Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Killian Cosendey has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Brigitte Jolles-Haeberli

    Lausanne University Hospital and University of Lausanne (CHUV-UNIL), Department of Musculoskeletal Medicine, Swiss BioMotion Lab, Lausanne, Switzerland

    4 shared publications
  • Julien Favre

    Lausanne University Hospital and University of Lausanne (CHUV-UNIL), Department of Orthopedic Surgery and Traumatology, BioMotion Center, Lausanne, Switzerland

    4 shared publications
  • Patrick Omoumi

    Lausanne University Hospital

    4 shared publications
  • Brigitte M. Jolles

    Department of Orthopedic Surgery and Traumatology, Lausanne University Hospital and University of Lausanne (CHUV-UNIL), Lausanne, Switzerland

    3 shared publications
  • Hugues Cadas

    Unite Facultaire d’Anatomie et de Morphologie (UFAM), University Center of Legal Medicine Lausanne-Geneva (CURML), Lausanne University Hospital, University of Lausanne, Lausanne, Switzerland

    3 shared publications
  • Julien Favre

    Department of Orthopedic Surgery and Traumatology, Lausanne University Hospital and University of Lausanne (CHUV-UNIL), Lausanne, Switzerland

    3 shared publications

Latest Publications

  • Open Access

    The usability of robotic-assisted systems for total knee arthroplasty can be improved without hindering the accuracy of the bone cuts

    by Killian Cosendey, Julien Stanovici, Jaad Mahlouly, Patrick Omoumi, Brigitte M. Jolles, Julien Favre

    Introduction: This study assessed the bone cuts accuracy of a robotic-assisted system for total knee arthroplasty (TKA) that was recently upgraded. Materials and methods: Three orthopaedic surgeons planned and executed TKA on 24 sawbones. Bone cut accuracy was assessed using CT scans, comparing the planning and the actual bone cuts in all six degrees-of-freedom. Results: The root-mean-square (RMS) values were below 2 mm or 2° for all error types, except for the medio-lateral position (2.4 mm) and internal-external rotation (2.3°) of the left tibias. The maximal amplitude of the 288 errors (6 degrees-of-freedom * 2 bones * 24 knees) was observed in tibial external rotation (3.2°). Most error types reported a bias, with limited variations among knees. Conclusions: The errors were in the same range as those of the prior version of the system, suggesting that the improvements brought by the system upgrade were not obtained at the expense of accuracy.

  • Open Access

    Intra- and inter-operator reliability of three-dimensional preoperative planning in total knee arthroplasty

    by Killian Cosendey, Kevin Moerenhout, Julien Stanovici, Brigitte M. Jolles, Julien Favre

    Purpose: To characterize the intra- and inter-operator reliability of a CT-based 3D preoperative planning software. Materials and methods: This study analyzed 30 CT scans of de-identified knees with osteoarthritis. For each scan, a case planner segmented the bones and pre-planned the TKA. Three orthopedic surgeons then reviewed each pre-planning three times at least one week apart, in a blinded manner. During the reviews, the surgeons modified the pre-plannings until they felt the plannings matched the objectives defined collegially at the beginning of the study. Reliability was assessed using the Intraclass Correlation Coefficient (ICC) and the Standard Error of Measurement (SEM). Results: The intra- and inter-operator reliabilities for implant size selection were almost perfect (ICC between 0.97 and 0.99). Implants of same sizes were selected in 67.1–90.0% of cases. For implant placements, almost perfect intra- and inter-operator reliability was observed in all degrees-of-freedom (ICC between 0.81 and 1.00), except in flexion-extension for the femur (intra-operator ICC between: 0.76 and 0.99; inter-operator ICC of 0.61) and the tibia (intra-operator ICC between 0.12 and 1.00; inter-operator ICC of 0.03). All implant placements SEM were below 1.3 mm or 1.7°. Conclusions: This study showed high intra- and inter-operator reliability for implant size selection and, in most of the degrees-of-freedom, also for implant placements. Further research is needed to evaluate the benefit of developing more precise means of describing the objectives of the surgical planning as well as to evaluate the possibility and relevance of adding features in the planning software to assist the operators.


