Caiyun Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Caiyun Ma has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Chengyu Liu
State Key Laboratory of Digital Medical Engineering, School of Instrument Science and Engineering, Southeast University, Nanjing, China
14 shared publications - Jianqing Li
School of Instrument Science and Engineering, Southeast University, Nanjing, China
11 shared publications - Chenxi Yang
State Key Laboratory of Digital Medical Engineering, School of Instrument Science and Engineering, Southeast University, Nanjing, China
4 shared publications - Zhijun Xiao
State Key Laboratory of Bioelectronics, School of Instrument Science and Engineering, Southeast University, Nanjing, China
4 shared publications - Lina Zhao
The State Key Laboratory of Bioelectronics, School of Instrument Science and Engineering, Southeast University, Nanjing 210096, China
3 shared publications - Weijie Sheng
School of Information Engineering, Yangzhou University, Yangzhou, China
3 shared publications
Latest Publications
- 30 April 2026
- Published by Elsevier in Expert Systems with Applications
- Vol. 326
Multi-task learning with signal denoising and self-distilled representations for wearable ECG arrhythmia detection
- 30 April 2026
- Published by Elsevier in Expert Systems with Applications
- Vol. 326
Multi-task learning with signal denoising and self-distilled representations for wearable ECG arrhythmia detection
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
An Atrial Fibrillation Detection Strategy Based on Self-Supervised Pretraining in Wearable ECG Monitoring
Atrial fibrillation (AF) is an insidious cardiac arrhythmia, with its incidence increasing annually. Timely screening and home-based interventions play a vital role in the effective management of atrial fibrillation (AF). Within the Internet of Medical Things (IoMT) landscape, wearable electrocardiogram (ECG) monitoring devices have been seamlessly integrated to monitor AF. Nonetheless, the substantial influx of ECG signals awaiting annotation and the exorbitant costs associated with employing specialists for manual annotation pose significant hurdles in the development of AF detection systems. Despite the potential utilization of AF detectors trained on open databases, their efficacy in analyzing continuous wearable ECGs remains inadequate. Self-supervised representation learning proficiently characterizes unlabeled data and enhances data utilization without labels. This study proposes an AF detection strategy based on self-supervised pre-training, aiming for optimal AF detection performance with minimal annotation costs. The proposed method employed self-supervised representation learning and pre-training strategy and was validated on four datasets from the 4th China Physiological Signal Challenge (CPSC2021) database, achieving accuracies of 98.13%, 90.11%, 92.63%, and 91.29%. Additionally, validation on 20 wearable ECG recordings yielded mean accuracies of 99.38% and 99.48% for AF and Non-AF on unlabeled data from recordings used for fine-tuning. We achieved mean accuracies of 97.19% and 94.15% for AF and Non-AF on independent recordings. The results demonstrate the proposed method’s reliability for AF detection in wearable ECG monitoring.
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
An Atrial Fibrillation Detection Strategy Based on Self-Supervised Pretraining in Wearable ECG Monitoring
Atrial fibrillation (AF) is an insidious cardiac arrhythmia, with its incidence increasing annually. Timely screening and home-based interventions play a vital role in the effective management of atrial fibrillation (AF). Within the Internet of Medical Things (IoMT) landscape, wearable electrocardiogram (ECG) monitoring devices have been seamlessly integrated to monitor AF. Nonetheless, the substantial influx of ECG signals awaiting annotation and the exorbitant costs associated with employing specialists for manual annotation pose significant hurdles in the development of AF detection systems. Despite the potential utilization of AF detectors trained on open databases, their efficacy in analyzing continuous wearable ECGs remains inadequate. Self-supervised representation learning proficiently characterizes unlabeled data and enhances data utilization without labels. This study proposes an AF detection strategy based on self-supervised pre-training, aiming for optimal AF detection performance with minimal annotation costs. The proposed method employed self-supervised representation learning and pre-training strategy and was validated on four datasets from the 4th China Physiological Signal Challenge (CPSC2021) database, achieving accuracies of 98.13%, 90.11%, 92.63%, and 91.29%. Additionally, validation on 20 wearable ECG recordings yielded mean accuracies of 99.38% and 99.48% for AF and Non-AF on unlabeled data from recordings used for fine-tuning. We achieved mean accuracies of 97.19% and 94.15% for AF and Non-AF on independent recordings. The results demonstrate the proposed method’s reliability for AF detection in wearable ECG monitoring.
