Hanna Wellauer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hanna Wellauer has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Emanuel Gautier
Department of Orthopaedic Surgery, HFR Fribourg - Cantonal Hospital, Fribourg, Switzerland
3 shared publicationsMoritz Tannast
Department of Orthopaedics, HFR Fribourg - Cantonal Hospital, Fribourg, Switzerland
3 shared publicationsPeter Wahl
ARTORG Center of Biomedical Engineering Research, Faculty of Medicine, University of Bern, Bern, Switzerland
3 shared publications- Peter Wahl
Department Biomedical Engineering, University of Basel, Hegenheimermattstrasse 167 B/C, 4123 Allschwil, Switzerland
3 shared publications - Emanuel Gautier
Department of Orthopaedic Surgery HFR Fribourg – Cantonal Hospital Fribourg Switzerland
2 shared publications Hubert Steinke
Institute for the History of Medicine, University of Bern, Bern, Switzerland
2 shared publications
Latest Publications
- 23 January 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-8
Design features of the rotating head total hip arthroplasty by Weber-Huggler– a forgotten technical solution to reduce wear
Total hip arthroplasty (THA) is a very successful operation. Once the problem of implant fixation was solved with the use of bone cement, the next development steps focused on improving the bearing. Weber, a Swiss surgeon, introduced the first modular heads in THA. His design improved reconstruction of the patients’ anatomy using various neck lengths, eased revision as well-fixed stems could be preserved, and also reduced wear due to a cylindrical, rotating connection between the head and neck. The features and results of this exceptional design are reviewed. However, as newer material combinations greatly mitigated the problem of wear and as the dimensions of the cylindrical connection limit range of motion, it was supplanted by the nowadays well-established Morse taper connection, which also is less complex to manufacture. As Weber’s design was associated with good long-term results, the technical features of this technical solution should not be forgotten.
- 23 January 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-8
Design features of the rotating head total hip arthroplasty by Weber-Huggler– a forgotten technical solution to reduce wear
Total hip arthroplasty (THA) is a very successful operation. Once the problem of implant fixation was solved with the use of bone cement, the next development steps focused on improving the bearing. Weber, a Swiss surgeon, introduced the first modular heads in THA. His design improved reconstruction of the patients’ anatomy using various neck lengths, eased revision as well-fixed stems could be preserved, and also reduced wear due to a cylindrical, rotating connection between the head and neck. The features and results of this exceptional design are reviewed. However, as newer material combinations greatly mitigated the problem of wear and as the dimensions of the cylindrical connection limit range of motion, it was supplanted by the nowadays well-established Morse taper connection, which also is less complex to manufacture. As Weber’s design was associated with good long-term results, the technical features of this technical solution should not be forgotten.
- Open Access
- 1 January 2025
- Published by Indian Orthopaedic Research Group in Journal of Orthopaedic Case Reports
- Vol. 15 (11) , 208-216
A Case Report of a Symptomatic Atrophy and Osteonecrosis of the Femoral Diaphysis In-duced by Internal Plate Fixation of a Periprosthetic Fracture
Introduction: Periprosthetic fractures (PPF) of the proximal femur are a leading cause of revision after total hip arthroplasty. Internal fixation may be chosen if the hip implant is stable or if a stable fixation may be obtained. Preservation of bone perfusion and adequate stability are essential for successful fracture healing. As presented, plate design and applica-tion may induce both osteonecrosis and atrophy of the bone. Case Report: An 82-year-old female sustained a PPF of the proximal femur after cemented hemiarthroplasty. The fracture was treated by plate fixation with cerclages applied at the level of the femoral stem. While the fracture healed without loosening of the components, pronounced atrophy of the whole femur developed, with devitalized areas of the bone un-derlying the plate. The plate used had no undercuts and probably had excessive stiffness. Conclusion: When not strictly applied as an internal fixator at a distance from the bone, the plate model used in this case may disturb periosteal blood flow, causing osteonecrosis. Fur-thermore, high bending rigidity of the plate-bone construct may lead to stress shielding and atrophy. Design and mechanical properties of a plate are relevant in fracture healing. Keywords: Periprosthetic fracture, plate fixation, internal fixation, bone biology, bone ne-crosis, plate contact.
