Pawel Brzozowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Pawel Brzozowski has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Emil Schemitsch
Victoria Hospital, London Health Sciences Centre Research Institute, London, Canada
14 shared publications - Radovan Zdero
Victoria Hospital, London Health Sciences Centre Research Institute, London, Canada
14 shared publications Radovan Zdero
London Health Sciences Centre Research Institute , London, ON N6A 5W9, Canada
7 shared publicationsEmil H. Schemitsch
London Health Sciences Centre Research Institute , London, ON N6A 5W9, Canada ; , London, ON N6A 3K7, Canada
5 shared publications- Aaron Gee
Orthopaedic Biomechanics Lab, Victoria Hospital, London, Canada
3 shared publications - Irene Yang
Victoria Hospital, London Health Sciences Centre Research Institute, London, Canada
3 shared publications
Latest Publications
- Open Access
- 12 October 2026
- Published by IntechOpen
Biomechanics of the Normal, Fractured, Repaired and Healed Hip Joint: An Introduction
Hip joint fractures can cause significant physical pain, functional loss, and early mortality, thereby reducing a person’s quality and length of life. Although hip fractures can be surgically fixed using implants such as nails, plates, screws, cables, and arthroplasties, postoperative complications can occur, such as infection, nonunion, osteonecrosis, and implant failure. Consequently, it is important to understand the mechanical forces and stresses on the hip during four progressive conditions: (1) normal structure and function; (2) fractured either partially or fully; (3) surgically repaired with an implant; (4) healed sometime after surgery. This information can help biomedical engineers to design better implants, orthopedic surgeons to choose optimal surgical techniques, and rehabilitation therapists to develop beneficial recovery strategies. Therefore, this chapter reviews various representative publications to summarize basic biomechanical concepts and provide numerical data on the forces and stresses experienced by the normal, fractured, repaired, and healed hip, as well as giving suggestions for future directions in research, development, and treatment.
- 12 October 2026
- Published by IntechOpen
Open AccessBiomechanics of the Normal, Fractured, Repaired and Healed Hip Joint: An Introduction
Hip joint fractures can cause significant physical pain, functional loss, and early mortality, thereby reducing a person’s quality and length of life. Although hip fractures can be surgically fixed using implants such as nails, plates, screws, cables, and arthroplasties, postoperative complications can occur, such as infection, nonunion, osteonecrosis, and implant failure. Consequently, it is important to understand the mechanical forces and stresses on the hip during four progressive conditions: (1) normal structure and function; (2) fractured either partially or fully; (3) surgically repaired with an implant; (4) healed sometime after surgery. This information can help biomedical engineers to design better implants, orthopedic surgeons to choose optimal surgical techniques, and rehabilitation therapists to develop beneficial recovery strategies. Therefore, this chapter reviews various representative publications to summarize basic biomechanical concepts and provide numerical data on the forces and stresses experienced by the normal, fractured, repaired, and healed hip, as well as giving suggestions for future directions in research, development, and treatment.
- Open Access
- 2 June 2026
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 15 (6) , 610-616
Mechanical testing methods for orthopaedic research
Mechanical testing in a controlled laboratory setting is a vital part of orthopaedic research for investigating the structural-level performance or material-level properties of bones, joints, cartilage, soft tissues, and implants. The results can help researchers stay up to date on new findings, medical companies to develop more effective products, and university educators to instruct students on the practical relevance of classroom learning, so that there is a better understanding of orthopaedic conditions and injuries to optimize treatment. This article provides a brief and practical introduction to commonly used state-of-the-art methods, as well as some classic methods which are accurate, easy to use, and inexpensive, to measure different outcomes during in vitro mechanical testing. Planning a mechanical testing study, however, must be done before any experimentation by goal formation, timeline creation, literature review, and so on. Force or torque methods use mechanical testing machines and individual load cells. Displacement or rotation methods include electromagnetic tracking, extensometers or inclinometers, ultrasonic tracking, and videography. Surface strain or stress methods consist of acoustic emission, digital image correlation, fibre optic sensors, strain gauges, and thermography. Interface area or pressure methods encompass Fujifilm, piezoelectric sensors, staining dye, and Tekscan. Interface tribology methods involve the analysis of fretting corrosion friction and wear. Cite this article: Bone Joint Res 2026;15(6):610–616.
