IYIrene Yang

Irene Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Irene Yang has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Biomechanics of the Normal, Fractured, Repaired and Healed Hip Joint: An Introduction

    by Radovan Zdero, Emil H. Schemitsch, Pawel Brzozowski, Irene Yang

    Hip joint fractures can cause significant physical pain, functional loss, and early mortality, thereby reducing a person’s quality and length of life. Although hip fractures can be surgically fixed using implants such as nails, plates, screws, cables, and arthroplasties, postoperative complications can occur, such as infection, nonunion, osteonecrosis, and implant failure. Consequently, it is important to understand the mechanical forces and stresses on the hip during four progressive conditions: (1) normal structure and function; (2) fractured either partially or fully; (3) surgically repaired with an implant; (4) healed sometime after surgery. This information can help biomedical engineers to design better implants, orthopedic surgeons to choose optimal surgical techniques, and rehabilitation therapists to develop beneficial recovery strategies. Therefore, this chapter reviews various representative publications to summarize basic biomechanical concepts and provide numerical data on the forces and stresses experienced by the normal, fractured, repaired, and healed hip, as well as giving suggestions for future directions in research, development, and treatment.

  • Open Access

    Mechanical testing methods for orthopaedic research

    by Radovan Zdero, Pawel Brzozowski, Emil H. Schemitsch, Irene Yang

    Mechanical testing in a controlled laboratory setting is a vital part of orthopaedic research for investigating the structural-level performance or material-level properties of bones, joints, cartilage, soft tissues, and implants. The results can help researchers stay up to date on new findings, medical companies to develop more effective products, and university educators to instruct students on the practical relevance of classroom learning, so that there is a better understanding of orthopaedic conditions and injuries to optimize treatment. This article provides a brief and practical introduction to commonly used state-of-the-art methods, as well as some classic methods which are accurate, easy to use, and inexpensive, to measure different outcomes during in vitro mechanical testing. Planning a mechanical testing study, however, must be done before any experimentation by goal formation, timeline creation, literature review, and so on. Force or torque methods use mechanical testing machines and individual load cells. Displacement or rotation methods include electromagnetic tracking, extensometers or inclinometers, ultrasonic tracking, and videography. Surface strain or stress methods consist of acoustic emission, digital image correlation, fibre optic sensors, strain gauges, and thermography. Interface area or pressure methods encompass Fujifilm, piezoelectric sensors, staining dye, and Tekscan. Interface tribology methods involve the analysis of fretting corrosion friction and wear. Cite this article: Bone Joint Res 2026;15(6):610–616.


  • Open Access

    The design process for orthopaedic implants

    by Radovan Zdero, Pawel Brzozowski, Emil H. Schemitsch, Irene Yang

    Orthopaedic implants consist of engineered devices for various surgical uses, such as plates or nails used to fix fractures; plates, rods, or cages used for spinal fusion, total hip or knee arthroplasties, and osteoconductive bone scaffolds. The implant design process typically involves the complicated interaction of interdisciplinary teams, client consultation, concept generation, concept ranking, prototype fabrication, engineering analysis, etc. However, the process can also be described as having four major aspects, each of which has a feedback loop if modifications are needed. The first is the design and fabrication, which can include factors such as geometry, surface finish, special features, material selection, and methods of fabrication. The second involves mechanical/engineering analysis, which could involve factors such as stress risers, stress shielding, elastic stiffness, failure strength, and fatigue life. The third is biological/clinical analysis, which may involve factors such as biocompatibility, bioresorbability, bone remodelling, surgical simplicity, and clinical outcomes. The fourth is marketplace evaluation, which might involve factors such as cost-effectiveness, patent acquisition, regulatory approval, demographic suitability, and ecological sustainability. These aspects, or the specific factors within each aspect, can occur sequentially step by step, simultaneously side by side, in different orders, or by some combination of all of these options. This article is a brief practical introduction to the design process for orthopaedic implants. Cite this article: Bone Joint Res 2026;15(5):577–582.


  • Open Access

    Ultrasonic tool to cut human bone: Cutting speed and forces necessary for potential remote robotic arms

    by Irene Yang, Russell Buchanan, Nisreen Al-Namnam, Xuan Li, Margaret Lucas, A. Hamish R. W. Simpson

    Procedural-related musculoskeletal pain is common among orthopaedic surgeons, often caused by the repetitive use of high-force bone-cutting tools. Ultrasonic cutting devices, which can operate with lower force, may help reduce this physical burden. In this study, three practising orthopaedic surgeons each performed two cuts on three fresh cortical bone samples, harvested from excised femoral necks from three patients undergoing hip replacement surgery. The study was conducted using an ultrasonic cutting device in a controlled yet clinically reflective environment. A novel setup captured real-time data on surgeon-related parameters, including vertical cutting force and vertical and horizontal cutting speed. Consistent with previous research, we confirmed that ultrasonic devices enable low force cutting (average 1.91 N). However, our findings revealed significant variability in how each surgeon interacted with the device – including how much force each surgeon applied, and how the device was manoeuvred which can influence device performance, thermal effects, and overall clinical outcomes. Given the critical importance of surgeon-related factors, our results highlight the need to understand how each surgeon interacts with these devices differently. This insight can inform training and device optimisation strategies; help translate bench testing results into effective clinical use and ultimately improve surgical performance and patient outcomes. Additionally, our findings support the potential benefits of integrating ultrasonic devices with robotic platforms to maintain consistent cutting parameters. Future research should investigate optimal cutting parameters, evaluate different blade profiles, assess result generalisability and compare outcomes before and after training or system enhancements.

