Kenneth Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kenneth Fan has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Daniel Fried
Univ. of California/San Francisco (United States)
5 shared publications- Daniel Fried
Department of Preventive and Restorative Dental Sciences, University of California, San Francisco, 707 Parnassus Ave, San Francisco, CA 94143, USA
4 shared publications Chaoyu Ma
Department of Microbiology, Immunology and Molecular Genetics, Joe R. & Teresa Lozano Long School of Medicine, University of Texas Health Science Center at San Antonio, San Antonio, TX 78229, USA
1 shared publicationCharles Q. Le
Department of Preventive and Restorative Dental Sciences, University of California, San Francisco, California
1 shared publicationChi Ho
Department of Preventive and Restorative Dental Sciences, UCSF School of Dentistry, 707 Parnassus Ave, San Francisco, California 94143‐0758
1 shared publicationCynthia L. Darling
Department of Preventive and Restorative Dental Sciences, UCSF School of Dentistry, 707 Parnassus Ave, San Francisco, California 94143‐0758
1 shared publication
Latest Publications
- 3 April 2009
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 41 (4) , 256-263
Pulpal effects of enamel ablation with a microsecond pulsed λ = 9.3‐µm CO2 laser
Background and Objectives: In vitro studies have shown that CO2 lasers operating at the highly absorbed 9.3 and 9.6‐µm wavelengths with a pulse duration in the range of 10–20‐microsecond are well suited for the efficient ablation of enamel and dentin with minimal peripheral thermal damage. Even though these CO2 lasers are highly promising, they have yet to receive FDA approval. Clinical studies are necessary to determine if excessive heat deposition in the tooth may have any detrimental pulpal effects, particularly at higher ablative fluencies. The purpose of this study was to evaluate the pulpal safety of laser irradiation of tooth occlusal surfaces under the conditions required for small conservative preparations confined to enamel.Study Design/Materials and Methods: Test subjects requiring removal of third molar teeth were recruited and teeth scheduled for extraction were irradiated using a pulsed CO2 laser at a wavelength of 9.3 µm operating at 25 or 50 Hz using a incident fluence of 20 J/cm2 for a total of 3,000 laser pulses (36 J) for both rates with water cooling. Two control groups were used, one with no treatment and one with a small cut made with a conventional high‐speed hand‐piece. No anesthetic was used for any of the procedures and tooth vitality was evaluated prior to treatment by heat, cold and electrical testing. Short term effects were observed on teeth extracted within 72 hours after treatment and long term effects were observed on teeth extracted 90 days after treatment. The pulps of the teeth were fixed with formalin immediately after extraction and subjected to histological examination. Additionally, micro‐thermocouple measurements were used to estimate the potential temperature rise in the pulp chamber of extracted teeth employing the same irradiation conditions used in vivo.Results: Pulpal thermocouple measurements showed the internal temperature rise in the tooth was within safe limits, 3.3±1.4°C without water cooling versus 1.7±1.6°C with water‐cooling, n = 25, P2 laser can ablate enamel safely without harming the pulp under the rate of energy deposition employed in this study. Lasers Surg. Med. 41:256–263, 2009.
- 3 April 2009
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 41 (4) , 256-263
Pulpal effects of enamel ablation with a microsecond pulsed λ = 9.3‐µm CO2 laser
Background and Objectives: In vitro studies have shown that CO2 lasers operating at the highly absorbed 9.3 and 9.6‐µm wavelengths with a pulse duration in the range of 10–20‐microsecond are well suited for the efficient ablation of enamel and dentin with minimal peripheral thermal damage. Even though these CO2 lasers are highly promising, they have yet to receive FDA approval. Clinical studies are necessary to determine if excessive heat deposition in the tooth may have any detrimental pulpal effects, particularly at higher ablative fluencies. The purpose of this study was to evaluate the pulpal safety of laser irradiation of tooth occlusal surfaces under the conditions required for small conservative preparations confined to enamel.Study Design/Materials and Methods: Test subjects requiring removal of third molar teeth were recruited and teeth scheduled for extraction were irradiated using a pulsed CO2 laser at a wavelength of 9.3 µm operating at 25 or 50 Hz using a incident fluence of 20 J/cm2 for a total of 3,000 laser pulses (36 J) for both rates with water cooling. Two control groups were used, one with no treatment and one with a small cut made with a conventional high‐speed hand‐piece. No anesthetic was used for any of the procedures and tooth vitality was evaluated prior to treatment by heat, cold and electrical testing. Short term effects were observed on teeth extracted within 72 hours after treatment and long term effects were observed on teeth extracted 90 days after treatment. The pulps of the teeth were fixed with formalin immediately after extraction and subjected to histological examination. Additionally, micro‐thermocouple measurements were used to estimate the potential temperature rise in the pulp chamber of extracted teeth employing the same irradiation conditions used in vivo.Results: Pulpal thermocouple measurements showed the internal temperature rise in the tooth was within safe limits, 3.3±1.4°C without water cooling versus 1.7±1.6°C with water‐cooling, n = 25, P2 laser can ablate enamel safely without harming the pulp under the rate of energy deposition employed in this study. Lasers Surg. Med. 41:256–263, 2009.