- 1 January 2025
- Published by Indian Orthopaedic Research Group in Journal of Orthopaedic Case Reports
- Vol. 15 (11) , 208-216
Open AccessA Case Report of a Symptomatic Atrophy and Osteonecrosis of the Femoral Diaphysis In-duced by Internal Plate Fixation of a Periprosthetic Fracture
Introduction: Periprosthetic fractures (PPF) of the proximal femur are a leading cause of revision after total hip arthroplasty. Internal fixation may be chosen if the hip implant is stable or if a stable fixation may be obtained. Preservation of bone perfusion and adequate stability are essential for successful fracture healing. As presented, plate design and applica-tion may induce both osteonecrosis and atrophy of the bone. Case Report: An 82-year-old female sustained a PPF of the proximal femur after cemented hemiarthroplasty. The fracture was treated by plate fixation with cerclages applied at the level of the femoral stem. While the fracture healed without loosening of the components, pronounced atrophy of the whole femur developed, with devitalized areas of the bone un-derlying the plate. The plate used had no undercuts and probably had excessive stiffness. Conclusion: When not strictly applied as an internal fixator at a distance from the bone, the plate model used in this case may disturb periosteal blood flow, causing osteonecrosis. Fur-thermore, high bending rigidity of the plate-bone construct may lead to stress shielding and atrophy. Design and mechanical properties of a plate are relevant in fracture healing. Keywords: Periprosthetic fracture, plate fixation, internal fixation, bone biology, bone ne-crosis, plate contact.
- Open Access
- 6 November 2024
- Published by MDPI AG in Preprints.org
Symptomatic Osteonecrosis of the Femoral Diaphysis Induced by Internal Plate Fixation of a Periprosthetic Fracture
Periprosthetic fractures of the proximal femur are one of the most frequent causes of revision after total hip arthroplasty. Internal fixation may be chosen if the hip implant is stable or if a stable fixation may be obtained. Preservation of bone perfusion and adequate stability are essential for successful fracture healing. As presented in this report, a patient developed both osteonecrosis and atrophy of the cortical bone due to use of a specific plate to treat a periprosthetic fracture of the femur. An 82-year-old female sustained a periprosthetic fracture of the proximal femur two years after cemented hemiarthroplasty. The fracture was treated by plate fixation. Along the proximal femoral diaphysis, cerclages were applied to avoid interference of screws with the femoral stem. Due to postoperative restrictions and finally due to pain, the patient never could be mobilized out of a wheelchair. After 4 years, pain persisted while the fracture had healed without loosening of the joint replacement components. However, pronounced atrophy of the whole femur was present, with devitalized areas of the bone underlying the plate. When not strictly applied as an internal fixator at a distance from the bone, the plate model used in this case may disturb periosteal blood flow, causing osteonecrosis. Furthermore, high bending rigidity of the plate-bone construct may lead to stress shielding and atrophy. The case illustrates that design and mechanical properties of a plate are relevant in bone biology and healing.conclusions. Clinical trial abstracts should include items that the CONSORT group has identified as essential.
- 6 November 2024
- Published by MDPI AG in Preprints.org
Open AccessSymptomatic Osteonecrosis of the Femoral Diaphysis Induced by Internal Plate Fixation of a Periprosthetic Fracture
Periprosthetic fractures of the proximal femur are one of the most frequent causes of revision after total hip arthroplasty. Internal fixation may be chosen if the hip implant is stable or if a stable fixation may be obtained. Preservation of bone perfusion and adequate stability are essential for successful fracture healing. As presented in this report, a patient developed both osteonecrosis and atrophy of the cortical bone due to use of a specific plate to treat a periprosthetic fracture of the femur. An 82-year-old female sustained a periprosthetic fracture of the proximal femur two years after cemented hemiarthroplasty. The fracture was treated by plate fixation. Along the proximal femoral diaphysis, cerclages were applied to avoid interference of screws with the femoral stem. Due to postoperative restrictions and finally due to pain, the patient never could be mobilized out of a wheelchair. After 4 years, pain persisted while the fracture had healed without loosening of the joint replacement components. However, pronounced atrophy of the whole femur was present, with devitalized areas of the bone underlying the plate. When not strictly applied as an internal fixator at a distance from the bone, the plate model used in this case may disturb periosteal blood flow, causing osteonecrosis. Furthermore, high bending rigidity of the plate-bone construct may lead to stress shielding and atrophy. The case illustrates that design and mechanical properties of a plate are relevant in bone biology and healing.conclusions. Clinical trial abstracts should include items that the CONSORT group has identified as essential.