- 2 June 2026
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 15 (6) , 610-616
Open AccessMechanical testing methods for orthopaedic research
Mechanical testing in a controlled laboratory setting is a vital part of orthopaedic research for investigating the structural-level performance or material-level properties of bones, joints, cartilage, soft tissues, and implants. The results can help researchers stay up to date on new findings, medical companies to develop more effective products, and university educators to instruct students on the practical relevance of classroom learning, so that there is a better understanding of orthopaedic conditions and injuries to optimize treatment. This article provides a brief and practical introduction to commonly used state-of-the-art methods, as well as some classic methods which are accurate, easy to use, and inexpensive, to measure different outcomes during in vitro mechanical testing. Planning a mechanical testing study, however, must be done before any experimentation by goal formation, timeline creation, literature review, and so on. Force or torque methods use mechanical testing machines and individual load cells. Displacement or rotation methods include electromagnetic tracking, extensometers or inclinometers, ultrasonic tracking, and videography. Surface strain or stress methods consist of acoustic emission, digital image correlation, fibre optic sensors, strain gauges, and thermography. Interface area or pressure methods encompass Fujifilm, piezoelectric sensors, staining dye, and Tekscan. Interface tribology methods involve the analysis of fretting corrosion friction and wear. Cite this article: Bone Joint Res 2026;15(6):610–616.
- Open Access
- 27 May 2026
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 15 (5) , 577-582
The design process for orthopaedic implants
Orthopaedic implants consist of engineered devices for various surgical uses, such as plates or nails used to fix fractures; plates, rods, or cages used for spinal fusion, total hip or knee arthroplasties, and osteoconductive bone scaffolds. The implant design process typically involves the complicated interaction of interdisciplinary teams, client consultation, concept generation, concept ranking, prototype fabrication, engineering analysis, etc. However, the process can also be described as having four major aspects, each of which has a feedback loop if modifications are needed. The first is the design and fabrication, which can include factors such as geometry, surface finish, special features, material selection, and methods of fabrication. The second involves mechanical/engineering analysis, which could involve factors such as stress risers, stress shielding, elastic stiffness, failure strength, and fatigue life. The third is biological/clinical analysis, which may involve factors such as biocompatibility, bioresorbability, bone remodelling, surgical simplicity, and clinical outcomes. The fourth is marketplace evaluation, which might involve factors such as cost-effectiveness, patent acquisition, regulatory approval, demographic suitability, and ecological sustainability. These aspects, or the specific factors within each aspect, can occur sequentially step by step, simultaneously side by side, in different orders, or by some combination of all of these options. This article is a brief practical introduction to the design process for orthopaedic implants. Cite this article: Bone Joint Res 2026;15(5):577–582.
- 27 May 2026
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 15 (5) , 577-582
Open AccessThe design process for orthopaedic implants
Orthopaedic implants consist of engineered devices for various surgical uses, such as plates or nails used to fix fractures; plates, rods, or cages used for spinal fusion, total hip or knee arthroplasties, and osteoconductive bone scaffolds. The implant design process typically involves the complicated interaction of interdisciplinary teams, client consultation, concept generation, concept ranking, prototype fabrication, engineering analysis, etc. However, the process can also be described as having four major aspects, each of which has a feedback loop if modifications are needed. The first is the design and fabrication, which can include factors such as geometry, surface finish, special features, material selection, and methods of fabrication. The second involves mechanical/engineering analysis, which could involve factors such as stress risers, stress shielding, elastic stiffness, failure strength, and fatigue life. The third is biological/clinical analysis, which may involve factors such as biocompatibility, bioresorbability, bone remodelling, surgical simplicity, and clinical outcomes. The fourth is marketplace evaluation, which might involve factors such as cost-effectiveness, patent acquisition, regulatory approval, demographic suitability, and ecological sustainability. These aspects, or the specific factors within each aspect, can occur sequentially step by step, simultaneously side by side, in different orders, or by some combination of all of these options. This article is a brief practical introduction to the design process for orthopaedic implants. Cite this article: Bone Joint Res 2026;15(5):577–582.