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (6) , 4046-4058
Uncertainty-Inspired Multi-Task Learning in Arbitrary Scenarios of ECG Monitoring
As the scenarios for electrocardiogram (ECG) monitoring become increasingly diverse, particularly with the development of wearable ECG, the influence of ambiguous factors in diagnosis has been amplified. Reliable ECG information must be extracted from abundant noises and confusing artifacts. To address this issue, we suggest an uncertainty-inspired model for beat-level diagnosis (UI-Beat). The base architecture of UI-Beat separates heartbeat localization and event diagnosis in two branches to address the problem of heterogeneous data sources. To disentangle the epistemic and aleatoric uncertainty within one stage in a deterministic neural network, we propose a new method derived from uncertainty formulation and realize it by introducing the class-biased transformation. Then the disentangled uncertainty can be utilized to screen out noise and identify ambiguous heartbeat synchronously. The results indicate that UI-Beat can significantly improve the performance of noise detection (from 91.60% to 97.50% for real-world noise detection and from 61.40% to 82.41% for real-world artifact detection). For multi-lead ECG analysis, UI-Beat is approaching the performance upper bound in heartbeat localization (only 15 false positives and 9 false negatives out of the 175,907 heartbeats in the INCART database) and achieving a significant performance improvement in heartbeat classification through uncertainty-based cross-lead fusion compared to single-lead prediction and other state-of-the-art methods (an average improvement of 14.28% for detecting heartbeats of S and 3.37% for detecting heartbeats of V). Considering the characteristic of one-stage ECG analysis within one model, it is suggested that the proposed UI-Beat has the potential to be employed as a general model for arbitrary scenarios of ECG monitoring, with the capacity to remove invalid episodes, and realize heartbeat-level diagnosis with confidence provided.
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (6) , 4046-4058
Uncertainty-Inspired Multi-Task Learning in Arbitrary Scenarios of ECG Monitoring
As the scenarios for electrocardiogram (ECG) monitoring become increasingly diverse, particularly with the development of wearable ECG, the influence of ambiguous factors in diagnosis has been amplified. Reliable ECG information must be extracted from abundant noises and confusing artifacts. To address this issue, we suggest an uncertainty-inspired model for beat-level diagnosis (UI-Beat). The base architecture of UI-Beat separates heartbeat localization and event diagnosis in two branches to address the problem of heterogeneous data sources. To disentangle the epistemic and aleatoric uncertainty within one stage in a deterministic neural network, we propose a new method derived from uncertainty formulation and realize it by introducing the class-biased transformation. Then the disentangled uncertainty can be utilized to screen out noise and identify ambiguous heartbeat synchronously. The results indicate that UI-Beat can significantly improve the performance of noise detection (from 91.60% to 97.50% for real-world noise detection and from 61.40% to 82.41% for real-world artifact detection). For multi-lead ECG analysis, UI-Beat is approaching the performance upper bound in heartbeat localization (only 15 false positives and 9 false negatives out of the 175,907 heartbeats in the INCART database) and achieving a significant performance improvement in heartbeat classification through uncertainty-based cross-lead fusion compared to single-lead prediction and other state-of-the-art methods (an average improvement of 14.28% for detecting heartbeats of S and 3.37% for detecting heartbeats of V). Considering the characteristic of one-stage ECG analysis within one model, it is suggested that the proposed UI-Beat has the potential to be employed as a general model for arbitrary scenarios of ECG monitoring, with the capacity to remove invalid episodes, and realize heartbeat-level diagnosis with confidence provided.
