Lina Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lina Zhao has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Chengyu Liu
State Key Laboratory of Digital Medical Engineering, School of Instrument Science and Engineering, Southeast University, Nanjing, China
12 shared publications - Jianqing Li
School of Instrument Science and Engineering, Southeast University, Nanjing, China
8 shared publications - Shoushui Wei
School of Control Science and Engineering, Shandong University, Jinan, China
4 shared publications - Caiyun Ma
State Key Laboratory of Digital Medical Engineering, School of Instrument Science and Engineering, Southeast University, Nanjing, China
3 shared publications - Jinle Xiong
The State Key Laboratory of Bioelectronics, School of Instrument Science and Engineering, Southeast University, Nanjing 210096, China
3 shared publications - Rik Vullings
Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
2 shared publications
Latest Publications
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73  (8) , 2795-2810
Uncertainty-Aware Evidential Multi-Modal Fusion Network for Large-Scale Multi-Center Major Depressive Disorder Classification
The clinical diagnosis of major depressive disorder (MDD) has long relied on subjective assessments, underscoring the need for objective and quantifiable automated diagnostic methods. Existing neuroimaging-based multimodal fusion methods face three core challenges: the lack of mechanisms that dynamically assess modality reliability, the absence of effective prediction uncertainty quantification, and site effects in multi-center data that constrain model generalizability. To mitigate these issues, we propose an uncertainty-aware evidential multimodal fusion network for large-scale multi-center MDD classification. We design deep functional feature extractors (DFFE) and dual-stream hierarchical feature fusion (DS-HFF) modules to encode functional magnetic resonance imaging (fMRI) and structural MRI (sMRI) features, respectively. An Evidential Multimodal Fusion (EMF) strategy based on Dempster–Shafer theory (DST) is designed to convert each modality's categorical support into subjective opinions with explicit uncertainty. Reliable cross-modal evidence integration is achieved through context-adaptive discounting and conflict-aware combination. Site-adversarial regularization is incorporated to learn site-invariant pathological feature representations. Evaluated on the REST-meta-MDD dataset comprising 1,601 subjects from 16 sites under a leave-one-site-out cross-validation (LOSO-CV) scheme, the proposed method outperforms recently published methods. Uncertainty analysis demonstrates superior calibration over Softmax and MC Dropout baselines, and the uncertainty-based rejection mechanism further improves the classification performance. Interpretability analysis identifies key brain regions highly consistent with established MDD pathophysiological findings, further validating the clinical reliability of the framework. Experimental results indicate that our proposed method has the potential to provide a robust, trustworthy, and interpretable solution for multi-center MDD diagnosis.
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73  (8) , 2795-2810
Uncertainty-Aware Evidential Multi-Modal Fusion Network for Large-Scale Multi-Center Major Depressive Disorder Classification
The clinical diagnosis of major depressive disorder (MDD) has long relied on subjective assessments, underscoring the need for objective and quantifiable automated diagnostic methods. Existing neuroimaging-based multimodal fusion methods face three core challenges: the lack of mechanisms that dynamically assess modality reliability, the absence of effective prediction uncertainty quantification, and site effects in multi-center data that constrain model generalizability. To mitigate these issues, we propose an uncertainty-aware evidential multimodal fusion network for large-scale multi-center MDD classification. We design deep functional feature extractors (DFFE) and dual-stream hierarchical feature fusion (DS-HFF) modules to encode functional magnetic resonance imaging (fMRI) and structural MRI (sMRI) features, respectively. An Evidential Multimodal Fusion (EMF) strategy based on Dempster–Shafer theory (DST) is designed to convert each modality's categorical support into subjective opinions with explicit uncertainty. Reliable cross-modal evidence integration is achieved through context-adaptive discounting and conflict-aware combination. Site-adversarial regularization is incorporated to learn site-invariant pathological feature representations. Evaluated on the REST-meta-MDD dataset comprising 1,601 subjects from 16 sites under a leave-one-site-out cross-validation (LOSO-CV) scheme, the proposed method outperforms recently published methods. Uncertainty analysis demonstrates superior calibration over Softmax and MC Dropout baselines, and the uncertainty-based rejection mechanism further improves the classification performance. Interpretability analysis identifies key brain regions highly consistent with established MDD pathophysiological findings, further validating the clinical reliability of the framework. Experimental results indicate that our proposed method has the potential to provide a robust, trustworthy, and interpretable solution for multi-center MDD diagnosis.
