of ceftriaxone-loaded CaSO4 applied locally to treat ODAI. Methods A total of 30 operations with ceftriaxone-loaded CaSO4 had been performed in 28 patients. Ceftriaxone was applied as a single local antibiotic in 21 operations and combined with vancomycin in eight operations, and in an additional operation with vancomycin and amphotericin B. Sampling of wound fluid was performed from drains or aspirations. Ceftriaxone concentrations were measured by liquid chromatography with tandem mass spectrometry (LC-MS/MS). Results A total of 37 wound fluid concentrations from 16 operations performed in 14 patients were collected. The ceftriaxone concentrations remained approximately within a range of 100 to 200 mg/l up to three weeks. The median concentration was 108.9 mg/l (interquartile range 98.8 to 142.5) within the first ten days. No systemic adverse reactions were observed. Conclusion Our study highlights new clinical data of locally administered ceftriaxone with CaSO4 as carrier material. The near-constant release of ceftriaxone from CaSO4 observed in vitro could be confirmed in vivo. The concentrations remained below known local toxicity thresholds. Cite this article: Bone Joint Res 2022;11(11):835–842.


  • Open Access

    The Incidence of Severe Hypercalcaemia-Induced Mental Status Changes in Patients Treated with Antibiotic-Loaded Calcium Sulphate Depot for Orthopaedic Infections

    by Faustine Vallon, Christoph Meier, Emanuel Gautier, Peter Wahl

    Local application of antibiotics with calcium-containing carrier materials (CCCM) might deliver large quantities of calcium, with some cases of hypercalcaemia reported. The incidence of symptomatic hypercalcaemia was estimated retrospectively in a consecutive, prospective series of patients treated between 10/2006 and 02/2019 with antibiotic-loaded CCCM for various orthopaedic infections. Risk factors were analysed. In the study period, 215 CCCM applications were performed. Two patients (0.9%) developed symptomatic hypercalcaemia. In one case, hypercalcaemia occurred 14 days after a second CCCM application during a staged septic hip revision. In the other case, hypercalcaemia became symptomatic six days after application of vancomycin-loaded CCCM in a component-retaining septic revision hip arthroplasty. In both cases, hypercalcemia was not imputable solely to the CCCM. Prolonged immobilization, renal impairment and other specific risk factors were present. Implantation of a CCCM for local application of antibiotics exposes the patient to large quantities of calcium during dissolution. This might induce symptomatic hypercalcaemia, a potentially life-threatening complication. The observed incidence of symptomatic hypercalcaemia remained rare (<1%). In some patients, compensatory mechanisms might be overwhelmed in the presence of other risk factors. Postoperative monitoring of calcaemia as well as elimination of risk factors is mandatory for all patients treated with CCCM.


  • Open Access

    Retrograde Intramedullary Nailing for Bado Types Proximal Pediatric Ulna Fractures: Different Surgical Techniques

    by Grégoire Thürig, Ines Raabe, Mauro Maniglio, Philippe Vial, Moritz Tannast, Emanuel Gautier

    Introduction: Monteggia fracture is defined as a fracture of the proximal third of the ulna with associated dislocation of the radial head. According to the Bado classification, 4 types are differentiated. These fracture types are rare in both adults and children, reaching an incidence of 1.5 - 3% of all pediatric forearm fractures. Anatomic reduction and retention of ulnar fracture and radial head dislocation is the primary aim. If surgery is indicated, various methods can be used. However, it is not known whether one is superior to the other. In very proximal ulnar fracture with radial head dislocation, it is not known whether retrograde nailing provides effective retention of the fracture. Our hypothesis is that closed retrograde nailing is a safe method in the treatment of proximal Bado type I-III in children. Materials and Methods: For this retrospective case series, all pediatric patients were included who suffered a proximal Bado fracture between November 2000 and August 2019. Demographics, injury patterns, details of surgical treatment, and radiographs were obtained from medical records. Results: Results: Six pediatric cases (two to six years old, two girls and four boys). They all had a proximal Bado fracture. Closed reduction and retention using retrograde nailing of the ulna was performed in all cases. There were no infections, vascular or nerve injuries. There was one reoperation due to incorrect application of the technique. All patients were pain free and had the same range of motion as on the contralateral side. Conclusion: Indirect reduction and intramedullary retrograde nailing is a minimally invasive technique that do not affect the blood supply of the bone and soft tissues. This technique allows for safe treatment of Bado type I-III fractures in children.