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
An Optimized Signal Quality Assessment Method for Noncontact Capacitive ECG
Noncontact capacitive electrocardiogram (cECG) is gaining recognition in cardiovascular disease monitoring for its comfort and non-invasiveness. Compared to the conventional ECG, cECG signal quality is prone to degradation in practical applications due to motion artifacts and power line interference (PLI). This study proposed an optimized signal quality assessment method to identify and remove low-quality cECG signals. Firstly, the human body-electrode interface is modeled to analyze the generation mechanism and influence of cECG motion artifacts and PLI. Then, distinct signal quality indices (SQIs) are proposed to target the characteristics of these interferences. Moreover, optimized cECG features and previously proposed ECG features were combined as multi-features and presented to XGBoost for binary classification training. Finally, Shapley Additive Explanations (SHAP) were utilized for feature optimization to reduce redundant information. Validation on a labelled noncontact cECG database yields an impressive binary classification accuracy of 98.786 %, F1-score of 98.845 %, and kappa of 97.567 %. Moreover, its performance on a subject-independent validation set is also excellent, with an accuracy of 99.130 %, an F1-score of 96.937 %, and a kappa of 96.430 %. The optimized multi-features also demonstrate favorable performance in a triple classification model. The experimental results show that our method offers a precise and convenient solution for cECG signal quality assessment.
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
An Optimized Signal Quality Assessment Method for Noncontact Capacitive ECG
Noncontact capacitive electrocardiogram (cECG) is gaining recognition in cardiovascular disease monitoring for its comfort and non-invasiveness. Compared to the conventional ECG, cECG signal quality is prone to degradation in practical applications due to motion artifacts and power line interference (PLI). This study proposed an optimized signal quality assessment method to identify and remove low-quality cECG signals. Firstly, the human body-electrode interface is modeled to analyze the generation mechanism and influence of cECG motion artifacts and PLI. Then, distinct signal quality indices (SQIs) are proposed to target the characteristics of these interferences. Moreover, optimized cECG features and previously proposed ECG features were combined as multi-features and presented to XGBoost for binary classification training. Finally, Shapley Additive Explanations (SHAP) were utilized for feature optimization to reduce redundant information. Validation on a labelled noncontact cECG database yields an impressive binary classification accuracy of 98.786 %, F1-score of 98.845 %, and kappa of 97.567 %. Moreover, its performance on a subject-independent validation set is also excellent, with an accuracy of 99.130 %, an F1-score of 96.937 %, and a kappa of 96.430 %. The optimized multi-features also demonstrate favorable performance in a triple classification model. The experimental results show that our method offers a precise and convenient solution for cECG signal quality assessment.
- 16 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Online Co-Learning Strategy Based on Multibranch Multiscale Network for 12-Lead ECG Classification
The coexistence of multiple cardiovascular diseases (CVDs) will increase the burden on cardiac function and increase the patient’s risk of death. The 12-lead electrocardiogram (ECG) offers a more comprehensive assessment of cardiac electrical activity and serves as a vital tool for multi-label ECG classification. However, 12-lead ECG is high-dimensional data, and designing the model structure capable of capturing the complex relationships between different leads is important. Additionally, deep learning tends to overfit small samples, so improving the model’s generalization ability is crucial. In response, we have developed an online co-learning (OCL) strategy based on multi-branch multi-scale residual fusion network (2MRFNet) for 12-lead ECG multi-label classification. The 2MRFNet primarily comprises two key modules: the multi-branch multi-scale residual (MBSR) module and the scale heterogeneous attention fusion (SHAF) module. These modules are employed to extract and fuse features on multi-scale from three groups of leads: standard, limb, and chest leads. The OCL strategy effectively leverages the transfer of feature information between models to enhance model generalization capability. The PTB-XL and CPSC-2018 datasets were used as validation sets. The proposed method achieved an average AUC score of 93.38% and an average F1 score of 48.51% for five tasks on the PTB-XL dataset. On the CPSC-2018 dataset, the corresponding results are 97.37% and 84.40%. Compared to known state-of-the-art methods, the proposed method exhibited the highest multi-label classification performance across various experiments.