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74  (00189456) , 1-11
An Atrial Fibrillation Detection Strategy Based on Self-Supervised Pretraining in Wearable ECG Monitoring
Atrial fibrillation (AF) is an insidious cardiac arrhythmia, with its incidence increasing annually. Timely screening and home-based interventions play a vital role in the effective management of atrial fibrillation (AF). Within the Internet of Medical Things (IoMT) landscape, wearable electrocardiogram (ECG) monitoring devices have been seamlessly integrated to monitor AF. Nonetheless, the substantial influx of ECG signals awaiting annotation and the exorbitant costs associated with employing specialists for manual annotation pose significant hurdles in the development of AF detection systems. Despite the potential utilization of AF detectors trained on open databases, their efficacy in analyzing continuous wearable ECGs remains inadequate. Self-supervised representation learning proficiently characterizes unlabeled data and enhances data utilization without labels. This study proposes an AF detection strategy based on self-supervised pre-training, aiming for optimal AF detection performance with minimal annotation costs. The proposed method employed self-supervised representation learning and pre-training strategy and was validated on four datasets from the 4th China Physiological Signal Challenge (CPSC2021) database, achieving accuracies of 98.13%, 90.11%, 92.63%, and 91.29%. Additionally, validation on 20 wearable ECG recordings yielded mean accuracies of 99.38% and 99.48% for AF and Non-AF on unlabeled data from recordings used for fine-tuning. We achieved mean accuracies of 97.19% and 94.15% for AF and Non-AF on independent recordings. The results demonstrate the proposed method’s reliability for AF detection in wearable ECG monitoring.
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74  (00189456) , 1-11
An Atrial Fibrillation Detection Strategy Based on Self-Supervised Pretraining in Wearable ECG Monitoring
Atrial fibrillation (AF) is an insidious cardiac arrhythmia, with its incidence increasing annually. Timely screening and home-based interventions play a vital role in the effective management of atrial fibrillation (AF). Within the Internet of Medical Things (IoMT) landscape, wearable electrocardiogram (ECG) monitoring devices have been seamlessly integrated to monitor AF. Nonetheless, the substantial influx of ECG signals awaiting annotation and the exorbitant costs associated with employing specialists for manual annotation pose significant hurdles in the development of AF detection systems. Despite the potential utilization of AF detectors trained on open databases, their efficacy in analyzing continuous wearable ECGs remains inadequate. Self-supervised representation learning proficiently characterizes unlabeled data and enhances data utilization without labels. This study proposes an AF detection strategy based on self-supervised pre-training, aiming for optimal AF detection performance with minimal annotation costs. The proposed method employed self-supervised representation learning and pre-training strategy and was validated on four datasets from the 4th China Physiological Signal Challenge (CPSC2021) database, achieving accuracies of 98.13%, 90.11%, 92.63%, and 91.29%. Additionally, validation on 20 wearable ECG recordings yielded mean accuracies of 99.38% and 99.48% for AF and Non-AF on unlabeled data from recordings used for fine-tuning. We achieved mean accuracies of 97.19% and 94.15% for AF and Non-AF on independent recordings. The results demonstrate the proposed method’s reliability for AF detection in wearable ECG monitoring.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73  (00189456) , 1-10
An Atrial Fibrillation Detection Strategy in Dynamic ECGs With Significant Individual Differences
Atrial fibrillation (AF) is an insidious disease. Many long-term wearable electrocardiogram (ECG) monitoring devices have been used to monitor AF. The accuracy of detectors used to classify AF/sinus rhythm is already very high on the public database. Due to the significant individual differences and interference from other arrhythmias (e.g., premature beats), the performance of the developed AF detectors can degrade when tested on wearable ECGs. To tackle this, we proposed to use domain-adversarial (DA) learning strategy to minimize feature distribution between the annotated public ECG database (the MIT-BIH AF database) and unlabeled dynamic ECG recordings to improve AF recognition accuracy. DA algorithms based on the shifted window Transformer (DA-ST) and residual neural network (DA-RN) were proposed and validated on the 2021 China Physiological Signal Challenge (CPSC) database including four datasets. The accuracies were 93.85%, 89.78%, 91.93%, and 87.35% on the four datasets when using DA-ST. The corresponding results were 96.67%, 92.25%, 90.58%, and 89.46% when utilizing DA-RN. Importantly, these results demonstrated superior performance compared to the results obtained without DA. The proposed method was validated on 12 wearable long-term recordings, consisting of 4 recordings with premature beats, 4 recordings of AF with premature beats, 2 recordings of sinus rhythms, and 2 recordings of AF. The average results were 98.67% (DA-ST) and 97.89% (DA-RN), proving that the proposed method could provide reliable AF detection for dynamic ECG recordings with significant individual differences.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73  (00189456) , 1-10
