Rick L. Paul
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rick L. Paul has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
- Richard M. Lindstrom
National Institute of Standards and Technology
5 shared publications - Nicholas Sharp
Material Measurement Laboratory National Institute of Standards and Technology Gaithersburg MD 20899 USA
3 shared publications - Rolf Zeisler
National Institute of Standards and Technology, Gaithersburg, USA
3 shared publications - Bryan E. Tomlin
Analytical Chemistry Division, National Institute of Standards and Technology, Gaithersburg, USA
2 shared publications H. Heather Chen-Mayer
Chemical Sciences Division, National Institute of Standards and Technology, Gaithersburg, USA
2 shared publications- Huaiyu Heather Chen‐Mayer
National Institute of Standards and Technology 20899 Gaithersburg MD USA
2 shared publications
Latest Publications
- 26 June 2025
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 49 (4) , 781-798
A Comparison of Bulk with Micro‐Volume Elemental Values for NIST SRM 610 and NIST SRM 612
NIST SRM 610 and 612 (Trace Elements in Glass) are routinely used for microanalytical measurements but were designed to be bulk‐scale reference materials. This study investigates an approach to quantify the differences between values for elements obtained using the bulk techniques ICP‐OES, INAA and CNPGAA, and values obtained using the predominant microanalytical technique LA‐ICP‐MS. The results from bulk techniques and LA‐ICP‐MS were also compared with currently accepted mass fractions reported in the Certificates of Analysis (CoA) and the literature. The element suite measured was based on the needs of the forensic and geological microanalysis communities, and included B, Ce, Hf, K, La, Li, Ti and Zr. These additional elements are either not included or do not have uncertainty values in the CoAs for NIST SRMs 610 and 612 but are available as community consensus values, which include uncertainties. The measurement results were processed using Monte Carlo (MC) uncertainty analysis for each technique to provide a comprehensive calculation of expanded uncertainties for use in future research. Measurements of mass fractions of the same element both within and between fragments in the LA‐ICP‐MS data were observed to be correlated due to the use of only one calibration material, which was Float Glass Standard (FGS) 2, as that reference material is not directly traceable to NIST SRMs 610 and 612, and is predominantly used in the forensic community. The MC treatment was expected to cause increases in the overall uncertainty values compared with traditional Guide to the Expression of Uncertainty in Measurement (GUM) treatment for all measurements, which was the case for LA‐ICP‐MS measurements of all elements in NIST SRM 610 and NIST SRM 612 (except for Mn in NIST SRM 610). However, for bulk measurements of Ce, Li and Rb in NIST SRM 610, and bulk measurements of Li, Mn, Ti and Zr for NIST SRM 612, the uncertainty decreased due to MC more precisely determining the uncertainty contribution compared with a more conservative approximation from GUM. All results were compared by using E n scores to assess the relative agreement between bulk‐ and micro‐scale measurements, CoA values and to community consensus values. The findings point out the limitations of the current forensic glass reference materials for high precision microanalytical measurements, especially due to the relatively high uncertainty values associated with Float Glass Standard (FGS) 2. This situation underscores the need for new reference materials specifically designed for homogeneity at the micro‐scale for trace element measurement.
- 26 June 2025
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 49 (4) , 781-798
A Comparison of Bulk with Micro‐Volume Elemental Values for NIST SRM 610 and NIST SRM 612
NIST SRM 610 and 612 (Trace Elements in Glass) are routinely used for microanalytical measurements but were designed to be bulk‐scale reference materials. This study investigates an approach to quantify the differences between values for elements obtained using the bulk techniques ICP‐OES, INAA and CNPGAA, and values obtained using the predominant microanalytical technique LA‐ICP‐MS. The results from bulk techniques and LA‐ICP‐MS were also compared with currently accepted mass fractions reported in the Certificates of Analysis (CoA) and the literature. The element suite measured was based on the needs of the forensic and geological microanalysis communities, and included B, Ce, Hf, K, La, Li, Ti and Zr. These additional elements are either not included or do not have uncertainty values in the CoAs for NIST SRMs 610 and 612 but are available as community consensus values, which include uncertainties. The measurement results were processed using Monte Carlo (MC) uncertainty analysis for each technique to provide a comprehensive calculation of expanded uncertainties for use in future research. Measurements of mass fractions of the same element both within and between fragments in the LA‐ICP‐MS data were observed to be correlated due to the use of only one calibration material, which was Float Glass Standard (FGS) 2, as that reference material is not directly traceable to NIST SRMs 610 and 612, and is predominantly used in the forensic community. The MC treatment was expected to cause increases in the overall uncertainty values compared with traditional Guide to the Expression of Uncertainty in Measurement (GUM) treatment for all measurements, which was the case for LA‐ICP‐MS measurements of all elements in NIST SRM 610 and NIST SRM 612 (except for Mn in NIST SRM 610). However, for bulk measurements of Ce, Li and Rb in NIST SRM 610, and bulk measurements of Li, Mn, Ti and Zr for NIST SRM 612, the uncertainty decreased due to MC more precisely determining the uncertainty contribution compared with a more conservative approximation from GUM. All results were compared by using E n scores to assess the relative agreement between bulk‐ and micro‐scale measurements, CoA values and to community consensus values. The findings point out the limitations of the current forensic glass reference materials for high precision microanalytical measurements, especially due to the relatively high uncertainty values associated with Float Glass Standard (FGS) 2. This situation underscores the need for new reference materials specifically designed for homogeneity at the micro‐scale for trace element measurement.