- 16 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Online Co-Learning Strategy Based on Multibranch Multiscale Network for 12-Lead ECG Classification
The coexistence of multiple cardiovascular diseases (CVDs) will increase the burden on cardiac function and increase the patient’s risk of death. The 12-lead electrocardiogram (ECG) offers a more comprehensive assessment of cardiac electrical activity and serves as a vital tool for multi-label ECG classification. However, 12-lead ECG is high-dimensional data, and designing the model structure capable of capturing the complex relationships between different leads is important. Additionally, deep learning tends to overfit small samples, so improving the model’s generalization ability is crucial. In response, we have developed an online co-learning (OCL) strategy based on multi-branch multi-scale residual fusion network (2MRFNet) for 12-lead ECG multi-label classification. The 2MRFNet primarily comprises two key modules: the multi-branch multi-scale residual (MBSR) module and the scale heterogeneous attention fusion (SHAF) module. These modules are employed to extract and fuse features on multi-scale from three groups of leads: standard, limb, and chest leads. The OCL strategy effectively leverages the transfer of feature information between models to enhance model generalization capability. The PTB-XL and CPSC-2018 datasets were used as validation sets. The proposed method achieved an average AUC score of 93.38% and an average F1 score of 48.51% for five tasks on the PTB-XL dataset. On the CPSC-2018 dataset, the corresponding results are 97.37% and 84.40%. Compared to known state-of-the-art methods, the proposed method exhibited the highest multi-label classification performance across various experiments.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Hybrid Amplitude Ordinal Partition Networks for ECG Morphology Discrimination: An Application to PVC Recognition
Various algorithms have emerged for automatic electrocardiogram (ECG) analysis, focusing on discerning subtle changes in arrhythmic morphology, especially premature ventricular contractions (PVCs). While ordinal partition networks (OPNs) have been effective in analyzing real-world time series data, conventional OPNs primarily concentrate on local ECG shapes, overlooking amplitude-level information. This study introduces an innovative method, absolute amplitude OPNs (AAOPNs), which incorporates amplitude-level variations (coarse-grained ECG) into ordinal patterns. These AAOPNs encompass all conceivable ordinal patterns as nodes, connected based on temporal sequences. Ten network measures are extracted from both OPNs and AAOPNs, capturing the shape and level-based PVCs characteristics. These measures are integrated into hybrid amplitude OPNs (HAOPNs) to construct support vector machine (SVM)-based PVCs recognition models. Evaluated on three baseline databases [Massachusetts Institute of Technology-Beth Israel Hospital arrhythmia database (96587 beats), St. Petersburg Institute of Cardiological Technics database (156373 beats), and China Physiological Signal Challenge 2020 database (987209 beats)], the proposed models demonstrate F1-scores of 97.02%, 93.06%, and 91.03% across databases in class-oriented evaluation, and 94.57%, 87.96%, and 88.89% in subject-oriented evaluation. Notably, the model achieves PVCs scores of 53904 and 59201 on the China Physiological Signal Challenge 2020 test set for the two evaluations, affirming its efficacy in PVCs recognition. This framework provides a versatile approach for detecting morphology anomalies in various physiological signals, such as heart sounds and pulses.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Hybrid Amplitude Ordinal Partition Networks for ECG Morphology Discrimination: An Application to PVC Recognition
Various algorithms have emerged for automatic electrocardiogram (ECG) analysis, focusing on discerning subtle changes in arrhythmic morphology, especially premature ventricular contractions (PVCs). While ordinal partition networks (OPNs) have been effective in analyzing real-world time series data, conventional OPNs primarily concentrate on local ECG shapes, overlooking amplitude-level information. This study introduces an innovative method, absolute amplitude OPNs (AAOPNs), which incorporates amplitude-level variations (coarse-grained ECG) into ordinal patterns. These AAOPNs encompass all conceivable ordinal patterns as nodes, connected based on temporal sequences. Ten network measures are extracted from both OPNs and AAOPNs, capturing the shape and level-based PVCs characteristics. These measures are integrated into hybrid amplitude OPNs (HAOPNs) to construct support vector machine (SVM)-based PVCs recognition models. Evaluated on three baseline databases [Massachusetts Institute of Technology-Beth Israel Hospital arrhythmia database (96587 beats), St. Petersburg Institute of Cardiological Technics database (156373 beats), and China Physiological Signal Challenge 2020 database (987209 beats)], the proposed models demonstrate F1-scores of 97.02%, 93.06%, and 91.03% across databases in class-oriented evaluation, and 94.57%, 87.96%, and 88.89% in subject-oriented evaluation. Notably, the model achieves PVCs scores of 53904 and 59201 on the China Physiological Signal Challenge 2020 test set for the two evaluations, affirming its efficacy in PVCs recognition. This framework provides a versatile approach for detecting morphology anomalies in various physiological signals, such as heart sounds and pulses.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