An Atrial Fibrillation Detection Strategy in Dynamic ECGs With Significant Individual Differences
Atrial fibrillation (AF) is an insidious disease. Many long-term wearable electrocardiogram (ECG) monitoring devices have been used to monitor AF. The accuracy of detectors used to classify AF/sinus rhythm is already very high on the public database. Due to the significant individual differences and interference from other arrhythmias (e.g., premature beats), the performance of the developed AF detectors can degrade when tested on wearable ECGs. To tackle this, we proposed to use domain-adversarial (DA) learning strategy to minimize feature distribution between the annotated public ECG database (the MIT-BIH AF database) and unlabeled dynamic ECG recordings to improve AF recognition accuracy. DA algorithms based on the shifted window Transformer (DA-ST) and residual neural network (DA-RN) were proposed and validated on the 2021 China Physiological Signal Challenge (CPSC) database including four datasets. The accuracies were 93.85%, 89.78%, 91.93%, and 87.35% on the four datasets when using DA-ST. The corresponding results were 96.67%, 92.25%, 90.58%, and 89.46% when utilizing DA-RN. Importantly, these results demonstrated superior performance compared to the results obtained without DA. The proposed method was validated on 12 wearable long-term recordings, consisting of 4 recordings with premature beats, 4 recordings of AF with premature beats, 2 recordings of sinus rhythms, and 2 recordings of AF. The average results were 98.67% (DA-ST) and 97.89% (DA-RN), proving that the proposed method could provide reliable AF detection for dynamic ECG recordings with significant individual differences.
- 9 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71  (3) , 876-892
A Review on Atrial Fibrillation Detection From Ambulatory ECG
Atrial fibrillation (AF) is a prevalent clinical arrhythmia disease and is an important cause of stroke, heart failure, and sudden death. Due to the insidious onset and no obvious clinical symptoms of AF, the status of AF diagnosis and treatment is not optimal. Early AF screening or detection is essential. Internet of Things (IoT) and artificial intelligence (AI) technologies have driven the development of wearable electrocardiograph (ECG) devices used for health monitoring, which are an effective means of AF detection. The main challenges of AF analysis using ambulatory ECG include ECG signal quality assessment to select available ECG, the robust and accurate detection of QRS complex waves to monitor heart rate, and AF identification under the interference of abnormal ECG rhythm. Through ambulatory ECG measurement and intelligent detection technology, the probability of postoperative recurrence of AF can be reduced, and personalized treatment and management of patients with AF can be realized. This work describes the status of AF monitoring technology in terms of devices, algorithms, clinical applications, and future directions.
- 9 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71  (3) , 876-892
A Review on Atrial Fibrillation Detection From Ambulatory ECG
Atrial fibrillation (AF) is a prevalent clinical arrhythmia disease and is an important cause of stroke, heart failure, and sudden death. Due to the insidious onset and no obvious clinical symptoms of AF, the status of AF diagnosis and treatment is not optimal. Early AF screening or detection is essential. Internet of Things (IoT) and artificial intelligence (AI) technologies have driven the development of wearable electrocardiograph (ECG) devices used for health monitoring, which are an effective means of AF detection. The main challenges of AF analysis using ambulatory ECG include ECG signal quality assessment to select available ECG, the robust and accurate detection of QRS complex waves to monitor heart rate, and AF identification under the interference of abnormal ECG rhythm. Through ambulatory ECG measurement and intelligent detection technology, the probability of postoperative recurrence of AF can be reduced, and personalized treatment and management of patients with AF can be realized. This work describes the status of AF monitoring technology in terms of devices, algorithms, clinical applications, and future directions.