- Open Access
- 8 February 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6425, 64250T
Near-infrared image-guided laser ablation of artificial caries lesions
Laser removal of dental hard tissue can be combined with optical, spectral or acoustic feedback systems to selectively ablate dental caries and restorative materials. Near-infrared (NIR) imaging has considerable potential for the optical discrimination of sound and demineralized tissue. The objective of this study was to test the hypothesis that two-dimensional NIR images of demineralized tooth surfaces can be used to guide CO2 laser ablation for the selective removal of artificial caries lesions. Highly patterned artificial lesions were produced by submerging 5 x 5 mm2 bovine enamel samples in demineralized solution for a 9-day period while sound areas were protected with acid resistant varnish. NIR imaging and polarization sensitive optical coherence tomography (PS-OCT) were used to acquire depth-resolved images at a wavelength of 1310-nm. An imaging processing module was developed to analyze the NIR images and to generate optical maps. The optical maps were used to control a CO2 laser for the selective removal of the lesions at a uniform depth. This experiment showed that the patterned artificial lesions were removed selectively using the optical maps with minimal damage to sound enamel areas. Post-ablation NIR and PS-OCT imaging confirmed that demineralized areas were removed while sound enamel was conserved. This study successfully demonstrated that near-IR imaging can be integrated with a CO2 laser ablation system for the selective removal of dental caries.
- 8 February 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6425, 64250T
Open AccessNear-infrared image-guided laser ablation of artificial caries lesions
Laser removal of dental hard tissue can be combined with optical, spectral or acoustic feedback systems to selectively ablate dental caries and restorative materials. Near-infrared (NIR) imaging has considerable potential for the optical discrimination of sound and demineralized tissue. The objective of this study was to test the hypothesis that two-dimensional NIR images of demineralized tooth surfaces can be used to guide CO2 laser ablation for the selective removal of artificial caries lesions. Highly patterned artificial lesions were produced by submerging 5 x 5 mm2 bovine enamel samples in demineralized solution for a 9-day period while sound areas were protected with acid resistant varnish. NIR imaging and polarization sensitive optical coherence tomography (PS-OCT) were used to acquire depth-resolved images at a wavelength of 1310-nm. An imaging processing module was developed to analyze the NIR images and to generate optical maps. The optical maps were used to control a CO2 laser for the selective removal of the lesions at a uniform depth. This experiment showed that the patterned artificial lesions were removed selectively using the optical maps with minimal damage to sound enamel areas. Post-ablation NIR and PS-OCT imaging confirmed that demineralized areas were removed while sound enamel was conserved. This study successfully demonstrated that near-IR imaging can be integrated with a CO2 laser ablation system for the selective removal of dental caries.
- 8 February 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6425, 64250J
Scanning ablation of root caries with acoustic feedback control
It has been previously demonstrated that short &lgr;=355-nm laser pulses can be used for the selective removal of caries lesions and composite restorative materials from occlusal surfaces with minimal damage to the peripheral sound tooth structure. One advantage of laser-systems is they can be integrated with acoustic and optical feedback systems for the automated discrimination of dental caries and restorative materials. The objective of this study was to test the hypothesis that root caries could be selectively removed from tooth surfaces using a computer controlled laserscanning system coupled with an acoustic feedback system. Dental root caries surfaces on extracted teeth were scanned with &lgr;=355-nm laser pulses at irradiation intensities ranging from 0.6 to 0.8 J/cm2. Acoustic feedback signals were acquired and used to control the laser output and scanning stages were used to position the laser over carious dentin until all the caries were removed to a fixed depth. Polarization optical coherence tomography (PSOCT) was used to acquire images of the root caries lesions before and after removal by the laser in order to assess if ablation was selective. The amplitude of the acoustic waves generated during the ablation of carious dentin was higher than for sound dentin allowing the acoustic feedback system to discriminate between sound and carious dentin. PS-OCT showed that caries were removed to a depth of up to 1.5-mm with minimal peripheral damage to peripheral sound dentin. The acoustic feedback was successfully used to distinguish between root caries and sound dentin, enabling the selective removal of caries from dentin surfaces using a &lgr;=355-nm, Nd:YAG Q-switched laser system.