An Atrial Fibrillation Detection Strategy in Dynamic ECGs With Significant Individual Differences
Atrial fibrillation (AF) is an insidious disease. Many long-term wearable electrocardiogram (ECG) monitoring devices have been used to monitor AF. The accuracy of detectors used to classify AF/sinus rhythm is already very high on the public database. Due to the significant individual differences and interference from other arrhythmias (e.g., premature beats), the performance of the developed AF detectors can degrade when tested on wearable ECGs. To tackle this, we proposed to use domain-adversarial (DA) learning strategy to minimize feature distribution between the annotated public ECG database (the MIT-BIH AF database) and unlabeled dynamic ECG recordings to improve AF recognition accuracy. DA algorithms based on the shifted window Transformer (DA-ST) and residual neural network (DA-RN) were proposed and validated on the 2021 China Physiological Signal Challenge (CPSC) database including four datasets. The accuracies were 93.85%, 89.78%, 91.93%, and 87.35% on the four datasets when using DA-ST. The corresponding results were 96.67%, 92.25%, 90.58%, and 89.46% when utilizing DA-RN. Importantly, these results demonstrated superior performance compared to the results obtained without DA. The proposed method was validated on 12 wearable long-term recordings, consisting of 4 recordings with premature beats, 4 recordings of AF with premature beats, 2 recordings of sinus rhythms, and 2 recordings of AF. The average results were 98.67% (DA-ST) and 97.89% (DA-RN), proving that the proposed method could provide reliable AF detection for dynamic ECG recordings with significant individual differences.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
An Atrial Fibrillation Detection Strategy in Dynamic ECGs With Significant Individual Differences
Atrial fibrillation (AF) is an insidious disease. Many long-term wearable electrocardiogram (ECG) monitoring devices have been used to monitor AF. The accuracy of detectors used to classify AF/sinus rhythm is already very high on the public database. Due to the significant individual differences and interference from other arrhythmias (e.g., premature beats), the performance of the developed AF detectors can degrade when tested on wearable ECGs. To tackle this, we proposed to use domain-adversarial (DA) learning strategy to minimize feature distribution between the annotated public ECG database (the MIT-BIH AF database) and unlabeled dynamic ECG recordings to improve AF recognition accuracy. DA algorithms based on the shifted window Transformer (DA-ST) and residual neural network (DA-RN) were proposed and validated on the 2021 China Physiological Signal Challenge (CPSC) database including four datasets. The accuracies were 93.85%, 89.78%, 91.93%, and 87.35% on the four datasets when using DA-ST. The corresponding results were 96.67%, 92.25%, 90.58%, and 89.46% when utilizing DA-RN. Importantly, these results demonstrated superior performance compared to the results obtained without DA. The proposed method was validated on 12 wearable long-term recordings, consisting of 4 recordings with premature beats, 4 recordings of AF with premature beats, 2 recordings of sinus rhythms, and 2 recordings of AF. The average results were 98.67% (DA-ST) and 97.89% (DA-RN), proving that the proposed method could provide reliable AF detection for dynamic ECG recordings with significant individual differences.
- 18 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (2) , 322-333
Human Eye Activity Monitoring Using Continuous Wave Doppler Radar: A Feasibility Study
Human eye activity has been widely studied in many fields such as psychology, neuroscience, medicine, and human-computer interaction engineering. In previous studies, monitoring of human eye activity mainly depends on electrooculogram (EOG) that requires a contact sensor. This paper proposes a novel eye movement monitoring method called continuous wave doppler oculogram (cDOG). Unlike the conventional EOG-based eye movement monitoring methods, cDOG based on continuous wave doppler radar sensor (cDRS) can remotely measure human eye activity without placing electrodes on the head. To verify the feasibility of using cDOG for eye movement monitoring, we first theoretically analyzed the association between the radar signal and the corresponding eye movements measured with EOG. Afterward, we conducted an experiment to compare EOG and cDOG measurements under the conditions of eyes closure and opening. In addition, different eye movement states were considered, including right-left saccade, up-down saccade, eye-blink, and fixation. Several representative time domain and frequency domain features obtained from cDOG and from EOG were compared in these states, allowing us to demonstrate the feasibility of using cDOG for monitoring eye movements. The experimental results show that there is a correlation between cDOG and EOG in the time and frequency domain features, the average time error of single eye movement is less than 280.5 ms, and the accuracy of cDOG in eye movement detection is higher than 92.35%, when the distance between the cDRS and the face is 10 cm and eyes is facing the radar directly.