- Open Access
- 1 January 2026
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 18 (1) , 1-18
Mechanical Performance of Monoaxial Versus Polyaxial Locked Plates for Bone Fracture Repair: A Review
Zdero R, et al. Clin Orthop Surg. 2026 Feb;18(1):1-18. https://doi.org/10.4055/cios24492
- 1 January 2026
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 18 (1) , 1-18
Open AccessMechanical Performance of Monoaxial Versus Polyaxial Locked Plates for Bone Fracture Repair: A Review
Zdero R, et al. Clin Orthop Surg. 2026 Feb;18(1):1-18. https://doi.org/10.4055/cios24492
- 8 December 2025
- Published by ASME International in Journal of Medical Devices
- Vol. 20 (1)
Mechanical Properties and Engineering Analysis of Intramedullary Bone Fixation Nails Made From Fiber-Reinforced Composites: A Review
Intramedullary nails (i.e., cylindrical or noncylindrical rods) for bone fracture fixation are manufactured using titanium or steel, which are stiffer compared to bone. Yet, stiff metal nails can limit interfragmentary fracture motion, which potentially causes delayed callus formation and healing. Also, stiff metal nails may carry too much load relative to bone, which potentially causes bone “stress shielding” adjacent to the nail, bone density loss, bone resorption, and nail loosening. As such, there have been previous attempts to develop flexible nails using nonmetallic materials made from fibers (e.g., carbon, flax, glass) immersed in polymer resins (e.g., epoxy, polyether-ether-ketone, polylactic acid). The goal of prior research has been to produce composite nails with tailor-made mechanical properties and optimal engineering performance versus traditional metal nails. Therefore, this is the first review to survey 40 years of previous literature on composite nails that reported mechanical properties of fibers and resins at the material level (e.g., elastic modulus, ultimate strength), mechanical properties of isolated composite nails at the material level (e.g., fatigue strength, surface hardness), and bone-nail engineering performance (e.g., fracture motion, nail stress). Moreover, applying design principles, improving study protocols, performing future research, and clinical considerations are also discussed to help future researchers to develop intramedullary nails from novel materials.
- 8 December 2025
- Published by ASME International in Journal of Medical Devices
- Vol. 20 (1)
Mechanical Properties and Engineering Analysis of Intramedullary Bone Fixation Nails Made From Fiber-Reinforced Composites: A Review
Intramedullary nails (i.e., cylindrical or noncylindrical rods) for bone fracture fixation are manufactured using titanium or steel, which are stiffer compared to bone. Yet, stiff metal nails can limit interfragmentary fracture motion, which potentially causes delayed callus formation and healing. Also, stiff metal nails may carry too much load relative to bone, which potentially causes bone “stress shielding” adjacent to the nail, bone density loss, bone resorption, and nail loosening. As such, there have been previous attempts to develop flexible nails using nonmetallic materials made from fibers (e.g., carbon, flax, glass) immersed in polymer resins (e.g., epoxy, polyether-ether-ketone, polylactic acid). The goal of prior research has been to produce composite nails with tailor-made mechanical properties and optimal engineering performance versus traditional metal nails. Therefore, this is the first review to survey 40 years of previous literature on composite nails that reported mechanical properties of fibers and resins at the material level (e.g., elastic modulus, ultimate strength), mechanical properties of isolated composite nails at the material level (e.g., fatigue strength, surface hardness), and bone-nail engineering performance (e.g., fracture motion, nail stress). Moreover, applying design principles, improving study protocols, performing future research, and clinical considerations are also discussed to help future researchers to develop intramedullary nails from novel materials.
- 1 September 2025
- Published by ASME International in Journal of Biomechanical Engineering
- p. 1-24
Computational Modeling and Mechanical Testing of Calcaneus Fracture Plates: A Review
This review article surveys all computational and experimental investigations that varied plate and/or screw variables to evaluate the mechanical effect on calcaneus (i.e., heel bone) fracture plates (CFPs). PubMed, Scopus, and Web of Science archives were examined for studies published on any date and in any language that (i) mechanically characterized the effect of changing plate and/or screw variables on CFP performance, rather than just comparing or augmenting CFPs with other types of implants and (ii) only analyzed calcaneus fractures, rather than other co-injuries of the ankle or foot. The 36 eligible studies evaluated various plate variables (i.e., geometry, hole type, number) and screw variables (i.e., geometry, number, distribution, angle), but not plate position or material. The studies reported engineering outcome metrics like (i) interfragmentary motion (0-11.24 mm; 0-1.20 deg), (ii) bone (2.6-502.6 MPa), plate (11.4-1084.0 MPa), or screw (19.7-524.5 MPa) stress, (iii) bone stress under the plate to evaluate ?stress shielding? (0-50.0 MPa), (iv) the number of loading cycles to failure (1000-89250 cycles), (v) overall stiffness (22-5108 N/mm), or (vi) failure strength (100-7867 N). This review also discusses future work for implant variables, bone variables, study methodologies, and clinical items, as well as recommending a particular CFP configuration for maximal mechanical stability. This review will help biomedical engineers and orthopaedic surgeons to effectively design, analyze, or use CFPs.
