Reza Noormohammadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Reza Noormohammadi has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Ali Khaleghi
Department of Electronic Systems, Norwegian University of Science and Technology, Trondheim, Norway
4 shared publications Ilangko Balasingham
Department of Electronic Systems, Norwegian University of Science and Technology, Trondheim, Norway
3 shared publications- Ilangko Balasingham
Department of Electronic Systems, Norwegian University of Science and Technology, Trondheim, Norway
1 shared publication - Jacob Bergsland
Intervention Centre, Oslo University Hospital, Oslo, Norway
1 shared publication
Latest Publications
- Open Access
- 22 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 18542-18550
Analog Backscatter Video Transmission for Wireless Capsule Endoscope
Wireless capsule endoscopy is a fast-growing technology in healthcare systems. Due to using battery for powering the camera, light source, wireless communication, and other electronics, it has substantial limitations with the image quality, frame rate, and operating time. In this work, we propose a wireless passive video transmission system for capsule endoscopy, in which the power consumption is reduced by using analog camera sensor, and implementing an innovative radar technique for remote reading of the analog video signal using radio frequency backscattering. The power consumption of the capsule communication system tends to zero. The communication electronics system is minimized to a single Varactor diode with appropriate matching circuits and the image sensor power consumption is reduced by eliminating the camera sensor’s analog to digital converter. With these improvements the capsule system can operate for a longer period of time which enables the feasibility of continuous video streaming during the gastric tract screening. The design feasibility is demonstrated in a phantom experiment, and validated in an animal experiment for depths 6–11 cm using a bi-static radar system at 400 MHz, implemented using software defined radio platform.
- 22 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 18542-18550
Open AccessAnalog Backscatter Video Transmission for Wireless Capsule Endoscope
Wireless capsule endoscopy is a fast-growing technology in healthcare systems. Due to using battery for powering the camera, light source, wireless communication, and other electronics, it has substantial limitations with the image quality, frame rate, and operating time. In this work, we propose a wireless passive video transmission system for capsule endoscopy, in which the power consumption is reduced by using analog camera sensor, and implementing an innovative radar technique for remote reading of the analog video signal using radio frequency backscattering. The power consumption of the capsule communication system tends to zero. The communication electronics system is minimized to a single Varactor diode with appropriate matching circuits and the image sensor power consumption is reduced by eliminating the camera sensor’s analog to digital converter. With these improvements the capsule system can operate for a longer period of time which enables the feasibility of continuous video streaming during the gastric tract screening. The design feasibility is demonstrated in a phantom experiment, and validated in an animal experiment for depths 6–11 cm using a bi-static radar system at 400 MHz, implemented using software defined radio platform.
- 17 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 70 (4) , 2442-2450
Conductive Backscatter Communication for Dual-Chamber Leadless Pacemakers
Dual-chamber and multichamber leadless pacemakers (PMs) are emerging solutions for reducing the limitations of conventional wire-based PMs. One of the main challenges in migrating to leadless PMs is having reliable and low-power data telemetry among the PMs inside the heart chambers. Backscatter communication is a solution for battery-constrained data links and can be applied for the implants using specific designs. In this article, we propose one-way backscatter communication based on conductive coupling for leadless PMs. The implant capsules can communicate with an on-body device without having any active transmitter. The complexity and power consumption are shifted to the remote on-body reader. Dual-chamber PM communication is enabled by using the subcarrier technique for discriminating the devices in the frequency domain. A low data rate of about 11 kb/s is assigned to each PM capsule to communicate its vital information to the reader. The proposed system is designed and realized using off-the-shelf electronic components. The whole system is evaluated in an in vivo experiment. Results indicate the potential of using conductive backscatter for wireless communication in leadless PMs.
- 17 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 70 (4) , 2442-2450
Conductive Backscatter Communication for Dual-Chamber Leadless Pacemakers
Dual-chamber and multichamber leadless pacemakers (PMs) are emerging solutions for reducing the limitations of conventional wire-based PMs. One of the main challenges in migrating to leadless PMs is having reliable and low-power data telemetry among the PMs inside the heart chambers. Backscatter communication is a solution for battery-constrained data links and can be applied for the implants using specific designs. In this article, we propose one-way backscatter communication based on conductive coupling for leadless PMs. The implant capsules can communicate with an on-body device without having any active transmitter. The complexity and power consumption are shifted to the remote on-body reader. Dual-chamber PM communication is enabled by using the subcarrier technique for discriminating the devices in the frequency domain. A low data rate of about 11 kb/s is assigned to each PM capsule to communicate its vital information to the reader. The proposed system is designed and realized using off-the-shelf electronic components. The whole system is evaluated in an in vivo experiment. Results indicate the potential of using conductive backscatter for wireless communication in leadless PMs.