- 18 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (2) , 322-333
Human Eye Activity Monitoring Using Continuous Wave Doppler Radar: A Feasibility Study
Human eye activity has been widely studied in many fields such as psychology, neuroscience, medicine, and human-computer interaction engineering. In previous studies, monitoring of human eye activity mainly depends on electrooculogram (EOG) that requires a contact sensor. This paper proposes a novel eye movement monitoring method called continuous wave doppler oculogram (cDOG). Unlike the conventional EOG-based eye movement monitoring methods, cDOG based on continuous wave doppler radar sensor (cDRS) can remotely measure human eye activity without placing electrodes on the head. To verify the feasibility of using cDOG for eye movement monitoring, we first theoretically analyzed the association between the radar signal and the corresponding eye movements measured with EOG. Afterward, we conducted an experiment to compare EOG and cDOG measurements under the conditions of eyes closure and opening. In addition, different eye movement states were considered, including right-left saccade, up-down saccade, eye-blink, and fixation. Several representative time domain and frequency domain features obtained from cDOG and from EOG were compared in these states, allowing us to demonstrate the feasibility of using cDOG for monitoring eye movements. The experimental results show that there is a correlation between cDOG and EOG in the time and frequency domain features, the average time error of single eye movement is less than 280.5 ms, and the accuracy of cDOG in eye movement detection is higher than 92.35%, when the distance between the cDRS and the face is 10 cm and eyes is facing the radar directly.
- 9 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (3) , 876-892
A Review on Atrial Fibrillation Detection From Ambulatory ECG
Atrial fibrillation (AF) is a prevalent clinical arrhythmia disease and is an important cause of stroke, heart failure, and sudden death. Due to the insidious onset and no obvious clinical symptoms of AF, the status of AF diagnosis and treatment is not optimal. Early AF screening or detection is essential. Internet of Things (IoT) and artificial intelligence (AI) technologies have driven the development of wearable electrocardiograph (ECG) devices used for health monitoring, which are an effective means of AF detection. The main challenges of AF analysis using ambulatory ECG include ECG signal quality assessment to select available ECG, the robust and accurate detection of QRS complex waves to monitor heart rate, and AF identification under the interference of abnormal ECG rhythm. Through ambulatory ECG measurement and intelligent detection technology, the probability of postoperative recurrence of AF can be reduced, and personalized treatment and management of patients with AF can be realized. This work describes the status of AF monitoring technology in terms of devices, algorithms, clinical applications, and future directions.
- 9 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (3) , 876-892
A Review on Atrial Fibrillation Detection From Ambulatory ECG
Atrial fibrillation (AF) is a prevalent clinical arrhythmia disease and is an important cause of stroke, heart failure, and sudden death. Due to the insidious onset and no obvious clinical symptoms of AF, the status of AF diagnosis and treatment is not optimal. Early AF screening or detection is essential. Internet of Things (IoT) and artificial intelligence (AI) technologies have driven the development of wearable electrocardiograph (ECG) devices used for health monitoring, which are an effective means of AF detection. The main challenges of AF analysis using ambulatory ECG include ECG signal quality assessment to select available ECG, the robust and accurate detection of QRS complex waves to monitor heart rate, and AF identification under the interference of abnormal ECG rhythm. Through ambulatory ECG measurement and intelligent detection technology, the probability of postoperative recurrence of AF can be reduced, and personalized treatment and management of patients with AF can be realized. This work describes the status of AF monitoring technology in terms of devices, algorithms, clinical applications, and future directions.