- Open Access
- 8 April 2021
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 21  (05) , 2140019
ANALYSIS OF PHOTOPLETHYSMOGRAPHIC MORPHOLOGY IN SLEEP APNEA SYNDROME PATIENTS USING CURVE FITTING AND SUPPORT VECTOR MACHINE
- 8 April 2021
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 21  (05) , 2140019
Open AccessANALYSIS OF PHOTOPLETHYSMOGRAPHIC MORPHOLOGY IN SLEEP APNEA SYNDROME PATIENTS USING CURVE FITTING AND SUPPORT VECTOR MACHINE
- Open Access
Improving Accuracy of Heart Failure Detection Using Data Refinement
Due to the wide inter- and intra-individual variability, short-term heart rate variability (HRV) analysis (usually 5 min) might lead to inaccuracy in detecting heart failure. Therefore, RR interval segmentation, which can reflect the individual heart condition, has been a key research challenge for accurate detection of heart failure. Previous studies mainly focus on analyzing the entire 24-h ECG recordings from all individuals in the database which often led to poor detection rate. In this study, we propose a set of data refinement procedures, which can automatically extract heart failure segments and yield better detection of heart failure. The procedures roughly contain three steps: (1) select fast heart rate sequences, (2) apply dynamic time warping (DTW) measure to filter out dissimilar segments, and (3) pick out individuals with large numbers of segments preserved. A physical threshold-based Sample Entropy (SampEn) was applied to distinguish congestive heart failure (CHF) subjects from normal sinus rhythm (NSR) ones, and results using the traditional threshold were also discussed. Experiment on the PhysioNet/MIT RR Interval Databases showed that in SampEn analysis (embedding dimension m = 1, tolerance threshold r = 12 ms and time series length N = 300), the accuracy value after data refinement has increased to 90.46% from 75.07%. Meanwhile, for the proposed procedures, the area under receiver operating characteristic curve (AUC) value has reached 95.73%, which outperforms the original method (i.e., without applying the proposed data refinement procedures) with AUC of 76.83%. The results have shown that our proposed data refinement procedures can significantly improve the accuracy in heart failure detection.
Open AccessImproving Accuracy of Heart Failure Detection Using Data Refinement
Due to the wide inter- and intra-individual variability, short-term heart rate variability (HRV) analysis (usually 5 min) might lead to inaccuracy in detecting heart failure. Therefore, RR interval segmentation, which can reflect the individual heart condition, has been a key research challenge for accurate detection of heart failure. Previous studies mainly focus on analyzing the entire 24-h ECG recordings from all individuals in the database which often led to poor detection rate. In this study, we propose a set of data refinement procedures, which can automatically extract heart failure segments and yield better detection of heart failure. The procedures roughly contain three steps: (1) select fast heart rate sequences, (2) apply dynamic time warping (DTW) measure to filter out dissimilar segments, and (3) pick out individuals with large numbers of segments preserved. A physical threshold-based Sample Entropy (SampEn) was applied to distinguish congestive heart failure (CHF) subjects from normal sinus rhythm (NSR) ones, and results using the traditional threshold were also discussed. Experiment on the PhysioNet/MIT RR Interval Databases showed that in SampEn analysis (embedding dimension m = 1, tolerance threshold r = 12 ms and time series length N = 300), the accuracy value after data refinement has increased to 90.46% from 75.07%. Meanwhile, for the proposed procedures, the area under receiver operating characteristic curve (AUC) value has reached 95.73%, which outperforms the original method (i.e., without applying the proposed data refinement procedures) with AUC of 76.83%. The results have shown that our proposed data refinement procedures can significantly improve the accuracy in heart failure detection.