  • Open Access

    Simultaneous Evaluation of Bone Cut and Implant Placement Accuracy in Robotic-Assisted Total Knee Arthroplasty

    by Killian Cosendey, Julien Stanovici, Hugues Cadas, Patrick Omoumi, Brigitte M. Jolles, Julien Favre

    Background: This study aimed to evaluate the accuracy of bone cuts and implant placements, simultaneously, for total knee arthroplasty (TKA) performed using a system with an active robotic arm. Methods: Two experienced orthopaedic surgeons performed TKA on ten cadaveric legs. Computed tomography scans were performed to compare the bone cuts and implant placements with the preoperative planning. The differences between the planned and actual bone cuts and implant placements were assessed using positional and angular errors in the three anatomical planes. Additionally, the cut–implant deviations were calculated. Statistical analysis was performed to detect systematic errors in the bone cuts and implant placements and to quantify the correlations between these errors. Results: The root-mean-square (RMS) errors of the bone cuts (with respect to the planning) were between 0.7–1.5 mm and 0.6–1.7°. The RMS implant placement errors (with respect to the planning) varied between 0.6–1.6 mm and 0.4–1.5°, except for the femur and tibia in the sagittal plane (2.9°). Systematic errors in the bone cuts and implant placements were observed, respectively, in three and two degrees of freedom. For cut–implant deviations, the RMS values ranged between 0.3–2.0 mm and 0.6–1.9°. The bone cut and implant placement errors were significantly correlated in eight degrees-of-freedom (ρ ≥ 0.67, p < 0.05). Conclusions: With most of the errors below 2 mm or 2°, this study supported the value of active robotic TKA in achieving accurate bone cuts and implant placements. The findings also highlighted the need for both accurate bone cuts and proper implantation technique to achieve accurate implant placements.


  • Open Access

    Ten‐year follow‐up of a total knee prosthesis combining multi‐radius, ultra‐congruency, posterior‐stabilization and mobile‐bearing insert shows long‐lasting clinically relevant improvements in pain, stiffness, function and stability

    by Killian Cosendey, Antoine Eudier, Nicole Fleury, Luis C. Pereira, Julien Favre, Brigitte M. Jolles

    Purpose: There is a paucity of data available on total knee prostheses combining dual‐radius, ultra‐congruency, posterior‐stabilization and mobile‐bearing insert. This prospective cohort study aimed to assess the clinical evolution of the FIRST® prosthesis (Symbios Orthopédie, Yverdon, CH), the earliest prosthesis with this particular design. It was hypothesized that the primary outcomes, evaluating pain, stiffness, function and stability, would improve following arthroplasty and remain improved during the follow‐up period of 10 years.Methods: All patients programmed for a total knee arthroplasty using a FIRST® prosthesis at our university hospital between 2006 and 2008 were invited to participate. Study knees were evaluated pre‐operatively as well as one, five and ten years post‐operatively. Patients filled out questionnaires at each evaluation point and had a radiographic assessment at the five‐year and ten‐year follow‐ups. Primary outcomes were the total, pain, stiffness and function measures of the Western Ontario and McMaster Universities Osteoarthritis questionnaire (WOMAC) and the knee and function measures of the Knee Society Score (KSS). Friedman and Wilcoxon’s rank‐sum tests were used to compare measures across time points.Results: Hundred and twenty four prostheses were included (baseline demographics: 69.9 ± 8.3 years old, 28.1 ± 4.3 kg/m2, 54% male) and 68 could be followed during ten years. Five prostheses underwent a revision. All other prostheses lost at follow‐up were lost for reasons unrelated to the prosthesis. All primary measures reported statistically and clinically significant improvements between baseline and the three follow‐up evaluations. Statistically significant improvements at the three follow‐up evaluations were also observed for most secondary measures. There was no implant loosening. At ten‐year follow‐up, radiolucent lines were observed in 2.9% femoral implants and 1.5% tibial implants.Conclusion: The positive results observed in all domains of assessment and the small revision rate demonstrated an effective functioning of the FIRST® prosthesis during the ten‐year follow‐up period. The results, globally similar to those previously published for other prosthesis designs, encourage the development of assistive methods to select the most appropriate designs on an individual basis.Level of evidence: IV, prospective cohort study.