- Open Access
- 27 May 2025
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 334 (7) , 4919-4932
Encoding PGAA spectra as images for material classification with convolutional neural networks
We trained deep convolutional neural networks (CNN) to classify a material based on its prompt gamma ray activation analysis (PGAA) spectrum. We focused on two dimensional (2D) models to leverage abundant open-source models pre-trained on other computer vision tasks for transfer learning. This allows models to be built with a relatively small number of trainable parameters. Moreover, CNNs can be explained naturally using class activation maps and can be equipped with out-of-distribution tests to identify materials which were not present in its training set. Together, these features suggest such models may be excellent candidates for automated material identification in real-world scenarios.
- 27 May 2025
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 334 (7) , 4919-4932
Open AccessEncoding PGAA spectra as images for material classification with convolutional neural networks
We trained deep convolutional neural networks (CNN) to classify a material based on its prompt gamma ray activation analysis (PGAA) spectrum. We focused on two dimensional (2D) models to leverage abundant open-source models pre-trained on other computer vision tasks for transfer learning. This allows models to be built with a relatively small number of trainable parameters. Moreover, CNNs can be explained naturally using class activation maps and can be equipped with out-of-distribution tests to identify materials which were not present in its training set. Together, these features suggest such models may be excellent candidates for automated material identification in real-world scenarios.
- Open Access
- 14 October 2024
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 334 (1) , 689-696
Determination of fluorine in reference materials by chopped-beam cold neutron prompt gamma-ray activation analysis (CB-CNPGAA)
A method is described for determination of fluorine in reference materials by chopped beam cold neutron prompt gamma-ray activation analysis (CB-CNPGAA). The chopper cycle is set to 11 s on/off to match the t 1/2 of 20F. To reduce systematic error, the F mass is measured as the ratio to a comparator element, either Ca or Cl. The F mass fraction is then calculated by multiplying this ratio by the mass fraction of the comparator element. The method is used to measure F in SRMs 1486 Bone Meal, 1400 Bone Ash, 1566a Oyster Tissue, and 2695 Fluorine in Vegetation.
- 14 October 2024
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 334 (1) , 689-696
Open AccessDetermination of fluorine in reference materials by chopped-beam cold neutron prompt gamma-ray activation analysis (CB-CNPGAA)
A method is described for determination of fluorine in reference materials by chopped beam cold neutron prompt gamma-ray activation analysis (CB-CNPGAA). The chopper cycle is set to 11 s on/off to match the t 1/2 of 20F. To reduce systematic error, the F mass is measured as the ratio to a comparator element, either Ca or Cl. The F mass fraction is then calculated by multiplying this ratio by the mass fraction of the comparator element. The method is used to measure F in SRMs 1486 Bone Meal, 1400 Bone Ash, 1566a Oyster Tissue, and 2695 Fluorine in Vegetation.
- 13 July 2024
- Published by Elsevier in Waste Management
- Vol. 187, 91-100
Elemental characterization of electronic waste: a review of research methodologies and applicability to the practice of e-waste recycling
- 13 July 2024
- Published by Elsevier in Waste Management
- Vol. 187, 91-100
Elemental characterization of electronic waste: a review of research methodologies and applicability to the practice of e-waste recycling
- 5 June 2023
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (8) , 3285-3291
Prompt gamma ray activation analysis for determining chemical composition of 3D printing and casting materials used in biomedical applications
Three-dimensional printing and casting materials were analyzed by prompt gamma-ray activation analysis (PGAA) to determine their suitability as human tissue surrogates for the fabrication of phantoms for medical imaging and radiation dosimetry applications. Measured elemental compositions and densities of five surrogate materials simulating soft tissue and bone were used to determine radiological properties (x-ray mass attenuation coefficient and electron stopping power). When compared with radiological properties of International Commission on Radiation Units and Measurements (ICRU) materials, it was determined that urethane rubber and PLA plastic yielded the best match for soft tissue, while silicone rubber and urethane resin best simulated the properties of bone.
- 5 June 2023
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (8) , 3285-3291
Prompt gamma ray activation analysis for determining chemical composition of 3D printing and casting materials used in biomedical applications
Three-dimensional printing and casting materials were analyzed by prompt gamma-ray activation analysis (PGAA) to determine their suitability as human tissue surrogates for the fabrication of phantoms for medical imaging and radiation dosimetry applications. Measured elemental compositions and densities of five surrogate materials simulating soft tissue and bone were used to determine radiological properties (x-ray mass attenuation coefficient and electron stopping power). When compared with radiological properties of International Commission on Radiation Units and Measurements (ICRU) materials, it was determined that urethane rubber and PLA plastic yielded the best match for soft tissue, while silicone rubber and urethane resin best simulated the properties of bone.