- Open Access
Suppressing the Influence of Ectopic Beats by Applying a Physical Threshold-Based Sample Entropy
Sample entropy (SampEn) is widely used for electrocardiogram (ECG) signal analysis to quantify the inherent complexity or regularity of RR interval time series (i.e., heart rate variability (HRV)), with the hypothesis that RR interval time series in pathological conditions output lower SampEn values. However, ectopic beats can significantly influence the entropy values, resulting in difficulty in distinguishing the pathological situation from normal situations. Although a theoretical operation is to exclude the ectopic intervals during HRV analysis, it is not easy to identify all of them in practice, especially for the dynamic ECG signal. Thus, it is important to suppress the influence of ectopic beats on entropy results, i.e., to improve the robustness and stability of entropy measurement for ectopic beats-inserted RR interval time series. In this study, we introduced a physical threshold-based SampEn method, and tested its ability to suppress the influence of ectopic beats for HRV analysis. An experiment on the PhysioNet/MIT RR Interval Databases showed that the SampEn use physical meaning threshold has better performance not only for different data types (normal sinus rhythm (NSR) or congestive heart failure (CHF) recordings), but also for different types of ectopic beat (atrial beats, ventricular beats or both), indicating that using a physical meaning threshold makes SampEn become more consistent and stable.
Open AccessSuppressing the Influence of Ectopic Beats by Applying a Physical Threshold-Based Sample Entropy
Sample entropy (SampEn) is widely used for electrocardiogram (ECG) signal analysis to quantify the inherent complexity or regularity of RR interval time series (i.e., heart rate variability (HRV)), with the hypothesis that RR interval time series in pathological conditions output lower SampEn values. However, ectopic beats can significantly influence the entropy values, resulting in difficulty in distinguishing the pathological situation from normal situations. Although a theoretical operation is to exclude the ectopic intervals during HRV analysis, it is not easy to identify all of them in practice, especially for the dynamic ECG signal. Thus, it is important to suppress the influence of ectopic beats on entropy results, i.e., to improve the robustness and stability of entropy measurement for ectopic beats-inserted RR interval time series. In this study, we introduced a physical threshold-based SampEn method, and tested its ability to suppress the influence of ectopic beats for HRV analysis. An experiment on the PhysioNet/MIT RR Interval Databases showed that the SampEn use physical meaning threshold has better performance not only for different data types (normal sinus rhythm (NSR) or congestive heart failure (CHF) recordings), but also for different types of ectopic beat (atrial beats, ventricular beats or both), indicating that using a physical meaning threshold makes SampEn become more consistent and stable.
- Open Access
A New Physically Meaningful Threshold of Sample Entropy for Detecting Cardiovascular Diseases
Sample Entropy (SampEn) is a popular method for assessing the regularity of physiological signals. Prior to the entropy calculation, certain common parameters need to be initialized: Embedding dimension m, tolerance threshold r and time series length N. Nevertheless, the determination of these parameters is usually based on expert experience. Improper assignments of these parameters tend to bring invalid values, inconsistency and low statistical significance in entropy calculation. In this study, we proposed a new tolerance threshold with physical meaning ( ), which was based on the sampling resolution of physiological signals. Statistical significance, percentage of invalid entropy values and ROC curve were used to evaluate the proposed against the traditional threshold ( ). Normal sinus rhythm (NSR), congestive heart failure (CHF) as well as atrial fibrillation (AF) RR interval recordings from Physionet were used as the test data. The results demonstrated that the proposed had better stability than , hence more adaptive to detect cardiovascular diseases of CHF and AF.Open AccessA New Physically Meaningful Threshold of Sample Entropy for Detecting Cardiovascular Diseases
Sample Entropy (SampEn) is a popular method for assessing the regularity of physiological signals. Prior to the entropy calculation, certain common parameters need to be initialized: Embedding dimension m, tolerance threshold r and time series length N. Nevertheless, the determination of these parameters is usually based on expert experience. Improper assignments of these parameters tend to bring invalid values, inconsistency and low statistical significance in entropy calculation. In this study, we proposed a new tolerance threshold with physical meaning ( ), which was based on the sampling resolution of physiological signals. Statistical significance, percentage of invalid entropy values and ROC curve were used to evaluate the proposed against the traditional threshold ( ). Normal sinus rhythm (NSR), congestive heart failure (CHF) as well as atrial fibrillation (AF) RR interval recordings from Physionet were used as the test data. The results demonstrated that the proposed had better stability than , hence more adaptive to detect cardiovascular diseases of CHF and AF. - Open Access