- 1 September 2025
- Published by ASME International in Journal of Biomechanical Engineering
- p. 1-24
Computational Modeling and Mechanical Testing of Calcaneus Fracture Plates: A Review
This review article surveys all computational and experimental investigations that varied plate and/or screw variables to evaluate the mechanical effect on calcaneus (i.e., heel bone) fracture plates (CFPs). PubMed, Scopus, and Web of Science archives were examined for studies published on any date and in any language that (i) mechanically characterized the effect of changing plate and/or screw variables on CFP performance, rather than just comparing or augmenting CFPs with other types of implants and (ii) only analyzed calcaneus fractures, rather than other co-injuries of the ankle or foot. The 36 eligible studies evaluated various plate variables (i.e., geometry, hole type, number) and screw variables (i.e., geometry, number, distribution, angle), but not plate position or material. The studies reported engineering outcome metrics like (i) interfragmentary motion (0-11.24 mm; 0-1.20 deg), (ii) bone (2.6-502.6 MPa), plate (11.4-1084.0 MPa), or screw (19.7-524.5 MPa) stress, (iii) bone stress under the plate to evaluate ?stress shielding? (0-50.0 MPa), (iv) the number of loading cycles to failure (1000-89250 cycles), (v) overall stiffness (22-5108 N/mm), or (vi) failure strength (100-7867 N). This review also discusses future work for implant variables, bone variables, study methodologies, and clinical items, as well as recommending a particular CFP configuration for maximal mechanical stability. This review will help biomedical engineers and orthopaedic surgeons to effectively design, analyze, or use CFPs.
- Open Access
- 15 July 2025
- Published by Elsevier in Chinese Journal of Traumatology
- Vol. 29 (2) , 106-117
Biomechanical performance of proximal tibia fracture plates: A review
- 15 July 2025
- Published by Elsevier in Chinese Journal of Traumatology
- Vol. 29 (2) , 106-117
Open AccessBiomechanical performance of proximal tibia fracture plates: A review
- Open Access
- 1 January 2025
- Published by Wiley in BioMed Research International
- Vol. 2025 (1) , 6313005
Biomechanical Analysis of Ankle Stability Following Deltoid Ligament Repair and Reconstruction
Background: The deltoid ligament has been shown to contribute to the stability of the ankle mortise, preventing valgus talar tilt, external rotation (ER), and translation. Research to date assessing the appropriateness of deltoid repair to reintroduce medial stability to a fractured ankle is unclear. Deltoid ligament reconstruction using autograft or allograft has been proposed in cases of chronic deltoid insufficiency. This biomechanical study sought to assess the stability offered by deltoid repair and reconstruction compared to the native deltoid ligament in its intact and defunctioned states. Materials and Methods: Twelve (six pairs) fresh frozen cadaveric lower extremities with intact deltoid ligaments underwent biomechanical assessment in a custom‐made multiaxial testing apparatus. Each specimen was tested in plantarflexion/dorsiflexion (PF/DF), inversion/eversion (IV/EV), and internal rotation (IR)/ER and analyzed for angular range of motion (ROM) and stiffness. The specimens were tested with an intact deltoid ligament and following disruption via transection. Subsequently, paired specimens were randomized to either deltoid repair or reconstruction. A single double‐loaded suture anchor was used to repair the deep and superficial deltoid ligaments. The tibialis anterior tendon was used as an autograft in the reconstruction group. Results: Normalized ROM and stiffness were significantly different in deficient specimens compared to all other groups during PF/DF. During IR/ER, the deficient ankle was significantly different from the intact and repair state. For IV/EV, deficient specimen ROM was significantly greater than the intact or repair states, while the stiffness for the deficient ankles was significantly less. Conclusion: Deltoid repair and reconstruction were comparable in returning the ankles to an intact state and conferring stability. These results suggest that in cases with insufficient or unstable deltoid ligament where repair is not possible, reconstruction has the potential to be a reliable alternative, but further studies are warranted to understand all advantages/disadvantages.