- 8 February 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6425, 64250J
Scanning ablation of root caries with acoustic feedback control
It has been previously demonstrated that short &lgr;=355-nm laser pulses can be used for the selective removal of caries lesions and composite restorative materials from occlusal surfaces with minimal damage to the peripheral sound tooth structure. One advantage of laser-systems is they can be integrated with acoustic and optical feedback systems for the automated discrimination of dental caries and restorative materials. The objective of this study was to test the hypothesis that root caries could be selectively removed from tooth surfaces using a computer controlled laserscanning system coupled with an acoustic feedback system. Dental root caries surfaces on extracted teeth were scanned with &lgr;=355-nm laser pulses at irradiation intensities ranging from 0.6 to 0.8 J/cm2. Acoustic feedback signals were acquired and used to control the laser output and scanning stages were used to position the laser over carious dentin until all the caries were removed to a fixed depth. Polarization optical coherence tomography (PSOCT) was used to acquire images of the root caries lesions before and after removal by the laser in order to assess if ablation was selective. The amplitude of the acoustic waves generated during the ablation of carious dentin was higher than for sound dentin allowing the acoustic feedback system to discriminate between sound and carious dentin. PS-OCT showed that caries were removed to a depth of up to 1.5-mm with minimal peripheral damage to peripheral sound dentin. The acoustic feedback was successfully used to distinguish between root caries and sound dentin, enabling the selective removal of caries from dentin surfaces using a &lgr;=355-nm, Nd:YAG Q-switched laser system.
- 16 October 2006
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 38 (9) , 837-845
Dissolution studies of bovine dental enamel surfaces modified by high-speed scanning ablation with aλ = 9.3-µm TEA CO2 laser
- 16 October 2006
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 38 (9) , 837-845
Dissolution studies of bovine dental enamel surfaces modified by high-speed scanning ablation with aλ = 9.3-µm TEA CO2 laser
- 9 February 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6137, 61370F
Use of a compact fiber optic spectrometer for spectral feedback during the laser ablation of dental hard tissues and restorative materials
One perceived disadvantage of caries removal using lasers is the loss of the tactile feedback associated with the handpiece. However, alternative methods of acoustic and optical feedback become available with the laser that can be exploited to provide information about the chemical composition of the material ablated, the ablation efficiency and rate, the depth of the incision, and the surface and plume temperature during ablation. Such information can be used to increase the selectivity of ablation, avoid peripheral thermal damage and excessive heat deposition in the tooth, and provide a mechanism of robotic automation. The objective of this study was to test the hypothesis that a compact fiberoptic spectrometer could be used to differentiate between the ablation of sound and carious enamel and dentin and between dental hard tissues and composite. Sound and carious tooth surfaces along with composite restorative materials were scanned with λ=0.355, 2.79 and 9.3 μm laser pulses at irradiation intensities ranging from 0.5-100 J/cm2 and spectra were acquired from λ=250-900-nm using a compact fiber-optic spectrometer. Emission spectra varied markedly with the laser wavelength and pulse duration. Optical feedback was not successful in differentiating between sound and carious enamel and dentin even with the addition of various chromophores to carious lesion areas. However, the spectral feedback was successfully used to differentiate between composites and sound enamel and dentin enabling the selective removal of composite from tooth surfaces using a computer controlled λ=9.3-μm pulsed CO2 laser and scanning system.