- 31 August 2020
- Published by Taylor & Francis in Geomicrobiology Journal
- Vol. 38 (1) , 36-56
Niche Partitioning of Microbial Communities at an Ancient Vitrified Hillfort: Implications for Vitrified Radioactive Waste Disposal
Because microbes cannot be eliminated from radioactive waste disposal facilities, the consequences of bio-colonization must be understood. At a pre-Viking era vitrified hillfort, Broborg, Sweden, anthropogenic glass has been subjected to bio-colonization for over 1,500 years. Broborg is used as a habitat analogue for disposed radioactive waste glass to inform how microbial processes might influence long-term glass durability. Electron microscopy and DNA sequencing of surficial material from the Broborg vitrified wall, adjacent soil, and general topsoil show that the ancient glass supports a niche microbial community of bacteria, fungi, and protists potentially involved in glass alteration. Communities associated with the vitrified wall are distinct and less diverse than soil communities. The vitrified niche of the wall and adjacent soil are dominated by lichens, lichen-associated microbes, and other epilithic, endolithic, and epigeic organisms. These organisms exhibit potential bio-corrosive properties, including silicate dissolution, extraction of essential elements, and secretion of geochemically reactive organic acids, that could be detrimental to glass durability. However, long-term biofilms can also possess a homeostatic function that could limit glass alteration. This study documents potential impacts that microbial colonization and niche partitioning can have on glass alteration, and subsequent release of radionuclides from a disposal facility for vitrified radioactive waste.
- 31 August 2020
- Published by Taylor & Francis in Geomicrobiology Journal
- Vol. 38 (1) , 36-56
Niche Partitioning of Microbial Communities at an Ancient Vitrified Hillfort: Implications for Vitrified Radioactive Waste Disposal
Because microbes cannot be eliminated from radioactive waste disposal facilities, the consequences of bio-colonization must be understood. At a pre-Viking era vitrified hillfort, Broborg, Sweden, anthropogenic glass has been subjected to bio-colonization for over 1,500 years. Broborg is used as a habitat analogue for disposed radioactive waste glass to inform how microbial processes might influence long-term glass durability. Electron microscopy and DNA sequencing of surficial material from the Broborg vitrified wall, adjacent soil, and general topsoil show that the ancient glass supports a niche microbial community of bacteria, fungi, and protists potentially involved in glass alteration. Communities associated with the vitrified wall are distinct and less diverse than soil communities. The vitrified niche of the wall and adjacent soil are dominated by lichens, lichen-associated microbes, and other epilithic, endolithic, and epigeic organisms. These organisms exhibit potential bio-corrosive properties, including silicate dissolution, extraction of essential elements, and secretion of geochemically reactive organic acids, that could be detrimental to glass durability. However, long-term biofilms can also possess a homeostatic function that could limit glass alteration. This study documents potential impacts that microbial colonization and niche partitioning can have on glass alteration, and subsequent release of radionuclides from a disposal facility for vitrified radioactive waste.
- 5 October 2018
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 318 (3) , 2273-2278
Improving accuracy, precision, detection limits, and sample throughput in prompt gamma-ray activation analysis using cold and thermal neutrons and element ratios
- 5 October 2018
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 318 (3) , 2273-2278
Improving accuracy, precision, detection limits, and sample throughput in prompt gamma-ray activation analysis using cold and thermal neutrons and element ratios
- Open Access
- 24 August 2018
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 51 (5) , 1323-1328
Glassy carbon, NIST Standard Reference Material (SRM 3600): hydrogen content, neutron vibrational density of states and heat capacity
Commercial glassy carbon plates being used as absolute intensity calibration standards in small-angle X-ray scattering applications (NIST SRM 3600) have been characterized in several recent publications. This contribution adds to the characterization by measuring the hydrogen content of a plate to be (4.8 ± 0.2) × 10−4 (mol H)/(mol C), and by measuring the vibrational spectrum by neutron inelastic scattering. The spectrum bears a strong resemblance to published measurements on graphite, allowing the identification of several spectral features. The measured spectrum is used to calculate the heat capacity of low-hydrogen-content glassy carbon for comparison with measurements reported here from 20 to 295 K.
- 24 August 2018
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 51 (5) , 1323-1328
Open AccessGlassy carbon, NIST Standard Reference Material (SRM 3600): hydrogen content, neutron vibrational density of states and heat capacity
Commercial glassy carbon plates being used as absolute intensity calibration standards in small-angle X-ray scattering applications (NIST SRM 3600) have been characterized in several recent publications. This contribution adds to the characterization by measuring the hydrogen content of a plate to be (4.8 ± 0.2) × 10−4 (mol H)/(mol C), and by measuring the vibrational spectrum by neutron inelastic scattering. The spectrum bears a strong resemblance to published measurements on graphite, allowing the identification of several spectral features. The measured spectrum is used to calculate the heat capacity of low-hydrogen-content glassy carbon for comparison with measurements reported here from 20 to 295 K.