  • Open Access

    An Expert-Supervised Registration Method for Multiparameter Description of the Knee Joint Using Serial Imaging

    by Hugo Babel, Patrick Omoumi, Killian Cosendey, Julien Stanovici, Hugues Cadas, Brigitte M. Jolles, Julien Favre

    As knee osteoarthritis is a disease of the entire joint, our pathophysiological understanding could be improved by the characterization of the relationships among the knee components. Diverse quantitative parameters can be characterized using magnetic resonance imaging (MRI) and computed tomography (CT). However, a lack of methods for the coordinated measurement of multiple parameters hinders global analyses. This study aimed to design an expert-supervised registration method to facilitate multiparameter description using complementary image sets obtained by serial imaging. The method is based on three-dimensional tissue models positioned in the image sets of interest using manually placed attraction points. Two datasets, with 10 knees CT-scanned twice and 10 knees imaged by CT and MRI were used to assess the method when registering the distal femur and proximal tibia. The median interoperator registration errors, quantified using the mean absolute distance and Dice index, were ≤0.45 mm and ≥0.96 unit, respectively. These values differed by less than 0.1 mm and 0.005 units compared to the errors obtained with gold standard methods. In conclusion, an expert-supervised registration method was introduced. Its capacity to register the distal femur and proximal tibia supports further developments for multiparameter description of healthy and osteoarthritic knee joints, among other applications.


  • Open Access

    Bone Cuts Accuracy of a System for Total Knee Arthroplasty including an Active Robotic Arm

    by Killian Cosendey, Julien Stanovici, Jaad Mahlouly, Patrick Omoumi, Brigitte M. Jolles, Julien Favre

    Introduction: This study aimed to assess the bone cuts accuracy of a system for total knee arthroplasty including an active robotic arm. A second objective was to compare the accuracy among orthopaedic surgeons of different levels of experience. Methods: Three orthopaedic surgeons cut 10 sawbone knees each. Planned and actual bone cuts were compared using computed tomography. Difference with respect to the planning was expressed as three position and three orientation errors following the anatomical planes. Statistical tests were performed to detect bias and compare surgeons. Results: None of the 30 knees presented an outlier error, meaning an error ≥3 mm or ≥3°. The root-mean-square values of the 12 error types were below 0.8 mm or 0.8°, except for the femoral proximal–distal errors (1.7 mm) and the tibial anterior-posterior errors (1.4 mm). Biases were observed, particularly in femoral proximal–distal and tibial anterior–posterior positions. Median differences between surgeons were all lower than 0.8 mm and 0.5°, with statistically significant differences among surgeons in the femoral proximal–distal errors and the tibial anterior–posterior errors. Conclusions: The system tested in this study achieved accurate bone cuts independently of the surgeon’s level of experience. Biases were observed, suggesting that there might be options to improve the accuracy, particularly in proximal–distal position for the femur and in anterior–posterior position for the tibia.


  • Open Access

    Three-Dimensional Quantification of Bone Mineral Density in the Distal Femur and Proximal Tibia Based on Computed Tomography: In Vitro Evaluation of an Extended Standardization Method

    by Hugo Babel, Patrick Omoumi, Killian Cosendey, Hugues Cadas, Brigitte M. Jolles, Julien Favre

    While alterations in bone mineral density (BMD) are of interest in a number of musculoskeletal conditions affecting the knee, their analysis is limited by a lack of tools able to take full advantage of modern imaging modalities. This study introduced a new method, combining computed tomography (CT) and computational anatomy algorithms, to produce standardized three-dimensional BMD quantification in the distal femur and proximal tibia. The method was evaluated on ten cadaveric knees CT-scanned twice and processed following three different experimental settings to assess the influence of different scans and operators. The median reliability (intraclass correlation coefficient (ICC)) ranged from 0.96 to 0.99 and the median reproducibility (precision error (RMSSD)) ranged from 3.97 to 10.75 mg/cc for the different experimental settings. In conclusion, this paper presented a method to standardize three-dimensional knee BMD with excellent reliability and adequate reproducibility to be used in research and clinical applications. The perspectives offered by this novel method are further reinforced by the fact it relies on conventional CT scan of the knee. The standardization method introduced in this work is not limited to BMD and could be adapted to quantify other bone parameters in three dimension based on CT images or images acquired using different modalities.