- 9 February 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6137, 61370F
Use of a compact fiber optic spectrometer for spectral feedback during the laser ablation of dental hard tissues and restorative materials
One perceived disadvantage of caries removal using lasers is the loss of the tactile feedback associated with the handpiece. However, alternative methods of acoustic and optical feedback become available with the laser that can be exploited to provide information about the chemical composition of the material ablated, the ablation efficiency and rate, the depth of the incision, and the surface and plume temperature during ablation. Such information can be used to increase the selectivity of ablation, avoid peripheral thermal damage and excessive heat deposition in the tooth, and provide a mechanism of robotic automation. The objective of this study was to test the hypothesis that a compact fiberoptic spectrometer could be used to differentiate between the ablation of sound and carious enamel and dentin and between dental hard tissues and composite. Sound and carious tooth surfaces along with composite restorative materials were scanned with λ=0.355, 2.79 and 9.3 μm laser pulses at irradiation intensities ranging from 0.5-100 J/cm2 and spectra were acquired from λ=250-900-nm using a compact fiber-optic spectrometer. Emission spectra varied markedly with the laser wavelength and pulse duration. Optical feedback was not successful in differentiating between sound and carious enamel and dentin even with the addition of various chromophores to carious lesion areas. However, the spectral feedback was successfully used to differentiate between composites and sound enamel and dentin enabling the selective removal of composite from tooth surfaces using a computer controlled λ=9.3-μm pulsed CO2 laser and scanning system.
- 9 February 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6137, 61370G
Analysis of peripheral thermal damage during the rapid ablation of dentin and bone using a λ= 9.3-μm TEA CO 2 laser
TEA CO2 lasers tuned to the strong mineral absorption of hydroxyapatite at λ =9-μm are ideally suited for the efficient ablation of dental hard tissues if the laser-pulse duration is stretched to greater than 10-μs to avoid plasma formation. CO2 lasers are capable of operating at high repetition rates for the rapid removal of dentin and bone. The purpose of this study was to test the hypothesis that stretched λ =9.3-μm TEA CO2 laser pulses can produce lateral incisions in dentin and bone for dental restorations and implants at repetition rates as high as 400-Hz without peripheral thermal damage. A high repetition rate, 0-500-Hz, λ =9.3-μm TEA CO2 laser with pulse durations of 10-20-μs was used to make incisions in human dentin and porcine alveolar bone with a computer controlled scanning stage and water spray at varying irradiation intensities. The single pulse ablation rates were determined for incident fluence ranging from 1-150-J/cm2. Lateral incisions 2-3-mm in length were produced in the 2-mm thick sections. Following irradiation, transverse cross-sections were examined using polarized light microscopy (PLM) and Fourier transform infrared spectro-microscopy (SR-FTIR) at the Advanced Light Source at Lawrence Berkeley National Laboratory. The single-pulse ablation rates approached 40-μm per pulse for the stretched TEA laser pulses in dentin and bone. All incisions with and without water spray yielded thermal damage zones of less than 22-μm. Thermal damage zones with water spray were less than 14-μm, even at repetition rates of 400-Hz and SR-FTIR showed no spectral changes around the periphery of the incisions. CO2 laser pulses at λ =9.3-μm of 10-20-μs duration are well suited for the precise removal of dentin and bone for dental restorations and implants at high repetition rates without peripheral thermal damage.
- 9 February 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6137, 61370G
Analysis of peripheral thermal damage during the rapid ablation of dentin and bone using a λ= 9.3-μm TEA CO 2 laser
TEA CO2 lasers tuned to the strong mineral absorption of hydroxyapatite at λ =9-μm are ideally suited for the efficient ablation of dental hard tissues if the laser-pulse duration is stretched to greater than 10-μs to avoid plasma formation. CO2 lasers are capable of operating at high repetition rates for the rapid removal of dentin and bone. The purpose of this study was to test the hypothesis that stretched λ =9.3-μm TEA CO2 laser pulses can produce lateral incisions in dentin and bone for dental restorations and implants at repetition rates as high as 400-Hz without peripheral thermal damage. A high repetition rate, 0-500-Hz, λ =9.3-μm TEA CO2 laser with pulse durations of 10-20-μs was used to make incisions in human dentin and porcine alveolar bone with a computer controlled scanning stage and water spray at varying irradiation intensities. The single pulse ablation rates were determined for incident fluence ranging from 1-150-J/cm2. Lateral incisions 2-3-mm in length were produced in the 2-mm thick sections. Following irradiation, transverse cross-sections were examined using polarized light microscopy (PLM) and Fourier transform infrared spectro-microscopy (SR-FTIR) at the Advanced Light Source at Lawrence Berkeley National Laboratory. The single-pulse ablation rates approached 40-μm per pulse for the stretched TEA laser pulses in dentin and bone. All incisions with and without water spray yielded thermal damage zones of less than 22-μm. Thermal damage zones with water spray were less than 14-μm, even at repetition rates of 400-Hz and SR-FTIR showed no spectral changes around the periphery of the incisions. CO2 laser pulses at λ =9.3-μm of 10-20-μs duration are well suited for the precise removal of dentin and bone for dental restorations and implants at high repetition rates without peripheral thermal damage.