- Open Access
- 8 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 38602-38610
Galvanic Impulse Wireless Communication for Biomedical Implants
Wireless intra-body communication is a promising approach for providing efficient and secure connectivity for medical implants. The low power consumption of the electronics and the conductivity of the biological tissues facilitate the system implementation, which makes the technique more power-efficient than the traditional radio frequency wireless systems. The galvanic intra-body communication uses the electrical current for signal transmission in the conductive medium of the biological tissues. In this paper, we propose an ultra-low-power communication approach by implementing a galvanic impulse method for communication between an implant and an on-body device. The communication system is designed, manufactured with off-the-shelf electronic components, and measured in the phantom and in-vivo animal experiment. The implant power consumption is 45 μW for the data rate of 64 kbps with a bit error percentage below 0.5% for the implant depth of 14 cm. The design supports long-lasting battery-powered implant sensory and communication system.
- 8 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 38602-38610
Open AccessGalvanic Impulse Wireless Communication for Biomedical Implants
Wireless intra-body communication is a promising approach for providing efficient and secure connectivity for medical implants. The low power consumption of the electronics and the conductivity of the biological tissues facilitate the system implementation, which makes the technique more power-efficient than the traditional radio frequency wireless systems. The galvanic intra-body communication uses the electrical current for signal transmission in the conductive medium of the biological tissues. In this paper, we propose an ultra-low-power communication approach by implementing a galvanic impulse method for communication between an implant and an on-body device. The communication system is designed, manufactured with off-the-shelf electronic components, and measured in the phantom and in-vivo animal experiment. The implant power consumption is 45 μW for the data rate of 64 kbps with a bit error percentage below 0.5% for the implant depth of 14 cm. The design supports long-lasting battery-powered implant sensory and communication system.
- 7 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 69 (1) , 443-451
Conductive Impulse for Wireless Communication in Dual-Chamber Leadless Pacemakers
Conductive impulse signaling is proposed for high-efficiency low data-rate wireless communication for future development in cardiac leadless pacemaker technology. The conductivity of the heart muscles and blood is used for electrical signal transmission between two pacemaker implants in the right atrium and the right ventricle. The communication channel is characterized in the frequency range of 1-15 MHz using numerical electromagnetic computations. The wideband implant electrodes support the impulse signaling, and the frequency flat communication channel prevents impulse distortion that simplifies the receiver design using a threshold detector scheme. An ultralow-power impulse generator is designed using off-the-shelf electronics and is integrated into a leadless pacemaker mockup, and the impulse transmission between two capsules is measured in a homogeneous phantom and in vivo animal heart experiments. The feasibility of system integration with the state-of-the-art leadless cardiac pacemakers is demonstrated that can support ultralow-power, low data-rate wireless communications.
- 7 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 69 (1) , 443-451
Conductive Impulse for Wireless Communication in Dual-Chamber Leadless Pacemakers
Conductive impulse signaling is proposed for high-efficiency low data-rate wireless communication for future development in cardiac leadless pacemaker technology. The conductivity of the heart muscles and blood is used for electrical signal transmission between two pacemaker implants in the right atrium and the right ventricle. The communication channel is characterized in the frequency range of 1-15 MHz using numerical electromagnetic computations. The wideband implant electrodes support the impulse signaling, and the frequency flat communication channel prevents impulse distortion that simplifies the receiver design using a threshold detector scheme. An ultralow-power impulse generator is designed using off-the-shelf electronics and is integrated into a leadless pacemaker mockup, and the impulse transmission between two capsules is measured in a homogeneous phantom and in vivo animal heart experiments. The feasibility of system integration with the state-of-the-art leadless cardiac pacemakers is demonstrated that can support ultralow-power, low data-rate wireless communications.