NSNicholas Sharp

Nicholas Sharp

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nicholas Sharp has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Comparison of Bulk with Micro‐Volume Elemental Values for NIST SRM 610 and NIST SRM 612

    by Nicholas Sharp, Maria Vega Martinez, Ruthmara Corzo, Blaza Toman, Rick Paul, Savelas Rabb, Jack Prothero, Jamie L. Weaver

    NIST SRM 610 and 612 (Trace Elements in Glass) are routinely used for microanalytical measurements but were designed to be bulk‐scale reference materials. This study investigates an approach to quantify the differences between values for elements obtained using the bulk techniques ICP‐OES, INAA and CNPGAA, and values obtained using the predominant microanalytical technique LA‐ICP‐MS. The results from bulk techniques and LA‐ICP‐MS were also compared with currently accepted mass fractions reported in the Certificates of Analysis (CoA) and the literature. The element suite measured was based on the needs of the forensic and geological microanalysis communities, and included B, Ce, Hf, K, La, Li, Ti and Zr. These additional elements are either not included or do not have uncertainty values in the CoAs for NIST SRMs 610 and 612 but are available as community consensus values, which include uncertainties. The measurement results were processed using Monte Carlo (MC) uncertainty analysis for each technique to provide a comprehensive calculation of expanded uncertainties for use in future research. Measurements of mass fractions of the same element both within and between fragments in the LA‐ICP‐MS data were observed to be correlated due to the use of only one calibration material, which was Float Glass Standard (FGS) 2, as that reference material is not directly traceable to NIST SRMs 610 and 612, and is predominantly used in the forensic community. The MC treatment was expected to cause increases in the overall uncertainty values compared with traditional Guide to the Expression of Uncertainty in Measurement (GUM) treatment for all measurements, which was the case for LA‐ICP‐MS measurements of all elements in NIST SRM 610 and NIST SRM 612 (except for Mn in NIST SRM 610). However, for bulk measurements of Ce, Li and Rb in NIST SRM 610, and bulk measurements of Li, Mn, Ti and Zr for NIST SRM 612, the uncertainty decreased due to MC more precisely determining the uncertainty contribution compared with a more conservative approximation from GUM. All results were compared by using E n scores to assess the relative agreement between bulk‐ and micro‐scale measurements, CoA values and to community consensus values. The findings point out the limitations of the current forensic glass reference materials for high precision microanalytical measurements, especially due to the relatively high uncertainty values associated with Float Glass Standard (FGS) 2. This situation underscores the need for new reference materials specifically designed for homogeneity at the micro‐scale for trace element measurement.


  • Certification of Standard Reference Material® 1568c Rice Flour

    by Laura Wood, James Yen, Charles Barber, Monique Johnson, Nicholas Sharp, Maria Isabel Vega Martinez, John Sieber, Colleen Bryan Sallee, Lee Yu, Rick Paul, et al.

    The National Institute of Standards and Technology (NIST) SRM 1568c Rice Flour has value assignments for over 30 analytes, including arsenic species. This material is intended to be used for the evaluation of methods for the determination of elements and arsenic species in this and similar matrices. The material was purchased from commercial vendors. Measurement results were obtained from NIST, National Metrology Institute of Japan (NMIJ), and interlaboratory comparison exercises. This document describes the material, sample preparations, results, and data analysis.

  • Certification of standard reference material® 2693a bituminous coal (nominal mass fraction 0.5 % sulfur)

    by Thomas W Vetter, Colleen E Bryan Sallee, Brian E Lang, Anthony F Marlow, Jennifer M Ness, Rick L Paul, Adam L Pintar, Bruce E Scruggs, Nicholas Sharp, John R Sieber, et al.

  • Combining secondary ion mass spectrometry image depth profiling and single particle inductively coupled plasma mass spectrometry to investigate the uptake and biodistribution of gold nanoparticles in Caenorhabditis elegans

    by Monique E. Johnson, Joe Bennett, Antonio R. Montoro Bustos, Shannon K. Hanna, Andrei Kolmakov, Nicholas Sharp, Elijah J. Petersen, Patricia E. Lapasset, Christopher M. Sims, Karen E. Murphy, et al.


  • Nd and Sm isotopic composition of spent nuclear fuels from three material test reactors

    by Nicholas Sharp, Brian W. Ticknor, Michael Bronikowski, Theodore Nichols, William F. McDonough, Alice Mignerey, Donna Beals


  • Open Access

    Uranium ion yields from monodisperse uranium oxide particles

    by Nicholas Sharp, John D. Fassett, David S. Simons

    Secondary ion mass spectrometry (SIMS) plays an important role in nuclear forensics through its ability to identify isotopic ratios of particles accurately and precisely from samples obtained by inspectors [Boulyga et al., J. Anal. At. Spectrom. 30, 1469 (2015)]. As the particle mass can be on the order of subpicograms, it is important to maximize the sample utilization efficiency of U+ to make high-quality isotopic measurements. The influence of primary ion beam species and polarity on U+ sample utilization efficiency has been previously investigated by Ranebo et al. [J. Anal. At. Spectrom. 24, 277 (2009)]. However, the effect of sample substrate on uranium ion production efficiency and sputtering profile has not been investigated. This work will explore those influences on sample utilization efficiency by analyzing monodisperse uranium oxide microspheres deposited onto graphite and silicon planchets. The particles were mapped using an automated scanning electron microscope, and their coordinates were converted to the SIMS coordinate system using fiducial marks. Results indicate higher U+ sample utilization efficiencies when sputtering with O− and O2− on graphite planchets compared with O2+, whereas O2− gave higher U+ sample utilization efficiencies with silicon wafers compared to O− and O2+. Additionally, during sputtering of uranium particles on silicon wafers with O− and O2−, a sudden drop in U+ signal intensity was observed, which was not present during sputtering with O2+ or any primary ion species for particles on graphite. This drop in U+ signal intensity occurred simultaneously with an increase in UO+ and UO2+ signals, indicating a change in the local matrix around the uranium particle that is unique to silicon compared to graphite.