- 9 February 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6137, 61370H
A high repetition rate TEA CO 2 laser operating at λ=9.3-μm for the rapid and conservative ablation and modification of dental hard tissues
TEA CO2 lasers tuned to the strong mineral absorption of hydroxyapatite near λ=9-μm are ideally suited for the efficient ablation of dental hard tissues if the laser-pulse is stretched to greater than 5-10-μs to avoid plasma shielding phenomena. Such CO2 lasers are capable of operating at high repetition rates for the rapid removal of dental hard tissues. An Impact 2500 TEA CO2 laser system from GSI Lumonics (Rugby, UK) custom modified by LightMachinery (Ottawa, Canada) with a repetition rate of 0-500 Hz was used for rapid tissue removal. The single pulse ablation rates through enamel were determined for incident fluence ranging from (1-160 J/cm2). Lateral incisions using a computer controlled scanning stage and water spray were produced and the crater morphology and chemical composition were measured using optical microscopy and high-resolution synchrotron radiation infrared spectromicroscopy. The transmission through 2-meter length 300, 500, 750 and 1000-μm silica hollow waveguides was measured and 80% transmission was achieved with 40-mJ per pulse. The λ=9.3-μm laser pulses efficiently removed dental enamel at rates exceeding 15-μm per pulses with minimal heat accumulation. The residual energy remaining in tooth samples was measured to be 30-40% without water cooling, significantly lower than for longer CO2 laser pulses. These results suggest that high repetition rate TEA CO2 laser systems operating at λ=9.3-μm with pulse durations of 10-20-μs are ideally suited for dental application.
- 9 February 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6137, 61370H
A high repetition rate TEA CO 2 laser operating at λ=9.3-μm for the rapid and conservative ablation and modification of dental hard tissues
TEA CO2 lasers tuned to the strong mineral absorption of hydroxyapatite near λ=9-μm are ideally suited for the efficient ablation of dental hard tissues if the laser-pulse is stretched to greater than 5-10-μs to avoid plasma shielding phenomena. Such CO2 lasers are capable of operating at high repetition rates for the rapid removal of dental hard tissues. An Impact 2500 TEA CO2 laser system from GSI Lumonics (Rugby, UK) custom modified by LightMachinery (Ottawa, Canada) with a repetition rate of 0-500 Hz was used for rapid tissue removal. The single pulse ablation rates through enamel were determined for incident fluence ranging from (1-160 J/cm2). Lateral incisions using a computer controlled scanning stage and water spray were produced and the crater morphology and chemical composition were measured using optical microscopy and high-resolution synchrotron radiation infrared spectromicroscopy. The transmission through 2-meter length 300, 500, 750 and 1000-μm silica hollow waveguides was measured and 80% transmission was achieved with 40-mJ per pulse. The λ=9.3-μm laser pulses efficiently removed dental enamel at rates exceeding 15-μm per pulses with minimal heat accumulation. The residual energy remaining in tooth samples was measured to be 30-40% without water cooling, significantly lower than for longer CO2 laser pulses. These results suggest that high repetition rate TEA CO2 laser systems operating at λ=9.3-μm with pulse durations of 10-20-μs are ideally suited for dental application.
- 9 February 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6137, 61370S
Selective ablation of pit and fissure caries from occlusal surfaces using λ=355-nm laser pulses and air-abrasion demonstrated using PS-OCT and near-IR imaging
Several past studies have suggested that lasers with and without added chromophores can be used for the selective removal of dental caries from stained pit and fissures in preparation for composite sealant placement with minimal damage to sound, unstained tooth structure. Polarization sensitive optical coherence tomography (PS-OCT) is a new nondestructive imaging technology that can be used to acquire images of caries lesions in occlusal surfaces. PSOCT is ideally suited to measure the caries depth and severity before and after selective removal from occlusal surfaces. In this study, λ=355-nm laser pulses of 5-ns duration at irradiation intensities ranging from 0.5-1.3 J/cm2 were scanned across tooth surfaces to selectively remove decayed enamel with and without the addition of India ink. PS-OCT images were acquired before and after removal. The laser removal was also compared to air abrasion in order to compare selectivity of these two conservative caries removal technologies.