- Open Access
- 1 February 2024
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 9 (2) , 148-149
Reply to the Letter to the editor from Grappiolo G et al. to the article ‘The History of the development of the regular straight stem in hip arthroplasty’
"Reply to the Letter to the editor from Grappiolo G et al. to the article ‘The History of the development of the regular straight stem in hip arthroplasty’" published on 01 Feb 2024 by Bioscientifica Ltd.
- 1 February 2024
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 9 (2) , 148-149
Open AccessReply to the Letter to the editor from Grappiolo G et al. to the article ‘The History of the development of the regular straight stem in hip arthroplasty’
"Reply to the Letter to the editor from Grappiolo G et al. to the article ‘The History of the development of the regular straight stem in hip arthroplasty’" published on 01 Feb 2024 by Bioscientifica Ltd.
- Open Access
- 11 January 2024
- Published by Elsevier in Arthroplasty Today
- Vol. 25, 101313
Successful Implant Retention in a Chronified Hematogenous Bilateral Periprosthetic Hip Joint Infection With Enterococcus faecalis
- 11 January 2024
- Published by Elsevier in Arthroplasty Today
- Vol. 25, 101313
Open AccessSuccessful Implant Retention in a Chronified Hematogenous Bilateral Periprosthetic Hip Joint Infection With Enterococcus faecalis
- 1 January 2024
- Published by Springer Nature
- p. 443-454
Joint Preservation Surgeries Utilizing Surgical Dislocation of the Hip
- 1 January 2024
- Published by Springer Nature
- p. 443-454
Joint Preservation Surgeries Utilizing Surgical Dislocation of the Hip
- Open Access
- 3 July 2023
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 8 (7) , 548-560
The history of the development of the regular straight stem in hip arthroplasty
Since the middle of the 20th century, total hip arthroplasty has become a very successful treatment for all end-stage diseases of the hip joint. Charnley solved with his low frictional torque arthroplasty the problem of wear and friction with the introduction of a new bearing couple and the reduction of the head size, which set the prerequisite for the further development of stem design. This narrative review presents the major developments of regular straight stems in hip arthroplasty. It does not only provide an overview of the history but also assembles the generally scarce documentation available regarding the rationale of developments and illustrates often-unsuspected links. Charnley's success is based on successfully solving the issue of fixation of the prosthetic components to the bone, using bone cement made of polymethyl-methacrylate. In the field of cemented anchorage of the stem, two principles showing good long-term revision rates emerged over the years: the force-closed and the shape-closed principles. The non-cemented anchorage bases on prosthesis models ensure enough primary stability for osteointegration of the implant to occur. For bone to grow onto the surface, not only sufficient primary stability is required but also a suitable surface structure together with a biocompatible prosthetic material is also necessary.
- 3 July 2023
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 8 (7) , 548-560
Open AccessThe history of the development of the regular straight stem in hip arthroplasty
Since the middle of the 20th century, total hip arthroplasty has become a very successful treatment for all end-stage diseases of the hip joint. Charnley solved with his low frictional torque arthroplasty the problem of wear and friction with the introduction of a new bearing couple and the reduction of the head size, which set the prerequisite for the further development of stem design. This narrative review presents the major developments of regular straight stems in hip arthroplasty. It does not only provide an overview of the history but also assembles the generally scarce documentation available regarding the rationale of developments and illustrates often-unsuspected links. Charnley's success is based on successfully solving the issue of fixation of the prosthetic components to the bone, using bone cement made of polymethyl-methacrylate. In the field of cemented anchorage of the stem, two principles showing good long-term revision rates emerged over the years: the force-closed and the shape-closed principles. The non-cemented anchorage bases on prosthesis models ensure enough primary stability for osteointegration of the implant to occur. For bone to grow onto the surface, not only sufficient primary stability is required but also a suitable surface structure together with a biocompatible prosthetic material is also necessary.