  • Open Access

    Overcoming barriers to interdisciplinary research in engineering and orthopaedic surgery

    by Irene Yang, Shao-Ting Jerry Tsang, Simon G. F. Abram, Chloe E. H. Scott, A. Hamish R. W. Simpson

    Overcoming barriers to interdisciplinary research in engineering and orthopaedic surgery


  • Open Access

    The Lived Fracture Experience (LiFE) study: A mixed methods qualitative study research protocol exploring the lived experiences of fracture non-union patients

    by Irene Yang, Carol Porteous, Hamish Simpson

    Background: Fractures are a common and a major cause of disability and death, with up to 10% of fractures failing to heal normally. These fractures are called “fracture non-unions”. Currently, debate on the impact of non-union in the medical and research communities exists. Unfortunately, this indirectly minimizes the impact of fracture non-unions, and hinders further research work which could reduce unnecessary patient suffering. In this study, we aim to explore the lived experiences of fracture non-union patients in one-on-one interviews to determine whether fracture non-union is a burden for patients, and if so, to outline the burden on patients and their close circles. Methods: Eligible participants will include adult patients who currently have/previously (in the last 36 months) had a long bone fracture that has not healed normally. Data will be collected through in-depth face-to-face or telephone interviews, complemented by quantitative data captured using the standardized Euroqol EQ-5D-5L questionnaire. With consent, interviews will be audio-recorded and transcribed verbatim. Using NVIVO software, we will develop grouped codes and categories to describe and provide insight into the experience of fracture non-union patients. EQ-5D-5L, and EQ VAS data will be presented using a measure of central tendency and a measure of dispersion to provide insight into the overall health related quality of life for patients. Ethics and dissemination: The study was approved by the Health Research Authority and Health and Care Research Wales Approval (approval date: 27 March 2024; IRAS project ID: 337652). Results from this study aim to improve the information and support provided to fracture non-union patients. Findings will be disseminated to the study participants, healthcare professionals, and local commissioners through peer-reviewed articles and at academic conferences.


  • Open Access

    Mechanisms of mobile bearing dislocation in lateral unicompartmental knee replacement

    by Irene Yang, Greta Agustoni, David W Murray, Stephen J Mellon

    Mobile bearing dislocation occurs in 1– 6% of Oxford Domed Lateral replacements. Dislocations are predominantly medial, but can occur anteriorly or posteriorly. They tend to occur when the knee is flexed. It is not clear how dislocations can be prevented. A previously described mechanical rig for assessing mobile bearing dislocation was updated so as to study dislocation with the knee in flexion. Sub-categories for the description of each type of dislocation were introduced. Dislocation was only possible when the knee was distracted. As the amount of distraction possible in the knee is variable, the risk of dislocation is related to the amount of distraction in the rig necessary for a dislocation. The type of dislocation requiring the least distraction was medial `edge' dislocation in which the edge of the bearing dislocates onto the tibial wall, which is the most common type of dislocation. The amount of distraction necessary decreased the further the bearing was from the wall and with 50% posterior overhang. Rotation of the knee did not influence the amount of distraction. In conclusion dislocation can only occur if the lateral compartment is distracted. To reduce the dislocation risk, surgeons should aim to position the femoral and tibial components so that the bearing is as close as possible to the wall without jamming against it and the tibial component should be positioned flush with the posterior tibial cortex. If, during the surgery, the mobile bearing can easily be dislocated onto the wall the surgeon should consider changing to a fixed bearing. The tibial component should also be positioned flush with the posterior tibial cortex, as if it is too far forward this may contribute to dislocation.


  • Open Access

    Application of a robotics path planning algorithm to assess the risk of mobile bearing dislocation in lateral unicompartmental knee replacement

    by Irene Yang, Jonathan D. Gammell, David W. Murray, Stephen J. Mellon

    Due to ligament laxity, bearing dislocation occurs in 1–6% of Oxford Domed Lateral (ODL) replacements with most dislocations occurring medially. Dislocations were studied using a previously built mechanical rig, however testing using the rig was inefficient. The aim of this study was to develop a better tool that was more reliable and efficient. An established robotics software package, the Open Motion Planning Library, was modified to accept the ODL components. Using a robotics path planning algorithm, the mobile bearing was allowed to find a way out from between the femoral and tibial components i.e. to dislocate. Testing assessed a range of clinically relevant positions of the femoral component relative to the tibial component. Dislocations were labelled as medial, lateral, anterior or posterior depending on the dislocation direction. The Distraction to Dislocation (DD) measured the minimum vertical distraction of the femoral component from the tibial component for a dislocation to occur. Results were validated against the mechanical rig. Statistical analysis of medial dislocation showed excellent agreement with an intraclass correlation value of 0.993 (95% CI 0.982–0.998). All DDs from the dislocation analysis tool were within 1 mm of the mechanical rig DDs with results sharing a remarkably similar trend. The robotics dislocation analysis tool output DDs which were marginally higher than the manual mechanical rig: 0.50 mm anteriorly, 0.25 mm posteriorly and 0.50 mm laterally. Medially, the computational DD differed on average by 0.09 mm (stand deviation: 0.2026 mm). Our study describes the development and validation of a novel robotics dislocation analysis tool, which allows mobile bearing dislocation risk quantification. The tool may also be used to improve surgical implantation parameters and to assess new implant designs that aim to reduce the medial dislocation risk to an acceptable level.