- 1 January 2025
- Published by Wiley in BioMed Research International
- Vol. 2025 (1) , 6313005
Open AccessBiomechanical Analysis of Ankle Stability Following Deltoid Ligament Repair and Reconstruction
Background: The deltoid ligament has been shown to contribute to the stability of the ankle mortise, preventing valgus talar tilt, external rotation (ER), and translation. Research to date assessing the appropriateness of deltoid repair to reintroduce medial stability to a fractured ankle is unclear. Deltoid ligament reconstruction using autograft or allograft has been proposed in cases of chronic deltoid insufficiency. This biomechanical study sought to assess the stability offered by deltoid repair and reconstruction compared to the native deltoid ligament in its intact and defunctioned states. Materials and Methods: Twelve (six pairs) fresh frozen cadaveric lower extremities with intact deltoid ligaments underwent biomechanical assessment in a custom‐made multiaxial testing apparatus. Each specimen was tested in plantarflexion/dorsiflexion (PF/DF), inversion/eversion (IV/EV), and internal rotation (IR)/ER and analyzed for angular range of motion (ROM) and stiffness. The specimens were tested with an intact deltoid ligament and following disruption via transection. Subsequently, paired specimens were randomized to either deltoid repair or reconstruction. A single double‐loaded suture anchor was used to repair the deep and superficial deltoid ligaments. The tibialis anterior tendon was used as an autograft in the reconstruction group. Results: Normalized ROM and stiffness were significantly different in deficient specimens compared to all other groups during PF/DF. During IR/ER, the deficient ankle was significantly different from the intact and repair state. For IV/EV, deficient specimen ROM was significantly greater than the intact or repair states, while the stiffness for the deficient ankles was significantly less. Conclusion: Deltoid repair and reconstruction were comparable in returning the ankles to an intact state and conferring stability. These results suggest that in cases with insufficient or unstable deltoid ligament where repair is not possible, reconstruction has the potential to be a reliable alternative, but further studies are warranted to understand all advantages/disadvantages.
- 19 August 2024
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 10 (9) , 5439-5453
Material Properties and Engineering Performance of Bone Fracture Plates Made from Plant Fiber Reinforced Composites: A Review
Bone fracture plates are usually made from titanium alloy or stainless steel, which are much stiffer than bone. However, overly stiff plates can restrict axial interfragmentary motion at the fracture leading to delayed callus formation and healing, as well as causing bone "stress shielding" under the plate leading to bone atrophy, bone resorption, and plate loosening. Consequently, there have been many prior efforts to develop nonmetallic bone fracture plates with customized material properties using synthetic fibers (e.g., aramid, carbon, glass) in polymer resin. Even so, plant fibers (e.g., flax, roselle, sisal) offer additional advantages over synthetic fibers, such as availability, biodegradability, less toxicity during processing, lower financial cost, and recyclability. As such, there is an emerging interest in using plant fibers alone, or combined with synthetic fibers, to reinforce polymers for various applications. Thus, this is the first review article on the material properties and engineering performance of innovative bone fracture plates made from composite materials reinforced by plant fibers alone or supplemented using synthetic fibers. This article presents material-level fiber properties (e.g., elastic modulus, ultimate strength), material-level plate properties (e.g., fatigue strength, impact toughness), and bone-plate engineering performance (e.g., overall stiffness, plate stress), as well as discussing general findings, study quality, and future work. This article may help engineers and surgeons to design, fabricate, analyze, and utilize novel bone fracture plates.
- 19 August 2024
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 10 (9) , 5439-5453
Material Properties and Engineering Performance of Bone Fracture Plates Made from Plant Fiber Reinforced Composites: A Review
Bone fracture plates are usually made from titanium alloy or stainless steel, which are much stiffer than bone. However, overly stiff plates can restrict axial interfragmentary motion at the fracture leading to delayed callus formation and healing, as well as causing bone "stress shielding" under the plate leading to bone atrophy, bone resorption, and plate loosening. Consequently, there have been many prior efforts to develop nonmetallic bone fracture plates with customized material properties using synthetic fibers (e.g., aramid, carbon, glass) in polymer resin. Even so, plant fibers (e.g., flax, roselle, sisal) offer additional advantages over synthetic fibers, such as availability, biodegradability, less toxicity during processing, lower financial cost, and recyclability. As such, there is an emerging interest in using plant fibers alone, or combined with synthetic fibers, to reinforce polymers for various applications. Thus, this is the first review article on the material properties and engineering performance of innovative bone fracture plates made from composite materials reinforced by plant fibers alone or supplemented using synthetic fibers. This article presents material-level fiber properties (e.g., elastic modulus, ultimate strength), material-level plate properties (e.g., fatigue strength, impact toughness), and bone-plate engineering performance (e.g., overall stiffness, plate stress), as well as discussing general findings, study quality, and future work. This article may help engineers and surgeons to design, fabricate, analyze, and utilize novel bone fracture plates.