- Open Access
Time and Accuracy to Establish the Diagnosis of Soft Tissue Tumors: A Comparative Analysis from the Swiss Sarcoma Network
Soft tissue tumors are rare tumors, and their histological examination remains a challenge. The establishment of the correct initial histopathologic diagnosis is critical. However, due to the rarity of soft tissue and bone tumors and the inherent difficulty of their classification and diagnostics, discrepancies may occur in up to one third of cases. For these reasons, several studies recommend the involvement of experienced pathologists frequently performing sarcoma diagnostics. Until now, there is only scarce information about how long it takes to establish a correct sarcoma diagnosis. We thus analyzed all consecutive patients presented to the Swiss Sarcoma Network Tumor Board (SSN-MDT/SB) with a primary diagnosis of a soft tissue tumor over a 2-year period (01/2019 to 12/2020) based on a tumor biopsy. We then compared the final histopathological diagnosis of two comparable institutions with similar case load, but different workflows: (i) institution A, with an initial diagnosis performed by a local pathologist, and reviewed by a reference pathologist, and (ii) institution B, with the final diagnosis performed directly by a reference pathologist. In addition, we analyzed the time from biopsy to establishment of the diagnosis. A total of 347 cases were analyzed, 196 from institution A, and 149 from institution B. In 77.6% of the cases, the diagnosis from the local pathologist was concordant with the expert review. Minor discrepancies were found in 10.2% of the cases without any consecutive changes in treatment strategy. In the remaining 12.2% of the cases, there were major discrepancies which influenced the treatment strategy directly. Establishing the final report took significantly longer in institution A (4.7 working days) than in institution B (3.3 working days; ). Our results confirm the importance of a pathological second review by a reference pathologist. We recommend direct analysis by experts, as diagnoses can be made more accurately and quickly. Within the SSN, establishing the sarcoma diagnosis is overall accurate and quick but still can be improved.
Open AccessTime and Accuracy to Establish the Diagnosis of Soft Tissue Tumors: A Comparative Analysis from the Swiss Sarcoma Network
Soft tissue tumors are rare tumors, and their histological examination remains a challenge. The establishment of the correct initial histopathologic diagnosis is critical. However, due to the rarity of soft tissue and bone tumors and the inherent difficulty of their classification and diagnostics, discrepancies may occur in up to one third of cases. For these reasons, several studies recommend the involvement of experienced pathologists frequently performing sarcoma diagnostics. Until now, there is only scarce information about how long it takes to establish a correct sarcoma diagnosis. We thus analyzed all consecutive patients presented to the Swiss Sarcoma Network Tumor Board (SSN-MDT/SB) with a primary diagnosis of a soft tissue tumor over a 2-year period (01/2019 to 12/2020) based on a tumor biopsy. We then compared the final histopathological diagnosis of two comparable institutions with similar case load, but different workflows: (i) institution A, with an initial diagnosis performed by a local pathologist, and reviewed by a reference pathologist, and (ii) institution B, with the final diagnosis performed directly by a reference pathologist. In addition, we analyzed the time from biopsy to establishment of the diagnosis. A total of 347 cases were analyzed, 196 from institution A, and 149 from institution B. In 77.6% of the cases, the diagnosis from the local pathologist was concordant with the expert review. Minor discrepancies were found in 10.2% of the cases without any consecutive changes in treatment strategy. In the remaining 12.2% of the cases, there were major discrepancies which influenced the treatment strategy directly. Establishing the final report took significantly longer in institution A (4.7 working days) than in institution B (3.3 working days; ). Our results confirm the importance of a pathological second review by a reference pathologist. We recommend direct analysis by experts, as diagnoses can be made more accurately and quickly. Within the SSN, establishing the sarcoma diagnosis is overall accurate and quick but still can be improved.