A New Entropy-Based Atrial Fibrillation Detection Method for Scanning Wearable ECG Recordings
Entropy-based atrial fibrillation (AF) detectors have been applied for short-term electrocardiogram (ECG) analysis. However, existing methods suffer from several limitations. To enhance the performance of entropy-based AF detectors, we have developed a new entropy measure, named EntropyAF, which includes the following improvements: (1) use of a ranged function rather than the Chebyshev function to define vector distance, (2) use of a fuzzy function to determine vector similarity, (3) replacement of the probability estimation with density estimation for entropy calculation, (4) use of a flexible distance threshold parameter, and (5) use of adjusted entropy results for the heart rate effect. EntropyAF was trained using the MIT-BIH Atrial Fibrillation (AF) database, and tested on the clinical wearable long-term AF recordings. Three previous entropy-based AF detectors were used for comparison: sample entropy (SampEn), fuzzy measure entropy (FuzzyMEn) and coefficient of sample entropy (COSEn). For classifying AF and non-AF rhythms in the MIT-BIH AF database, EntropyAF achieved the highest area under receiver operating characteristic curve (AUC) values of 98.15% when using a 30-beat time window, which was higher than COSEn with AUC of 91.86%. SampEn and FuzzyMEn resulted in much lower AUCs of 74.68% and 79.24% respectively. For classifying AF and non-AF rhythms in the clinical wearable AF database, EntropyAF also generated the largest values of Youden index (77.94%), sensitivity (92.77%), specificity (85.17%), accuracy (87.10%), positive predictivity (68.09%) and negative predictivity (97.18%). COSEn had the second-best accuracy of 78.63%, followed by an accuracy of 65.08% in FuzzyMEn and an accuracy of 59.91% in SampEn. The new proposed EntropyAF also generated highest classification accuracy when using a 12-beat time window. In addition, the results from time cost analysis verified the efficiency of the new EntropyAF. This study showed the better discrimination ability for identifying AF when using EntropyAF method, indicating that it would be useful for the practical clinical wearable AF scanning.
Open AccessA New Entropy-Based Atrial Fibrillation Detection Method for Scanning Wearable ECG Recordings
Entropy-based atrial fibrillation (AF) detectors have been applied for short-term electrocardiogram (ECG) analysis. However, existing methods suffer from several limitations. To enhance the performance of entropy-based AF detectors, we have developed a new entropy measure, named EntropyAF, which includes the following improvements: (1) use of a ranged function rather than the Chebyshev function to define vector distance, (2) use of a fuzzy function to determine vector similarity, (3) replacement of the probability estimation with density estimation for entropy calculation, (4) use of a flexible distance threshold parameter, and (5) use of adjusted entropy results for the heart rate effect. EntropyAF was trained using the MIT-BIH Atrial Fibrillation (AF) database, and tested on the clinical wearable long-term AF recordings. Three previous entropy-based AF detectors were used for comparison: sample entropy (SampEn), fuzzy measure entropy (FuzzyMEn) and coefficient of sample entropy (COSEn). For classifying AF and non-AF rhythms in the MIT-BIH AF database, EntropyAF achieved the highest area under receiver operating characteristic curve (AUC) values of 98.15% when using a 30-beat time window, which was higher than COSEn with AUC of 91.86%. SampEn and FuzzyMEn resulted in much lower AUCs of 74.68% and 79.24% respectively. For classifying AF and non-AF rhythms in the clinical wearable AF database, EntropyAF also generated the largest values of Youden index (77.94%), sensitivity (92.77%), specificity (85.17%), accuracy (87.10%), positive predictivity (68.09%) and negative predictivity (97.18%). COSEn had the second-best accuracy of 78.63%, followed by an accuracy of 65.08% in FuzzyMEn and an accuracy of 59.91% in SampEn. The new proposed EntropyAF also generated highest classification accuracy when using a 12-beat time window. In addition, the results from time cost analysis verified the efficiency of the new EntropyAF. This study showed the better discrimination ability for identifying AF when using EntropyAF method, indicating that it would be useful for the practical clinical wearable AF scanning.