- 9 February 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6137, 61370S
Selective ablation of pit and fissure caries from occlusal surfaces using λ=355-nm laser pulses and air-abrasion demonstrated using PS-OCT and near-IR imaging
Several past studies have suggested that lasers with and without added chromophores can be used for the selective removal of dental caries from stained pit and fissures in preparation for composite sealant placement with minimal damage to sound, unstained tooth structure. Polarization sensitive optical coherence tomography (PS-OCT) is a new nondestructive imaging technology that can be used to acquire images of caries lesions in occlusal surfaces. PSOCT is ideally suited to measure the caries depth and severity before and after selective removal from occlusal surfaces. In this study, λ=355-nm laser pulses of 5-ns duration at irradiation intensities ranging from 0.5-1.3 J/cm2 were scanned across tooth surfaces to selectively remove decayed enamel with and without the addition of India ink. PS-OCT images were acquired before and after removal. The laser removal was also compared to air abrasion in order to compare selectivity of these two conservative caries removal technologies.
- 1 January 2006
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 11 (6) , 064008-064008-11
Rapid and conservative ablation and modification of enamel, dentin, and alveolar bone using a high repetition rate transverse excited atmospheric pressure CO[sub 2] laser operating at λ=9.3 μm
Transverse excited atmospheric pressure (TEA) lasers tuned to the strong mineral absorption of hydroxyapatite near are well suited for the efficient ablation of dental hard tissues if the laser pulse is stretched to greater than to avoid plasma shielding phenomena. Such lasers are capable of operating at high repetition rates for the rapid removal of dental hard tissues. The purpose of this study was to test the hypothesis that stretched TEA laser pulses can produce lateral incisions in enamel, dentin, and alveolar bone for dental restorations and implants at repetition rates as high as without peripheral thermal damage. The single pulse ablation rates through enamel, dentin, and bone were determined for incident fluence ranging from for laser pulses from in duration. Lateral incisions were produced in hard tissue samples using a computer-controlled scanning stage and water spray, and the crater morphology and chemical composition were measured using optical microscopy and high-resolution synchrotron radiation infrared spectromicroscopy. The residual energy remaining in tooth samples was measured to be 30 to 40% for enamel and 20 to 30% for dentin without water cooling, under optimum irradiation intensities, significantly lower than for longer laser pulses. The transmission through length 300-, 500-, 750-, and silica hollow waveguides was measured and 80% transmission was achieved with per pulse. These results suggest that high repetition rate TEA laser systems operating at with pulse durations of are well suited for dental applications.- 1 January 2006
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 11 (6) , 064008-064008-11
Rapid and conservative ablation and modification of enamel, dentin, and alveolar bone using a high repetition rate transverse excited atmospheric pressure CO[sub 2] laser operating at λ=9.3 μm
Transverse excited atmospheric pressure (TEA) lasers tuned to the strong mineral absorption of hydroxyapatite near are well suited for the efficient ablation of dental hard tissues if the laser pulse is stretched to greater than to avoid plasma shielding phenomena. Such lasers are capable of operating at high repetition rates for the rapid removal of dental hard tissues. The purpose of this study was to test the hypothesis that stretched TEA laser pulses can produce lateral incisions in enamel, dentin, and alveolar bone for dental restorations and implants at repetition rates as high as without peripheral thermal damage. The single pulse ablation rates through enamel, dentin, and bone were determined for incident fluence ranging from for laser pulses from in duration. Lateral incisions were produced in hard tissue samples using a computer-controlled scanning stage and water spray, and the crater morphology and chemical composition were measured using optical microscopy and high-resolution synchrotron radiation infrared spectromicroscopy. The residual energy remaining in tooth samples was measured to be 30 to 40% for enamel and 20 to 30% for dentin without water cooling, under optimum irradiation intensities, significantly lower than for longer laser pulses. The transmission through length 300-, 500-, 750-, and silica hollow waveguides was measured and 80% transmission was achieved with per pulse. These results suggest that high repetition rate TEA laser systems operating at with pulse durations of are well suited for dental applications.